Your browser doesn't support javascript.
loading
Simplified and efficient quantification of low-abundance proteins at very high multiplex via targeted mass spectrometry.
Burgess, Michael W; Keshishian, Hasmik; Mani, D R; Gillette, Michael A; Carr, Steven A.
Afiliación
  • Burgess MW; Broad Institute of MIT and Harvard, 7 Cambridge Center, Cambridge, Massachusetts 02142;
Mol Cell Proteomics ; 13(4): 1137-49, 2014 Apr.
Article en En | MEDLINE | ID: mdl-24522978
ABSTRACT
Liquid chromatography-multiple reaction monitoring mass spectrometry (LC-MRM-MS) of plasma that has been depleted of abundant proteins and fractionated at the peptide level into six to eight fractions is a proven method for quantifying proteins present at low nanogram-per-milliliter levels. A drawback of fraction-MRM is the increased analysis time due to the generation of multiple fractions per biological sample. We now report that the use of heated, long, fused silica columns (>30 cm) packed with 1.9 µm of packing material can reduce or eliminate the need for fractionation prior to LC-MRM-MS without a significant loss of sensitivity or precision relative to fraction-MRM. We empirically determined the optimal column length, temperature, gradient duration, and sample load for such assays and used these conditions to study detection sensitivity and assay precision. In addition to increased peak capacity, longer columns packed with smaller beads tolerated a 4- to 6-fold increase in analyte load without a loss of robustness or reproducibility. The longer columns also provided a 4-fold improvement in median limit-of-quantitation values with increased assay precision relative to the standard 12 cm columns packed with 3 µm material. Overall, the optimized chromatography provided an approximately 3-fold increase in analysis throughput with excellent robustness and less than a 2-fold reduction in quantitative sensitivity relative to fraction-MRM. The value of the system for increased multiplexing was demonstrated by the ability to configure an 800-plex MRM-MS assay, run in a single analysis, comprising 2400 transitions with retention time scheduling to monitor 400 unlabeled and heavy labeled peptide pairs.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Espectrometría de Masas / Proteínas Sanguíneas / Cromatografía Liquida Límite: Animals Idioma: En Revista: Mol Cell Proteomics Asunto de la revista: BIOLOGIA MOLECULAR / BIOQUIMICA Año: 2014 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Espectrometría de Masas / Proteínas Sanguíneas / Cromatografía Liquida Límite: Animals Idioma: En Revista: Mol Cell Proteomics Asunto de la revista: BIOLOGIA MOLECULAR / BIOQUIMICA Año: 2014 Tipo del documento: Article