Your browser doesn't support javascript.
loading
Microsphere localization and dose quantification using positron emission tomography/CT following hepatic intraarterial radioembolization with yttrium-90 in patients with advanced hepatocellular carcinoma.
Lea, William B; Tapp, Katie N; Tann, Mark; Hutchins, Gary D; Fletcher, James W; Johnson, Matthew S.
Afiliación
  • Lea WB; Department of Radiology and Imaging Sciences, Indiana University, 550 N. University Boulevard, Room 0663, Indianapolis, IN 46202.
  • Tapp KN; Department of Radiology and Imaging Sciences, Indiana University, 550 N. University Boulevard, Room 0663, Indianapolis, IN 46202; School of Health Sciences, Purdue University, West Lafayette, Indiana.
  • Tann M; Department of Radiology and Imaging Sciences, Indiana University, 550 N. University Boulevard, Room 0663, Indianapolis, IN 46202.
  • Hutchins GD; Department of Radiology and Imaging Sciences, Indiana University, 550 N. University Boulevard, Room 0663, Indianapolis, IN 46202.
  • Fletcher JW; Department of Radiology and Imaging Sciences, Indiana University, 550 N. University Boulevard, Room 0663, Indianapolis, IN 46202.
  • Johnson MS; Department of Radiology and Imaging Sciences, Indiana University, 550 N. University Boulevard, Room 0663, Indianapolis, IN 46202. Electronic address: matjohns@iupui.edu.
J Vasc Interv Radiol ; 25(10): 1595-603, 2014 Oct.
Article en En | MEDLINE | ID: mdl-25156647
PURPOSE: To characterize the distribution of absorbed radiation dose after glass microsphere radioembolization for hepatocellular carcinoma (HCC) using yttrium-90 ((90)Y) positron emission tomography/computed tomography (PET/CT). MATERIALS AND METHODS: In this retrospective study, 64 (90)Y PET/CT scans performed after treatment were evaluated following (90)Y glass-bead radioembolization in patients with advanced HCC. The intended dose to the target volume ranged from 83-129 Gy. Three-dimensional "dose maps" were created from reconstructed PET images using a voxel-based S-value transformation. Liver parenchyma and liver tumors were contoured on cross-sectional imaging and aligned with the created dose maps. RESULTS: There were 113 tumors examined as part of 64 lobar treatments. The average tumor size was 4.8 cm ± 4.0 with an average tumor dose of 173 Gy ± 109. The average dose to the nontumor parenchyma within the target volume was 93.4 Gy ± 32.6, with on average 50% of the parenchymal voxels receiving > 79 Gy ± 23 and 10% receiving > 173 Gy ± 55. The average and median tumor-to-parenchymal weighted dose ratios were 2.2 and 1.9, respectively. CONCLUSIONS: Using recommended dosimetry and administration techniques for lobar glass microsphere radioembolization, high doses to target tumors as well as background parenchyma were achieved on average with modest preferential uptake within tumors. There was wide variation in measured tumor and parenchymal doses after hepatic radioembolization for HCC, suggesting the need for continued development of patient-specific dosimetry.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Dosificación Radioterapéutica / Radioisótopos de Itrio / Tomografía Computarizada por Rayos X / Carcinoma Hepatocelular / Radiofármacos / Tomografía de Emisión de Positrones / Embolización Terapéutica / Imagen Multimodal / Arteria Hepática / Neoplasias Hepáticas Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Vasc Interv Radiol Asunto de la revista: ANGIOLOGIA / RADIOLOGIA Año: 2014 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Dosificación Radioterapéutica / Radioisótopos de Itrio / Tomografía Computarizada por Rayos X / Carcinoma Hepatocelular / Radiofármacos / Tomografía de Emisión de Positrones / Embolización Terapéutica / Imagen Multimodal / Arteria Hepática / Neoplasias Hepáticas Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Vasc Interv Radiol Asunto de la revista: ANGIOLOGIA / RADIOLOGIA Año: 2014 Tipo del documento: Article