Your browser doesn't support javascript.
loading
Spectrofluorimetric determination of dopamine receptor antagonist LE 300 in mice plasma.
Hefnawy, Mohamed; Mohamed, Mostafa; Abunassif, Mohamed; Alanazi, Amer; Al-Majed, Abdulrahman; Jochen, Lehmann; Mostafa, Gamal Abdel-Hafiz.
Afiliación
  • Hefnawy M; Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh, 11451, Saudi Arabia.
  • Mohamed M; Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh, 11451, Saudi Arabia.
  • Abunassif M; Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh, 11451, Saudi Arabia.
  • Alanazi A; Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh, 11451, Saudi Arabia.
  • Al-Majed A; Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh, 11451, Saudi Arabia.
  • Jochen L; Institut fur Pharmazie, Lehrstuhl fur Pharmazeutische/Medizinische Chemie, Friedrich Schiller, Universitat Jena, Jena, Germany.
  • Mostafa GA; Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh, 11451, Saudi Arabia.
Luminescence ; 31(1): 63-6, 2016 Feb.
Article en En | MEDLINE | ID: mdl-25892547
A simple, rapid and highly sensitive spectrofluorimetric method was developed for determination of a novel type of dopamine receptor antagonist LE300 in mouse plasma. The method is based on measuring the native fluorescence of LE-300 in methanol at 343 nm after excitation at 280 nm. The fluorescence concentration plot was rectilinear over the range of 3.5-100 ng/mL with a lower detection limit of 1.0 ng/mL and quantification limit of 3.5 ng/mL. The method was statistically validated for linearity, accuracy, precision and selectivity according to the International Conference on Harmonization guidelines. The accuracy and precision results was expressed as % recovery and relative standard deviation (RSD). The accuracy for LE-300 was in the range 95.5-103.6% and RSD values were in the range of 0.21-1.55% of the theoretical value. The method was successfully applied to the analysis of LE-300 in mice plasma. The results were compared statistically with those obtained by the reported method and were found to be in good agreement, which could be applied in a pharmacokinetic study.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Antagonistas de Dopamina / Indoles Límite: Animals Idioma: En Revista: Luminescence Asunto de la revista: BIOFISICA / BIOQUIMICA Año: 2016 Tipo del documento: Article País de afiliación: Arabia Saudita

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Antagonistas de Dopamina / Indoles Límite: Animals Idioma: En Revista: Luminescence Asunto de la revista: BIOFISICA / BIOQUIMICA Año: 2016 Tipo del documento: Article País de afiliación: Arabia Saudita