Your browser doesn't support javascript.
loading
Width Based Quantitation of Chromatographic Peaks: Principles and Principal Characteristics.
Kadjo, Akinde F; Dasgupta, Purnendu K; Su, Jianzhong; Liu, SuYu; Kraiczek, Karsten G.
Afiliación
  • Kadjo AF; Department of Chemistry and Biochemistry, University of Texas at Arlington , Arlington, Texas 76019-0065, United States.
  • Dasgupta PK; Department of Chemistry and Biochemistry, University of Texas at Arlington , Arlington, Texas 76019-0065, United States.
  • Su J; Department of Mathematics, University of Texas at Arlington , Arlington, Texas 76019-0408, United States.
  • Liu S; Department of Mathematics, University of Texas at Arlington , Arlington, Texas 76019-0408, United States.
  • Kraiczek KG; Agilent Technologies , Hewlett-Packard Strasse 8, D 76337 Waldbronn, Germany.
Anal Chem ; 89(7): 3884-3892, 2017 04 04.
Article en En | MEDLINE | ID: mdl-28244311
ABSTRACT
Height- and area-based quantitation reduce two-dimensional data to a single value. For a calibration set, there is a single height- or area-based quantitation equation. High-speed high-resolution data acquisition now permits rapid measurement of the width of a peak (Wh), at any height h (a fixed height, not a fixed fraction of the peak maximum) leading to any number of calibration curves. We propose a width-based quantitation (WBQ) paradigm complementing height or area based approaches. When the analyte response across the measurement range is not strictly linear, WBQ can offer superior overall performance (lower root-mean-square relative error over the entire range) compared to area- or height-based linear regression methods, rivaling weighted linear regression, provided that response is uniform near the height used for width measurement. To express concentration as an explicit function of width, chromatographic peaks are modeled as two different independent generalized Gaussian distribution functions, representing, respectively, the leading/trailing halves of the peak. The simple generalized equation can be expressed as Wh = p(ln h̅)q, where h̅ is hmax/h, hmax being the peak amplitude, and p and q being constants. This fits actual chromatographic peaks well, allowing explicit expressions for Wh. We consider the optimum height for quantitation. The width-concentration relationship is given as ln C = aWhn + b, where a, b, and n are constants. WBQ ultimately performs quantitation by projecting hmax from the width, provided that width is measured at a fixed height in the linear response domain. A companion paper discusses several other utilitarian attributes of width measurement.

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: Anal Chem Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: Anal Chem Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos