Your browser doesn't support javascript.
loading
Does air pollution really impact the onset of spontaneous pneumothorax? A French case-crossover study.
Marx, Tania; Bernard, Nadine; Parmentier, Anne-Laure; Puyraveau, Marc; Martin, Berenger; Gantelet, Madeleine; Pretalli, Jean-Baptiste; Dalphin, Jean-Charles; Mauny, Frédéric; Desmettre, Thibaut.
Afiliación
  • Marx T; Emergency Department, CHU de Besançon, 3 boulevard Alexandre Fleming, 25030 Besançon, France; Laboratory Chrono-environnement, UMR 6249 Centre National de la Recherche Scientifique, 16 route de Gray, 25000 Besançon, France; Université Bourgogne Franche-Comté, 32 avenue de l'Observatoire, 25000 Besan
  • Bernard N; Laboratory Chrono-environnement, UMR 6249 Centre National de la Recherche Scientifique, 16 route de Gray, 25000 Besançon, France; Laboratory TheMA, UMR 6049 Centre National de la Recherche Scientifique, 16 route de Gray, 25000 Besançon, France; Université Bourgogne Franche-Comté, 32 avenue de l'Obse
  • Parmentier AL; Laboratory Chrono-environnement, UMR 6249 Centre National de la Recherche Scientifique, 16 route de Gray, 25000 Besançon, France; Clinical Methodology Center, CHU de Besançon, 2 place Saint-Jacques, 25030 Besançon, France; Université Bourgogne Franche-Comté, 32 avenue de l'Observatoire, 25000 Besanç
  • Puyraveau M; Laboratory Chrono-environnement, UMR 6249 Centre National de la Recherche Scientifique, 16 route de Gray, 25000 Besançon, France; Clinical Methodology Center, CHU de Besançon, 2 place Saint-Jacques, 25030 Besançon, France; Université Bourgogne Franche-Comté, 32 avenue de l'Observatoire, 25000 Besanç
  • Martin B; Clinical Methodology Center, CHU de Besançon, 2 place Saint-Jacques, 25030 Besançon, France.
  • Gantelet M; Clinical Methodology Center, CHU de Besançon, 2 place Saint-Jacques, 25030 Besançon, France; Université Bourgogne Franche-Comté, 32 avenue de l'Observatoire, 25000 Besançon, France.
  • Pretalli JB; Emergency Department, CHU de Besançon, 3 boulevard Alexandre Fleming, 25030 Besançon, France.
  • Dalphin JC; Laboratory Chrono-environnement, UMR 6249 Centre National de la Recherche Scientifique, 16 route de Gray, 25000 Besançon, France; Pneumology Department, CHU de Besançon, 3 boulevard Alexandre Fleming, 25030 Besançon, France; Université Bourgogne Franche-Comté, 32 avenue de l'Observatoire, 25000 Besa
  • Mauny F; Laboratory Chrono-environnement, UMR 6249 Centre National de la Recherche Scientifique, 16 route de Gray, 25000 Besançon, France; Clinical Methodology Center, CHU de Besançon, 2 place Saint-Jacques, 25030 Besançon, France; Université Bourgogne Franche-Comté, 32 avenue de l'Observatoire, 25000 Besanç
  • Desmettre T; Emergency Department, CHU de Besançon, 3 boulevard Alexandre Fleming, 25030 Besançon, France; Laboratory Chrono-environnement, UMR 6249 Centre National de la Recherche Scientifique, 16 route de Gray, 25000 Besançon, France; Université Bourgogne Franche-Comté, 32 avenue de l'Observatoire, 25000 Besan
Environ Int ; 127: 317-323, 2019 06.
Article en En | MEDLINE | ID: mdl-30953814
ABSTRACT
RATIONALE A link is established between air pollution and respiratory diseases. Very few studies evaluated this link with primary spontaneous pneumothorax (PSP). Contrasted results, low statistical power and methodological limits of these studies brought us to evaluate in a more thorough way this link.

OBJECTIVES:

(1) to estimate the relation between PSP and air pollutants namely nitrogen dioxide (NO2), ozone (O3) and particulate matter with a diameter ≤ 10 µm (PM10); (2) to investigate a time lag effect between these pollutants and occurrence of PSP.

METHODS:

This study has a case-crossover design. Subjects aged ≥18 years admitted from 1st June 2009 to 31st May 2013, in 14 Emergency Departments centers on the French territory. Were excluded patients with traumatic, secondary, recurrent or history of previous pneumothorax. NO2, O3 and PM10 data were collected hourly in monitoring stations. Three exposure assessments were retained quantitative values, fast increase concentration of air pollutants and peak of pollution. These assessments were calculated for the entire exposure period and for each of the four days of all case and control periods.

RESULTS:

948 subjects included. Whatever the pollutant considered, no differences were observed between case and control periods, regardless of whether the quantitative values of air pollutants exposure (p > 0.09), fast increase concentration (p > 0.46) and peak of pollution (p > 0.20).

CONCLUSIONS:

We failed to show a relation between PSP and short-term air pollution exposure to low levels of NO2 and PM10. An association between O3 exposure and PSP cannot be ruled out. An impact at higher exposure level, and/or a potentiating effect of different meteorological factors remain to be demonstrated.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Neumotórax / Contaminantes Atmosféricos Tipo de estudio: Clinical_trials Límite: Adult / Female / Humans / Male Idioma: En Revista: Environ Int Año: 2019 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Neumotórax / Contaminantes Atmosféricos Tipo de estudio: Clinical_trials Límite: Adult / Female / Humans / Male Idioma: En Revista: Environ Int Año: 2019 Tipo del documento: Article