Facile High-Performance Liquid Chromatography Mass Spectrometry Method for Analysis of Cyclocreatine and Phosphocyclocreatine in Complex Mixtures of Amino Acids.
Tao, Dingyin; Leister, William; Huang, Wenwei; Alimardanov, Asaf; LeClair, Christopher A.
Afiliación
  • Tao D; National Center for Advancing Translational Sciences , National Institutes of Health , 9800 Medical Center Drive , Rockville , Maryland 20850 , United States.
  • Leister W; National Center for Advancing Translational Sciences , National Institutes of Health , 9800 Medical Center Drive , Rockville , Maryland 20850 , United States.
  • Huang W; National Center for Advancing Translational Sciences , National Institutes of Health , 9800 Medical Center Drive , Rockville , Maryland 20850 , United States.
  • Alimardanov A; National Center for Advancing Translational Sciences , National Institutes of Health , 9800 Medical Center Drive , Rockville , Maryland 20850 , United States.
  • LeClair CA; National Center for Advancing Translational Sciences , National Institutes of Health , 9800 Medical Center Drive , Rockville , Maryland 20850 , United States.
J Agric Food Chem ; 67(25): 7190-7196, 2019 Jun 26.
Article en En | MEDLINE | ID: mdl-31194545
ABSTRACT
Creatine transporter deficiency (CTD) is caused by a defect in the X-linked creatine transporter SLC6A8 gene leading to severe neurologic and physiologic conditions. Cyclocreatine and phosphocyclocreatine supplementation is seen as a potential treatment, but the presence of these compounds within commercially available dietary supplements presents the risk of self-medication. High-performance liquid chromatography-mass spectrometry (HPLC-MS) is an excellent technique to assess composition of complex amino acid mixtures. Herein, we have developed a facile HPLC-MS method using a cyano column in hydrophilic interaction liquid chromatography (HILIC) mode with isocratic elution over 4 min to identify the main components of two commercially available dietary supplements. The relative standard deviation (RSD) for retention time and extracted ion integrated area are <0.3% and 4%, respectively, showing excellent reproducibility. Cyclocreatine and phosphocyclocreatine were not detectable within the dietary supplements, even at ppm levels, demonstrating the power and importance of the developed HPLC-MS method in analyzing complex mixtures.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fosfocreatina / Espectrometría de Masas / Cromatografía Líquida de Alta Presión / Creatinina / Imidazolidinas / Aminoácidos Tipo de estudio: Evaluation_studies Idioma: En Revista: J Agric Food Chem Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fosfocreatina / Espectrometría de Masas / Cromatografía Líquida de Alta Presión / Creatinina / Imidazolidinas / Aminoácidos Tipo de estudio: Evaluation_studies Idioma: En Revista: J Agric Food Chem Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos