Your browser doesn't support javascript.
loading
Hybrid fluorescent magnetic gastrojejunostomy: an experimental feasibility study in the porcine model and human cadaver.
Watanabe, Ryohei; Barberio, Manuel; Kanaji, Shingo; Lapergola, Alfonso; Ashoka, Anila Hoskere; Andreiuk, Bohdan; Guerriero, Ludovica; Pizzicannella, Margherita; Seeliger, Barbara; Saida, Yoshihisa; Kaneko, Hironori; Worreth, Marc; Saadi, Alend; Marescaux, Jacques; Klymchenko, Andrey S; Diana, Michele.
Afiliación
  • Watanabe R; IHU-Strasbourg, Institute of Hybrid Image-Guided Surgery, 1, place de l'Hôpital, 67091, Strasbourg, France.
  • Barberio M; Department of Surgery, Toho University Ohashi Medical Center, Tokyo, Japan.
  • Kanaji S; IRCAD, Research Institute Against Digestive Cancer, Strasbourg, France.
  • Lapergola A; IHU-Strasbourg, Institute of Hybrid Image-Guided Surgery, 1, place de l'Hôpital, 67091, Strasbourg, France. manuel.barberio@ihu-strasbourg.eu.
  • Ashoka AH; IRCAD, Research Institute Against Digestive Cancer, Strasbourg, France.
  • Andreiuk B; IHU-Strasbourg, Institute of Hybrid Image-Guided Surgery, 1, place de l'Hôpital, 67091, Strasbourg, France.
  • Guerriero L; Laboratoire de Bioimagerie et Pathologies, UMR 7021, CNRS, Université de Strasbourg, Illkirch-Strasbourg, France.
  • Pizzicannella M; Laboratoire de Bioimagerie et Pathologies, UMR 7021, CNRS, Université de Strasbourg, Illkirch-Strasbourg, France.
  • Seeliger B; IHU-Strasbourg, Institute of Hybrid Image-Guided Surgery, 1, place de l'Hôpital, 67091, Strasbourg, France.
  • Saida Y; IHU-Strasbourg, Institute of Hybrid Image-Guided Surgery, 1, place de l'Hôpital, 67091, Strasbourg, France.
  • Kaneko H; IHU-Strasbourg, Institute of Hybrid Image-Guided Surgery, 1, place de l'Hôpital, 67091, Strasbourg, France.
  • Worreth M; Department of Surgery, Toho University Ohashi Medical Center, Tokyo, Japan.
  • Saadi A; Department of Surgery, Toho University Ohashi Medical Center, Tokyo, Japan.
  • Marescaux J; Department of Surgery, Neuchâtel Hospital, Neuchâtel, Switzerland.
  • Klymchenko AS; Department of Surgery, Neuchâtel Hospital, Neuchâtel, Switzerland.
  • Diana M; IHU-Strasbourg, Institute of Hybrid Image-Guided Surgery, 1, place de l'Hôpital, 67091, Strasbourg, France.
Surg Endosc ; 34(3): 1393-1400, 2020 03.
Article en En | MEDLINE | ID: mdl-31317330
ABSTRACT

BACKGROUND:

Laparoscopic gastrojejunostomies are time consuming and require a specific training. Alternatively, sutureless anastomosis can be achieved using endoscopically delivered magnetic rings. Our aim was to assess the feasibility and reproducibility of an endo-laparoscopic gastrojejunostomy technique, using a pair of magnets coated with a near-infrared fluorescent biocompatible polymeric material.

METHODS:

Five pigs (3 acute and 2 survival models) and one human anatomical specimen were included. In the survival models, the distal ring was inserted into the duodenum endoscopically, and it was fixed to a thread clipped to the gastric mucosa. Twenty-four hours later, a two-port laparoscopy was performed using a near-infrared (NIR) laparoscope. The magnet position in the jejunum was detected with the transluminal fluorescence of the dye. Magnetic interaction with the metallic tip of the laparoscopic grasper allowed to capture the ring and bring the bowel loop to the future anastomotic site on the gastric wall. The proximal magnet was inserted into the stomach endoscopically and released when magnetic interaction started, allowing for a precise connection with the distal ring. The animals were followed up for 12 days and underwent control endoscopies and radiograms. In the acute animals, the anastomotic procedure was repeated 24 times. Finally, the procedure was performed in the human anatomical specimen.

RESULTS:

There were no technical problems, and magnetic connection could be precisely directed at both the anterior and posterior gastric walls. No complications occurred during the survival period and the anastomoses were patent on day 5. Transluminal fluorescence enabled a rapid detection of the magnet.

CONCLUSIONS:

Hybrid-reduced port magnetic gastrojejunostomy using a pair of fluorescently coated magnetic rings was feasible, reproducible, and easy to perform in both porcine and cadaver models.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Derivación Gástrica / Laparoscopía / Imanes / Colorantes Fluorescentes Tipo de estudio: Prognostic_studies Límite: Animals / Humans Idioma: En Revista: Surg Endosc Asunto de la revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Derivación Gástrica / Laparoscopía / Imanes / Colorantes Fluorescentes Tipo de estudio: Prognostic_studies Límite: Animals / Humans Idioma: En Revista: Surg Endosc Asunto de la revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Año: 2020 Tipo del documento: Article País de afiliación: Francia