Your browser doesn't support javascript.
loading
Reduced acquisition times for measurement of myocardial blood flow with 99mTc-tetrofosmin and solid-state detector SPECT.
Do, Jeffrey; Ruddy, Terrence D; Wells, R Glenn.
Afiliación
  • Do J; Division of Cardiology, University of Ottawa Heart Institute, 40 Ruskin St, Ottawa, Canada.
  • Ruddy TD; Division of Cardiology, University of Ottawa Heart Institute, 40 Ruskin St, Ottawa, Canada.
  • Wells RG; Division of Cardiology, University of Ottawa Heart Institute, 40 Ruskin St, Ottawa, Canada. gwells@ottawaheart.ca.
J Nucl Cardiol ; 28(6): 2518-2529, 2021 12.
Article en En | MEDLINE | ID: mdl-32026329
ABSTRACT

BACKGROUND:

Measurement of myocardial blood flow (MBF) is feasible using SPECT imaging but the acquisition requires more time than usual. Our study assessed the impact of reducing acquisition times on the accuracy and repeatability of the uptake rate constant (K1).

METHODS:

Twenty-nine patients underwent two rest/stress studies with Tc-99m-tetrofosmin 18 ± 13 days apart, using a one-day rest/stress dynamic SPECT imaging protocol with a solid-state cardiac camera. A 5-minute static image was acquired prior to tracer injection for subtraction of residual activity, followed immediately by 11-minute of list-mode data collection. Static image acquisition times of 0.5, 1, and 3 minutes and dynamic imaging times of 5, 7, and 9 minutes were simulated by truncating list-mode data. Images were reconstructed with/without attenuation correction and with/without motion correction. Kinetic parameters were calculated using a 1-tissue-compartment model.

RESULTS:

K1 increased with reduced dynamic but not static imaging time (P < 0.001). The increase in K1 for a 9-minute scan was small (4.7 ± 5.3%) compared with full-length studies. The repeatability of K1 did not change significantly (13 ± 12%, P > 0.17).

CONCLUSIONS:

A shortened imaging protocol of 3-minute (rest) or 30-second (stress) static image acquisition and 9 minutes of dynamic image acquisition altered K1 by less than 5% compared to a previously validated 11-minute acquisition.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Compuestos Organofosforados / Compuestos de Organotecnecio / Tomografía Computarizada de Emisión de Fotón Único / Radiofármacos / Circulación Coronaria / Imagen de Perfusión Miocárdica Tipo de estudio: Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Nucl Cardiol Asunto de la revista: CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Compuestos Organofosforados / Compuestos de Organotecnecio / Tomografía Computarizada de Emisión de Fotón Único / Radiofármacos / Circulación Coronaria / Imagen de Perfusión Miocárdica Tipo de estudio: Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Nucl Cardiol Asunto de la revista: CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Canadá