Your browser doesn't support javascript.
loading
Applying the concept of uncertainty to the sFlt-1/PlGF cut-offs for diagnosis and prognosis of preeclampsia.
Lévy, Pacifique; Hamdi, Safouane; Guiboudenche, Jean; Haguet, Marie Clothilde; Bailleul, Sophie; Lefèvre, Guillaume.
Afiliación
  • Lévy P; Biochemistry Department, Tenon Hospital, AP-HP, Sorbonne University, Paris, France.
  • Hamdi S; Biochemistry Department, CHU Toulouse, Toulouse III University, Toulouse, France.
  • Guiboudenche J; Endocrinology Department, Cochin Hospital, AP-HP, University of Paris, Paris, France.
  • Haguet MC; Biochemistry Department, Armand Trousseau Hospital, AP-HP, Sorbonne University, Paris, France.
  • Bailleul S; Biochemistry Department, Tenon Hospital, AP-HP, Sorbonne University, Paris, France.
  • Lefèvre G; Biochemistry Department, Tenon Hospital, AP-HP, Sorbonne University, Paris, France.
Clin Chem Lab Med ; 59(4): 681-686, 2021 03 26.
Article en En | MEDLINE | ID: mdl-33645933
ABSTRACT

OBJECTIVES:

Placental growth factor (PlGF) and soluble fms-like tyrosine kinase-1 (sFlt-1) assays and the corresponding ratios (sFlt-1/PlGF) have been proposed to aid in the diagnosis by exclusion and/or prognosis of preeclampsia (PE). A method for evaluating ratio uncertainties (RUs), based on the theory of error propagation, was applied to the sFlt-1/PlGF ratio.

METHODS:

RUs were calculated using data derived from sFlt-1 and PlGF Internal Quality Control (IQC) results collected from four centers using Elecsys (Roche) or Kryptor (Thermo Fisher) sFlt-1 and PlGF assays. The corresponding ratio uncertainties were defined for each ratio value.

RESULTS:

The RUs increased linearly with the sFlt-1/PlGF ratio values. The Elecsys RUs were lower than the Kryptor RUs. Although RUs cannot eliminate differences in ratio values observed among various immunoassays, it can affect interpretation of the sFlt-1/PlGF ratio, especially when results are within the range of predefined PE diagnosis or prognosis cut-offs.

CONCLUSIONS:

Since RUs are only a function of PlGF and sFlt-1 precision, they can be calculated for each assay from each laboratory to adjust the interpretation of sFlt-1/PlGF ratio results in the context of PE.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Preeclampsia Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Female / Humans / Pregnancy Idioma: En Revista: Clin Chem Lab Med Asunto de la revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2021 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Preeclampsia Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Female / Humans / Pregnancy Idioma: En Revista: Clin Chem Lab Med Asunto de la revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2021 Tipo del documento: Article País de afiliación: Francia