Your browser doesn't support javascript.
loading
A computational model for predicting changes in infection dynamics due to leakage through N95 respirators.
Hariharan, Prasanna; Sharma, Neha; Guha, Suvajyoti; Banerjee, Rupak K; D'Souza, Gavin; Myers, Matthew R.
Afiliación
  • Hariharan P; Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, USA. Prasanna.Hariharan@fda.hhs.gov.
  • Sharma N; University of Cincinnati, 2600 Clifton Ave., Cincinnati, OH, 45221, USA.
  • Guha S; Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, USA.
  • Banerjee RK; University of Cincinnati, 2600 Clifton Ave., Cincinnati, OH, 45221, USA.
  • D'Souza G; Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, USA.
  • Myers MR; Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, USA.
Sci Rep ; 11(1): 10690, 2021 05 21.
Article en En | MEDLINE | ID: mdl-34021181
ABSTRACT
In the absence of fit-testing, leakage of aerosolized pathogens through the gaps between the face and N95 respirators could compromise the effectiveness of the device and increase the risk of infection for the exposed population. To address this issue, we have developed a model to estimate the increase in risk of infection resulting from aerosols leaking through gaps between the face and N95 respirators. The gaps between anthropometric face-geometry and N95 respirators were scanned using computed tomography. The gap profiles were subsequently input into CFD models. The amount of aerosol leakage was predicted by the CFD simulations. Leakage levels were validated using experimental data obtained using manikins. The computed amounts of aerosol transmitted to the respiratory system, with and without leaks, were then linked to a risk-assessment model to predict the infection risk for a sample population. An influenza outbreak in which 50% of the population deployed respirators was considered for risk assessment. Our results showed that the leakage predicted by the CFD model matched the experimental data within about 13%. Depending upon the fit between the headform and the respirator, the inward leakage for the aerosols ranged between 30 and 95%. In addition, the non-fit-tested respirator lowered the infection rate from 97% (for no protection) to between 42 and 80%, but not to the same level as the fit-tested respirators (12%). The CFD-based leakage model, combined with the risk-assessment model, can be useful in optimizing protection strategies for a given population exposed to a pathogenic aerosol.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ensayo de Materiales / Filtración / Respiradores N95 / Máscaras / Modelos Teóricos Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Sci Rep Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ensayo de Materiales / Filtración / Respiradores N95 / Máscaras / Modelos Teóricos Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Sci Rep Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos