The Use of Robotics in Surgery of Benign Liver Diseases: A Systematic Review.
Tsekouras, Konstantinos; Spartalis, Eleftherios; Mamakos, Nikolaos; Tsourouflis, Gerasimos; Nikiteas, Nikolaos I; Dimitroulis, Dimitrios.
Afiliación
  • Tsekouras K; Hellenic Minimally Invasive and Robotic Surgery (MIRS) Study Group, Athens Medical School, 68989National and Kapodistrian University of Athens, Athens, Greece.
  • Spartalis E; Hellenic Minimally Invasive and Robotic Surgery (MIRS) Study Group, Athens Medical School, 68989National and Kapodistrian University of Athens, Athens, Greece.
  • Mamakos N; Second Department of Propaedeutic Surgery, Laiko Hospital, Athens Medical School, 68993National and Kapodistrian University of Athens, Athens, Greece.
  • Tsourouflis G; Hellenic Minimally Invasive and Robotic Surgery (MIRS) Study Group, Athens Medical School, 68989National and Kapodistrian University of Athens, Athens, Greece.
  • Nikiteas NI; Hellenic Minimally Invasive and Robotic Surgery (MIRS) Study Group, Athens Medical School, 68989National and Kapodistrian University of Athens, Athens, Greece.
  • Dimitroulis D; Second Department of Propaedeutic Surgery, Laiko Hospital, Athens Medical School, 68993National and Kapodistrian University of Athens, Athens, Greece.
Surg Innov ; 29(2): 258-268, 2022 Apr.
Article en En | MEDLINE | ID: mdl-34275339
ABSTRACT

BACKGROUND:

Surgical treatment of benign liver diseases (BLD) remains a field of conflict, due to increased risk and high complication rate. However, the introduction of minimally invasive surgery has led to increased number of patients with BLD being treated surgically, with similar outcomes and fewer complications. Current data support the application of laparoscopic surgery (LS) and robotic surgery (RS) in surgical treatment of liver malignancies, but there are insufficient data concerning the application of robotic surgery in BLD. In the present systematic review, we aimed to evaluate the application of RS in BLD surgery.

METHODS:

After a thorough search of Medline, Scopus, and Cochrane Library, 12 studies were considered eligible with a total number of 115 patients with BLD.

DISCUSSION:

In brief, RS appears to be a safe and feasible option for BLD surgery. When compared to open surgery, RS is associated with lower blood loss, shorter length of stay, and fewer complication rate. Regarding LS, the peri- and postoperative outcomes were similar, but RS can overcome the technical limitations of LS. However, the cost of RS remains a major drawback in its widespread application.

CONCLUSIONS:

Considering our findings, RS can be a safe and feasible option for BLD surgery, but further studies are needed to justify the introduction of RS in liver surgery and to define the type of patients that will benefit the most from it.