A feasibility study on improving the non-invasive detection accuracy of bottled Shuanghuanglian oral liquid using near infrared spectroscopy.
Cui, Pengdi; Wang, Qiuyue; Li, Zheng; Wu, Chenlu; Li, Gang; Zhao, Jing; Liu, Ming.
Afiliación
  • Cui P; College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China.
  • Wang Q; College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China.
  • Li Z; College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China.
  • Wu C; College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China.
  • Li G; State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China.
  • Zhao J; College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China. Electronic address: cetty3190@163.com.
  • Liu M; Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin 300192, China. Electronic address: liuming_tju@163.com.
Spectrochim Acta A Mol Biomol Spectrosc ; 274: 121120, 2022 Jun 05.
Article en En | MEDLINE | ID: mdl-35303496
ABSTRACT
The ultimate goal of the study is to present a strategy to improve the accuracy of near-infrared spectroscopy detection of Shuanghuanglian oral liquid in glass bottles without damaging the primary packaging. we adopted the multi-position spectral modeling (MPSM) method to correct the spectral variation caused by the difference of bottle and measuring position, so as to improve the measurement accuracy and find the best site combination for measuring Shuanghuanglian oral liquid. Baicalin, total flavonoids and soluble solid contents were considered as the quality indicators of the oral liquid, and partial least squares (PLS) models were employed for the single-position and multi-position spectra, respectively. The root mean square error of the validation set (RMSEP) of the optimum multi-position models are 0.7412 mg/mL for baicalin, 1.1259 mg/mL for total flavonoids and 0.9491% for soluble solids contents. Compared with the traditional single-position spectral modeling method (SPSM method), MPSM method improved the prediction accuracy of baicalin, total flavonoids and soluble solid contents by 26.84%, 31.97% and 58.14% respectively. The results showed that the MPSM method can improve the measurement accuracy of bottled oral liquid and is an effective method to eliminate the uncertainty of measurement conditions.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Flavonoides / Espectroscopía Infrarroja Corta Tipo de estudio: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Asunto de la revista: BIOLOGIA MOLECULAR Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Flavonoides / Espectroscopía Infrarroja Corta Tipo de estudio: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Asunto de la revista: BIOLOGIA MOLECULAR Año: 2022 Tipo del documento: Article País de afiliación: China