Your browser doesn't support javascript.
loading
Development and Validation of the New Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Unbound Tacrolimus in the Plasma Ultrafiltrate of Transplant Recipients.
Bodnar-Broniarczyk, Magdalena; Warzyszynska, Karola; Czerwinska, Katarzyna; Marszalek, Dorota; Dziewa, Natalia; Kosieradzki, Maciej; Pawinski, Tomasz.
Afiliación
  • Bodnar-Broniarczyk M; Department of Drug Chemistry, Medical University of Warsaw, 02-097 Warsaw, Poland.
  • Warzyszynska K; Department of General and Transplantation Surgery, Medical University of Warsaw, 02-014 Warsaw, Poland.
  • Czerwinska K; Department of Transplantation Medicine and Nephrology, Medical University of Warsaw, 02-014 Warsaw, Poland.
  • Marszalek D; Department of Drug Chemistry, Medical University of Warsaw, 02-097 Warsaw, Poland.
  • Dziewa N; Department of General and Transplantation Surgery, Medical University of Warsaw, 02-014 Warsaw, Poland.
  • Kosieradzki M; Department of General and Transplantation Surgery, Medical University of Warsaw, 02-014 Warsaw, Poland.
  • Pawinski T; Department of Drug Chemistry, Medical University of Warsaw, 02-097 Warsaw, Poland.
Pharmaceutics ; 14(3)2022 Mar 12.
Article en En | MEDLINE | ID: mdl-35336007
ABSTRACT
(1)

Background:

Only unbound tacrolimus particles are considered to be active and capable of crossing cellular membranes. Thus, the free-drug concentration might be better associated with clinical effects than the total drug concentration used for dosage adjustment. We propose a new, fully validated online liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for unbound tacrolimus concentration measurement. (2)

Methods:

The determination of the unbound tacrolimus concentration in plasma ultrafiltrate was performed with the Nexera LC system with LCMS-8050 triple quadrupole MS using ascomycin as an internal standard. Chromatographic separation was made using a HypurityC18 analytical column. MS/MS with electrospray ionization and positive-ion multiple-reaction monitoring was used. The unbound tacrolimus level was determined in 36 patients after solid organ transplantation (n = 140). (3)

Results:

A lower limit of quantification 0.1 pg/mL was achieved, and the assay was linear between 0.1 and 20 pg/mL (R2 = 0.991). No carry-over was detected. The within-run and between-run accuracies ranged between 97.8-109.7% and 98.3-107.1%, while the greatest imprecision was 10.6% and 10.7%, respectively. Free tacrolimus in patients' plasma ultrafiltrate varied between 0.06 and 18.25 pg/mL (median 0.98 pg/mL). (4)

Conclusions:

The proposed method can be easily implemented. The significance of the unbound tacrolimus concentration needs to be investigated. This may facilitate the individualization and optimization of immunosuppressive treatment.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Pharmaceutics Año: 2022 Tipo del documento: Article País de afiliación: Polonia

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Pharmaceutics Año: 2022 Tipo del documento: Article País de afiliación: Polonia