Your browser doesn't support javascript.
loading
Aortic Perforation and Ascending Dissection Due to Intra-Aortic Balloon Counterpulsation Implantation in Cardiac Surgery.
González-Ruiz, Francisco J; Rojas-Velasco, Gustavo; Lazcano-Diaz, Emmanuel A; Manzur-Sandoval, Daniel; Baeza-Herrera, Luis A; Cota-Apodaca, Luis A; Bucio-Reta, Eduardo R; Ramos-Enriquez, Angel; García-Flores, Christian Fernando; Eid-Lidt, Guering.
Afiliación
  • González-Ruiz FJ; Department of Cardiovascular Critical Care, National Institute of Cardiology "Dr. Ignacio Chávez," México City, México.
  • Rojas-Velasco G; Department of Cardiovascular Critical Care, National Institute of Cardiology "Dr. Ignacio Chávez," México City, México.
  • Lazcano-Diaz EA; Department of Cardiovascular Critical Care, National Institute of Cardiology "Dr. Ignacio Chávez," México City, México.
  • Manzur-Sandoval D; Department of Cardiovascular Critical Care, National Institute of Cardiology "Dr. Ignacio Chávez," México City, México.
  • Baeza-Herrera LA; Department of Cardiovascular Critical Care, National Institute of Cardiology "Dr. Ignacio Chávez," México City, México.
  • Cota-Apodaca LA; Department of Cardiovascular Critical Care, National Institute of Cardiology "Dr. Ignacio Chávez," México City, México.
  • Bucio-Reta ER; Department of Cardiovascular Critical Care, National Institute of Cardiology "Dr. Ignacio Chávez," México City, México.
  • Ramos-Enriquez A; Department of Cardiovascular Critical Care, National Institute of Cardiology "Dr. Ignacio Chávez," México City, México.
  • García-Flores CF; Department of Interventional Cardiology, National Institute of Cardiology "Dr. Ignacio Chávez", México City, México.
  • Eid-Lidt G; Department of Interventional Cardiology, National Institute of Cardiology "Dr. Ignacio Chávez", México City, México.
JACC Case Rep ; 4(15): 919-923, 2022 Aug 03.
Article en En | MEDLINE | ID: mdl-35935162
The intra-aortic balloon pump continues to be a useful ventricular assist device in cardiac surgery. Complications are estimated to be 7% to 40%, significantly high to catastrophic. We describe an aortic injury associated with the use of the device and an interdisciplinary management for the diagnostic and therapeutic approach. (Level of Difficulty: Intermediate.).
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: JACC Case Rep Año: 2022 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: JACC Case Rep Año: 2022 Tipo del documento: Article