Your browser doesn't support javascript.
loading
The Use of the International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspiration Biopsy.
Nikas, Ilias P; Vey, Johannes A; Proctor, Tanja; AlRawashdeh, Mousa M; Ishak, Angela; Ko, Hyang Mi; Ryu, Han Suk.
Afiliación
  • Nikas IP; School of Medicine, European University Cyprus, Nicosia, Cyprus.
  • Vey JA; Institute of Medical Biometry, University of Heidelberg, Heidelberg, Germany.
  • Proctor T; Institute of Medical Biometry, University of Heidelberg, Heidelberg, Germany.
  • AlRawashdeh MM; School of Medicine, European University Cyprus, Nicosia, Cyprus.
  • Ishak A; School of Medicine, European University Cyprus, Nicosia, Cyprus.
  • Ko HM; Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, Canada.
  • Ryu HS; Department of Pathology, Seoul National University College of Medicine, Seoul, Korea.
Am J Clin Pathol ; 159(2): 138-145, 2023 02 01.
Article en En | MEDLINE | ID: mdl-36370120
ABSTRACT

OBJECTIVES:

To perform the first meta-analysis regarding the pooled risk of malignancy (ROM) of each category of the Yokohama system for reporting breast fine-needle aspiration, as well as assess the latter's diagnostic accuracy using this new system.

METHODS:

Two databases were searched, followed by data extraction, study quality assessment, and statistical analysis.

RESULTS:

The "Insufficient," "Benign," "Atypical," "Suspicious," and "Malignant" Yokohama system categories were associated with a pooled ROM of 17% (95% CI, 10%-28%), 1% (95% CI, 1%-3%), 20% (95% CI, 17%-23%), 86% (95% CI, 79%-92%), and 100% (95% CI, 99%-100%), respectively. When both "Suspicious" and "Malignant" interpretations were regarded as cytologically positive, sensitivity (SN) was 91% (95% CI, 87.6%-93.5%) and false-positive rate (FPR) was 2.33% (95% CI, 1.30-4.14%). A summary receiver operating characteristic curve was constructed and the pooled area under the curve was 97.3%, while the pooled diagnostic odds ratio was 564 (95% CI, 264-1,206), indicating a high level of diagnostic accuracy. When only "Malignant" interpretations were regarded as cytologically positive, the pooled FPR was lower (0.75%; 95% CI, .39%-1.42%) but at the expense of SN (76.61%; 95% CI, 70.05%-82.10%).

CONCLUSIONS:

Despite Yokohama's system early success, more data would be needed to unravel the system's value in clinical practice.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Mama / Citodiagnóstico Tipo de estudio: Prognostic_studies / Systematic_reviews Límite: Humans Idioma: En Revista: Am J Clin Pathol Año: 2023 Tipo del documento: Article País de afiliación: Chipre

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Mama / Citodiagnóstico Tipo de estudio: Prognostic_studies / Systematic_reviews Límite: Humans Idioma: En Revista: Am J Clin Pathol Año: 2023 Tipo del documento: Article País de afiliación: Chipre