Your browser doesn't support javascript.
loading
Analytical performance of the rapid qualitative antigen kit for the detection of SARS-CoV-2 during widespread circulation of the Omicron variant.
Suzuki, Hiromichi; Akashi, Yusaku; Kato, Daisuke; Takeuchi, Yuto; Kiyasu, Yoshihiko; Terada, Norihiko; Kurihara, Yoko; Kuwahara, Miwa; Muramatsu, Shino; Ueda, Atsuo; Notake, Shigeyuki; Nakamura, Koji.
Afiliación
  • Suzuki H; Department of Infectious Diseases, University of Tsukuba Hospital, 2-1-1 Amakubo, Tsukuba, Ibaraki, 305-8576, Japan; Division of Infectious Diseases, Department of Medicine, Tsukuba Medical Center Hospital, 1-3-1 Amakubo Tsukuba, Ibaraki, 305-8558, Japan; Department of Infectious Diseases, Faculty o
  • Akashi Y; Division of Infectious Diseases, Department of Medicine, Tsukuba Medical Center Hospital, 1-3-1 Amakubo Tsukuba, Ibaraki, 305-8558, Japan; Department of Infectious Diseases, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan; Akashi Internal Medicine Clinic
  • Kato D; Denka Co., Ltd. Gosen Site, Research & Development Division, Reagent R&D Department, 1-2-2 Minami-hon-cho, Gosen-shi, Niigata, 959-1695, Japan. Electronic address: daisuke-kato@denka.co.jp.
  • Takeuchi Y; Department of Infectious Diseases, University of Tsukuba Hospital, 2-1-1 Amakubo, Tsukuba, Ibaraki, 305-8576, Japan; Division of Infectious Diseases, Department of Medicine, Tsukuba Medical Center Hospital, 1-3-1 Amakubo Tsukuba, Ibaraki, 305-8558, Japan. Electronic address: yuto-takeuchi@umin.ac.jp
  • Kiyasu Y; Department of Infectious Diseases, University of Tsukuba Hospital, 2-1-1 Amakubo, Tsukuba, Ibaraki, 305-8576, Japan; Division of Infectious Diseases, Department of Medicine, Tsukuba Medical Center Hospital, 1-3-1 Amakubo Tsukuba, Ibaraki, 305-8558, Japan; Department of Infectious Diseases, Faculty o
  • Terada N; Division of Infectious Diseases, Department of Medicine, Tsukuba Medical Center Hospital, 1-3-1 Amakubo Tsukuba, Ibaraki, 305-8558, Japan; Department of Infectious Diseases, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan. Electronic address: terada.nori
  • Kurihara Y; Department of Infectious Diseases, University of Tsukuba Hospital, 2-1-1 Amakubo, Tsukuba, Ibaraki, 305-8576, Japan. Electronic address: kurihara.yoko.fu@un.tsukuba.ac.jp.
  • Kuwahara M; Denka Co., Ltd. Gosen Site, Research & Development Division, Reagent R&D Department, 1-2-2 Minami-hon-cho, Gosen-shi, Niigata, 959-1695, Japan. Electronic address: miwa-kuwahara@denka.co.jp.
  • Muramatsu S; Denka Co., Ltd. Gosen Site, Research & Development Division, Reagent R&D Department, 1-2-2 Minami-hon-cho, Gosen-shi, Niigata, 959-1695, Japan. Electronic address: shino-muramatsu@denka.co.jp.
  • Ueda A; Department of Clinical Laboratory, Tsukuba Medical Center Hospital, 1-3-1 Amakubo, Tsukuba, Ibaraki, 305-8558, Japan. Electronic address: atsuo.ueda06090727@outlook.jp.
  • Notake S; Department of Clinical Laboratory, Tsukuba Medical Center Hospital, 1-3-1 Amakubo, Tsukuba, Ibaraki, 305-8558, Japan. Electronic address: notake@tmch.or.jp.
  • Nakamura K; Department of Clinical Laboratory, Tsukuba Medical Center Hospital, 1-3-1 Amakubo, Tsukuba, Ibaraki, 305-8558, Japan. Electronic address: koji-nakamura@tmch.or.jp.
J Infect Chemother ; 29(3): 257-262, 2023 Mar.
Article en En | MEDLINE | ID: mdl-36417995
ABSTRACT

INTRODUCTION:

Rapid qualitative antigen testing is essential in the clinical management of COVID-19. However, most evaluations of antigen tests have been performed before the emergence of the Omicron variant.

METHODS:

This prospective observational study evaluated QuickNavi-COVID19 Ag, a rapid antigen detection test between December 2021 and February 2022 in Japan, using real-time reverse transcription (RT)-PCR as a reference. Two nasopharyngeal samples were simultaneously collected for antigen testing and for RT-PCR. Variant analysis of the SARS-CoV-2 genomic sequencing was also performed.

RESULTS:

In total, nasopharyngeal samples were collected from 1073 participants (417 positive; 919 symptomatic; 154 asymptomatic) for analysis. Compared with those of RT-PCR, the sensitivity, specificity, positive predictive value, and negative predictive value were 94.2% (95% CI 91.6%-96.3%), 99.5% (95% CI 98.7%-99.9%), 99.2% (95% CI 97.8%-99.8%), and 96.5% (95% CI 94.8%-97.7%), respectively. The sensitivity among symptomatic individuals was 94.3% (95% CI 91.5%-96.4%). Overall, 85.9% of sequences were classified as Omicron sublineage BA.1, 12.4% were Omicron sublineage BA.2, and 1.6% were Delta B.1.617.2. (Delta variant). Most of the samples (87.1%) had Ct values of <25, and the sensitivity was 47.4% for low viral load samples (Ct ≥ 30); a similar trend has been observed in both symptomatic and asymptomatic groups.

CONCLUSIONS:

The QuickNavi-COVID19 Ag test showed sufficient diagnostic performance for the detection of the SARS-CoV-2 Omicron sublineages BA.1 and BA.2 from nasopharyngeal samples. However, the current study was mainly performed in symptomatic patients and the results are not sufficiently applicable for asymptomatic patients.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: SARS-CoV-2 / COVID-19 Tipo de estudio: Diagnostic_studies / Observational_studies / Qualitative_research Límite: Humans País/Región como asunto: Asia Idioma: En Revista: J Infect Chemother Asunto de la revista: MICROBIOLOGIA / TERAPIA POR MEDICAMENTOS Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: SARS-CoV-2 / COVID-19 Tipo de estudio: Diagnostic_studies / Observational_studies / Qualitative_research Límite: Humans País/Región como asunto: Asia Idioma: En Revista: J Infect Chemother Asunto de la revista: MICROBIOLOGIA / TERAPIA POR MEDICAMENTOS Año: 2023 Tipo del documento: Article