Fluorescence Spectroscopy for the Assessment of Microbial Load in UVC Treated Water.
Imtiaz, Sana; Anwar, Shahzad; Zada, Laiq; Ali, Hina; Khurram, M Saeed; Saeed, Azhar; Saleem, Muhammad.
Afiliación
  • Imtiaz S; National Institute of Lasers and Optronics College, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad, 45650, Pakistan.
  • Anwar S; National Institute of Lasers and Optronics College, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad, 45650, Pakistan.
  • Zada L; Department of Microbiology, Quaid-i-Azam University, Islamabad, 45320, Pakistan.
  • Ali H; National Institute of Lasers and Optronics College, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad, 45650, Pakistan.
  • Khurram MS; National Institute of Lasers and Optronics College, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad, 45650, Pakistan.
  • Saeed A; PAEC General Hospital, H-11/4, Islamabad, Pakistan.
  • Saleem M; National Institute of Lasers and Optronics College, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad, 45650, Pakistan. salim569mail@gmail.com.
J Fluoresc ; 33(6): 2339-2347, 2023 Nov.
Article en En | MEDLINE | ID: mdl-37043059
In this article, Fluorescence spectroscopy has been employed for the assessment of microbial load and it has been compared with the gold standard colony forming unit (CFU) and optical density (OD) methods. In order to develop a correlation between three characterization techniques, water samples of different microbial loads have been prepared by UVC disinfection method through an indigenously developed NUVWater sterilizer, which operates in close cycle flow configuration. A UV dose of 58.9 mJ/cm2 has been determined for 99.99% disinfection for a flow rate of 0.8 l/min. The water samples were excited at 270 nm which results in the tryptophan like fluorescence at 360 nm that decreases gradually with increase of UVC dose, indicating the bacterial degradation and it has been confirmed by OD and CFU methods. In addition, it has been proved that a close cycle water flow around UV lamp is imperative so that an appropriate dose must be delivered to microorganisms for an efficient disinfection. It has been found that due to the sensitive nature of Fluorescence spectroscopy, it yields immediate results, whereas, for CFU and OD methods, water samples needs to be inoculated for 24 h. Fluorescence spectroscopy, therefore, provide a fast, online, reliable and sensitive method for the monitoring of pathogenic quantification in drinking water.