Highly Sensitive Detection of Formaldehyde by Laser-Induced Graphene-Coated Silver Nanoparticles Electrochemical Sensing Electrodes.
Chen, Jianyue; Ling, Yunhan; Yuan, Xiaoming; He, Yuyang; Li, Shilin; Wang, Guan; Zhang, Zhengjun; Wang, Guixin.
Afiliación
  • Chen J; School of Chemical Engineering, Sichuan University, Chengdu 610065, China.
  • Ling Y; Laboratory of Advanced Materials, School of Materials Sciences and Engineering, Tsinghua University, Beijing 100084, China.
  • Yuan X; Laboratory of Advanced Materials, School of Materials Sciences and Engineering, Tsinghua University, Beijing 100084, China.
  • He Y; Laboratory of Advanced Materials, School of Materials Sciences and Engineering, Tsinghua University, Beijing 100084, China.
  • Li S; Laboratory of Advanced Materials, School of Materials Sciences and Engineering, Tsinghua University, Beijing 100084, China.
  • Wang G; School of Chemical Engineering, Sichuan University, Chengdu 610065, China.
  • Zhang Z; Laboratory of Advanced Materials, School of Materials Sciences and Engineering, Tsinghua University, Beijing 100084, China.
  • Wang G; School of Chemical Engineering, Sichuan University, Chengdu 610065, China.
Langmuir ; 39(36): 12762-12773, 2023 Sep 12.
Article en En | MEDLINE | ID: mdl-37642387
Formaldehyde (HCHO) poses a grave threat to human health because of its toxicity, but its accurate, sensitive, and rapid detection in aqueous solutions remains a major challenge. This study proposes a novel electrochemical sensor composed of a graphene-based electrode that is prepared via laser induction technology. The precursor material, polyimide, is modified via the metal ion exchange method, and the detective electrode is coated with graphene and silver nanoparticles. And the special structure of graphene-coated Ag was demonstrated using scanning electron microscopy (SEM) and high-resolution transmission electron microscopy (HRTEM), and X-ray diffraction (XRD), Fourier transform infrared (FT-IR), and X-ray photoelectron spectroscopy (XPS) results show that graphene provides more sites for Ag NRs to be exposed and increases the surface area of contact between the solution and the detection object. In addition, differential pulse voltammetry (DPV) analysis exhibits high linearity over the HCHO concentration range from 0.05 to 5 µg/mL, with a detection limit of 0.011 µg/mL (S/N = 3). The Ag NPs in the electrochemical reaction will adsorb the intermediate •CO and •OH, catalyze their combination, and finally convert to CO2 and H2O, respectively. A microdetection device, specially designed for use with commercial micro-workstations, is employed to fully demonstrate the practical application of the electrode, which paves a way for developing formaldehyde electrochemical sensors.

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Langmuir Asunto de la revista: QUIMICA Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Langmuir Asunto de la revista: QUIMICA Año: 2023 Tipo del documento: Article País de afiliación: China