Fluorescence Sensor for Zearalenone Detection Based on Oxidized Single-walled Carbon Nanohorns/N-doped Carbon Quantum Dots-aptamer.
Na, Yue; Zhang, Jiaxin; Zhang, Shunhua; Liang, Ning; Zhao, Longshan.
Afiliación
  • Na Y; School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, 110016, Liaoning, P. R. China.
  • Zhang J; School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, 110016, Liaoning, P. R. China.
  • Zhang S; School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, 110016, Liaoning, P. R. China.
  • Liang N; School of Pharmaceutical Engineering, Shenyang Pharmaceutical University, Shenyang, 110016, Liaoning Province, China. liangning@syphu.edu.cn.
  • Zhao L; School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, 110016, Liaoning, P. R. China. longshanzhao@163.com.
J Fluoresc ; 2023 Oct 13.
Article en En | MEDLINE | ID: mdl-37831356
ABSTRACT
Zearalenone (ZEN), a resorcinolactone toxin, which has been a potential threat to agricultural production and human health. In this study, a sample and rapid fluorescence sensor was established for the detection of ZEN, which is based on the fluorescence properties of N-doped carbon dots-aptamer (NCDs-apt) and the quenching ability of oxidized single-walled carbon nanohorns (oxSWCNHs). NCDs synthesized by one-step hydrothermal method were connected with ZEN-aptamer (ZEN-apt), and oxSWCNHs were added to quench the fluorescence of NCDs-apt. Therefore, an oxSWCNHs/NCDs-apt aptasensor based on fluorescence "on-off" for the determination of ZEN in food was formed. Under optimum conditions, the limit of detection (LOD) of this method was 18 ng/mL and the linear range was 20 ~ 100 ng/mL. The possible interfering substances were investigated, and the results showed excellent selectivity. The recoveries were in the range of 99.5%~114.3%, and the relative standard deviations (RSDs) were not more than 6.5%, which demonstrated that this aptasensor was successfully applied for the detection of ZEN in food samples with satisfactory result.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: J Fluoresc Asunto de la revista: BIOFISICA Año: 2023 Tipo del documento: Article