Lung Ultrasound Reproducibly Outperforms Computed Tomography in the Detection of Extravascular Lung Water in Patients Undergoing Haemodialysis.
Corcoran, John P; Hew, Mark; Attwood, Ben; Shyamsundar, Murali; Sutherland, Sheera; Ventura, Kristine; Benamore, Rachel; St Noble, Victoria; Piotrowska, Hania E; Pugh, Christopher W; Laursen, Christian B; Gleeson, Fergus V; Rahman, Najib M.
Afiliación
  • Corcoran JP; Oxford Centre for Respiratory Medicine, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, UK.
  • Hew M; Oxford Respiratory Trials Unit, University of Oxford, Oxford OX3 7LE, UK.
  • Attwood B; Allergy, Asthma & Clinical Immunology, The Alfred Hospital, Melbourne, VIC 3004, Australia.
  • Shyamsundar M; School of Public Health & Preventive Medicine, Monash University, Melbourne, VIC 3004, Australia.
  • Sutherland S; Department of Anaesthesia and Intensive Care, South Warwickshire NHS Foundation Trust, Warwick CV34 5BW, UK.
  • Ventura K; Wellcome Wolfson Institute for Experimental Medicine, Queen's University Belfast, Belfast BT7 1NN, UK.
  • Benamore R; Oxford Kidney Unit, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, UK.
  • St Noble V; Oxford Kidney Unit, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, UK.
  • Piotrowska HE; Department of Radiology, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, UK.
  • Pugh CW; Department of Radiology, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, UK.
  • Laursen CB; Oxford Respiratory Trials Unit, University of Oxford, Oxford OX3 7LE, UK.
  • Gleeson FV; Oxford Kidney Unit, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, UK.
  • Rahman NM; Nuffield Department of Medicine, University of Oxford, Oxford OX3 7LE, UK.
Diagnostics (Basel) ; 14(6)2024 Mar 11.
Article en En | MEDLINE | ID: mdl-38535011
ABSTRACT

BACKGROUND:

Lung ultrasound (LUS) is increasingly used as an extension of physical examination, informing clinical diagnosis, and decision making. There is particular interest in the assessment of patients with pulmonary congestion and extravascular lung water, although gaps remain in the evidence base underpinning this practice as a result of the limited evaluation of its inter-rater reliability and comparison with more established radiologic tests.

METHODS:

30 patients undergoing haemodialysis were prospectively recruited to an observational cohort study (NCT01949402). Patients underwent standardised LUS assessment before, during and after haemodialysis; their total LUS B-line score was generated, alongside a binary label of whether appearances were consistent with an interstitial syndrome. LUS video clips were recorded and independently scored by two blinded expert clinician sonographers. Low-dose non-contrast thoracic CT, pre- and post dialysis, was used as a "gold standard" radiologic comparison.

RESULTS:

LUS detected a progressive reduction in B-line scores in almost all patients undergoing haemodialysis, correlating with the volume of fluid removed once individuals with no or minimal B-lines upon pre-dialysis examination were discounted. When comparing CT scans pre- and post dialysis, radiologic evidence of the change in fluid status was only identified in a single patient.

CONCLUSIONS:

This is the first study to demonstrate that LUS detects changes in extravascular lung water caused by changing fluid status during haemodialysis using a blinded outcome assessment and that LUS appears to be more sensitive than CT for this purpose. Further research is needed to better understand the role of LUS in this and similar patient populations, with the aim of improving clinical care and outcomes.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Diagnostics (Basel) Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Diagnostics (Basel) Año: 2024 Tipo del documento: Article