Your browser doesn't support javascript.
loading
Distribution of peak frequency and omnipolar voltage in electrograms across the atrial body and thoracic veins in a normal heart.
Takamiya, Tomomasa; Takigawa, Masateru; Noda, Masayuki; Yamamoto, Tasuku; Martin, Claire; Shigeta, Takatoshi; Ikenouchi, Takashi; Yamaguchi, Junji; Amemiya, Miki; Negishi, Miho; Goto, Kentaro; Nishimura, Takuro; Tao, Susumu; Miyazaki, Shinsuke; Goya, Masahiko; Sasano, Tetsuo.
Afiliación
  • Takamiya T; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
  • Takigawa M; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan. teru.takigawa@gmail.com.
  • Noda M; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
  • Yamamoto T; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
  • Martin C; Cardiology Department, Royal Papworth Hospital, Cambridge, UK.
  • Shigeta T; Department of Medicine, University of Cambridge, Cambridge, UK.
  • Ikenouchi T; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
  • Yamaguchi J; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
  • Amemiya M; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
  • Negishi M; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
  • Goto K; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
  • Nishimura T; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
  • Tao S; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
  • Miyazaki S; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
  • Goya M; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
  • Sasano T; Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
Article en En | MEDLINE | ID: mdl-38880852
ABSTRACT

BACKGROUND:

The innovative peak frequency mapping facilitates the quantification of electrogram sharpness. However, reference values for normal atrial tissue are currently undefined. In this study, we explored the distribution of peak frequency and omnipolar peak-to-peak voltage (V-max) in a normal heart.

METHODS:

Twenty-two patients with structurally normal heart were included. Either the right atrium (RA) and superior vena cava (SVC) or the left atrium (LA) and pulmonary veins (PVs) were mapped during sinus rhythm.

RESULTS:

In total, 13,654 points in the RA and 4143 points in the SVC from 15 patients and 4662 points in the LA and 2761 points in PVs from 7 patients were analyzed. The correlation between peak frequency and V-max was weak (R = 0.223). The median peak frequency was larger in the SVC than in the RA (441 [358-524] Hz vs. 358 [291-441] Hz, P < 0.0001) and in PVs than in the LA (346 [253-441] Hz vs. 323 [262-397] Hz, P < 0.0001). Conversely, the median V-max was smaller in the SVC than in the RA (1.96 [0.77-3.75] mV vs. 4.11 [2.10-6.83] mV, P < 0.0001) and in PVs than in the LA (1.16 [0.33-3.17] mV vs. 4.42 [2.63-6.84] mV, P < 0.0001). More than 95% of peak frequencies were > 174 Hz in the RA and > 185 Hz in the LA, and > 95% of V-maxes were > 0.52 and > 1.07 mV in the RA and LA, respectively.

CONCLUSION:

Given the limited correlation between peak frequency and V-max, and recognizing their potential to provide distinct information, they can be used complementarily. Employing these parameters to extract varied insights can provide comprehensive understandings of tissue characteristics.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: J Interv Card Electrophysiol Asunto de la revista: CARDIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: J Interv Card Electrophysiol Asunto de la revista: CARDIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Japón