Your browser doesn't support javascript.
loading
Nitrogen-Doped Carbon Dots Enhanced Hydrogen Carbonate-Hydrogen Peroxide Chemiluminescent Reaction and its Application in Ascorbic Acid Sensing.
Li, Shuji; Su, Ke; Liu, Xing; Jiang, Xiuming; Xiang, Guoqiang; He, Lijun.
Afiliación
  • Li S; School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, 450001, People's Republic of China.
  • Su K; School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, 450001, People's Republic of China.
  • Liu X; School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, 450001, People's Republic of China.
  • Jiang X; School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, 450001, People's Republic of China.
  • Xiang G; Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Zhengzhou, 450001, Henan, People's Republic of China.
  • He L; School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, 450001, People's Republic of China. xianggq@haut.edu.cn.
J Fluoresc ; 2024 Jul 31.
Article en En | MEDLINE | ID: mdl-39083155
ABSTRACT
Nitrogen-doped carbon dots (N-CDs) were prepared by self-exothermic procedure using grasshopper powder as a single precursor. The prepared N-CDs not only have excellent fluorescence properties, but also can catalyze and enhance the ultra-weak chemiluminescence of NaHCO3-H2O2. The reaction conditions of NaHCO3-H2O2-N-CDs CL were optimized. Under the optimal experimental conditions, when AA was added to the NaHCO3-H2O2-N-CDs CL system, AA had a significant inhibitory effect on the CL intensity of NaHCO3-H2O2-N-CDs. There was a good linear relationship between the calculated lg(I0/I) and the concentration of AA (C), and the calibration curve equation was lg(I0/I) = 0.03667 C-0.00708 (µM). The established CL analysis method has a detection limit of 0.12 µM for AA and a linear range of 0-50 µM. The selectivity of CL method was evaluated, and the method was successfully applied to the determination of AA in vegetable and fruit samples. The spiked recoveries were between 88.9% and 118.9%, which indicated that the method was simple, rapid, and sensitive, and had great potential in the determination of AA in foods.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: J Fluoresc Asunto de la revista: BIOFISICA Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: J Fluoresc Asunto de la revista: BIOFISICA Año: 2024 Tipo del documento: Article