[Treatment of refractory glaucomas by transscleral cyclophotocoagulation using semiconductor diode laser. Analysis of 50 patients followed-up over 19 months]. / Traitement des glaucomes réfractaires par cyclophotocoagulation transsclérale au laser semi-conducteur diode. Analyse de 50 patients suivis pendant 19 mois.
Hamard, P; Gayraud, J M; Kopel, J; Valtot, F; Quesnot, S; Hamard, H.
Afiliación
  • Hamard P; Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts, Paris.
J Fr Ophtalmol ; 20(2): 125-33, 1997.
Article en Fr | MEDLINE | ID: mdl-9099271
PURPOSE: To evaluate the effects of transscleral cyclophotocoagulation with the diode laser for refractory glaucoma with respect to intra-ocular pressure, reduction of medical therapy and complications. METHODS: The diode laser system (Iris Medical Instrument, Oculight SLX) was used to treat 50 eyes of 47 patients with therapy resistant glaucoma and a poor prognosis with filtering surgery. All eyes had maximal hypotonic therapy and 40 (82%) patients were using carbonic anhydrase inhibitors. Laser energy was delivered to the eye through a quartz glass fiber optic probe [13 to 20 spots over 270 degrees using 3.5 J (1.75 W x 2.0 sec)]. The mean follow-up was 19.4 +/- 9.1 months (from 12 to 29 months). RESULTS: Intra-ocular pressure significantly decreased from mean baseline 32.4 +/- 9.1 mmHg to 19.7 +/- 8.1 mmHg at the end of the follow-up (p < 0.001). An intra-ocular-pressure below 20 mmHg was obtained in 66% of the eyes. In 13 patients the carbonic anhydrase inhibitors were discontinued. Six of the 8 painful eyes had pain relief. Visual acuity decreased in 17 (34%): cataract progression in 5 eyes, uncontrolled intra-ocular-pressure in 4 eyes, glaucoma progression despite controlled intra-ocular-pressure in 3 eyes, corneal dystrophy in 3 eyes. Chronic uveitis occurred in 5 (10%) eyes. No conjonctival, scleral or direct lens damage was detected. CONCLUSION: Contact transscleral cylophotocoagulation with the diode laser system can be successfully used to reduce intra-ocular-pressure in therapy resistant glaucoma. The incidence of complications is low with no loss of vision related to cyclodestruction.
Asunto(s)
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Glaucoma / Coagulación con Láser Tipo de estudio: Diagnostic_studies / Etiology_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adolescent / Adult / Aged / Aged80 / Child / Child, preschool / Female / Humans / Infant / Male Idioma: Fr Revista: J Fr Ophtalmol Año: 1997 Tipo del documento: Article
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Glaucoma / Coagulación con Láser Tipo de estudio: Diagnostic_studies / Etiology_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adolescent / Adult / Aged / Aged80 / Child / Child, preschool / Female / Humans / Infant / Male Idioma: Fr Revista: J Fr Ophtalmol Año: 1997 Tipo del documento: Article