ABSTRACT
BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; Pâ =â .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; Pâ <â .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, Pâ <â .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padjâ <â 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.
Subject(s)
Aneurysm, False , Endocarditis, Bacterial , Endocarditis , Renal Insufficiency, Chronic , Transcatheter Aortic Valve Replacement , Abscess , Aneurysm, False/complications , Aneurysm, False/surgery , Coagulase , Endocarditis/epidemiology , Endocarditis/etiology , Endocarditis/surgery , Endocarditis, Bacterial/epidemiology , Endocarditis, Bacterial/etiology , Endocarditis, Bacterial/surgery , Humans , Renal Insufficiency, Chronic/complications , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effectsABSTRACT
BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; Pâ =â .12), but the rate of early IE was lower in the CC (2.29 vs 4.89, Pâ <â .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; Pâ =â .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; Pâ =â .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; Pâ =â .036) and in-hospital (26.6% vs 36.4%; Pâ =â .016) and 1-year (37.8% vs 53.5%; Pâ <â .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (Pâ <â .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.
Subject(s)
Endocarditis, Bacterial , Endocarditis , Transcatheter Aortic Valve Replacement , Endocarditis/epidemiology , Endocarditis/etiology , Endocarditis/surgery , Endocarditis, Bacterial/epidemiology , Endocarditis, Bacterial/etiology , Endocarditis, Bacterial/surgery , Humans , Incidence , Postoperative Complications/epidemiology , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment OutcomeABSTRACT
BACKGROUND: In patients undergoing left atrial appendage (LAA) closure, an accurate sizing of the LAA is key to optimize device sizing, procedural success and reduce complications. Previous studies have shown that intraprocedural volume loading increases LAA dimensions and improves device sizing. However, the safety and effects on LAA and device sizing of administering a fluid bolus during pre-procedural transesophageal echocardiography (TEE) are unknown. The aim of this study was to determine the safety and impact on LAA dimensions and device sizing of an intravenous (IV) fluid bolus administered during TEE in the setting of the pre-procedural work-up for LAA closure. METHODS: The study included a total of 72 patients who underwent TEE to assess suitability for LAAC and received a 500 ml IV bolus of normal saline. The LAA landing zone (LZ) and depth were measured by TEE before and after volume loading, and these measurements were used to predict the device size implanted during a subsequent percutaneous LAAC procedure. RESULTS: There were no complications associated with volume loading. The baseline mean LZ was 19.6 ± 3.6 mm at 90o, and 20.2 ± 4.1 mm at 135o. Following fluid bolus, the maximum diameter increased 1.5 ± 1.0 mm at 90o (p<0.001), and 1.3 ± 1.0 mm at 135o (p<0.001). The baseline mean depth of the LAA was 26.5 ± 5.5 mm at 90o, and 23.9 ± 5.8 mm at 135o. After fluid bolus, the mean depth increased by 1.5 ± 1.8 mm (p<0.001) and 1.6 ± 2.0 (p<0.001), at 90o and 135o, respectively. Sizing based on post-bolus measurements of the LZ significantly improved the agreement with the final device size selection during the procedure in 71.0% of cases (vs. 42.0% with pre-bolus measurements). CONCLUSIONS: Volume loading during ambulatory TEE as part of the pre-procedural work-up of LAAC is safe and significantly increases LAA dimensions. This strategy may become the new standard, particularly in centers performing LAAC with no TEE guidance, as it improves LAA sizing and more accurately predicts the final device size.
Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Surgical Procedures/methods , Echocardiography, Transesophageal/methods , Aged , Atrial Appendage/diagnostic imaging , Atrial Fibrillation/diagnosis , Female , Humans , Male , Preoperative Period , Reproducibility of Results , Retrospective StudiesABSTRACT
INTRODUCTION AND OBJECTIVES: The optimal chronic antithrombotic regimen for patients with atrial fibrillation undergoing transcatheter aortic valve implantation (TAVI) remains uncertain. Our aim was to compare the incidence of late bleeding events between patients on direct oral anticoagulants (DOACs) and those on vitamin-K antagonists (VKA). METHODS: This single-center observational study included TAVI patients requiring oral anticoagulation at discharge between 2015 and 2021. The primary endpoint was any clinically significant bleeding event. Secondary endpoints were stroke, heart failure, and all-cause mortality. RESULTS: A total of 702 TAVI procedures were performed, with 297 patients requiring oral anticoagulation at discharge. Among them, 206 (69.4%) received VKA and 91 (30.6%) received DOAC. Baseline clinical, procedural and in-hospital characteristics did not significantly differ between groups, except for better renal function among DOAC patients. The median length of follow-up was 2.8 years. The risk of bleeding events was higher in patients receiving DOACs than in those receiving VKA (HR, 2.27; 95%CI, 1.21-4.26; incidence of 9.7 and 4.2 events per 100 patient-years of follow-up for DOAC and VKA patients, respectively). There were no statistically significant differences in the rates of stroke (HR, 1.28; 95%CI, 0.4-4.3), heart failure hospitalization (HR, 0.92; 95%CI, 0.46-1.86), or all-cause mortality (HR, 1.02; 95%CI, 0.68-1.55). CONCLUSIONS: In older patients undergoing TAVI and receiving anticoagulant therapy for atrial fibrillation, the use of DOAC was associated with a higher risk of late bleeding events than VKA.
ABSTRACT
OBJECTIVES: Little is known about valve hemodynamic performance during the Evolut and Neo deployment course. We aimed to evaluate transvalvular mean and peak-to-peak gradients over several intraprocedural timepoints during TAVR with Evolut PRO+ (Medtronic) and Neo (Boston Scientific) systems. METHODS: This was single-center pilot sub-study from the SavvyWire EFficacy and SafEty in Transcatheter Aortic Valve Implantation Procedures (SAFE-TAVI) trial. Participants received either the Evolut PRO+ or Neo for native valve severe aortic stenosis and the SavvyWire (OpSens Medical) was used for device delivery, pacing, and continuous left ventricular and aortic pressure measurements. For the Evolut, evaluation was done for baseline, two-thirds of valve deployment (still recapturable), 90% of valve deployment (no longer recapturable), and post-deployment hemodynamics. For the Neo, analysis was done at baseline, after the first step (top-crown deployment), and at final status. RESULTS: Nineteen patients were included (Evolut = 15; Neo = 4). There were no statistically significant changes in peak-to-peak gradients (44 mm Hg [IQR:33-69] vs 43 mm Hg [IQR:26-62], P = .41) between baseline and two-thirds of valve deployment in the Evolut patients. There was a significant decrease in mean (40 mm Hg [IQR:32-54] vs 14 mm Hg [IQR:10-18], P less than .001) and peak-to-peak (43 mmHg [IQRS:26-62] vs 9 mm Hg [IQR:8-13], P less than .001) transvalvular gradients between two-thirds and 90% of valve deployment for Evolut. Neo patients exhibited a decrease in transvalvular gradients after top-crown deployment (42.5 mm Hg baseline vs 13 mm Hg). CONCLUSIONS: Transvalvular gradients did not vary between the point of "no-recapture" compared to baseline values in patients receiving the Evolut, whereas a significant reduction in transvalvular gradients was observed when the valve was deployed at 90% and fully deployed. The Neo valve was slightly obstructive after the first step of deployment.
Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnosis , Male , Female , Hemodynamics/physiology , Aortic Valve/surgery , Aortic Valve/physiopathology , Aged, 80 and over , Treatment Outcome , Pilot Projects , Aged , Follow-Up StudiesABSTRACT
OBJECTIVES: Valve oversizing has been associated with reduced paravalvular leaks (PVL) and valve migration risk. However, no optimal cut-off oversizing value has been defined for the Evolut system (Medtronic). The aim of this study was to assess the relationship between the degree of oversizing and moderate-to-severe PVL and determine the optimal oversizing cut-off value. METHODS: We conducted a multicenter study that included 740 consecutive patients with multidetector computed tomography (CT) data. Valve size was selected according to manufacturer recommendations, with oversizing ranging from 10% to 30%. The primary endpoint was moderate-to-severe PVL. RESULTS: The median age was 84 years (79-87 years), with 58.4% women, and a median EuroSCORE II of 4.1% (2.4-7.3%). Moderate-to-severe PVL was observed in 7.0% of the patients. An inverse relationship was found between oversizing and both PVL (11.3%, 8.6%, 5.4%, and 2.7% for quartiles Q1 to Q4; P = .007) and the need for post-dilation (P = .016). The multivariable analysis showed an association between oversizing and PVL (OR: 0.915 for each 1%-increase, P = .002). The optimal oversizing cut-off value to predict PVL was 20%, and PVL was significantly higher in patients with oversizing less than 20% (10.5% vs.4.2%, P less than .001). There were no differences in major clinical events according to the degree of oversizing, and a higher oversizing did not translate into an increased risk of permanent pacemaker (18.4% vs18.3%, P = .976). CONCLUSIONS: In TAVR with the Evolut valve, a higher oversizing was associated with lower rates of moderate-to-severe PVL and a lower need for post-dilation, with no negative impact on procedural and early clinical outcomes. A 20% oversizing threshold could be suggested to reduce PVLs. Further prospective studies are warranted to validate optimal oversizing for this valve system.
Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Multidetector Computed Tomography , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Female , Male , Aged, 80 and over , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnosis , Multidetector Computed Tomography/methods , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Retrospective Studies , Treatment Outcome , Follow-Up Studies , Postoperative Complications/prevention & control , Postoperative Complications/epidemiology , Postoperative Complications/diagnosisABSTRACT
Background/Objectives: Understanding sex-based differences in cardiovascular outcomes is paramount to improving clinical outcomes. Surgery is an aggressive but effective therapy for ascending aortic aneurysm. We sought to determine if being a woman is a risk factor for long-term mortality after this surgery. We compared their life expectancy with a general population of the same age, sex, year, and region. Methods: We compared men and women undergoing AAA surgery at our institution from 2000 to 2019. After balancing the population with propensity score (PS) matching, we compared long-term mortality control with a Cox regression. We determined the RS using the Ederer II method and compared it to a healthy reference population of the same age, sex, and region. Results: From 2000 to 2019, 232 women and 506 men underwent ascending aortic aneurysm surgery. After a mean follow-up of 51.5 ± 34.5 months, sex was not an independent risk factor for long-term mortality in the multivariable analysis [HR: 0.68 (95% CI 0.43-1.07, p = 0.23)]. Matching by baseline characteristics, 196 pairs were analyzed with no differences regarding mortality in the Cox regression [HR: 1.11 (95% CI 0.65-1.9, p = 0.23)]. Men and women who survived the postoperative period presented a relative survival of 100.3% (95% CI 97.4-101%) and 100.3% (95% CI 98.9-101.1%), respectively, similar to the reference population without the disease. Conclusions: For patients undergoing AAA surgery, sex was not an independent predictor of mortality. Men and women who survived the postoperative period presented a similar life expectancy to that of the reference population (people free from the disease of the same age, sex, year, and region).
ABSTRACT
INTRODUCTION AND OBJECTIVES: Transcatheter aortic valve implantation (TAVI) using the cusp overlap technique (COT) has shown a lower pacemaker implantation rate at 30 days. The objective of this study was to compare electrocardiogram changes and clinical outcomes between COT and the traditional technique (TT) at 1 year of follow-up. METHODS: Observational, retrospective, nonrandomized study of consecutive patients undergoing TAVI between January 2015 and January 2021. Patients were matched using a propensity score and the TT was compared with COT. The primary endpoints were electrocardiogram changes and a combined endpoint including pacemaker implantation, hospitalization, or cardiovascular death at 1 year. RESULTS: We included 254 patients. After propensity score matching, 184 patients (92 per group) remained. There were no statistically significant differences in baseline characteristics. At 1 year, COT patients showed a significant reduction in new onset left bundle branch block (49% vs 27%, P=.002) and less P wave (13.1±21.0 msec vs 5.47±12.5 msec; P=.003) and QRS prolongation (29.77±27.0 msec vs 16.38±25.4 msec, P <.001). COT was associated with a significant reduction in the occurrence of the primary endpoint (SHR, 0.39 [IC95%, 0.21-0.76]; P=.005). CONCLUSIONS: At 1 year of follow-up, COT reduced the incidence of new onset left bundle branch block and diminished QRS and P wave widening compared with the TT. COT was also associated with a statistically significant reduction in the occurrence of the combined primary cardiovascular endpoint.
Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Bundle-Branch Block/complications , Retrospective Studies , Cardiac Pacing, Artificial/adverse effects , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Heart Valve Prosthesis/adverse effects , Arrhythmias, Cardiac/therapy , Pacemaker, Artificial/adverse effects , Electrocardiography , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgeryABSTRACT
INTRODUCTION AND OBJECTIVES: In patients undergoing percutaneous coronary intervention (PCI) in the workup pre-transcatheter aortic valve replacement (TAVR), the clinical impact of coronary revascularization complexity remains unknown. This study sought to examine the impact of PCI complexity on clinical outcomes after TAVR in patients undergoing PCI in the preprocedural workup. METHODS: This was a multicenter study including consecutive patients scheduled for TAVR with concomitant significant coronary artery disease. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥ 3 stents implanted, ≥ 3 lesions treated, bifurcation with 2 stents implanted, total stent length >60mm, or chronic total occlusion. The rates of major adverse cardiac events (MACE), including cardiovascular mortality, myocardial infarction, and coronary revascularization were evaluated. RESULTS: A total of 1550 patients were included, of which 454 (29.3%) underwent complex PCI in the pre-TAVR workup. After a median follow-up period of 2 [1-3] years after TAVR, the incidence of MACE was 9.6 events per 100 patients-years. Complex PCI significantly increased the risk of cardiac death (HR, 1.44; 95%CI, 1.01-2.07), nonperiprocedural myocardial infarction (HR, 1.52; 95%CI, 1.04-2.21), and coronary revascularization (HR, 2.46; 95%CI, 1.44-4.20). In addition, PCI complexity was identified as an independent predictor of MACE after TAVR (HR, 1.31; 95%CI, 1.01-1.71; P=.042). CONCLUSIONS: In TAVR candidates with significant coronary artery disease requiring percutaneous treatment, complex revascularization was associated with a higher risk of MACE. The degree of procedural complexity should be considered a strong determinant of prognosis in the PCI-TAVR population.
ABSTRACT
Background: The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) has recently introduced a consensus document that outlines risk factors to identify high bleeding risk (HBR) in patients undergoing transcatheter aortic valve replacement (TAVR). The objective of the present study was to evaluate the prevalence and predictive value of the VARC-HBR definition in a contemporary, large-scale TAVR population. Methods: Multicenter study including 10,449 patients undergoing TAVR. Based on consensus, twenty-one clinical and laboratory criteria were identified and classified as major or minor. Patients were stratified as at low, moderate, high, and very high bleeding risk according to VARC-HBR definition. The primary endpoint was the rate of BARC type 3 or 5 bleeding at 1 year, defined as the composite of peri-procedural (within 30 days) or late (after 30 days) bleeding. Results: Patients with at least one VARC-HBR criterion (n=9,267, 88.7%) had a higher risk of BARC 3 or 5 bleeding, proportional to the severity of risk assessment (10.8%, 16.1%, and 24.6% for moderate, high, and very high-risk groups, respectively). However, a comparable rate of bleeding events was observed in the low-risk and moderate-risk groups. The area under ROC curve was 0.58. Patients with VARC-HBR criteria also exhibited a gradual increase in 1-year all-cause mortality, with an up to 2-fold increased mortality risk for high and very high-risk groups (HR: 1.33, 95% CI: 1.04-1.70; and HR: 1.97, 95% CI: 1.53-2.53, respectively). Conclusions: The VARC-HBR consensus offered a pragmatic approach to guide bleeding risk stratification in TAVR. The results of the present study would support the predictive validity of the newly definition and promote its application in clinical practice to minimize bleeding risk and improve patient outcomes.
ABSTRACT
Limited data exist on patients with a transient ischemic attack (TIA) who underwent patent foramen ovale (PFO) closure. The objectives of this study were to determine the clinical and procedural characteristics and long-term outcomes of patients with TIA who underwent transcatheter PFO closure. This was a multicenter study including 1,012 consecutive patients who underwent PFO closure after a cerebrovascular event. Patients were divided into 2 groups according to their index event leading to PFO closure: TIA (n = 183 [18%]), and stroke (n = 829 [82%]). The median follow-up was 3 (2 to 8) years (complete in 98% of patients). There were no significant differences between patients with TIA and stroke, except for a lower Risk of Paradoxical Embolism score in the TIA group (6.1 vs 6.9 in the stroke group, p <0.001). PFO closure was successful in all patients with a low rate of complications (<1%) in both groups. There were no differences in the incidence of neurologic events during long-term follow-up. There was 1 stroke event in the TIA group and 6 in the stroke group (0.08 vs 0.17 per 100 patients-years, p = 0.584). There were 2 TIA events in the TIA group and 10 in the stroke group (0.17 vs 0.28 per 100 patients-years, p = 0.557). In conclusion, our study showed that patients with TIA who underwent PFO closure have similar clinical characteristics as patients with stroke including a high Risk of Paradoxical Embolism score. Furthermore, these results suggest that PFO closure procedural results and long-term clinical outcomes are similar to their stroke counterparts, with a very low incidence of recurrent neurologic events. Further prospective randomized clinical trials are needed on this population.
Subject(s)
Embolism, Paradoxical , Foramen Ovale, Patent , Ischemic Attack, Transient , Stroke , Humans , Embolism, Paradoxical/etiology , Embolism, Paradoxical/complications , Ischemic Attack, Transient/epidemiology , Ischemic Attack, Transient/etiology , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/surgery , Cardiac Catheterization/methods , Treatment Outcome , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & controlABSTRACT
Paravalvular leakage (PVL) is yet a potential and serious complication after transcatheter aortic valve replacement. Percutaneous PVL closure may be the treatment of choice upon failure of balloon postdilation in patients with excessive surgical risk. If the retrograde approach fails, an antegrade strategy might provide the solution.
ABSTRACT
Background Scarce data exist on sex differences in patients with cryptogenic cerebrovascular events undergoing patent foramen ovale (PFO) closure. This study aimed to determine the sex differences in clinical profile, procedural characteristics, and long-term outcomes of patients with cryptogenic cerebrovascular events undergoing PFO closure. Methods and Results A retrospective cohort was used, including 1076 consecutive patients undergoing PFO closure because of a cryptogenic cerebrovascular event. Patients were divided into 2 groups: 469 (43.6%) women and 607 (56.4%) men. The median follow-up was 3 years (interquartile range, 2-8 years). Women were younger (46±13 versus 50±12 years; P<0.01) and had a higher risk of paradoxical embolism score (6.9±1.7 versus 6.6±1.6; P<0.01). Procedural characteristics and postprocedural antithrombotic therapy were similar. At follow-up, there were no differences in atrial fibrillation (women versus men: 0.47 versus 0.97 per 100 patient-years; incidence rate ratio [IRR], 0.55 [95% CI, 0.27-1.11]; P=0.095; adjusted P=0.901), stroke (0.17 versus 0.07 per 100 patient-years; IRR, 2.58 [95% CI, 0.47-14.1]; P=0.274; adjusted P=0.201), or transient ischemic attack (0.43 versus 0.18 per 100 patient-years; IRR, 2.58 [95% CI, 0.88-7.54]; P=0.084; adjusted P=0.121); nevertheless, women exhibited a higher incidence of combined ischemic cerebrovascular events (0.61 versus 0.26 per 100 patient-years; IRR, 2.58 [95% CI, 1.04-6.39]; P=0.041; adjusted P=0.028) and bleeding events (1.04 versus 0.45 per 100 patient-years; IRR, 2.82 [95% CI, 1.41-5.65]; P=0.003; adjusted P=0.004). Conclusions Compared with men, women with cryptogenic cerebrovascular events undergoing PFO closure were younger and had a higher risk of paradoxical embolism score. After a median follow-up of 3 years, there were no differences in stroke events, but women exhibited a higher rate of combined (stroke and transient ischemic attack) cerebrovascular events and bleeding complications. Additional studies are warranted to clarify sex-related outcomes after PFO closure further.
Subject(s)
Embolism, Paradoxical , Foramen Ovale, Patent , Ischemic Attack, Transient , Septal Occluder Device , Stroke , Humans , Female , Male , Ischemic Attack, Transient/epidemiology , Ischemic Attack, Transient/etiology , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/epidemiology , Foramen Ovale, Patent/surgery , Sex Characteristics , Embolism, Paradoxical/epidemiology , Embolism, Paradoxical/etiology , Retrospective Studies , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Cardiac Catheterization/adverse effects , Septal Occluder Device/adverse effects , Treatment OutcomeABSTRACT
Introduction: Mitral Regurgitation (MR) has a strong impact on quality of life and on mid-term survival. Transcatheter mitral valve replacement (TMVR) is rapidly expanding and a growing number of studies have been published recently. Methods: A systematic review of studies reporting on clinical data for patients with symptomatic severe MR undergoing TMVR was performed. Early- and mid-term outcomes (clinical and echocardiographic) were evaluated. Overall weighted means and rates were calculated. Risk ratios or mean differences were calculated for pre- and post-procedural comparisons. Results: A total of 12 studies and 347 patients who underwent TMVR with devices clinically available or under clinical evaluation were included. Thirty-day mortality, stroke and major bleeding rates were 8.4%, 2.6%, and 15.6%, respectively. Pooled random-effects demonstrated a significant reduction of ≥ grade 3+ MR (RR: 0.05; 95% CI: 0.02-0.11; p < 0.001) and in the rates of patients in NYHA class 3-4 after the intervention (RR: 0.27; 95% CI: 0.22-0.34; p < 0.001). Additionally, the pooled fixed-effect mean difference for quality of life based on the KCCQ score yielded an improvement in 12.9 points (95% CI:7.4-18.4, p < 0.001), and exercise capacity improved by a pooled fixed-effect mean difference of 56.8 meters in the 6-minute walk test (95% CI 32.2-81.3, p < 0.001). Conclusions: Among 12 studies and 347 patients comprising the updated evidence with current TMVR systems there was a statistically significant reduction in ≥ grade 3+ MR and in the number of patients exhibiting poor functional class (NYHA 3 or 4) after the intervention. Overall rate of major bleeding was the main shortcoming of this technique.
ABSTRACT
BACKGROUND: The use of mitral transcatheter edge-to-edge repair (TEER) is rapidly increasing. Anatomical changes have been described after TEER with the MitraClip system in patients with functional mitral regurgitation (MR), although no study has yet evaluated such anatomical impacts in patients treated with the G4 MitraClip generation. METHODS: This research constituted a prospective, single-center, observational study including consecutive patients with functional MR. Mitral three-dimensional images were obtained transesophageally with echocardiography before and immediately after TEER. Patients receiving the late-generation (G4) system were compared to those receiving early-generation systems. RESULTS: A total of 116 functional MR patients were evaluated, and 40 (34.5%) and 76 (65.5%) received a late-generation (G4) or early-generation device system, respectively. The baseline clinical and echocardiographic features were well-balanced between the groups. Overall, there was a significant reduction in mitral annular size after the intervention, and greater reductions in the anteroposterior diameter (4 mm vs. 3.54 mm, p = 0.03), annular perimeter (11.07 mm vs. 5.29 mm for 3D-perimeter, p = 0.001), and annular area (1.29 cm2 vs. 1.03 cm2, p = 0.002) were found for patients receiving the late G4 device generation compared to the early-generation systems. CONCLUSIONS: In patients with functional MR, we observed significant changes in mitral valve anatomy with a reduction in anteroposterior diameter, valve perimeter, and area. In our cohort, the extent of those changes was greater with the use of the new-generation G4 MitraClip system compared to prior device generations.
ABSTRACT
BACKGROUND: The SavvyWire (OpSens Inc) is a 0.035-inch preshaped guidewire with dedicated pacing properties and a distal pressure sensor allowing for continuous hemodynamic pressure monitoring. OBJECTIVES: This study sought to determine the efficacy and safety of the guidewire during transcatheter aortic valve replacement (TAVR) procedures. METHODS: This prospective, multicenter clinical study included patients with severe aortic stenosis undergoing TAVR in 8 European centers. The primary efficacy endpoint was defined as effective left ventricular rapid pacing runs with the guidewire translating into a significant systemic pressure drop (below 60 mm Hg). The safety outcome included the absence of major procedural complications related to the guidewire. RESULTS: A total of 121 patients (mean age: 82.2 ± 5.9 years, 50% women) were included in the study, and 119 (98.3%) patients were finally treated with the study device. A balloon-expandable valve was implanted in 45 (37.8%) patients. Predilatation and postdilatation were performed in 89 (74.8%) and 14 (11.8%) patients, respectively. The primary efficacy endpoint was achieved in 116 (98.3%) patients, and the mean aortic systolic arterial pressure achieved during rapid pacing was 46.6 ± 11.3 mm Hg. Hemodynamic assessment with the use of the OptoMonitor 3 (OpSens Inc) without additional catheter exchange was achieved in 117 (99.2%) patients. The safety endpoint was achieved in 117 (99.2%) patients. No procedural mortality, stroke, or ventricular perforation was reported. CONCLUSIONS: The use of the guidewire during TAVR procedures appeared to be efficacious and safe. This device could help minimize interventions during the procedure and improve the clinical decision making after transcatheter heart valve deployment. (SavvyWire Efficacy and Safety in Transcatheter Aortic Valve Implantation Procedures [SAFE-TAVI]; NCT05492383).
Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Prospective Studies , Treatment OutcomeABSTRACT
INTRODUCTION AND OBJECTIVES: Despite medical advances, mortality after ST-elevation myocardial infarction (STEMI) remains high. Women are often underrepresented in trials and registries, limiting knowledge of their management and prognosis. It is unknown whether life expectancy in women of all ages treated with primary percutaneous coronary intervention (PPCI) is similar to that in a reference population free of the disease. The main objective of this study was to determine whether life expectancy in women undergoing PPCI and surviving the main event returns to a similar level to that in the general population of the same age and region. METHODS: We included all patients diagnosed with STEMI from January 2014 to October 2021. We matched women to a reference population of the same age and region from the National Institute of Statistics to determine observed survival, expected survival, and excess mortality (EM) using the Ederer II method. We repeated the analysis in women aged ≤ 65 and> 65 years. RESULTS: A total of 2194 patients were recruited, of whom 528 were women (23.9%). In women surviving the first 30 days, EM at 1, 5 and 7 years was 1.6% (95%CI, 0.3-4), 4.7% (95%CI, 0.3-10.1), and 7.2% (95%CI, 0.5-15.1), respectively. CONCLUSIONS: EM was reduced in women with STEMI who were treated with PPCI and who survived the main event. However, life expectancy remained lower than that in a reference population of the same age and region.
Subject(s)
Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , Female , Male , ST Elevation Myocardial Infarction/diagnosis , Percutaneous Coronary Intervention/methods , Prognosis , Treatment OutcomeABSTRACT
INTRODUCTION AND OBJECTIVES: Severe tricuspid regurgitation (TR) is associated with poor prognosis when left untreated, and a growing number of studies on transcatheter tricuspid valve repair (TTVr) have been published over the last few months. METHODS: We performed a comprehensive systematic review of published literature providing clinical data on TTVr for patients with significant TR. Early and mid-term clinical and echocardiographic outcomes were evaluated. Risk ratios (RR) or mean differences (MD) were obtained when comparing pre- and postprocedural data. A sensitivity analysis was also performed according to the main approach for repair (edge-to-edge vs annuloplasty). RESULTS: A total of 19 studies (all observational or single-arm trials) and 991 patients who underwent isolated TTVr were included. Thirty-day mortality and stroke rates were 2.8% and 0.2%, respectively. Pooled random-effects resulted in a significant reduction of ≥ severe TR (RR, 0.33; 95%CI, 0.26-0.42; P < .001), vena contracta width (MD, 5.9mm; 95%CI, 4-7.9; P <.001), right ventricular end-diastolic diameter (MD, 3.5mm; 95%CI, 2.5-4.5; P <.001), and New York Heart Association (NYHA) class III or IV at last follow-up (RR, 0.32; 95%CI, 0.27-0.37; P <.001). Bleeding complications and residual ≥ severe TR were numerically higher in the annuloplasty-like group compared with edge-to-edge repair (13.3% vs 3.8% for bleeding and 40.4% vs 27.9% for residual severe TR). CONCLUSIONS: Among 991 patients comprising the early experience for several TTVr devices, there was a statistically significant reduction in ≥ severe TR, NYHA class III-IV, vena contracta width and right ventricular end-diastolic diameter after TTVr. Thus far, the edge-to-edge approach seems to be associated with a better safety profile.
Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Cardiac Catheterization/methods , Tricuspid Valve Insufficiency/diagnosis , Tricuspid Valve Insufficiency/surgeryABSTRACT
The use of transcatheter edge-to-edge mitral valve repair (TEER) in symptomatic patients with severe mitral regurgitation (MR) has dramatically increased over the last few years. Current guidelines consider TEER as a reasonable option in symptomatic patients with primary or chronic secondary severe MR with high or prohibitive surgical risk and favorable anatomy. However, several anatomical and morphological mitral features have restricted the use of this mini-invasive technique in its early experience. The latest fourth generation (G4) of the MitraClip system has been recently introduced and includes the possibility of independent leaflet grasping and 4 different sizes. This technical update offers the possibility of selecting and combining multiple devices for complex mitral valve anatomies and challenging procedures, which helps expand the applications of TEER. The present review describes the potential advantages and the help of the MitraClip G4 devices to overcome various anatomic and morphologic issues in challenging cases with complex primary and secondary MR procedures.
ABSTRACT
BACKGROUND: In patients undergoing percutaneous coronary intervention (PCI) in the work-up pre-transcatheter aortic valve replacement (TAVR), the incidence and clinical impact of late bleeding events (LBEs) remain largely unknown. OBJECTIVES: This study sought to determine the incidence, clinical characteristics, associated factors, and outcomes of LBEs in patients undergoing PCI in the work-up pre-TAVR. METHODS: This was a multicenter study including 1,457 consecutive patients (mean age 81 ± 7 years; 41.5% women) who underwent TAVR and survived beyond 30 days. LBEs (>30 days post-TAVR) were defined according to the Valve Academic Research Consortium-2 criteria. RESULTS: LBEs occurred in 116 (7.9%) patients after a median follow-up of 23 (IQR: 12-40) months. Late bleeding was minor, major, and life-threatening or disabling in 21 (18.1%), 63 (54.3%), and 32 (27.6%) patients, respectively. Periprocedural (<30 days post-TAVR) major bleeding and the combination of antiplatelet and anticoagulation therapy at discharge were independent factors associated with LBEs (P ≤ 0.02 for all). LBEs conveyed an increased mortality risk at 4-year follow-up compared with no bleeding (43.9% vs 36.0; P = 0.034). Also, LBE was identified as an independent predictor of all-cause mortality after TAVR (HR: 1.39; 95% CI: 1.05-1.83; P = 0.020). CONCLUSIONS: In TAVR candidates with concomitant significant coronary artery disease requiring percutaneous treatment, LBEs after TAVR were frequent and associated with increased mortality. Combining antiplatelet and anticoagulation regimens and the occurrence of periprocedural bleeding determined an increased risk of LBEs. Preventive strategies should be pursued for preventing late bleeding after TAVR, and further studies are needed to provide more solid evidence on the most safe and effective antithrombotic regimen post-TAVR in this challenging group of patients.