Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Journal subject
Affiliation country
Publication year range
1.
Catheter Cardiovasc Interv ; 103(6): 995-1003, 2024 May.
Article in English | MEDLINE | ID: mdl-38662126

ABSTRACT

BACKGROUND: Limited data exists regarding incidence, progression, and predictors of left atrial appendage (LAA) sealing after transcatheter LAA closure. We aimed to evaluate the incidence, progression, and predictive factors associated with LAA sealing after LAA closure. METHODS: This study includes patients who underwent successful LAA closure with Watchman FLX device and had both pre- and postprocedural computed tomography (CT). Postprocedural CT was performed 45 days after LAA closure and used to evaluate residual LAA patency. Patient who had residual LAA patency at 45 days underwent 1-year follow-up CT. RESULTS: A total of 105 patients (mean age: 75.2 ± 9.6 years; 53.3% female) who underwent successful LAA closure with Watchman FLX device and had pre- and postprocedural CT at 45 days were included. Residual patency was observed in 35 (33.3%) patients: 21 (20.0%) patients showed complete contrast opacification in LAA (complete LAA patency) while 14 (13.3%) patients showed contrast opacification only in the distal LAA (distal LAA patency). Among patients with residual LAA patency at 45 days, the rate of LAA sealing at 1 year was significantly higher in the distal LAA patency group than in the complete LAA patency group (75.0% vs. 16.7%; p = 0.019). Increased depth oversizing was associated with both distal LAA patency and complete LAA patency. CONCLUSION: Postprocedural CT at 45 days detected patent LAA in one-third of patients after LAA closure. LAA sealing was more frequently observed at 1 year among the distal LAA patency group than the complete LAA patency group.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Catheterization , Predictive Value of Tests , Prosthesis Design , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Female , Male , Aged , Aged, 80 and over , Risk Factors , Treatment Outcome , Time Factors , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Retrospective Studies , Incidence , Tomography, X-Ray Computed , Multidetector Computed Tomography
2.
Am J Cardiol ; 189: 1-10, 2023 02 15.
Article in English | MEDLINE | ID: mdl-36481373

ABSTRACT

Permanent pacemaker implantation (PPMI) reduction and optimal management of newly acquired conduction disturbances after transcatheter aortic valve implantation (TAVI) are crucial. We sought to evaluate the relation between transcatheter heart valve (THV) implantation depth and baseline and newly acquired conduction disturbances on PPMI after TAVI. This study included 1,026 consecutive patients with severe symptomatic aortic stenosis (mean age 79.7 ± 8.4 years; 47.4% female) who underwent TAVI with the newer-generation self-expanding THVs Primary outcomes were early and late PPMI defined as the need for PPMI during the index admission and between discharge and 30 days, respectively. Early and late PPMI was required for 115 (11.2%) and 21 patients (2.0%), respectively. Early PPMI rates decreased from 26.7% in 2015 and 2016 to 5.7% in 2021, and so did the mean THV depth from 4.4 ± 2.4 mm to 1.8 ± 1.6 mm. Receiver operator characteristics curve analyses showed THV depth had significant discriminatory value for early and late PPMI with cutoff values of 3.0 and 2.2 mm, respectively. Rates of early and late PPMI were significantly lower for patients with shallower compared with deeper implantations (5.1% vs 22.6% and 0.4% vs 4.1%, p <0.001 for both, respectively). Furthermore, rates of early PPMI were lower with shallower implantations in patients with new left bundle branch block after TAVI (2.4% vs 15.9%; p <0.001) and those with baseline right bundle branch block (7.5% vs 29.6%; p = 0.017). Lower rates of PPMI with shallower THV implantation were consistently observed, including in patients with baseline and newly acquired conduction disturbances. Our findings might help optimize the management of a temporary pacemaker after TAVI.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Treatment Outcome , Bundle-Branch Block/therapy