Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
J Synchrotron Radiat ; 29(Pt 2): 540-548, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35254319

ABSTRACT

This work describes the instrumentation and software for microbeam scattering and structural mapping at the Life Science X-ray Scattering (LiX) beamline at NSLS-II. Using a two-stage focusing scheme, an adjustable beam size between a few micrometres and a fraction of a millimetre is produced at the sample position. Scattering data at small and wide angles are collected simultaneously on multiple Pilatus detectors. A recent addition of an in-vacuum Pilatus 900k detector, with the detector modules arranged in a C-shaped configuration, has improved the azimuthal angle coverage in the wide-angle data. As an option, fluorescence data can be collected simultaneously. Fly scans have been implemented to minimize the time interval between scattering patterns and to avoid unnecessary radiation damage to the sample. For weakly scattering samples, an in-vacuum sample environment has been developed here to minimize background scattering. Data processing for these measurements is highly sample-specific. To establish a generalized data process workflow, first the data are reduced to reciprocal coordinates at the time of data collection. The users can then quantify features of their choosing from these intermediate data and construct structural maps. As examples, results from in-vacuum mapping of onion epidermal cell walls and 2D tomographic sectioning of an intact poplar stem are presented.


Subject(s)
Biological Science Disciplines , Synchrotrons , Scattering, Small Angle , X-Ray Diffraction , X-Rays
3.
J Synchrotron Radiat ; 28(Pt 4): 1237-1244, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-34212889

ABSTRACT

During the COVID-19 pandemic, synchrotron beamlines were forced to limit user access. Performing routine measurements became a challenge. At the Life Science X-ray Scattering (LiX) beamline, new instrumentation and mail-in protocols have been developed to remove the access barrier to solution scattering measurements. Our efforts took advantage of existing instrumentation and coincided with the larger effort at NSLS-II to support remote measurements. Given the limited staff-user interaction for mail-in measurements, additional software tools have been developed to ensure data quality, to automate the adjustments in data processing, as users would otherwise rely on the experience of the beamline staff, and produce a summary of the initial assessments of the data. This report describes the details of these developments.


Subject(s)
Scattering, Small Angle , Solutions/radiation effects , Synchrotrons/instrumentation , X-Ray Diffraction/instrumentation , Buffers , COVID-19 , Data Collection , Datasets as Topic , Electronic Data Processing , Pandemics , Robotics , SARS-CoV-2 , Software , Specimen Handling , Water
4.
J Synchrotron Radiat ; 28(Pt 5): 1649-1661, 2021 Sep 01.
Article in English | MEDLINE | ID: mdl-34475312

ABSTRACT

Here we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.


Subject(s)
Crystallography, X-Ray/methods , Macromolecular Substances/chemistry , Robotics/methods , Equipment Design , Scattering, Small Angle , Software , Synchrotrons , X-Rays
5.
J Synchrotron Radiat ; 27(Pt 3): 804-812, 2020 May 01.
Article in English | MEDLINE | ID: mdl-32381785

ABSTRACT

This work reports the instrumentation and software implementation at the Life Science X-ray Scattering (LiX) beamline at NSLS-II in support of biomolecular solution scattering. For automated static measurements, samples are stored in PCR tubes and grouped in 18-position sample holders. Unattended operations are enabled using a six-axis robot that exchanges sample holders between a storage box and a sample handler, transporting samples from the PCR tubes to the X-ray beam for scattering measurements. The storage box has a capacity of 20 sample holders. At full capacity, the measurements on all samples last for ∼9 h. For in-line size-exclusion chromatography, the beamline-control software coordinates with a commercial high-performance liquid chromatography (HPLC) system to measure multiple samples in batch mode. The beamline can switch between static and HPLC measurements instantaneously. In all measurements, the scattering data span a wide q-range of typically 0.006-3.2 Å-1. Functionalities in the Python package py4xs have been developed to support automated data processing, including azimuthal averaging, merging data from multiple detectors, buffer scattering subtraction, data storage in HDF5 format and exporting the final data in a three-column text format that is acceptable by most data analysis tools. These functionalities have been integrated into graphical user interfaces that run in Jupyter notebooks, with hooks for external data analysis software.


Subject(s)
Chromatography, High Pressure Liquid , Synchrotrons/instrumentation , Chromatography, Gel , Equipment Design , Robotics , Scattering, Small Angle , Software , Specimen Handling , X-Rays
6.
J Synchrotron Radiat ; 27(Pt 3): 746-752, 2020 May 01.
Article in English | MEDLINE | ID: mdl-32381777

ABSTRACT

A versatile, compact heater designed at National Synchrotron Light Source-II for in situ X-ray nano-imaging in a full-field transmission X-ray microscope is presented. Heater design for nano-imaging is challenging, combining tight spatial constraints with stringent design requirements for the temperature range and stability. Finite-element modeling and analytical calculations were used to determine the heater design parameters. Performance tests demonstrated reliable and stable performance, including maintaining the exterior casing close to room temperature while the heater is operating at above 1100°C, a homogenous heating zone and small temperature fluctuations. Two scientific experiments are presented to demonstrate the heater capabilities: (i) in situ 3D nano-tomography including a study of metal dealloying in a liquid molten salt extreme environment, and (ii) a study of pore formation in icosahedral quasicrystals. The progression of structural changes in both studies were clearly resolved in 3D, showing that the new heater enables powerful capabilities to directly visualize and quantify 3D morphological evolution of materials under real conditions by X-ray nano-imaging at elevated temperature during synthesis, fabrication and operation processes. This heater design concept can be applied to other applications where a precise, compact heater design is required.

7.
Nat Commun ; 12(1): 3441, 2021 Jun 09.
Article in English | MEDLINE | ID: mdl-34108466

ABSTRACT

Three-dimensional bicontinuous porous materials formed by dealloying contribute significantly to various applications including catalysis, sensor development and energy storage. This work studies a method of molten salt dealloying via real-time in situ synchrotron three-dimensional X-ray nano-tomography. Quantification of morphological parameters determined that long-range diffusion is the rate-determining step for the dealloying process. The subsequent coarsening rate was primarily surface diffusion controlled, with Rayleigh instability leading to ligament pinch-off and creating isolated bubbles in ligaments, while bulk diffusion leads to a slight densification. Chemical environments characterized by X-ray absorption near edge structure spectroscopic imaging show that molten salt dealloying prevents surface oxidation of the metal. In this work, gaining a fundamental mechanistic understanding of the molten salt dealloying process in forming porous structures provides a nontoxic, tunable dealloying technique and has important implications for molten salt corrosion processes, which is one of the major challenges in molten salt reactors and concentrated solar power plants.

8.
Am J Gastroenterol ; 104(1): 125-32, 2009 Jan.
Article in English | MEDLINE | ID: mdl-19098860

ABSTRACT

OBJECTIVES: Chronic constipation is a common gastrointestinal disorder with limited treatment options. Oral administration of linaclotide, a novel peptide agonist of guanylate cyclase-C receptors, has been shown in animal studies to stimulate intestinal fluid secretion and transit. In Phase 1 studies in healthy human volunteers, linaclotide was well-tolerated, increased bowel movement frequency, and loosened stool consistency. METHODS: This randomized, double-blind, placebo-controlled pilot study evaluated the safety, tolerability, and exploratory efficacy of oral linaclotide in 42 patients with chronic constipation. Patients were randomized to linaclotide (100, 300, or 1,000 microg) or placebo once daily for 2 weeks. Bowel habits (stool frequency, consistency, straining, completeness of evacuation) and degree of abdominal discomfort were monitored daily using an interactive voice response system. Patient-reported outcomes of severity of constipation and overall relief were evaluated weekly. RESULTS: Linaclotide treatment produced dose-dependent increases from the pretreatment baseline values in weekly complete spontaneous bowel movement frequency (range: 2.2-3.2), stool consistency scores (range: 1.1-2.6, 7-point scale), and straining scores (range: 0.4-1.5, 7-point scale); corresponding placebo increases were 1.3, 0.4, 0.4, respectively. Clinical improvements were also demonstrated in abdominal discomfort, severity of constipation, and overall relief. Compared to placebo, linaclotide 100 microg/day significantly increased spontaneous bowel movement frequency, and linaclotide 1,000 microg/day significantly improved stool consistency (P<0.05). Adverse events were primarily gastrointestinal, with diarrhea being the most common. CONCLUSIONS: In this pilot study, linaclotide treatment improved bowel habits and symptoms of patients with chronic constipation. Further randomized controlled trials are warranted.


Subject(s)
Constipation/drug therapy , Gastrointestinal Agents/therapeutic use , Peptides/therapeutic use , Adult , Aged , Chronic Disease , Double-Blind Method , Female , Gastrointestinal Agents/adverse effects , Humans , Male , Middle Aged , Peptides/adverse effects , Receptors, Guanylate Cyclase-Coupled/antagonists & inhibitors , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL