1.
Eur J Appl Physiol ; 118(7): 1415-1426, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29713818

ABSTRACT

BACKGROUND: Right ventricular (RV) dysfunction and heart failure with preserved ejection fraction may contribute to exercise intolerance in obesity. To further define RV exercise responses, we investigated RV-arterial coupling in obesity with and without development of exercise pulmonary venous hypertension (ePVH). METHODS: RV-arterial coupling defined as RV end-systolic elastance/pulmonary artery elastance (Ees/Ea) was calculated from invasive cardiopulmonary exercise test data in 6 controls, 8 obese patients without ePVH (Obese-ePVH) and 8 obese patients with ePVH (Obese+ePVH) within a larger series. ePVH was defined as a resting pulmonary arterial wedge pressure < 15 mmHg but ≥ 20 mmHg on exercise. Exercise haemodynamics were further evaluated in 18 controls, 20 Obese-ePVH and 17 Obese+ePVH patients. RESULTS: Both Obese-ePVH and Obese+ePVH groups developed exercise RV-arterial uncoupling (peak Ees/Ea = 1.45 ± 0.26 vs 0.67 ± 0.18 vs 0.56 ± 0.11, p < 0.001, controls vs Obese-ePVH vs Obese+ePVH respectively) with higher peak afterload (peak Ea = 0.31 ± 0.07 vs 0.75 ± 0.32 vs 0.88 ± 0.62 mL/mmHg, p = 0.043) and similar peak contractility (peak Ees = 0.50 ± 0.16 vs 0.45 ± 0.22 vs 0.48 ± 0.17 mL/mmHg, p = 0.89). RV contractile reserve was highest in controls (ΔEes = 224 ± 80 vs 154 ± 39 vs 141 ± 34% of baseline respectively, p < 0.001). Peak Ees/Ea correlated with peak pulmonary vascular compliance (PVC, r = 0.53, p = 0.02) but not peak pulmonary vascular resistance (PVR, r = - 0.20, p = 0.46). In the larger cohort, Obese+ePVH patients on exercise demonstrated higher right atrial pressure, lower cardiac output and steeper pressure-flow responses. BMI correlated with peak PVC (r = - 0.35, p = 0.04) but not with peak PVR (r = 0.24, p = 0.25). CONCLUSIONS: Exercise RV-arterial uncoupling and reduced RV contractile reserve further characterise obesity-related exercise intolerance. RV dysfunction in obesity may develop independent of exercise LV filling pressures.


Subject(s)
Atrial Function , Exercise Tolerance , Hypertension, Pulmonary/physiopathology , Myocardial Contraction , Obesity/physiopathology , Ventricular Function , Aged , Coronary Circulation , Exercise , Female , Humans , Hypertension, Pulmonary/etiology , Male , Middle Aged , Obesity/complications , Obesity/diagnostic imaging , Pulmonary Circulation
2.
Cardiovasc Diabetol ; 15: 99, 2016 Jul 19.
Article in English | MEDLINE | ID: mdl-27431258

ABSTRACT

BACKGROUND: Glucagon-like peptide-1 (7-36) amide (GLP-1) protects against stunning and cumulative left ventricular dysfunction in humans. The mechanism remains uncertain but GLP-1 may act by opening mitochondrial K-ATP channels in a similar fashion to ischemic conditioning. We investigated whether blockade of K-ATP channels with glibenclamide abrogated the protective effect of GLP-1 in humans. METHODS: Thirty-two non-diabetic patients awaiting stenting of the left anterior descending artery (LAD) were allocated into 4 groups (control, glibenclamide, GLP-1, and GLP-1 + glibenclamide). Glibenclamide was given orally prior to the procedure. A left ventricular conductance catheter recorded pressure-volume loops during a 1-min low-pressure balloon occlusion (BO1) of the LAD. GLP-1 or saline was then infused for 30-min followed by a further 1-min balloon occlusion (BO2). In a non-invasive study, 10 non-diabetic patients were randomized to receive two dobutamine stress echocardiograms (DSE) during GLP-1 infusion with or without oral glibenclamide pretreatment. RESULTS: GLP-1 prevented stunning even with glibenclamide pretreatment; the Δ % dP/dtmax 30-min post-BO1 normalized to baseline after GLP-1: 0.3 ± 6.8 % (p = 0.02) and GLP-1 + glibenclamide: -0.8 ± 9.0 % (p = 0.04) compared to control: -11.5 ± 10.0 %. GLP-1 also reduced cumulative stunning after BO2: -12.8 ± 10.5 % (p = 0.02) as did GLP-1 + glibenclamide: -14.9 ± 9.2 % (p = 0.02) compared to control: -25.7 ± 9.6 %. Glibenclamide alone was no different to control. Glibenclamide pretreatment did not affect global or regional systolic function after GLP-1 at peak DSE stress (EF 74.6 ± 6.4 vs. 74.0 ± 8.0, p = 0.76) or recovery (EF 61.9 ± 5.7 vs. 61.4 ± 5.6, p = 0.74). CONCLUSIONS: Glibenclamide pretreatment does not abrogate the protective effect of GLP-1 in human models of non-lethal myocardial ischemia. Trial registration Clinicaltrials.gov Unique Identifier: NCT02128022.


Subject(s)
Coronary Artery Disease/drug therapy , Glucagon-Like Peptide 1/therapeutic use , Myocardial Ischemia/drug therapy , Potassium Channels/metabolism , Ventricular Dysfunction, Left/drug therapy , Adolescent , Adult , Aged , Aged, 80 and over , Coronary Artery Disease/physiopathology , Coronary Vessels/drug effects , Coronary Vessels/physiopathology , Echocardiography, Stress/methods , Female , Glucagon-Like Peptide 1/administration & dosage , Glyburide/administration & dosage , Glyburide/therapeutic use , Humans , Male , Middle Aged , Ventricular Dysfunction, Left/physiopathology , Young Adult
3.
Heart Fail Rev ; 20(3): 363-73, 2015 May.
Article in English | MEDLINE | ID: mdl-25633340

ABSTRACT

Right ventricular (RV) diastolic dysfunction was first reported as an indicator for the assessment of ventricular dysfunction in heart failure a little over two decades ago. However, the underlying mechanisms and precise role of RV diastolic dysfunction in heart failure remain poorly described. Complexities in the structure and function of the RV make the detailed assessment of the contractile performance challenging when compared to its left ventricular (LV) counterpart. LV dysfunction is known to directly affect patient outcome in heart failure. As such, the focus has therefore been on LV function. Nevertheless, a strategy for the diagnosis and assessment of RV diastolic dysfunction has not been established. Here, we review the different causal mechanisms underlying RV diastolic dysfunction, summarising the current assessment techniques used in a clinical environment. Finally, we explore the role of load-independent indices of RV contractility, derived from the conductance technique, to fully interrogate the RV and expand our knowledge and understanding of RV diastolic dysfunction. Accurate assessment of RV contractility may yield further important prognostic information that will benefit patients with diastolic heart failure.


Subject(s)
Heart Failure/physiopathology , Heart Ventricles/physiopathology , Ventricular Dysfunction, Right/physiopathology , Ventricular Function, Right , Cardiac Catheterization , Diastole , Humans , Magnetic Resonance Imaging , Stroke Volume , Ventricular Dysfunction, Left/physiopathology
4.
Eur Radiol ; 24(7): 1497-505, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24744197

ABSTRACT

OBJECTIVES: To measure the performance characteristics of combined T2-weighted (T2W) and diffusion-weighted (DW) magnetic resonance imaging (MRI) suspicion scoring prior to MR-transrectal ultrasound (TRUS) fusion template transperineal (TTP) re-biopsy. METHODS: Thirty-nine patients referred for prostate re-biopsy, with prior MRI examinations, were retrospectively included. The MR images, including T2W and DW-MRI, had been independently evaluated prospectively by two radiologists using a structured scoring system. An MR-TRUS fusion TTP re-biopsy was used for MR target and non-targeted biopsy cores. Targeting performance and correlation with disease status were evaluated on a per-patient and per-region basis. RESULTS: The cancer yield was 41% (16/39 patients). MR targeting accurately detected the disease in 12/16 (75%) cancerous patients and missed the disease in 4/16 (25%) patients, all with Gleason 3 + 3 disease. There was a significant relationship (P < 0.01) between MR suspicion score and the significance of cancer. Reader 1 had significantly higher sensitivity in the transition zone (TZ; 0.84) compared with the peripheral zone (PZ; 0.32) (P = 0.04). Inter-reader agreement was moderate for the PZ and substantial for the TZ. CONCLUSIONS: MRI targeting is beneficial in the setting of TTP MR-TRUS fusion re-biopsy and MR suspicion score relates to prostate cancer clinical significance. A T2W and DW-MRI structured scoring system results in good inter-reader agreement in this setting. KEY POINTS: • Pre-biopsy MRI aids the detection of high significance cancer during prostate re-biopsy. • MRI suspicion level correlates with the clinical significance of prostate cancer detected. • T2W and DW-MRI structured scoring of pre-biopsy MRI permits good inter-reader agreement.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Endosonography/methods , Image-Guided Biopsy/instrumentation , Neoplasm Staging/methods , Prostatic Neoplasms/diagnosis , Aged , Humans , Male , Middle Aged , Perineum , Reproducibility of Results , Retrospective Studies , Urethra
5.
JACC Basic Transl Sci ; 4(2): 222-233, 2019 Apr.
Article in English | MEDLINE | ID: mdl-31061924

ABSTRACT

Stunning and cumulative ischemic dysfunction occur in the left ventricle with coronary balloon occlusion. Glucagon-like peptide (GLP)-1 protects the left ventricle against this dysfunction. This study used a conductance catheter method to evaluate whether the right ventricle (RV) developed similar dysfunction during right coronary artery balloon occlusion and whether GLP-1 was protective. In this study, the RV underwent significant stunning and cumulative ischemic dysfunction with right coronary artery balloon occlusion. However, GLP-1 did not protect the RV against this dysfunction when infused after balloon occlusion.

6.
J Am Heart Assoc ; 6(6)2017 Jun 06.
Article in English | MEDLINE | ID: mdl-28588092

ABSTRACT

BACKGROUND: We sought to determine whether right ventricular stunning could be detected after supply (during coronary balloon occlusion [BO]) and supply/demand ischemia (induced by rapid pacing [RP] during transcatheter aortic valve replacement) in humans. METHODS AND RESULTS: Ten subjects with single-vessel right coronary artery disease undergoing percutaneous coronary intervention with normal ventricular function were studied in the BO group. Ten subjects undergoing transfemoral transcatheter aortic valve replacement were studied in the RP group. In both, a conductance catheter was placed into the right ventricle, and pressure volume loops were recorded at baseline and for intervals over 15 minutes after a low-pressure BO for 1 minute or a cumulative duration of RP for up to 1 minute. Ischemia-induced diastolic dysfunction was seen 1 minute after RP (end-diastolic pressure [mm Hg]: 8.1±4.2 versus 12.1±4.1, P<0.001) and BO (end-diastolic pressure [mm Hg]: 8.1±4.0 versus 8.7±4.0, P=0.03). Impairment of systolic and diastolic function after BO remained at 15-minutes recovery (ejection fraction [%]: 55.7±9.0 versus 47.8±6.3, P<0.01; end-diastolic pressure [mm Hg]: 8.1±4.0 versus 9.2±3.9, P<0.01). Persistent diastolic dysfunction was also evident in the RP group at 15-minutes recovery (end-diastolic pressure [mm Hg]: 8.1±4.1 versus 9.9±4.4, P=0.03) and there was also sustained impairment of load-independent indices of systolic function at 15 minutes after RP (end-systolic elastance and ventriculo-arterial coupling [mm Hg/mL]: 1.25±0.31 versus 0.85±0.43, P<0.01). CONCLUSIONS: RP and right coronary artery balloon occlusion both cause ischemic right ventricular dysfunction with stunning observed later during the procedure. This may have intraoperative implications in patients without right ventricular functional reserve.


Subject(s)
Aortic Valve Stenosis/surgery , Balloon Occlusion/adverse effects , Cardiac Catheterization/adverse effects , Cardiac Pacing, Artificial/adverse effects , Coronary Artery Disease/therapy , Myocardial Stunning/etiology , Ventricular Dysfunction, Right/etiology , Ventricular Function, Right , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/physiopathology , Coronary Artery Disease/diagnosis , Coronary Artery Disease/physiopathology , Female , Humans , Male , Myocardial Stunning/diagnosis , Myocardial Stunning/physiopathology , Percutaneous Coronary Intervention/adverse effects , Recovery of Function , Risk Factors , Stroke Volume , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Ventricular Dysfunction, Right/diagnosis , Ventricular Dysfunction, Right/physiopathology , Ventricular Pressure
7.
Physiol Rep ; 5(7)2017 Apr.
Article in English | MEDLINE | ID: mdl-28373412

ABSTRACT

Chronic thromboembolic disease (CTED) is suboptimally defined by a mean pulmonary artery pressure (mPAP) <25 mmHg at rest in patients that remain symptomatic from chronic pulmonary artery thrombi. To improve identification of right ventricular (RV) pathology in patients with thromboembolic obstruction, we hypothesized that the RV ventriculo-arterial (Ees/Ea) coupling ratio at maximal stroke work (Ees/Eamax sw) derived from an animal model of pulmonary obstruction may be used to identify occult RV dysfunction (low Ees/Ea) or residual RV energetic reserve (high Ees/Ea). Eighteen open chested pigs had conductance catheter RV pressure-volume (PV)-loops recorded during PA snare to determine Ees/Eamax sw This was then applied to 10 patients with chronic thromboembolic pulmonary hypertension (CTEPH) and ten patients with CTED, also assessed by RV conductance catheter and cardiopulmonary exercise testing. All patients were then restratified by Ees/Ea. The animal model determined an Ees/Eamax sw = 0.68 ± 0.23 threshold, either side of which cardiac output and RV stroke work fell. Two patients with CTED were identified with an Ees/Ea well below 0.68 suggesting occult RV dysfunction whilst three patients with CTEPH demonstrated Ees/Ea ≥ 0.68 suggesting residual RV energetic reserve. Ees/Ea > 0.68 and Ees/Ea < 0.68 subgroups demonstrated constant RV stroke work but lower stroke volume (87.7 ± 22.1 vs. 60.1 ± 16.3 mL respectively, P = 0.006) and higher end-systolic pressure (36.7 ± 11.6 vs. 68.1 ± 16.7 mmHg respectively, P < 0.001). Lower Ees/Ea in CTED also correlated with reduced exercise ventilatory efficiency. Low Ees/Ea aligns with features of RV maladaptation in CTED both at rest and on exercise. Characterization of Ees/Ea in CTED may allow for better identification of occult RV dysfunction.


Subject(s)
Pulmonary Circulation/physiology , Pulmonary Embolism/physiopathology , Ventricular Dysfunction, Right/physiopathology , Adult , Aged , Animals , Chronic Disease , Female , Humans , Hypertension, Pulmonary/physiopathology , Male , Middle Aged , Swine
8.
J Heart Lung Transplant ; 35(12): 1443-1452, 2016 12.
Article in English | MEDLINE | ID: mdl-27916176

ABSTRACT

BACKGROUND: After a severe shortage of brain-dead donors, the demand for heart transplantation has never been greater. In an attempt to increase organ supply, abdominal and lung transplant programs have turned to the donation after circulatory-determined death (DCD) donor. However, because heart function cannot be assessed after circulatory death, DCD heart transplantation was deemed high risk and never adopted routinely. We report a novel method of functional assessment of the DCD heart resulting in a successful clinical program. METHODS: Normothermic regional perfusion (NRP) was used to restore function to the arrested DCD heart within the donor after exclusion of the cerebral circulation. After weaning from support, DCD hearts underwent functional assessment with cardiac-output studies, echocardiography, and pressure-volume loops. In the feasibility phase, hearts were transported perfused before evaluation of function in modified working mode extracorporeally. After the establishment of a reliable assessment technique, hearts with demonstrable good function were then selected for clinical transplantation. RESULTS: NRP was instituted in 13 adult DCD donors, median age of 33 years (interquartile range [IQR], 28-38 years), after a median ischemic time from withdrawal to perfusion of 24 minutes (IQR, 21-29; range, 17-146 minutes). Two of 4 hearts in the feasibility phase were unsuitable for transplantation after functional assessment. Nine DCD hearts were transplanted in the clinical phase, with 100% survival. The median intensive care duration was 5 days (IQR, 4-5 days), with 2 patients requiring mechanical support. There were no episodes of rejection (total, 1,436 patient-days; range, 48-297). During the same period, we performed 20 standard heart transplants using brain-dead donors. CONCLUSIONS: NRP allows rapid reperfusion and functional assessment of the DCD donor heart, ensuring only viable hearts are selected for transplantation. This technique minimizes the risk of primary graft dysfunction and maximizes confidence in DCD heart transplantation, realizing a 45% increase in our heart transplant activity.


Subject(s)
Heart Transplantation , Adult , Humans , Perfusion , Tissue Donors , Tissue and Organ Procurement
9.
JACC Cardiovasc Interv ; 8(2): 292-301, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25700752

ABSTRACT

OBJECTIVES: This study sought to determine whether pre-treatment with intravenous glucagon-like peptide-1 (GLP-1)(7-36) amide could alter myocardial glucose use and protect the heart against ischemic left ventricular (LV) dysfunction during percutaneous coronary intervention. BACKGROUND: GLP-1 has been shown to have favorable cardioprotective effects, but its mechanisms of action remain unclear. METHODS: Twenty patients with preserved LV function and single-vessel left anterior descending coronary artery disease undergoing elective percutaneous coronary intervention were studied. A conductance catheter was placed into the LV, and pressure-volume loops were recorded at baseline, during 1-min low-pressure balloon occlusion (BO), and at 30-min recovery. Patients were randomized to receive an infusion of either GLP-1(7-36) amide at 1.2 pmol/kg/min or saline immediately after baseline measurements. Simultaneous coronary artery and coronary sinus blood sampling was performed at baseline and after BO to assess transmyocardial glucose concentration gradients. RESULTS: BO caused both ischemic LV dysfunction and stunning in the control group but not in the GLP-1 group. Compared with control subjects, the GLP-1 group had a smaller reduction in LV performance during BO (delta dP/dTmax, -4.3 vs. -19.0%, p = 0.02; delta stroke volume, -7.8 vs. -26.4%, p = 0.05), and improved LV performance at 30-min recovery. There was no difference in transmyocardial glucose concentration gradients between the 2 groups. CONCLUSIONS: Pre-treatment with GLP-1(7-36) amide protects the heart against ischemic LV dysfunction and improves the recovery of function during reperfusion. This occurs without a detected change in myocardial glucose extraction and may indicate a mechanism of action independent of an effect on cardiac substrate use. (Effect of Glucgon-Like-Peptide-1 [GLP-1] on Left Ventricular Function During Percutaneous Coronary Intervention [PCI]; ISRCTN77442023).


Subject(s)
Coronary Disease/surgery , Glucagon-Like Peptide 1/therapeutic use , Incretins/therapeutic use , Myocardial Ischemia/prevention & control , Myocardial Stunning/prevention & control , Percutaneous Coronary Intervention , Ventricular Dysfunction, Left/prevention & control , Cardiac Catheterization , Female , Glucagon-Like Peptide 1/administration & dosage , Humans , Incretins/administration & dosage , Infusions, Intravenous , Male , Middle Aged , Treatment Outcome
10.
J Appl Physiol (1985) ; 116(4): 355-63, 2014 Feb 15.
Article in English | MEDLINE | ID: mdl-24356516

ABSTRACT

Pressure-volume loops describe dynamic ventricular performance, relevant to patients with and at risk of pulmonary hypertension. We used conductance catheter-derived pressure-volume loops to measure right ventricular (RV) mechanics in patients with chronic thromboembolic pulmonary arterial obstruction at different stages of pathological adaptation. Resting conductance catheterization was performed in 24 patients: 10 with chronic thromboembolic pulmonary hypertension (CTEPH), 7 with chronic thromboembolic disease without pulmonary hypertension (CTED), and 7 controls. To assess the validity of conductance measurements, RV volumes were compared in a subset of 8 patients with contemporaneous cardiac magnetic resonance (CMR). Control, CTED, and CTEPH groups showed different pressure-volume loop morphology, most notable during systolic ejection. Prolonged diastolic relaxation was seen in patients with CTED and CTEPH [tau = 56.2 ± 6.7 (controls) vs. 69.7 ± 10.0 (CTED) vs. 67.9 ± 6.2 ms (CTEPH), P = 0.02]. Control and CTED groups had lower afterload (Ea) and contractility (Ees) compared with the CTEPH group (Ea = 0.30 ± 0.10 vs. 0.52 ± 0.24 vs. 1.92 ± 0.70 mmHg/ml, respectively, P < 0.001) (Ees = 0.44 ± 0.20 vs. 0.59 ± 0.15 vs. 1.13 ± 0.43 mmHg/ml, P < 0.01) with more efficient ventriculoarterial coupling (Ees/Ea = 1.46 ± 0.30 vs. 1.27 ± 0.36 vs. 0.60 ± 0.18, respectively, P < 0.001). Stroke volume assessed by CMR and conductance showed closest agreement (mean bias +9 ml, 95% CI -1 to +19 ml) compared with end-diastolic volume (+48 ml, -16 to 111 ml) and end-systolic volume (+37 ml, -21 to 94 ml). RV conductance catheterization detects novel alteration in pressure-volume loop morphology and delayed RV relaxation in CTED, which distinguish this group from controls. The observed agreement in stroke volume assessed by CMR and conductance suggests RV mechanics are usefully measured by conductance catheter in chronic thromboembolic obstruction.


Subject(s)
Cardiac Catheterization , Hypertension, Pulmonary/etiology , Pulmonary Artery/physiopathology , Pulmonary Embolism/complications , Stroke Volume , Ventricular Dysfunction, Right/etiology , Ventricular Function, Right , Ventricular Pressure , Adult , Aged , Arterial Pressure , Case-Control Studies , Catheterization, Swan-Ganz , Familial Primary Pulmonary Hypertension , Female , Humans , Hypertension, Pulmonary/diagnosis , Hypertension, Pulmonary/physiopathology , Magnetic Resonance Imaging , Male , Middle Aged , Predictive Value of Tests , Pulmonary Embolism/diagnosis , Pulmonary Embolism/physiopathology , Reproducibility of Results , Ventricular Dysfunction, Right/diagnosis , Ventricular Dysfunction, Right/physiopathology
12.
Ultrasound Med Biol ; 37(10): 1659-66, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21856072

ABSTRACT

This paper introduces a novel method for measuring the surface temperature of ultrasound transducer membranes and compares it with two standard measurement techniques. The surface temperature rise was measured as defined in the IEC Standard 60601-2-37. The measurement techniques were (i) thermocouple, (ii) thermal camera and (iii) novel infra-red (IR) "micro-sensor." Peak transducer surface measurements taken with the thermocouple and thermal camera were -3.7 ± 0.7 (95% CI)°C and -4.3 ± 1.8 (95% CI)°C, respectively, within the limits of the IEC Standard. Measurements taken with the novel IR micro-sensor exceeded these limits by 3.3 ± 0.9 (95% CI)°C. The ambiguity between our novel method and the standard techniques could have direct patient safety implications because the IR micro-sensor measurements were beyond set limits. The spatial resolution of the measurement technique is not well defined in the IEC Standard and this has to be taken into consideration when selecting which measurement technique is used to determine the maximum surface temperature.


Subject(s)
Thermography/instrumentation , Transducers , Ultrasonography/instrumentation , Equipment Design , Equipment Safety , Hot Temperature , Patient Safety , Temperature , Thermal Conductivity