Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 52
Filter
1.
Nature ; 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38898283

ABSTRACT

Glassy polymers are generally stiff and strong yet have limited extensibility1. By swelling with solvent, glassy polymers can become gels that are soft and weak yet have enhanced extensibility1-3. The marked changes in properties arise from the solvent increasing free volume between chains while weakening polymer-polymer interactions. Here we show that solvating polar polymers with ionic liquids (that is, ionogels4,5) at appropriate concentrations can produce a unique class of materials called glassy gels with desirable properties of both glasses and gels. The ionic liquid increases free volume and therefore extensibility despite the absence of conventional solvent (for example, water). Yet, the ionic liquid forms strong and abundant non-covalent crosslinks between polymer chains to render a stiff, tough, glassy, and homogeneous network (that is, no phase separation)6, at room temperature. Despite being more than 54 wt% liquid, the glassy gels exhibit enormous fracture strength (42 MPa), toughness (110 MJ m-3), yield strength (73 MPa) and Young's modulus (1 GPa). These values are similar to those of thermoplastics such as polyethylene, yet unlike thermoplastics, the glassy gels can be deformed up to 670% strain with full and rapid recovery on heating. These transparent materials form by a one-step polymerization and have impressive adhesive, self-healing and shape-memory properties.

2.
Proc Natl Acad Sci U S A ; 118(19)2021 05 11.
Article in English | MEDLINE | ID: mdl-33941674

ABSTRACT

Tissue-on-chip systems represent promising platforms for monitoring and controlling tissue functions in vitro for various purposes in biomedical research. The two-dimensional (2D) layouts of these constructs constrain the types of interactions that can be studied and limit their relevance to three-dimensional (3D) tissues. The development of 3D electronic scaffolds and microphysiological devices with geometries and functions tailored to realistic 3D tissues has the potential to create important possibilities in advanced sensing and control. This study presents classes of compliant 3D frameworks that incorporate microscale strain sensors for high-sensitivity measurements of contractile forces of engineered optogenetic muscle tissue rings, supported by quantitative simulations. Compared with traditional approaches based on optical microscopy, these 3D mechanical frameworks and sensing systems can measure not only motions but also contractile forces with high accuracy and high temporal resolution. Results of active tension force measurements of engineered muscle rings under different stimulation conditions in long-term monitoring settings for over 5 wk and in response to various chemical and drug doses demonstrate the utility of such platforms in sensing and modulation of muscle and other tissues. Possibilities for applications range from drug screening and disease modeling to biohybrid robotic engineering.


Subject(s)
Cell Culture Techniques, Three Dimensional/methods , Imaging, Three-Dimensional/methods , Muscles/metabolism , Tissue Engineering/methods , Tissue Scaffolds/chemistry , Acetylcholine/pharmacology , Actinin/metabolism , Animals , Caffeine/pharmacology , Cell Culture Techniques, Three Dimensional/instrumentation , Cell Differentiation , Cell Line , Dantrolene/pharmacology , Mice , Muscle, Skeletal/drug effects , Muscle, Skeletal/metabolism , Myoblasts/cytology , Myoblasts/metabolism , Myosins/metabolism , Tissue Engineering/instrumentation , Vasodilator Agents/pharmacology
3.
J Reconstr Microsurg ; 39(3): 231-237, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35952677

ABSTRACT

BACKGROUND: Commercially available near infrared spectroscopy devices for continuous free flap tissue oxygenation (StO2) monitoring can only be used on flaps with a cutaneous component. Additionally, differences in skin quality and pigmentation may alter StO2 measurements. Here, we present a novel implantable heat convection probe that measures microvascular blood flow for peripheral monitoring of free flaps, and is not subject to the same issues that limit the clinical utility of near-infrared spectroscopy. METHODS: The intratissue microvascular flow-sensing device includes a resistive heater, 4 thermistors, a small battery, and a Bluetooth chip, which allows connection to a smart device. Convection of applied heat is measured and mathematically transformed into a measurement of blood flow velocity. This was tested alongside Vioptix T.Ox in a porcine rectus abdominis myocutaneous flap model of arterial and venous occlusion. After flap elevation, the thermal device was deployed intramuscularly, and the cutaneous T.Ox device was applied. Acland clamps were alternately applied to the flap artery and veins to achieve 15 minutes periods of flap ischemia and congestion with a 15 minutes intervening recovery period. In total, five devices were tested in three flaps in three separate pigs over 16 vaso-occlusive events. RESULTS: Flow measurements were responsive to both ischemia and congestion, and returned to baseline during recovery periods. Flow measurements corresponded closely with measured StO2. Cross-correlation at zero lag showed agreement between these two sensing modalities. Two novel devices tested simultaneously on the same flap showed only minor variations in flow measurements. CONCLUSION: This novel probe is capable of detecting changes in tissue microcirculatory blood flow. This device performed well in a swine model of flap ischemia and congestion, and shows promise as a potentially useful clinical tool. Future studies will investigate performance in fasciocutaneous flaps and characterize longevity of the device over a period of several days.


Subject(s)
Free Tissue Flaps , Myocutaneous Flap , Swine , Animals , Microcirculation , Free Tissue Flaps/blood supply , Ischemia , Postoperative Complications , Arteries
4.
Nat Mater ; 20(11): 1559-1570, 2021 11.
Article in English | MEDLINE | ID: mdl-34326506

ABSTRACT

Flexible electronic/optoelectronic systems that can intimately integrate onto the surfaces of vital organ systems have the potential to offer revolutionary diagnostic and therapeutic capabilities relevant to a wide spectrum of diseases and disorders. The critical interfaces between such technologies and living tissues must provide soft mechanical coupling and efficient optical/electrical/chemical exchange. Here, we introduce a functional adhesive bioelectronic-tissue interface material, in the forms of mechanically compliant, electrically conductive, and optically transparent encapsulating coatings, interfacial layers or supporting matrices. These materials strongly bond both to the surfaces of the devices and to those of different internal organs, with stable adhesion for several days to months, in chemistries that can be tailored to bioresorb at controlled rates. Experimental demonstrations in live animal models include device applications that range from battery-free optoelectronic systems for deep-brain optogenetics and subdermal phototherapy to wireless millimetre-scale pacemakers and flexible multielectrode epicardial arrays. These advances have immediate applicability across nearly all types of bioelectronic/optoelectronic system currently used in animal model studies, and they also have the potential for future treatment of life-threatening diseases and disorders in humans.


Subject(s)
Absorbable Implants , Adhesives , Animals , Electric Conductivity , Electronics
5.
J Reconstr Microsurg ; 38(4): 321-327, 2022 May.
Article in English | MEDLINE | ID: mdl-34553344

ABSTRACT

BACKGROUND: Current near-infrared spectroscopy (NIRS)-based systems for continuous flap monitoring are limited to flaps which carry a cutaneous paddle. As such, this useful and reliable technology has not previously been applicable to muscle-only free flaps where other modalities with substantial limitations continue to be utilized. METHODS: We present the first NIRS probe which allows continuous monitoring of local tissue oxygen saturation (StO2) directly within the substance of muscle tissue. This probe is flexible, subcentimeter in scale, waterproof, biocompatible, and is fitted with resorbable barbs which facilitate temporary autostabilization followed by easy atraumatic removal. This novel device was compared with a ViOptix T.Ox monitor in a porcine rectus abdominus myocutaneous flap model of arterial and venous occlusions. During these experiments, the T.Ox device was affixed to the skin paddle, while the novel probe was within the muscle component of the same flap. RESULTS: The intramuscular NIRS device and skin-mounted ViOptix T.Ox devices produced very similar StO2 tracings throughout the vascular clamping events, with obvious and parallel changes occurring upon vascular clamping and release. The normalized cross-correlation at zero lag describing correspondence between the novel intramuscular NIRS and T.Ox devices was >0.99. CONCLUSION: This novel intramuscular NIRS probe offers continuous monitoring of oxygen saturation within muscle flaps. This experiment demonstrates the potential suitability of this intramuscular NIRS probe for the task of muscle-only free flap monitoring, where NIRS has not previously been applicable. Testing in the clinical environment is necessary to assess durability and reliability.


Subject(s)
Myocutaneous Flap , Plastic Surgery Procedures , Animals , Muscles , Oxygen , Reproducibility of Results , Spectroscopy, Near-Infrared/methods , Swine
6.
J Reconstr Microsurg ; 38(2): 96-105, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34404105

ABSTRACT

BACKGROUND: Current near-infrared spectroscopy (NIRS)-based systems for continuous flap monitoring are highly sensitive for detecting malperfusion. However, the clinical utility and user experience are limited by the wired connection between the sensor and bedside console. This wire leads to instability of the flap-sensor interface and may cause false alarms. METHODS: We present a novel wearable wireless NIRS sensor for continuous fasciocutaneous free flap monitoring. This waterproof silicone-encapsulated Bluetooth-enabled device contains two light-emitting diodes and two photodetectors in addition to a battery sufficient for 5 days of uninterrupted function. This novel device was compared with a ViOptix T.Ox monitor in a porcine rectus abdominus myocutaneous flap model of arterial and venous occlusions. RESULTS: Devices were tested in four flaps using three animals. Both devices produced very similar tissue oxygen saturation (StO2) tracings throughout the vascular clamping events, with obvious and parallel changes occurring on arterial clamping, arterial release, venous clamping, and venous release. Small interdevice variations in absolute StO2 value readings and magnitude of change were observed. The normalized cross-correlation at zero lag describing correspondence between the novel NIRS and T.Ox devices was >0.99 in each trial. CONCLUSION: The wireless NIRS flap monitor is capable of detecting StO2 changes resultant from arterial vascular occlusive events. In this porcine flap model, the functionality of this novel sensor closely mirrored that of the T.Ox wired platform. This device is waterproof, highly adhesive, skin conforming, and has sufficient battery life to function for 5 days. Clinical testing is necessary to determine if this wireless functionality translates into fewer false-positive alarms and a better user experience.


Subject(s)
Free Tissue Flaps , Myocutaneous Flap , Animals , Monitoring, Physiologic , Oxygen , Spectroscopy, Near-Infrared , Swine , Veins
7.
Adv Funct Mater ; 31(29)2021 Jul 16.
Article in English | MEDLINE | ID: mdl-36189172

ABSTRACT

Injured peripheral nerves typically exhibit unsatisfactory and incomplete functional outcomes, and there are no clinically approved therapies for improving regeneration. Post-operative electrical stimulation (ES) increases axon regrowth, but practical challenges from the cost of extended operating room time to the risks and pitfalls associated with transcutaneous wire placement have prevented broad clinical adoption. This study presents a possible solution in the form of advanced bioresorbable materials for thin, flexible, wireless implant that provides precisely controlled ES of the injured nerve for a brief time in the immediate post-operative period. Afterward, rapid, complete and safe modes of bioresorption naturally and quickly eliminate all of the constituent materials in their entirety, without the need for surgical extraction. The unusually high rate of bioresorption follows from the use of a unique, bilayer enclosure that combines two distinct formulations of a biocompatible form of polyanhydride as an encapsulating structure, to accelerate the resorption of active components and confine fragments until complete resorption. Results from mouse models of tibial nerve transection with re-anastomosis indicate that this system offers levels of performance and efficacy that match those of conventional wired stimulators, but without the need to extend the operative period or to extract the device hardware.

8.
Nat Mater ; 19(6): 590-603, 2020 06.
Article in English | MEDLINE | ID: mdl-32461684

ABSTRACT

Engineered systems that can serve as chronically stable, high-performance electronic recording and stimulation interfaces to the brain and other parts of the nervous system, with cellular-level resolution across macroscopic areas, are of broad interest to the neuroscience and biomedical communities. Challenges remain in the development of biocompatible materials and the design of flexible implants for these purposes, where ulimate goals are for performance attributes approaching those of conventional wafer-based technologies and for operational timescales reaching the human lifespan. This Review summarizes recent advances in this field, with emphasis on active and passive constituent materials, design architectures and integration methods that support necessary levels of biocompatibility, electronic functionality, long-term stable operation in biofluids and reliability for use in vivo. Bioelectronic systems that enable multiplexed electrophysiological mapping across large areas at high spatiotemporal resolution are surveyed, with a particular focus on those with proven chronic stability in live animal models and scalability to thousands of channels over human-brain-scale dimensions. Research in materials science will continue to underpin progress in this field of study.


Subject(s)
Biocompatible Materials , Electronics , Prostheses and Implants , Animals , Humans
9.
Nat Mater ; 17(3): 268-276, 2018 03.
Article in English | MEDLINE | ID: mdl-29379201

ABSTRACT

Three-dimensional (3D) structures capable of reversible transformations in their geometrical layouts have important applications across a broad range of areas. Most morphable 3D systems rely on concepts inspired by origami/kirigami or techniques of 3D printing with responsive materials. The development of schemes that can simultaneously apply across a wide range of size scales and with classes of advanced materials found in state-of-the-art microsystem technologies remains challenging. Here, we introduce a set of concepts for morphable 3D mesostructures in diverse materials and fully formed planar devices spanning length scales from micrometres to millimetres. The approaches rely on elastomer platforms deformed in different time sequences to elastically alter the 3D geometries of supported mesostructures via nonlinear mechanical buckling. Over 20 examples have been experimentally and theoretically investigated, including mesostructures that can be reshaped between different geometries as well as those that can morph into three or more distinct states. An adaptive radiofrequency circuit and a concealable electromagnetic device provide examples of functionally reconfigurable microelectronic devices.

10.
Nanotechnology ; 28(14): 145301, 2017 Apr 07.
Article in English | MEDLINE | ID: mdl-28221161

ABSTRACT

The self-assembly of block copolymers with large feature sizes is inherently challenging as the large kinetic barrier arising from chain entanglement of high molecular weight (MW) polymers limits the extent over which long-range ordered microdomains can be achieved. Here, we illustrate the evolution of thin film morphology from a diblock copolymer of polystyrene-block-poly(dimethylsiloxane) exhibiting total number average MW of 123 kg mol-1, and demonstrate the formation of layers of well-ordered cylindrical microdomains under appropriate conditions of binary solvent mix ratio, commensurate film thickness, and solvent vapor annealing time. Directed self-assembly of the block copolymer within lithographically patterned trenches occurs with alignment of cylinders parallel to the sidewalls. Fabrication of ordered cobalt nanowire arrays by pattern transfer was also implemented, and their magnetic properties and domain wall behavior were characterized.

11.
Soft Matter ; 12(21): 4866-74, 2016 May 25.
Article in English | MEDLINE | ID: mdl-27136891

ABSTRACT

We report the effect of electric field on the morphological transitions and ordering behavior of polyferrocenylethylmethylsilane block (PFEMS)-containing copolymers. By analyzing structures in solvent-annealed films of metalorganic sphere- and cylinder-forming diblock copolymers, as well as of 3-miktoarm polyisoprene-arm-polystyrene-arm-PFEMS (3µ-ISF) terpolymers, we decouple two types of responses to the electric field: morphological transformations as a result of an increase in the volume fraction of the PFEMS block by oxidation of the ferrocenyl groups, and the orientation of the dielectric interfaces of microdomains parallel to the electric field vector. In the case of 3µ-ISF, the former effect dominates at high electric field strengths which results in an unexpected cylinder-to-sphere transition, leading to a well-ordered hexagonal dot pattern. Our results demonstrate multiple tunability of ordered microdomain morphologies, suggesting future applications in nanofabrication and surface patterning.

12.
Nanotechnology ; 27(46): 465301, 2016 Nov 18.
Article in English | MEDLINE | ID: mdl-27736809

ABSTRACT

The response of polystyrene-block-poly(dimethylsiloxane) (PS-b-PDMS) thin films to UV exposure during solvent vapor annealing is described, in order to improve their applicability in nanolithography and nanofabrication. Two BCPs were examined, one with the PS block as majority (f PS = 68%, M n = 53 kg mol-1), the other with PDMS block as majority (f PDMS = 67%, M n = 44 kg mol-1). A 5 min UV irradiation was applied during solvent vapor annealing which led to both partial crosslinking of the polymer and a small increase in the temperature of the annealing chamber. This approach was effective for improving the correlation length of the self-assembled microdomain arrays and in limiting subsequent flow of the PDMS in the PDMS-majority BCP to preserve the post-anneal morphology. Ordering and orientation of microdomains were controlled by directed self-assembly of the BCPs in trench substrates. Highly-ordered perpendicular nanochannel arrays were obtained in the PDMS-majority BCP.

13.
Nano Lett ; 15(10): 6901-8, 2015 Oct 14.
Article in English | MEDLINE | ID: mdl-26390190

ABSTRACT

Perpendicular orientation of lamellar microdomains in a high interaction parameter block copolymer was obtained within high aspect ratio gratings functionalized with a preferential sidewall brush. The experiments used polystyrene-block-polydimethylsiloxane (PS-b-PDMS) with molecular weight 43 kg/mol within trenches made using interference lithography. The perpendicular alignment was obtained for both thermal and solvent annealing, using three different solvent vapors, for a range of film thicknesses and trench widths. A platinum (Pt) layer at the base of the trenches avoided the formation of a wetting layer, giving perpendicular orientation at the substrate surface. The results are interpreted using self-consistent field theory simulation and a Ginzburg-Landau analytic model to map the energies of lamellae of different orientations as a function of the grating aspect ratio and the surface energies of the sidewalls and top and bottom surfaces. The model results agree with the experiment and provide a set of guidelines for obtaining perpendicular microdomains within topographic features.

14.
Nanotechnology ; 26(37): 375301, 2015 Sep 18.
Article in English | MEDLINE | ID: mdl-26302968

ABSTRACT

A universal block copolymer pattern transfer method was demonstrated to produce Co nanostructures consisting of arrays of lines or dots from a polystyrene-block-polydimethylsiloxane (PS-b-PDMS) diblock copolymer. Three processes were used: liftoff, a damascene process, and ion beam etching using a hard mask of tungsten, including a sacrificial poly(methyl methacrylate) layer under the PS-b-PDMS for the etch and liftoff processes. The ion beam etch process produced the most uniform magnetic arrays. A structural and magnetic comparison in terms of uniformity, edge roughness and switching field distribution has been reported.

15.
Nano Lett ; 14(1): 318-25, 2014 Jan 08.
Article in English | MEDLINE | ID: mdl-24328687

ABSTRACT

An inverse design algorithm has been developed that predicts the necessary topographical template needed to direct the self-assembly of a diblock copolymer to produce a given complex target structure. The approach is optimized by varying the number of topographical posts, post size, and block copolymer volume fraction to yield a template solution that generates the target structure in a reproducible manner. The inverse algorithm is implemented computationally to predict post arrangements that will template two different target structures and the predicted templates are tested experimentally with a polydimethylsiloxane-b-polystyrene block copolymer. Simulated and experimental results show overall very good agreement despite the complexity of the patterns. The templates determined from the model can be used in developing simpler design rules for block copolymer directed self-assembly.

16.
Lab Chip ; 24(13): 3294-3304, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38864519

ABSTRACT

On-demand drug delivery holds great promise to optimize pharmaceutical efficacy while minimizing the side effects. However, existing on-demand drug delivery systems often require complicated manufacturing processes that preclude their wide implementation of a broad range of drugs. In this work, we demonstrate the introduction of MXene-coated microneedles (MNs) into bioelectronics for digitally controllable gate-valve drug delivery. MXenes, featuring high electronic conductivity, excellent biocompatibility, and solution processibility, enable low-cost scalability for printable bioelectronics. In an electrolytic state (e.g., body fluid), the coated MXene is oxidized and desorbed due to redox reactions caused by electrical bias, allowing the underlying drug to be controllably released. The MXene-incorporated drug delivery system not only demonstrates excellent biocompatibility and operational stability, but also features low-cost construction and sustainable usage. Besides, these MXene-coated MNs allow both on-demand transformation and local-region customization, further increasing the structural versatility and capability of multidrug delivery systems.


Subject(s)
Drug Delivery Systems , Electric Conductivity , Drug Delivery Systems/instrumentation , Water/chemistry , Humans , Equipment Design
17.
Nat Commun ; 15(1): 511, 2024 Jan 13.
Article in English | MEDLINE | ID: mdl-38218967

ABSTRACT

Transdermal drug delivery is of vital importance for medical treatments. However, user adherence to long-term repetitive drug delivery poses a grand challenge. Furthermore, the dynamic and unpredictable disease progression demands a pharmaceutical treatment that can be actively controlled in real-time to ensure medical precision and personalization. Here, we report a spatiotemporal on-demand patch (SOP) that integrates drug-loaded microneedles with biocompatible metallic membranes to enable electrically triggered active control of drug release. Precise control of drug release to targeted locations (<1 mm2), rapid drug release response to electrical triggers (<30 s), and multi-modal operation involving both drug release and electrical stimulation highlight the novelty. Solution-based fabrication ensures high customizability and scalability to tailor the SOP for various pharmaceutical needs. The wireless-powered and digital-controlled SOP demonstrates great promise in achieving full automation of drug delivery, improving user adherence while ensuring medical precision. Based on these characteristics, we utilized SOPs in sleep studies. We revealed that programmed release of exogenous melatonin from SOPs improve sleep of mice, indicating potential values for basic research and clinical treatments.


Subject(s)
Drug Delivery Systems , Skin , Animals , Mice , Skin/metabolism , Administration, Cutaneous , Pharmaceutical Preparations/metabolism , Drug Liberation , Needles
18.
Nat Commun ; 15(1): 4777, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38839748

ABSTRACT

Drawing inspiration from cohesive integration of skeletal muscles and sensory skins in vertebrate animals, we present a design strategy of soft robots, primarily consisting of an electronic skin (e-skin) and an artificial muscle. These robots integrate multifunctional sensing and on-demand actuation into a biocompatible platform using an in-situ solution-based method. They feature biomimetic designs that enable adaptive motions and stress-free contact with tissues, supported by a battery-free wireless module for untethered operation. Demonstrations range from a robotic cuff for detecting blood pressure, to a robotic gripper for tracking bladder volume, an ingestible robot for pH sensing and on-site drug delivery, and a robotic patch for quantifying cardiac function and delivering electrotherapy, highlighting the application versatilities and potentials of the bio-inspired soft robots. Our designs establish a universal strategy with a broad range of sensing and responsive materials, to form integrated soft robots for medical technology and beyond.


Subject(s)
Robotics , Robotics/instrumentation , Robotics/methods , Animals , Biomimetics/methods , Biomimetics/instrumentation , Humans , Prostheses and Implants , Skin , Equipment Design , Muscle, Skeletal/physiology , Wearable Electronic Devices
19.
Sci Adv ; 10(16): eadj0268, 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38640247

ABSTRACT

Continuous monitoring of biomarkers at locations adjacent to targeted internal organs can provide actionable information about postoperative status beyond conventional diagnostic methods. As an example, changes in pH in the intra-abdominal space after gastric surgeries can serve as direct indicators of potentially life-threatening leakage events, in contrast to symptomatic reactions that may delay treatment. Here, we report a bioresorbable, wireless, passive sensor that addresses this clinical need, designed to locally monitor pH for early detection of gastric leakage. A pH-responsive hydrogel serves as a transducer that couples to a mechanically optimized inductor-capacitor circuit for wireless readout. This platform enables real-time monitoring of pH with fast response time (within 1 hour) over a clinically relevant period (up to 7 days) and timely detection of simulated gastric leaks in animal models. These concepts have broad potential applications for temporary sensing of relevant biomarkers during critical risk periods following diverse types of surgeries.


Subject(s)
Absorbable Implants , Transducers , Animals , Wireless Technology , Hydrogen-Ion Concentration , Biomarkers
20.
Adv Mater ; 36(15): e2307782, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38303684

ABSTRACT

Bio/ecoresorbable electronic systems create unique opportunities in implantable medical devices that serve a need over a finite time period and then disappear naturally to eliminate the need for extraction surgeries. A critical challenge in the development of this type of technology is in materials that can serve as thin, stable barriers to surrounding ground water or biofluids, yet ultimately dissolve completely to benign end products. This paper describes a class of inorganic material (silicon oxynitride, SiON) that can be formed in thin films by plasma-enhanced chemical vapor deposition for this purpose. In vitro studies suggest that SiON and its dissolution products are biocompatible, indicating the potential for its use in implantable devices. A facile process to fabricate flexible, wafer-scale multilayer films bypasses limitations associated with the mechanical fragility of inorganic thin films. Systematic computational, analytical, and experimental studies highlight the essential materials aspects. Demonstrations in wireless light-emitting diodes both in vitro and in vivo illustrate the practical use of these materials strategies. The ability to select degradation rates and water permeability through fine tuning of chemical compositions and thicknesses provides the opportunity to obtain a range of functional lifetimes to meet different application requirements.


Subject(s)
Absorbable Implants , Electronics , Water/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL