Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 110
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Neuroimage ; 278: 120272, 2023 09.
Article in English | MEDLINE | ID: mdl-37437701

ABSTRACT

Quantitative Susceptibility Mapping (QSM) is a recent MRI-technique able to quantify the bulk magnetic susceptibility of myelin, iron, and calcium in the brain. Its variability across different acquisition parameters has prompted the need for standardisation across multiple centres and MRI vendors. However, a high level of agreement between repeated imaging acquisitions is equally important. With this study we aimed to assess the inter-scan repeatability of an optimised multi-echo GRE sequence in 28 healthy volunteers. We extracted and compared the susceptibility measures from the scan and rescan acquisitions across 7 bilateral brain regions (i.e., 14 regions of interest (ROIs)) relevant for neurodegeneration. Repeatability was first assessed while reconstructing QSM with a fixed number of echo times (i.e., 8). Excellent inter-scan repeatability was found for putamen, globus pallidus and caudate nucleus, while good performance characterised the remaining structures. An increased variability was instead noted for small ROIs like red nucleus and substantia nigra. Secondly, we assessed the impact exerted on repeatability by the number of echoes used to derive QSM maps. Results were impacted by this parameter, especially in smaller regions. Larger brain structures, on the other hand, showed more consistent performance. Nevertheless, with either 8 or 7 echoes we managed to obtain good inter-scan repeatability on almost all ROIs. These findings indicate that the designed acquisition/reconstruction protocol has wide applicability, particularly in clinical or research settings involving longitudinal acquisitions (e.g. rehabilitation studies).


Subject(s)
Brain Mapping , Brain , Humans , Brain Mapping/methods , Brain/diagnostic imaging , Gray Matter , Basal Ganglia/diagnostic imaging , Substantia Nigra/diagnostic imaging , Magnetic Resonance Imaging/methods
2.
Neuroimage ; 284: 120457, 2023 Dec 15.
Article in English | MEDLINE | ID: mdl-37977407

ABSTRACT

BACKGROUND: The emotional domain is often impaired across many neurological diseases, for this reason it represents a relevant target of rehabilitation interventions. Functional changes in neural activity related to treatment can be assessed with functional MRI (fMRI) using emotion-generation tasks in longitudinal settings. Previous studies demonstrated that within-subject fMRI signal reliability can be affected by several factors such as repetition suppression, type of task and brain anatomy. However, the differential role of repetition suppression and emotional valence of the stimuli on the fMRI signal reliability and reproducibility during an emotion-generation task involving the vision of emotional pictures is yet to be determined. METHODS: Sixty-two healthy subjects were enrolled and split into two groups: group A (21 subjects, test-retest reliability on same-day and with same-task-form), group B (30 subjects, test-retest reproducibility with 4-month-interval using two equivalent-parallel forms of the task). Test-retest reliability and reproducibility of fMRI responses and patterns were evaluated separately for positive and negative emotional valence conditions in both groups. The analyses were performed voxel-wise, using the general linear model (GLM), and via a region-of-interest (ROI)-based approach, by computing the intra-class correlation coefficient (ICC) on the obtained contrasts. RESULTS: The voxel-wise GLM test yielded no significant differences for both conditions in reliability and reproducibility analyses. As to the ROI-based approach, across all areas with significant main effects of the stimuli, the reliability, as measured with ICC, was poor (<0.4) for the positive condition and ranged from poor to excellent (0.4-0.75) for the negative condition. The ICC-based reproducibility analysis, related to the comparison of two different parallel forms, yielded similar results. DISCUSSION: The voxel-wise GLM analysis failed to capture the poor reliability of fMRI signal which was instead highlighted using the ROI-based ICC analysis. The latter showed higher signal reliability for negative valence stimuli with respect to positive ones. The implementation of two parallel forms allowed to exclude neural suppression as the predominant effect causing low signal reliability, which could be instead ascribed to the employment of different neural strategies to cope with emotional stimuli over time. This is an invaluable information for a better assessment of treatment and rehabilitation effects in longitudinal studies of emotional neural processing.


Subject(s)
Habituation, Psychophysiologic , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Reproducibility of Results , Brain/diagnostic imaging , Brain/physiology , Emotions/physiology , Brain Mapping/methods
3.
Eur Radiol ; 33(10): 6746-6755, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37160426

ABSTRACT

OBJECTIVE: Breast arterial calcifications (BAC) are a sex-specific cardiovascular disease biomarker that might improve cardiovascular risk stratification in women. We implemented a deep convolutional neural network for automatic BAC detection and quantification. METHODS: In this retrospective study, four readers labelled four-view mammograms as BAC positive (BAC+) or BAC negative (BAC-) at image level. Starting from a pretrained VGG16 model, we trained a convolutional neural network to discriminate BAC+ and BAC- mammograms. Accuracy, F1 score, and area under the receiver operating characteristic curve (AUC-ROC) were used to assess the diagnostic performance. Predictions of calcified areas were generated using the generalized gradient-weighted class activation mapping (Grad-CAM++) method, and their correlation with manual measurement of BAC length in a subset of cases was assessed using Spearman ρ. RESULTS: A total 1493 women (198 BAC+) with a median age of 59 years (interquartile range 52-68) were included and partitioned in a training set of 410 cases (1640 views, 398 BAC+), validation set of 222 cases (888 views, 89 BAC+), and test set of 229 cases (916 views, 94 BAC+). The accuracy, F1 score, and AUC-ROC were 0.94, 0.86, and 0.98 in the training set; 0.96, 0.74, and 0.96 in the validation set; and 0.97, 0.80, and 0.95 in the test set, respectively. In 112 analyzed views, the Grad-CAM++ predictions displayed a strong correlation with BAC measured length (ρ = 0.88, p < 0.001). CONCLUSION: Our model showed promising performances in BAC detection and in quantification of BAC burden, showing a strong correlation with manual measurements. CLINICAL RELEVANCE STATEMENT: Integrating our model to clinical practice could improve BAC reporting without increasing clinical workload, facilitating large-scale studies on the impact of BAC as a biomarker of cardiovascular risk, raising awareness on women's cardiovascular health, and leveraging mammographic screening. KEY POINTS: • We implemented a deep convolutional neural network (CNN) for BAC detection and quantification. • Our CNN had an area under the receiving operator curve of 0.95 for BAC detection in the test set composed of 916 views, 94 of which were BAC+ . • Furthermore, our CNN showed a strong correlation with manual BAC measurements (ρ = 0.88) in a set of 112 views.


Subject(s)
Breast Diseases , Cardiovascular Diseases , Deep Learning , Female , Humans , Middle Aged , Retrospective Studies , Mammography/methods , Breast Diseases/diagnostic imaging
4.
Sensors (Basel) ; 23(4)2023 Feb 13.
Article in English | MEDLINE | ID: mdl-36850685

ABSTRACT

Functional near-infrared spectroscopy (fNIRS) is an important non-invasive technique used to monitor cortical activity. However, a varying sensitivity of surface channels vs. cortical structures may suggest integrating the fNIRS with the subject-specific anatomy (SSA) obtained from routine MRI. Actual processing tools permit the computation of the SSA forward problem (i.e., cortex to channel sensitivity) and next, a regularized solution of the inverse problem to map the fNIRS signals onto the cortex. The focus of this study is on the analysis of the forward problem to quantify the effect of inter-subject variability. Thirteen young adults (six males, seven females, age 29.3 ± 4.3) underwent both an MRI scan and a motor grasping task with a continuous wave fNIRS system of 102 measurement channels with optodes placed according to a 10/5 system. The fNIRS sensitivity profile was estimated using Monte Carlo simulations on each SSA and on three major atlases (i.e., Colin27, ICBM152 and FSAverage) for comparison. In each SSA, the average sensitivity curves were obtained by aligning the 102 channels and segmenting them by depth quartiles. The first quartile (depth < 11.8 (0.7) mm, median (IQR)) covered 0.391 (0.087)% of the total sensitivity profile, while the second one (depth < 13.6 (0.7) mm) covered 0.292 (0.009)%, hence indicating that about 70% of the signal was from the gyri. The sensitivity bell-shape was broad in the source-detector direction (20.953 (5.379) mm FWHM, first depth quartile) and steeper in the transversal one (6.082 (2.086) mm). The sensitivity of channels vs. different cortical areas based on SSA were analyzed finding high dispersions among subjects and large differences with atlas-based evaluations. Moreover, the inverse cortical mapping for the grasping task showed differences between SSA and atlas based solutions. In conclusion, integration with MRI SSA can significantly improve fNIRS interpretation.


Subject(s)
Magnetic Resonance Imaging , Female , Male , Young Adult , Humans , Adult , Monte Carlo Method , Spectrum Analysis
5.
Radiol Med ; 128(5): 544-555, 2023 May.
Article in English | MEDLINE | ID: mdl-37093337

ABSTRACT

OBJECTIVES: The aim of the present systematic review and meta-analysis is to assess the accuracy of automated landmarking using deep learning in comparison with manual tracing for cephalometric analysis of 3D medical images. METHODS: PubMed/Medline, IEEE Xplore, Scopus and ArXiv electronic databases were searched. Selection criteria were: ex vivo and in vivo volumetric data images suitable for 3D landmarking (Problem), a minimum of five automated landmarking performed by deep learning method (Intervention), manual landmarking (Comparison), and mean accuracy, in mm, between manual and automated landmarking (Outcome). QUADAS-2 was adapted for quality analysis. Meta-analysis was performed on studies that reported as outcome mean values and standard deviation of the difference (error) between manual and automated landmarking. Linear regression plots were used to analyze correlations between mean accuracy and year of publication. RESULTS: The initial electronic screening yielded 252 papers published between 2020 and 2022. A total of 15 studies were included for the qualitative synthesis, whereas 11 studies were used for the meta-analysis. Overall random effect model revealed a mean value of 2.44 mm, with a high heterogeneity (I2 = 98.13%, τ2 = 1.018, p-value < 0.001); risk of bias was high due to the presence of issues for several domains per study. Meta-regression indicated a significant relation between mean error and year of publication (p value = 0.012). CONCLUSION: Deep learning algorithms showed an excellent accuracy for automated 3D cephalometric landmarking. In the last two years promising algorithms have been developed and improvements in landmarks annotation accuracy have been done.


Subject(s)
Deep Learning , Humans , Anatomic Landmarks , Reproducibility of Results , Cephalometry/methods , Imaging, Three-Dimensional/methods , Algorithms
6.
Sensors (Basel) ; 22(14)2022 Jul 15.
Article in English | MEDLINE | ID: mdl-35890975

ABSTRACT

Sleep disorders are a growing threat nowadays as they are linked to neurological, cardiovascular and metabolic diseases. The gold standard methodology for sleep study is polysomnography (PSG), an intrusive and onerous technique that can disrupt normal routines. In this perspective, m-Health technologies offer an unobtrusive and rapid solution for home monitoring. We developed a multi-scale method based on motion signal extracted from an unobtrusive device to evaluate sleep behavior. Data used in this study were collected during two different acquisition campaigns by using a Pressure Bed Sensor (PBS). The first one was carried out with 22 subjects for sleep problems, and the second one comprises 11 healthy shift workers. All underwent full PSG and PBS recordings. The algorithm consists of extracting sleep quality and fragmentation indexes correlating to clinical metrics. In particular, the method classifies sleep windows of 1-s of the motion signal into: displacement (DI), quiet sleep (QS), disrupted sleep (DS) and absence from the bed (ABS). QS proved to be positively correlated (0.72±0.014) to Sleep Efficiency (SE) and DS/DI positively correlated (0.85±0.007) to the Apnea-Hypopnea Index (AHI). The work proved to be potentially helpful in the early investigation of sleep in the home environment. The minimized intrusiveness of the device together with a low complexity and good performance might provide valuable indications for the home monitoring of sleep disorders and for subjects' awareness.


Subject(s)
Sleep Apnea Syndromes , Sleep Apnea, Obstructive , Humans , Polysomnography , Sleep , Sleep Quality
7.
Int J Mol Sci ; 23(23)2022 Nov 28.
Article in English | MEDLINE | ID: mdl-36499223

ABSTRACT

Functional near-infrared spectroscopy (fNIRS) is increasingly employed as an ecological neuroimaging technique in assessing age-related chronic neurological disorders, such as Parkinson's disease (PD), mainly providing a cross-sectional characterization of clinical phenotypes in ecological settings. Current fNIRS studies in PD have investigated the effects of motor and non-motor impairment on cortical activity during gait and postural stability tasks, but no study has employed fNIRS as an ecological neuroimaging tool to assess PD at different stages. Therefore, in this work, we sought to investigate the cortical activity of PD patients during a motor grasping task and its relationship with both the staging of the pathology and its clinical variables. This study considered 39 PD patients (age 69.0 ± 7.64, 38 right-handed), subdivided into two groups at different stages by the Hoehn and Yahr (HY) scale: early PD (ePD; N = 13, HY = [1; 1.5]) and moderate PD (mPD; N = 26, HY = [2; 2.5; 3]). We employed a whole-head fNIRS system with 102 measurement channels to monitor brain activity. Group-level activation maps and region of interest (ROI) analysis were computed for ePD, mPD, and ePD vs. mPD contrasts. A ROI-based correlation analysis was also performed with respect to contrasted subject-level fNIRS data, focusing on age, a Cognitive Reserve Index questionnaire (CRIQ), disease duration, the Unified Parkinson's Disease Rating Scale (UPDRS), and performances in the Stroop Color and Word (SCW) test. We observed group differences in age, disease duration, and the UPDRS, while no significant differences were found for CRIQ or SCW scores. Group-level activation maps revealed that the ePD group presented higher activation in motor and occipital areas than the mPD group, while the inverse trend was found in frontal areas. Significant correlations with CRIQ, disease duration, the UPDRS, and the SCW were mostly found in non-motor areas. The results are in line with current fNIRS and functional and anatomical MRI scientific literature suggesting that non-motor areas-primarily the prefrontal cortex area-provide a compensation mechanism for PD motor impairment. fNIRS may serve as a viable support for the longitudinal assessment of therapeutic and rehabilitation procedures, and define new prodromal, low-cost, and ecological biomarkers of disease progression.


Subject(s)
Parkinson Disease , Humans , Parkinson Disease/diagnostic imaging , Parkinson Disease/psychology , Spectroscopy, Near-Infrared/methods , Cross-Sectional Studies , Gait , Prefrontal Cortex/physiology
8.
BMC Oral Health ; 22(1): 98, 2022 03 30.
Article in English | MEDLINE | ID: mdl-35351080

ABSTRACT

BACKGROUND: Cephalometric analysis is traditionally performed on skull lateral teleradiographs for orthodontic diagnosis and treatment planning. However, the skull flattened over a 2D film presents projection distortions and superimpositions to various extents depending on landmarks relative position. When a CBCT scan is indicated for mixed reasons, cephalometric assessments can be performed directly on CBCT scans with a distortion free procedure. The aim of the present study is to compare these two methods for orthodontic cephalometry. METHODS: 114 CBCTs were selected, reconstructed lateral cephalometries were obtained by lateral radiographic projection of the entire volume from the right and left sides. 2D and 3D cephalometric tracings were performed. Since paired t-tests between left and right-side measurements found no statistically significant differences, mean values between sides were considered for both 2D and 3D values. The following measurements were evaluated: PNS-A; S-N; N-Me; N-ANS; ANS-Me; Go-Me; Go-S; Go-Co; SNA, SNB, ANB; BaSN; S-N^PNS-ANS; PNS-ANS^Go-Me; S-N^Go-Me. Intraclass correlation coefficients, paired t-test, correlation coefficient and Bland-Altman analysis were performed to compare these techniques. RESULTS: The values of intra- and inter-rater ICC showed excellent repeatability and reliability: the average (± SD) intraobserver ICCs were 0.98 (± 0.01) and 0.97(± 0.01) for CBCT and RLCs, respectively; Inter-rater reliability resulted in an average ICC (± SD) of 0.98 (± 0.01) for CBCT and 0.94 (± 0.03) for RLC. The paired t-tests between CBCT and reconstructed lateral cephalograms revealed that Go-Me, Go-S, PNS-ANS^Go-Me and S-N^Go-Me measurements were statistically different between the two modalities. All the evaluated sets of measurements showed strong positive correlation; the bias and ranges for the 95% Limits of Agreement showed higher levels of agreement between the two modalities for unpaired measurements with respect to bilateral ones. CONCLUSION: The cephalometric measurements laying on the mid-sagittal plane can be evaluated on CBCT and used for orthodontic diagnosis as they do not show statistically significant differences with those measured on 2D lateral cephalograms. For measurements that are not in the mid-sagittal plane, the future development of specific algorithms for distortion correction could help clinicians deduct all the information needed for orthodontic diagnosis from the CBCT scan.


Subject(s)
Spiral Cone-Beam Computed Tomography , Cephalometry/methods , Cone-Beam Computed Tomography/methods , Cross-Sectional Studies , Humans , Imaging, Three-Dimensional/methods , Reproducibility of Results
9.
Neuroimage ; 237: 118189, 2021 08 15.
Article in English | MEDLINE | ID: mdl-34022383

ABSTRACT

Large scale neuroimaging datasets present the possibility of providing normative distributions for a wide variety of neuroimaging markers, which would vastly improve the clinical utility of these measures. However, a major challenge is our current poor ability to integrate measures across different large-scale datasets, due to inconsistencies in imaging and non-imaging measures across the different protocols and populations. Here we explore the harmonisation of white matter hyperintensity (WMH) measures across two major studies of healthy elderly populations, the Whitehall II imaging sub-study and the UK Biobank. We identify pre-processing strategies that maximise the consistency across datasets and utilise multivariate regression to characterise study sample differences contributing to differences in WMH variations across studies. We also present a parser to harmonise WMH-relevant non-imaging variables across the two datasets. We show that we can provide highly calibrated WMH measures from these datasets with: (1) the inclusion of a number of specific standardised processing steps; and (2) appropriate modelling of sample differences through the alignment of demographic, cognitive and physiological variables. These results open up a wide range of applications for the study of WMHs and other neuroimaging markers across extensive databases of clinical data.


Subject(s)
Aging , Biomedical Research , Datasets as Topic , Leukoaraiosis , Multicenter Studies as Topic , Neuroimaging , Adult , Aged , Aged, 80 and over , Biological Specimen Banks , Female , Humans , Leukoaraiosis/diagnostic imaging , Longitudinal Studies , Male , Middle Aged , United Kingdom
10.
J Magn Reson Imaging ; 53(6): 1732-1743, 2021 06.
Article in English | MEDLINE | ID: mdl-33345393

ABSTRACT

BACKGROUND: Although white matter hyperintensities (WMH) volumetric assessment is now customary in research studies, inconsistent WMH measures among homogenous populations may prevent the clinical usability of this biomarker. PURPOSE: To determine whether a point estimate and reference standard for WMH volume in the healthy aging population could be determined. STUDY TYPE: Systematic review and meta-analysis. POPULATION: In all, 9716 adult subjects from 38 studies reporting WMH volume were retrieved following a systematic search on EMBASE. FIELD STRENGTH/SEQUENCE: 1.0T, 1.5T, or 3.0T/fluid-attenuated inversion recovery (FLAIR) and/or proton density/T2 -weighted fast spin echo sequences or gradient echo T1 -weighted sequences. ASSESSMENT: After a literature search, sample size, demographics, magnetic field strength, MRI sequences, level of automation in WMH assessment, study population, and WMH volume were extracted. STATISTICAL TESTS: The pooled WMH volume with 95% confidence interval (CI) was calculated using the random-effect model. The I2 statistic was calculated as a measure of heterogeneity across studies. Meta-regression analysis of WMH volume on age was performed. RESULTS: Of the 38 studies analyzed, 17 reported WMH volume as the mean and standard deviation (SD) and were included in the meta-analysis. Mean and SD of age was 66.11 ± 10.92 years (percentage of men 50.45% ± 21.48%). Heterogeneity was very high (I2  = 99%). The pooled WMH volume was 4.70 cm3 (95% CI: 3.88-5.53 cm3 ). At meta-regression analysis, WMH volume was positively associated with subjects' age (ß = 0.358 cm3 per year, P < 0.05, R2  = 0.27). DATA CONCLUSION: The lack of standardization in the definition of WMH together with the high technical variability in assessment may explain a large component of the observed heterogeneity. Currently, volumes of WMH in healthy subjects are not comparable between studies and an estimate and reference interval could not be determined. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Subject(s)
White Matter , Adult , Aged , Humans , Magnetic Resonance Imaging , Male , Middle Aged , White Matter/diagnostic imaging
11.
Molecules ; 25(18)2020 Sep 06.
Article in English | MEDLINE | ID: mdl-32899982

ABSTRACT

Proteomic technologies have identified 234 peptidases in plasma but little quantitative information about the proteolytic activity has been uncovered. In this study, the substrate profile of plasma proteases was evaluated using two nano-LC-ESI-MS/MS methods. Multiplex substrate profiling by mass spectrometry (MSP-MS) quantifies plasma protease activity in vitro using a global and unbiased library of synthetic peptide reporter substrates, and shotgun peptidomics quantifies protein degradation products that have been generated in vivo by proteases. The two approaches gave complementary results since they both highlight key peptidase activities in plasma including amino- and carboxypeptidases with different substrate specificity profiles. These assays provide a significant advantage over traditional approaches, such as fluorogenic peptide reporter substrates, because they can detect active plasma proteases in a global and unbiased manner, in comparison to detecting select proteases using specific reporter substrates. We discovered that plasma proteins are cleaved by endoproteases and these peptide products are subsequently degraded by amino- and carboxypeptidases. The exopeptidases are more active and stable in plasma and therefore were found to be the most active proteases in the in vitro assay. The protocols presented here set the groundwork for studies to evaluate changes in plasma proteolytic activity in shock.


Subject(s)
Peptide Hydrolases/blood , Tandem Mass Spectrometry/methods , Amino Acid Sequence , Animals , Peptide Hydrolases/chemistry , Proteomics , Substrate Specificity , Swine
12.
Radiology ; 289(3): 788-796, 2018 12.
Article in English | MEDLINE | ID: mdl-30277427

ABSTRACT

Purpose The primary aim of this prospective observational study was to assess whether diffusion MRI metrics correlate with isocitrate dehydrogenase (IDH) status in grade II and III gliomas. A secondary aim was to investigate whether multishell acquisitions with advanced models such as neurite orientation dispersion and density imaging (NODDI) and diffusion kurtosis imaging offer greater diagnostic accuracy than diffusion-tensor imaging (DTI). Materials and Methods Diffusion MRI (b = 700 and 2000 sec/mm2) was performed preoperatively in 192 consecutive participants (113 male and 79 female participants; mean age, 46.18 years; age range, 14-77 years) with grade II (n = 62), grade III (n = 58), or grade IV (n = 72) gliomas. DTI, diffusion kurtosis imaging, and NODDI metrics were measured in regions with or without hyperintensity on diffusion MR images and compared among groups defined according to IDH genotype, 1p/19q codeletion status, and tumor grade by using Mann-Whitney tests. Results In grade II and III IDH wild-type gliomas, the maximum fractional anisotropy, kurtosis anisotropy, and restriction fraction were significantly higher and the minimum mean diffusivity was significantly lower than in IDH-mutant gliomas (P = .011, P = .002, P = .044, and P = .027, respectively); areas under the receiver operating characteristic curve ranged from 0.72 to 0.76. In IDH wild-type gliomas, no difference among grades II, III, and IV was found. In IDH-mutant gliomas, no difference between those with and those without 1p/19q loss was found. Conclusion Diffusion MRI metrics showed correlation with isocitrate dehydrogenase status in grade II and III gliomas. Advanced diffusion MRI models did not add diagnostic accuracy, supporting the inclusion of a single-shell diffusion-tensor imaging acquisition in brain tumor imaging protocols. Published under a CC BY 4.0 license. Online supplemental material is available for this article.


Subject(s)
Brain Neoplasms/diagnostic imaging , Brain Neoplasms/genetics , Glioma/diagnostic imaging , Glioma/genetics , Isocitrate Dehydrogenase/genetics , Magnetic Resonance Imaging/methods , Adolescent , Adult , Aged , Brain/diagnostic imaging , Diffusion Magnetic Resonance Imaging , Diffusion Tensor Imaging , Female , Genotype , Humans , Immunohistochemistry , Male , Middle Aged , Mutation/genetics , Neuroimaging/methods , Prospective Studies , Reproducibility of Results , Young Adult
13.
Chaos ; 27(9): 093901, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28964147

ABSTRACT

We propose a multiscale complexity (MSC) method assessing irregularity in assigned frequency bands and being appropriate for analyzing the short time series. It is grounded on the identification of the coefficients of an autoregressive model, on the computation of the mean position of the poles generating the components of the power spectral density in an assigned frequency band, and on the assessment of its distance from the unit circle in the complex plane. The MSC method was tested on simulations and applied to the short heart period (HP) variability series recorded during graded head-up tilt in 17 subjects (age from 21 to 54 years, median = 28 years, 7 females) and during paced breathing protocols in 19 subjects (age from 27 to 35 years, median = 31 years, 11 females) to assess the contribution of time scales typical of the cardiac autonomic control, namely in low frequency (LF, from 0.04 to 0.15 Hz) and high frequency (HF, from 0.15 to 0.5 Hz) bands to the complexity of the cardiac regulation. The proposed MSC technique was compared to a traditional model-free multiscale method grounded on information theory, i.e., multiscale entropy (MSE). The approach suggests that the reduction of HP variability complexity observed during graded head-up tilt is due to a regularization of the HP fluctuations in LF band via a possible intervention of sympathetic control and the decrement of HP variability complexity observed during slow breathing is the result of the regularization of the HP variations in both LF and HF bands, thus implying the action of physiological mechanisms working at time scales even different from that of respiration. MSE did not distinguish experimental conditions at time scales larger than 1. Over a short time series MSC allows a more insightful association between cardiac control complexity and physiological mechanisms modulating cardiac rhythm compared to a more traditional tool such as MSE.


Subject(s)
Algorithms , Heart Rate/physiology , Linear Models , Adult , Computer Simulation , Entropy , Female , Humans , Male , Middle Aged , Models, Cardiovascular , Young Adult
14.
Brain Behav Immun ; 58: 31-39, 2016 Nov.
Article in English | MEDLINE | ID: mdl-26697999

ABSTRACT

Interferon-alpha (IFN-α) is a key mediator of antiviral immune responses used to treat Hepatitis C infection. Though clinically effective, IFN-α rapidly impairs mood, motivation and cognition, effects that can appear indistinguishable from major depression and provide powerful empirical support for the inflammation theory of depression. Though inflammation has been shown to modulate activity within discrete brain regions, how it affects distributed information processing and the architecture of whole brain functional connectivity networks have not previously been investigated. Here we use a graph theoretic analysis of resting state functional magnetic resonance imaging (rfMRI) to investigate acute effects of systemic interferon-alpha (IFN-α) on whole brain functional connectivity architecture and its relationship to IFN-α-induced mood change. Twenty-two patients with Hepatitis-C infection, initiating IFN-α-based therapy were scanned at baseline and 4h after their first IFN-α dose. The whole brain network was parcellated into 110 cortical and sub-cortical nodes based on the Oxford-Harvard Atlas and effects assessed on higher-level graph metrics, including node degree, betweenness centrality, global and local efficiency. IFN-α was associated with a significant reduction in global network connectivity (node degree) (p=0.033) and efficiency (p=0.013), indicating a global reduction of information transfer among the nodes forming the whole brain network. Effects were similar for highly connected (hub) and non-hub nodes, with no effect on betweenness centrality (p>0.1). At a local level, we identified regions with reduced efficiency of information exchange and a sub-network with decreased functional connectivity after IFN-α. Changes in local and particularly global functional connectivity correlated with associated changes in mood measured on the Profile of Mood States (POMS) questionnaire. IFN-α rapidly induced a profound shift in whole brain network structure, impairing global functional connectivity and the efficiency of parallel information exchange. Correlations with multiple indices of mood change support a role for global changes in brain functional connectivity architecture in coordinated behavioral responses to IFN-α.


Subject(s)
Brain/physiology , Interferon-alpha/physiology , Adult , Brain/drug effects , Brain Mapping , Female , Humans , Interferon-alpha/administration & dosage , Magnetic Resonance Imaging , Male , Middle Aged
15.
Brain Topogr ; 29(6): 814-823, 2016 11.
Article in English | MEDLINE | ID: mdl-27509899

ABSTRACT

Diffusion tensor imaging (DTI) tractography and functional magnetic resonance imaging (fMRI) are powerful techniques to elucidate the anatomical and functional aspects of brain connectivity. However, integrating these approaches to describe the precise link between structure and function within specific brain circuits remains challenging. In this study, a novel DTI-fMRI integration method is proposed, to provide the topographical characterization and the volumetric assessment of the functional and anatomical connections within the language circuit. In a group of 21 healthy elderly subjects (mean age 68.5 ± 5.8 years), the volume of connection between the cortical activity elicited by a verbal fluency task and the cortico-cortical fiber tracts associated with this function are mapped and quantified. An application of the method to a case study in neuro-rehabilitation context is also presented. Integrating structural and functional data within the same framework, this approach provides an overall view of white and gray matter when studying specific brain circuits.


Subject(s)
Cerebral Cortex/diagnostic imaging , Gray Matter/diagnostic imaging , Language , Speech/physiology , White Matter/diagnostic imaging , Aged , Brain/diagnostic imaging , Brain/physiology , Brain Mapping , Cerebral Cortex/physiology , Diffusion Tensor Imaging/methods , Female , Functional Neuroimaging , Gray Matter/physiology , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Neural Pathways , White Matter/physiology
16.
Mult Scler ; 21(14): 1771-80, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25791368

ABSTRACT

BACKGROUND: The relationship between white matter injury and cortical atrophy development in relapsing-remitting multiple sclerosis (RRMS) remains unclear. OBJECTIVES: To investigate the associations between corticospinal tract integrity and cortical morphology measures of the primary motor cortex in RRMS patients and healthy controls. METHODS: 51 RRMS patients and 30 healthy controls underwent MRI examination for cortical reconstruction and assessment of corticospinal tract integrity. Partial correlation and multiple linear regression analyses were used to investigate the associations of focal and normal appearing white matter (NAWM) injury of the corticospinal tract with thickness and surface area measures of the primary motor cortex. Relationships between MRI measures and clinical disability as assessed by the Expanded Disability Status Scale and disease duration were also investigated. RESULTS: In patients only, decreased cortical thickness was related to increased corticospinal tract NAWM mean, axial and radial diffusivities in addition to corticospinal tract lesion volume. The final multiple linear regression model for PMC thickness retained only NAWM axial diffusivity as a significant predictor (adjusted R(2)= 0.270, p= 0.001). Clinical measures were associated with NAWM corticospinal tract integrity measures. CONCLUSIONS: Primary motor cortex thinning in RRMS is related to alterations in connected white matter and is best explained by decreased NAWM integrity.


Subject(s)
Motor Cortex/pathology , Multiple Sclerosis, Relapsing-Remitting/pathology , Pyramidal Tracts/pathology , White Matter/pathology , Adult , Atrophy/pathology , Diffusion Tensor Imaging , Female , Humans , Male , Middle Aged , Severity of Illness Index
17.
Neuroimage ; 95: 232-47, 2014 Jul 15.
Article in English | MEDLINE | ID: mdl-24657355

ABSTRACT

The identification of resting state networks (RSNs) and the quantification of their functional connectivity in resting-state fMRI (rfMRI) are seriously hindered by the presence of artefacts, many of which overlap spatially or spectrally with RSNs. Moreover, recent developments in fMRI acquisition yield data with higher spatial and temporal resolutions, but may increase artefacts both spatially and/or temporally. Hence the correct identification and removal of non-neural fluctuations is crucial, especially in accelerated acquisitions. In this paper we investigate the effectiveness of three data-driven cleaning procedures, compare standard against higher (spatial and temporal) resolution accelerated fMRI acquisitions, and investigate the combined effect of different acquisitions and different cleanup approaches. We applied single-subject independent component analysis (ICA), followed by automatic component classification with FMRIB's ICA-based X-noiseifier (FIX) to identify artefactual components. We then compared two first-level (within-subject) cleaning approaches for removing those artefacts and motion-related fluctuations from the data. The effectiveness of the cleaning procedures was assessed using time series (amplitude and spectra), network matrix and spatial map analyses. For time series and network analyses we also tested the effect of a second-level cleaning (informed by group-level analysis). Comparing these approaches, the preferable balance between noise removal and signal loss was achieved by regressing out of the data the full space of motion-related fluctuations and only the unique variance of the artefactual ICA components. Using similar analyses, we also investigated the effects of different cleaning approaches on data from different acquisition sequences. With the optimal cleaning procedures, functional connectivity results from accelerated data were statistically comparable or significantly better than the standard (unaccelerated) acquisition, and, crucially, with higher spatial and temporal resolution. Moreover, we were able to perform higher dimensionality ICA decompositions with the accelerated data, which is very valuable for detailed network analyses.


Subject(s)
Artifacts , Brain Mapping/methods , Brain/physiology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Aged , Algorithms , Female , Humans , Male , Middle Aged , Neural Pathways/physiology , Rest
18.
J Am Chem Soc ; 136(24): 8524-7, 2014 Jun 18.
Article in English | MEDLINE | ID: mdl-24884816

ABSTRACT

(19)F-MRI offers unique opportunities to image diseases and track cells and therapeutic agents in vivo. Herein we report a superfluorinated molecular probe, herein called PERFECTA, possessing excellent cellular compatibility, and whose spectral properties, relaxation times, and sensitivity are promising for in vivo (19)F-MRI applications. The molecule, which bears 36 equivalent (19)F atoms and shows a single intense resonance peak, is easily synthesized via a simple one-step reaction and is formulated in water with high stability using trivial reagents and methods.


Subject(s)
Fluorine Radioisotopes/pharmacokinetics , Hydrocarbons, Fluorinated/pharmacokinetics , Magnetic Resonance Imaging , Animals , Fluorine Radioisotopes/administration & dosage , Fluorine Radioisotopes/chemistry , Hydrocarbons, Fluorinated/administration & dosage , Hydrocarbons, Fluorinated/chemistry , Injections, Subcutaneous , Models, Molecular , Molecular Structure , Rats , Rats, Inbred Lew , Tissue Distribution
19.
J Magn Reson Imaging ; 40(1): 162-70, 2014 Jul.
Article in English | MEDLINE | ID: mdl-25050436

ABSTRACT

PURPOSE: To optimize signal-to-noise ratio (SNR) in fast spin echo (rapid acquisition with relaxation enhancement [RARE]) sequences and to improve sensitivity in ¹9F magnetic resonance imaging (MRI) on a 7T preclinical MRI system, based on a previous experimental evaluation of T1 and T2 actual relaxation times. MATERIALS AND METHODS: Relative SNR changes were theoretically calculated at given relaxation times (T1, T2) and mapped in RARE parameter space (TR, number of echoes, flip back pulse), at fixed acquisition times. T1 and T2 of KPF6 phantom samples (solution, agar mixtures, ex vivo perfused brain) were measured and experimental SNR values were compared with simulations, at optimal and suboptimal RARE parameter values. RESULTS: The optimized setting largely depended on T1, T2 times and the use of flip back pulse improved SNR up to 30% in case of low T1/T2 ratios. Relaxation times in different conditions showed negligible changes in T1 (below 14%) and more evident changes in T2 (-95% from water solution to ex vivo brain). Experimental data confirmed theoretical forecasts, within an error margin always below 4.1% at SNR losses of ~20% and below 8.8% at SNR losses of ~40%. The optimized settings permitted a detection threshold at a concentration of 0.5 mM, corresponding to 6.22 × 10¹6 fluorine atoms per voxel. CONCLUSION: Optimal settings according to measured relaxation times can significantly improve the sensitivity threshold in ¹9F MRI studies. They were provided in a wide range of (T1, T2) values and experimentally validated showing good agreement.


Subject(s)
Algorithms , Brain/anatomy & histology , Brain/metabolism , Fluorine Radioisotopes/pharmacokinetics , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Animals , Computer Simulation , Guinea Pigs , Image Enhancement/methods , In Vitro Techniques , Magnetic Resonance Imaging/instrumentation , Models, Biological , Molecular Imaging/methods , Phantoms, Imaging , Protons , Reproducibility of Results , Sensitivity and Specificity , Signal Processing, Computer-Assisted
20.
Eur Radiol Exp ; 8(1): 80, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39004645

ABSTRACT

INTRODUCTION: Breast arterial calcifications (BAC) are common incidental findings on routine mammograms, which have been suggested as a sex-specific biomarker of cardiovascular disease (CVD) risk. Previous work showed the efficacy of a pretrained convolutional network (CNN), VCG16, for automatic BAC detection. In this study, we further tested the method by a comparative analysis with other ten CNNs. MATERIAL AND METHODS: Four-view standard mammography exams from 1,493 women were included in this retrospective study and labeled as BAC or non-BAC by experts. The comparative study was conducted using eleven pretrained convolutional networks (CNNs) with varying depths from five architectures including Xception, VGG, ResNetV2, MobileNet, and DenseNet, fine-tuned for the binary BAC classification task. Performance evaluation involved area under the receiver operating characteristics curve (AUC-ROC) analysis, F1-score (harmonic mean of precision and recall), and generalized gradient-weighted class activation mapping (Grad-CAM++) for visual explanations. RESULTS: The dataset exhibited a BAC prevalence of 194/1,493 women (13.0%) and 581/5,972 images (9.7%). Among the retrained models, VGG, MobileNet, and DenseNet demonstrated the most promising results, achieving AUC-ROCs > 0.70 in both training and independent testing subsets. In terms of testing F1-score, VGG16 ranked first, higher than MobileNet (0.51) and VGG19 (0.46). Qualitative analysis showed that the Grad-CAM++ heatmaps generated by VGG16 consistently outperformed those produced by others, offering a finer-grained and discriminative localization of calcified regions within images. CONCLUSION: Deep transfer learning showed promise in automated BAC detection on mammograms, where relatively shallow networks demonstrated superior performances requiring shorter training times and reduced resources. RELEVANCE STATEMENT: Deep transfer learning is a promising approach to enhance reporting BAC on mammograms and facilitate developing efficient tools for cardiovascular risk stratification in women, leveraging large-scale mammographic screening programs. KEY POINTS: • We tested different pretrained convolutional networks (CNNs) for BAC detection on mammograms. • VGG and MobileNet demonstrated promising performances, outperforming their deeper, more complex counterparts. • Visual explanations using Grad-CAM++ highlighted VGG16's superior performance in localizing BAC.


Subject(s)
Breast Diseases , Deep Learning , Mammography , Humans , Mammography/methods , Female , Retrospective Studies , Middle Aged , Breast Diseases/diagnostic imaging , Aged , Adult , Breast/diagnostic imaging , Vascular Calcification/diagnostic imaging , Calcinosis/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods
SELECTION OF CITATIONS
SEARCH DETAIL