Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters

Database
Language
Journal subject
Publication year range
1.
J Endovasc Ther ; : 15266028231214736, 2023 Dec 14.
Article in English | MEDLINE | ID: mdl-38098263

ABSTRACT

PURPOSE: To assess the potential adjunctive role of a 3D electromagnetic (EM) navigational system for use in above-knee vessels afflicted with peripheral artery disease (PAD). Peripheral artery disease can be challenging to operators encountering significant vessel tortuosity, calcium, and stenoses, which may require prolonged procedure times and excessive use of nephrotoxic iodinated contrast when performed with conventional fluoroscopy. MATERIALS AND METHODS: Following appropriate ethical oversight, five 3D-printed bench phantoms modeling tortuous calcified PAD were created based on source CTA (computed tomography angiography) data sets from real patients. Investigational software was developed based on a commercially available aortic EM navigation platform (Intraoperative Positioning System [IOPS]; Centerline Biomedical, Inc., Cleveland, Ohio), with patient-specific structural maps of vessel lumens and calcification. Using a sensorized prototype 6 French (Fr) catheter and 0.035" guidewire, 15 interventionalists traversed each phantom using the EM platform as well as 2D simulated fluoroscopy-like image guidance and the times were recorded. Participants completed a 10-item standard system usability scale (SUS) questionnaire (score 1-5, 5=strongly agree) evaluating system usability and user satisfaction. Navigation times and SUS scores were compared with a 1-tailed statistical t test. RESULTS: Participants demonstrated a statistically significant reduction in navigation times using EM guidance, performing 0.7 minutes (42 seconds) faster on average (P < .001), corresponding to a 25% average relative reduction. Participants reported sufficiently high levels of usability satisfaction, with a mean SUS score of 4.29 (P < .001), exceeding the acceptance criterion (score ≥3.5). CONCLUSION: This preclinical phantom study highlights the future potential of Centerline Biomedical's EM navigation technology as a possible adjunct to fluoroscopy for highly precise visualization and navigation of PAD-afflicted vasculature. CLINICAL IMPACT: This preclinical proof-of-concept study highlights the feasibility of EM navigation not only for branch vessel cannulation, but also for inline navigation of peripheral vessels afflicted with calcified plaques via benchtop iliofemoral phantom simulations. The navigation platform studied addresses the need for improvements in EM technology through modelling algorithms that facilitate 3D visualization of calcified plaque in any projection in real time, in addition to sensorization of both catheter and guidewire in a compact 6Fr system.

3.
Am J Cardiol ; 219: 1-8, 2024 05 15.
Article in English | MEDLINE | ID: mdl-38458581

ABSTRACT

The 355 nm Auryon laser (AngioDynamics, Inc., Latham, New York) has been shown to be effective and safe in treating various morphology lesions in the femoropopliteal arteries. There are limited data on the Auryon laser in treating below-the-knee (BTK) arteries in patients with chronic limb-threatening ischemia. We present the 30-day efficacy and safety findings from the ongoing Auryon BTK study. Patients with chronic limb-threatening ischemia were prospectively enrolled in the Auryon BTK study between March 2022 and February 2023 in 4 US centers after obtaining written informed consent. The primary safety end point included major adverse limb events + postoperative death at 30 days, defined as a composite of all-cause death, major amputation, and target vessel revascularization. Demographic, procedural, angiographic, and outcome data were collected. A total of 60 patients (61 lesions) were treated. The mean age was 74.6 ± 10.3 years, with 65.0% men, 58.3% with diabetes, 43.3% Rutherford Becker (RB) IV, and 56.7% RB V. Of the 61 lesions, 59% had severe calcification, 31.1% were chronic total occlusions, and 90.2% were de novo disease. The baseline diameter stenosis was 80.2 ± 16.4%, after laser 57.4 ± 21.7%, and after final treatment 24.0 ± 23.1% (p <0.0050). The primary performance end point showed a procedure success rate of 37 of 68 (63.8%). Bailout stenting occurred in 1 of 61 lesions (1.6%). The RB category was 100% RB IV or higher at baseline versus 35.3% at 30 days. At 30 days, there was no target vessel revascularization and the patency was 88.9% (Peak Systolic Velocity Ratio (PSVR) ≤2.4). In conclusion, the Auryon laser is safe and relatively effective in treating BTK lesions with minimal complications.


Subject(s)
Chronic Limb-Threatening Ischemia , Humans , Male , Female , Aged , Prospective Studies , Chronic Limb-Threatening Ischemia/surgery , Treatment Outcome , Laser Therapy/methods , Peripheral Arterial Disease/surgery , Aged, 80 and over , Ischemia , Middle Aged , Popliteal Artery/surgery , Femoral Artery , Limb Salvage/methods
4.
J Soc Cardiovasc Angiogr Interv ; 2(2): 100585, 2023.
Article in English | MEDLINE | ID: mdl-39129803

ABSTRACT

Background: We report in-hospital outcomes from the multicenter, prospective, single-arm ClotTriever Outcomes (CLOUT) registry, which enrolled up to 500 patients with proximal lower extremity deep vein thrombosis (DVT) treated with percutaneous mechanical thrombectomy using the ClotTriever System (Inari Medical). Methods: The CLOUT registry enrolled all-comer patients with DVT, irrespective of symptom duration, thrombus age, prior treatment of the current DVT, or bilateral thrombus. The primary effectiveness end point was defined as complete or near complete (≥75%) reduction in Marder score. Thrombus burden was assessed by an independent core laboratory. Mortality and serious adverse events, including device-relatedness, were adjudicated by an independent medical monitor. Here, safety and outcomes are evaluated through discharge. Results: The median age was 61.9 years (IQR, 48.0-70.8), 50.5% were women, 24.9% had a history of DVT, and 23.2% had previously failed treatment of the current DVT. Nearly all procedures (99.4%) were performed in a single session with negligible procedural blood loss (median 40.0 mL; IQR, 20.0-50.0), and most patients (97.8%) required no subsequent intensive care unit monitoring. The primary effectiveness end point was achieved in 91.2% of limbs. Through discharge, 1 device-related serious adverse event (0.2%) occurred. Health status, as assessed by self-reported pain and circumferential measurements of limb edema, were significantly improved at discharge. Conclusions: Thrombectomy with the ClotTriever System is a safe and effective treatment for proximal lower extremity DVT, while also avoiding the need of intensive care. Early patient improvements are demonstrated, and follow-up is ongoing to 2 years.

SELECTION OF CITATIONS
SEARCH DETAIL