Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 52
Filter
1.
J Prosthet Dent ; 127(5): 793-800, 2022 May.
Article in English | MEDLINE | ID: mdl-33581865

ABSTRACT

STATEMENT OF PROBLEM: More translucent dental zirconias have been developed by incorporating the cubic phase and reducing the tetragonal phase content that undergoes transformation toughening, leading to reduced mechanical properties. Whether the clinically relevant mechanical property of the edge chipping toughness of the material is also reduced is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the edge chipping toughness and translucency of translucent zirconia, 3mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP), and lithium disilicate. MATERIAL AND METHODS: Two translucent zirconia products, Katana and Lava Esthetic; one 3Y-TZP, Lava Plus; and one lithium disilicate, IPS e.max Press were prepared and tested for phase composition via X-ray diffraction (XRD) (n=3), translucency via a spectrophotometer (n=20), and edge chipping via a universal testing machine with a custom-machined specimen holder and diamond indenter (n=20). The 3Y-TZP and lithium disilicate served as the optimal control materials for edge chipping and translucency, respectively. Translucency was compared with 1-way ANOVA and edge toughness with ANCOVA (α=.05). RESULTS: The XRD showed the 3Y-TZP to be almost completely tetragonal phase compared with the 2 translucent zirconia products that were predominantly cubic. Katana UTML and IPS e.max Press had a statistically similar (P>.05) translucency that was significantly (P<.05) greater than that of Lava Esthetic and Lava Plus. The edge toughness of Katana UTML was 304 N/mm, IPS e.max Press was 354 N/mm, Lava Esthetic was 394 N/mm, and Lava Plus was 717 N/mm, with significance rankings of Katana UTM

Subject(s)
Dental Materials , Esthetics, Dental , Ceramics/chemistry , Dental Materials/chemistry , Materials Testing , Surface Properties , Zirconium/chemistry
2.
J Prosthet Dent ; 122(2): 143-151, 2019 Aug.
Article in English | MEDLINE | ID: mdl-30948295

ABSTRACT

STATEMENT OF PROBLEM: Selective laser melting (SLM) technology has been introduced for printing metal dental restorations from Co-Cr base alloys or Au-Pt high noble alloys. However, information regarding the fit of restorations fabricated by using this technique is limited. PURPOSE: The purpose of this in vitro study was to determine the effect of 3 different finish line designs on the marginal and internal gaps of metal copings made from a base (Co-Cr), high noble (Au-Pd-Ag), and noble alloy (Co-Pd) by using the SLM technology. MATERIAL AND METHODS: Three Ivorine right maxillary central incisors were prepared with a chamfer, deep chamfer, or shoulder finish line. The preparations were scanned by using a TRIOS scanner, and a total of 90 dies were printed using DPR 10 Resin (30×3 finish line designs). Ten SLM copings were fabricated for each margin design and metal alloy combination for a total of 90 copings (10×3 finish line designs×3 alloys). Copings were cemented onto dies using an autopolymerizing composite-resin luting material. All coping-die assemblies were sectioned buccolingually by using a low-speed diamond saw, and images were obtained by using an inverted bright field metallurgical microscope at ×100 magnification. Marginal and internal gaps were measured at 5 locations: buccal margin, midfacial, incisal, midlingual, and lingual margin. After gap measurements, representative specimens were embedded in autopolymerizing resin and prepared for metallographic examination. A 2-way multivariate analysis of variance (MANOVA) was conducted to determine the overall significance, followed by ANOVA for each dependent variable (α=.05). RESULTS: The results indicated that alloy type and finish line had a significant influence on marginal gap of copings (P<.001). Relative to the internal gap, alloy type had a significant effect (P<.001), but the type of finish line had no statistically significant influence (P=.337). No statistically significant interactions occurred. Base alloys were printed with almost no observable porosity, whereas noble and high noble alloys exhibited hot tears and porosity. CONCLUSIONS: Thefinish line type did not influence the internal gap between copings and dies, whereas the alloy type influenced the marginal gap between copings and dies. SLM-fabricated Co-Cr copings on teeth prepared with a deep chamfer finish line demonstrated the lowest marginal gap.


Subject(s)
Crowns , Dental Marginal Adaptation , Adaptation, Psychological , Dental Prosthesis Design , Printing, Three-Dimensional
3.
J Prosthet Dent ; 120(3): 439-446, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29724557

ABSTRACT

STATEMENT OF PROBLEM: Research evaluating load-to-failure of pressed lithium disilicate glass-ceramic (LDGC) with a clinically validated test after adjustment and repair procedures is scarce. PURPOSE: The purpose of this in vitro study was to investigate the effect of the simulated chairside adjustment of the intaglio surface of monolithic pressed LDGC and procedures intended to repair damage. MATERIAL AND METHODS: A total of 423 IPS e.max Press (Ivoclar Vivadent AG) disks (15 mm diameter, 1 mm height) were used in the study. The material was tested by using an equibiaxial loading arrangement (n≥30/group) and a contact pressure test (n≥20/group). Specimens were assigned to 1 of 14 groups. One-half was assigned to the equibiaxial load test and the other half underwent contact pressure testing. Testing was performed in 2 parts, before glazing and after glazing. Before-glazing specimens were devested and entered in the test protocol, while after-glazing specimens were devested and glazed before entering the test protocol. Equibiaxial flexure test specimens were placed on a ring-on-ring apparatus and loaded until failure. Contact pressure specimens were cemented to epoxy resin blocks with a resin cement and loaded with a 50-mm diameter hemisphere until failure. Tests were performed on a universal testing machine with a crosshead speed of 0.5 mm/min. Weibull statistics and likelihood ratio contour plots determined intergroup differences (95% confidence bounds). RESULTS: Before glazing, the equibiaxial flexural strength test and the Weibull and likelihood ratio contour plots demonstrated a significantly higher failure strength for 1EC (188 MPa) than that of the damaged and/or repaired groups. Glazing following diamond-adjustment (1EGG) was the most beneficial post-damage procedure (176 MPa). Regarding the contact pressure test, the Weibull and likelihood ratio contour plots revealed no significant difference between the 1PC (98 MPa) and 1PGG (98 MPa) groups. Diamond-adjustment, without glazing (1EG and 1PG), resulted in the next-to-lowest equibiaxial flexure strength and the lowest contact pressure. After glazing, the strength of all the groups, when subjected to glazing following devesting, increased in comparison with corresponding groups in the before-glazing part of the study. CONCLUSIONS: A glazing treatment improved the mechanical properties of diamond-adjusted IPS e.max Press disks when evaluated by equibiaxial flexure and contact pressure tests.


Subject(s)
Ceramics/therapeutic use , Dental Porcelain/therapeutic use , Dental Prosthesis , Dental Restoration, Permanent/methods , Compressive Strength , Dental Marginal Adaptation , Dental Restoration Repair/methods , Flexural Strength , Humans , In Vitro Techniques
4.
J Prosthet Dent ; 116(3): 397-403, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27157600

ABSTRACT

STATEMENT OF PROBLEM: Two novel restorative materials, a polymer infiltrated ceramic network (PICN) and a resin nanoceramic (RNC), for computer-assisted design and computer-assisted manufacturing (CAD-CAM) applications have recently become commercially available. Little independent evidence regarding their mechanical properties exists to facilitate material selection. PURPOSE: The purpose of this in vitro study was to measure the edge chipping resistance and flexural strength of the PICN and RNC materials and compare them with 2 commonly used feldspathic ceramic (FC) and leucite reinforced glass-ceramic (LRGC) CAD-CAM materials that share the same clinical indications. MATERIAL AND METHODS: PICN, RNC, FC, and LRGC material specimens were obtained by sectioning commercially available CAD-CAM blocks. Edge chipping test specimens (n=20/material) were adhesively attached to a resin substrate before testing. Edge chips were produced using a 120-degree, sharp, conical diamond indenter mounted on a universal testing machine and positioned 0.1 to 0.7 mm horizontally from the specimen's edge. The chipping force was plotted against distance to the edge, and the data were fitted to linear and quadratic equations. One-way ANOVA determined intergroup differences (α=.05) in edge chipping toughness. Beam specimens (n=22/material) were tested for determining flexural strength using a 3-point bend test. Weibull statistics determined intergroup differences (α=.05). Flexural modulus and work of fracture were also calculated, and 1-way ANOVA determined intergroup differences (α=.05) RESULTS: Significant (P<.05) differences were found among the 4 CAD-CAM materials for the 4 mechanical properties. Specifically, the material rankings were edge chipping toughness: RNC>LRGC=FC>PICN; flexural strength: RNC=LRGC>PICN>FC; flexural modulus: RNCLRGC=PICN>FC. CONCLUSIONS: The RNC material demonstrated superior performance for the mechanical properties tested compared with the other 3 materials.


Subject(s)
Ceramics/therapeutic use , Dental Materials/therapeutic use , Dental Restoration, Permanent/methods , Nanostructures/therapeutic use , Computer-Aided Design , Dental Prosthesis Design , Dental Stress Analysis , Humans , Polymers/therapeutic use , Tensile Strength
5.
J Prosthet Dent ; 115(4): 489-94, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26589442

ABSTRACT

STATEMENT OF PROBLEM: The effect of toothbrushing on extrinsically stained pressable ceramic materials is unknown. PURPOSE: The purpose of this in vitro study was to investigate the effects of toothbrushing on the shade and surface roughness of extrinsically stained, pressable ceramics. MATERIAL AND METHODS: Two materials, leucite-based (IPS Empress Esthetic [EE]; Ivoclar Vivadent AG) and lithium disilicate-based ceramic (IPS e.max Press [EP]; Ivoclar Vivadent AG), were studied. For each material, 24 disk-shaped specimens, 10 mm (diameter)×3 mm (height) were fabricated. Three different methods (n=8) of applying extrinsic stains were performed on each material: glazed only (G, control group); stained then glazed (SG); and stained and glazed together (T). The specimens were brushed with a multistation brushing machine under a load of 1.96 N at a rate of 90 strokes per minute with a soft and straight toothbrush (Oral-B #35) and a 1:1 toothpaste and distilled water slurry. Shade and roughness were measured at baseline and at 72, 144, 216, and 288 hours, which is equivalent to 3, 6, 9, and 12 years of simulated toothbrushing for 2 minutes twice a day. A repeated measures ANOVA with staining technique as a fixed factor was used to evaluate shade and roughness (α=.05). RESULTS: For EE groups, no significant change was found after 12 years of simulated toothbrushing regarding shade and surface roughness, irrespective of staining techniques (P>.05). However, EP groups demonstrated a significant shade change and an increase in surface roughness after 12 years of simulated toothbrushing. Shade change was found to depend on the method of applying stain. For the EP-SG technique, a significant shade change was observed only at the 9- to 12-year interval (P=.047). However, the EP-T technique demonstrated a significant difference in shade between baseline and 3 years (P=.005) and in the 6- to 9-year interval (P=.005). Surface roughness was only significantly affected at baseline and 3 years for the EP-T group (P=.005). CONCLUSIONS: For the shade and surface roughness of the EE groups, no statistically significant difference was found after 12 years of toothbrushing, irrespective of the staining technique. The shade and surface roughness of the EP groups were significantly statistically affected by toothbrushing time; only shade changes were found to depend on technique.


Subject(s)
Ceramics/chemistry , Surface Properties , Toothbrushing , Dental Porcelain/chemistry , Dental Stress Analysis , Humans , Materials Testing , Toothpastes
6.
J Adhes Dent ; 17(1): 67-75, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25646167

ABSTRACT

PURPOSE: To investigate polyalkenoate reaction rates in conventional glass-ionomer cement (GIC) and resin-modified glass ionomer (RMGI) restorative materials using infrared spectroscopy. MATERIALS AND METHODS: Nine conventional GIC and six RMGI restorative materials were prepared according to manufacturer's directions and placed on a FTIR (Fourier transform infrared spectroscopy) diamond ATR (attenuated total reflectance) surface. FTIR spectra (700 to 1800 cm-1) were obtained each minute for 3 h. VLC specimens were light polymerized after 1 min; at 5 min, all samples were covered with gauze saturated with deionized water. Polyalkenoate reaction was determined by measuring area growth (Å/cm-1) between 1375 and 1500 cm-1. Mean peak areas were determined at 5, 15, 30, 90, and 180 min and compared using ANOVA (p = 0.05) RESULTS: For all RMGI materials, VLC polymerization inhibited the polyalkenoate reaction rate. Compared to conventional GIC, RMGI materials demonstrated less polyalkenoate reaction. Compared to dark curing, RMGI light polymerization significantly inhibited the polyalkenoate reaction rate. CONCLUSIONS: The addition of resin components to glass-ionomer products significantly retards and impedes the polyalkenoate reaction. The polyalkenoate reaction rate of RMGI products was significantly lower than that of self-curing GIC restorative materials. Furthermore, light activation of RMGI products further retards the polyalkenoate rate. When clinicians require the therapeutic benefit of a polyalkenoate product, perhaps a conventional GIC restorative product should be the first material of choice.


Subject(s)
Glass Ionomer Cements/chemistry , Aluminum Silicates/chemistry , Cermet Cements/chemistry , Chemical Phenomena , Composite Resins/chemistry , Darkness , Humans , Kinetics , Light-Curing of Dental Adhesives , Maleates/chemistry , Polymerization , Resin Cements/chemistry , Resins, Synthetic/chemistry , Spectroscopy, Fourier Transform Infrared , Time Factors , Water/chemistry
7.
J Prosthet Dent ; 113(5): 398-404, 2015 May.
Article in English | MEDLINE | ID: mdl-25794915

ABSTRACT

STATEMENT OF PROBLEM: The inability to control die spacer thickness has been reported. However, little information is available on the congruency between the computer-aided design parameters for die spacer thickness and the actual printout. PURPOSE: The purpose of this study was to evaluate the accuracy and precision of the die spacer thickness achieved by combining computer-aided design and 3-dimensional printing technology. MATERIAL AND METHODS: An ivorine maxillary central incisor was prepared for a ceramic crown. The prepared tooth was duplicated by using polyvinyl siloxane duplicating silicone, and 80 die-stone models were produced from Type IV dental stone. The dies were randomly divided into 5 groups with assigned die spacer thicknesses of 25 µm, 45 µm, 65 µm, 85 µm, and 105 µm (n=16). The printed resin copings, obtained from a printer (ProJet DP 3000; 3D Systems), were cemented onto their respective die-stone models with self-adhesive resin cement and stored at room temperature until sectioning into halves in a buccolingual direction. The internal gap was measured at 5 defined locations per side of the sectioned die. Images of the printed resin coping/die-stone model internal gap dimensions were obtained with an inverted bright field metallurgical microscope at ×100 magnification. The acquired digital image was calibrated, and measurements were made using image analysis software. Mixed models (α=.05) were used to evaluate accuracy. A false discovery rate at 5% was used to adjust for multiple testing. Coefficient of variation was used to determine the precision for each group and was evaluated statistically with the Wald test (α=.05). RESULTS: The accuracy, expressed in terms of the mean differences between the prescribed die spacer thickness and the measured internal gap (standard deviation), was 50 µm (11) for the 25 µm group simulated die spacer thickness, 30 µm (10) for the 45 µm group, 15 µm (14) for the 65 µm group, 3 µm (23) for the 85 µm group, and -10 µm (32) for the 105 µm group. The precision mean of the measurements, expressed as a coefficient of variation, ranged between 14% and 33% for the 5 groups. CONCLUSIONS: For the accuracy evaluation, statistically significant differences were found for all the groups, except the group of 85 µm. For the precision assessment, the coefficient of variation was above 10% for all groups, showing the printer's inability to reproduce the uniform internal gap within the same group.


Subject(s)
Computer-Aided Design , Crowns , Dental Marginal Adaptation , Dental Prosthesis Design/instrumentation , Printing, Three-Dimensional , Computer-Aided Design/standards , Crowns/standards , Humans , Image Processing, Computer-Assisted/methods , Materials Testing , Models, Dental , Printing, Three-Dimensional/standards , Random Allocation , Resin Cements/chemistry , Surface Properties , Tooth Preparation, Prosthodontic/instrumentation
8.
Eur J Orthod ; 37(1): 43-8, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25086028

ABSTRACT

BACKGROUND/OBJECTIVES: Because polymer-based materials typically exhibit viscoelastic properties, the objective was to determine if commercially available, aesthetic, fibre-reinforced composite archwires maintain continuous forces without undergoing force decay when deflected continuously. MATERIALS/METHODS: Quasi force decay was evaluated by comparing three-point bending profiles of nickel-titanium (NiTi) and fibre-reinforced composite archwires (BioMers) prior to and after 30 days of continuous deflection of either 1 or 2mm. Paired t-tests or non-parametric signed rank tests were used to statistically compare pre- and post-deflection bending forces. A control group consisting of wires not subject to the 30-day constant deflection was tested to check whether the initial testing altered the second three-point bend test. RESULTS: Significant (P < 0.01) differences in the pre- and post-deflection deactivation force delivery were most evident in the composite 2mm deflection group and all of the NiTi groups. The composite 2mm deflection group failed to deliver consistent forces as the majority of the wires experienced crazing during the 30-day deflection period. The decrease in force delivery in the NiTi groups may be attributed to the small standard deviations. CONCLUSIONS: The composite 1mm deflection group demonstrated that fibre-reinforced composite archwires are able to deliver a consistent force after 30 days of deflection. However, the clinical applicability of these fibre-reinforced composite archwires may be limited as they are unable to sustain deflections of 2mm without experiencing crazing and loss of force delivery. LIMITATIONS: Clinical efficacy of the aesthetic, fibre-reinforced composite orthodontic archwires remains to be observed.


Subject(s)
Esthetics, Dental , Orthodontic Wires , Composite Resins/chemistry , Dental Alloys/chemistry , Dental Stress Analysis/methods , Elasticity , Equipment Design , Humans , Materials Testing/methods , Mechanical Phenomena , Nickel , Titanium
9.
J Contemp Dent Pract ; 16(5): 347-52, 2015 05 01.
Article in English | MEDLINE | ID: mdl-26162252

ABSTRACT

AIM: This study evaluated the effects of ceramic veneer thicknesses on the polymerization of two different resin cements. MATERIALS AND METHODS: A total of 80 ceramic veneer disks were fabricated by using a pressable ceramic material (e.max Press; Ivoclar Vivadent) from a Low Translucency (LT) ingot (A1 shade). These disks were divided into light-cured (LC; NX3 Nexus LC; Kerr) and dual-cured (DC; NX3 Nexus DC; Kerr) and each group was further divided into four subgroups, based on ceramic disk thickness (0.3, 0.6, 0.9, and 1.2 mm). The values of Vickers microhardness (MH) and degree of conversion (DOC) were obtained for each specimen after a 24-hour storage period. Association between ceramic thickness, resin cement type, and light intensity readings (mW/cm(2)) with respect to microhardness and degree of conversion was statistically evaluated by using analysis of variance (ANOVA). RESULTS: For the DOC values, there was no significant difference observed among the LC resin cement subgroups, except in the 1.2 mm subgroup; only the DOC value (14.0 ± 7.4%) of 1.2 mm DC resin cement had significantly difference from that value (28.9 ± 7.5%) of 1.2 mm LC resin cement (p < 0.05). For the MH values between LC and DC resin cement groups, there was statistically significant difference (p < 0.05); overall, the MH values of LC resin cement groups demonstrated higher values than DC resin cement groups. On the other hands, among the DC resin cement subgroups, the MH values of 1.2 mm DC subgroup was significantly lower than the 0.3 mm and 0.6 mm subgroups (p < 0.05). However, among the LC subgroups, there was no statistically significant difference among them (p > 0.05). CONCLUSION: The degree of conversion and hardness of the resin cement was unaffected with veneering thicknesses between 0.3 and 0.9 mm. However, the DC resin cement group resulted in a significantly lower DOC and MH values for the 1.2 mm subgroup. CLINICAL SIGNIFICANCE: While clinically adequate polymerization of LC resin cement can be achieved with a maximum 1.2 mm of porcelain veneer restoration, the increase of curing time or light intensity is clinically needed for DC resin cements at the thickness of more than 0.9 mm.


Subject(s)
Dental Porcelain/chemistry , Dental Veneers , Light-Curing of Dental Adhesives/methods , Resin Cements/chemistry , Self-Curing of Dental Resins/methods , Curing Lights, Dental/classification , Hardness , Humans , Materials Testing , Polymerization , Radiation Dosage , Spectroscopy, Fourier Transform Infrared , Surface Properties , Temperature , Time Factors
10.
Eur J Orthod ; 36(3): 290-6, 2014 Jun.
Article in English | MEDLINE | ID: mdl-23873791

ABSTRACT

BACKGROUND/OBJECTIVES: The purpose of this study was to compare the mechanical, structural, and aesthetic properties of two types of aesthetic coated nickel-titanium (NiTi) wires compared with comparable regular NiTi wires in the as-received state and after clinical use. MATERIALS/METHODS: Sixty one subjects were randomly assigned to four groups (N = 61), two groups of coated wires and two groups of comparable, non-coated controls (n = 15/group). The period in the mouth ranged from 4 to 12 weeks after insertion. In total, 121 wires (61 retrieved and 60 as-received) were used in the study. The percentages of coating retention and loss were extrapolated from scans. A brief survey of five questions with three choices was given to all patients. Differential scanning calorimetry (DSC) and three-point bending tests were done on as-received and used wires. RESULTS: The surface characterization by the percentage of resin remaining indicated that most wires in both test groups lost a significant amount of coating. A patient survey indicated that this was a noticeable feature for patients. DSC analysis of the wires indicated that the metallurgical properties of the coated wires were not similar to the uncoated wires in the as-received condition. Three-point bending results indicate a wide variation in test results with large standard deviations among all the groups. LIMITATIONS: The extent of coating loss requires investigating, as do the biological properties of the detached coating. CONCLUSIONS: Both wires lost a significant amount of aesthetic coating after varying periods in the mouth. The metallurgical testing of these findings may indicate that these wires perform differently in the mouth.


Subject(s)
Esthetics, Dental , Nickel , Orthodontic Wires , Titanium , Adolescent , Calorimetry, Differential Scanning/methods , Child , Coated Materials, Biocompatible/chemistry , Dental Alloys/chemistry , Elasticity , Equipment Failure , Female , Humans , Male , Materials Testing/methods , Orthodontic Appliance Design , Pliability , Young Adult
11.
J Endod ; 50(8): 1143-1150, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38762142

ABSTRACT

INTRODUCTION: Nickel-titanium rotary endodontic files have been commercially available for decades, but more recent innovations have introduced heat-treated and surface-treated files. This study investigated the corrosion properties of various nickel-titanium files in normal saline and sodium hypochlorite (NaOCl). METHODS: Ten different file brands of size 40 with a 0.04 taper were subjected to electrochemical testing in 0.9% NaCl (saline) and 5.25% NaOCl at room temperature. The Open Circuit Potential (OCP) was observed for 1 hour followed by a cyclic polarization test from -300 to 700 mV and back to -300 mV (vs OCP). Nonparametric ANOVA and a pairwise comparison (P < .05) were used for statistical analysis of the OCP at 1 hour and the corrosion current (Icorr) obtained via the cyclic polarization test. RESULTS: Significant differences (P < .05) were found between files with respect to OCP and Icorr in both solutions. Nine files exhibited significantly greater (P < .05) Icorrs in NaOCl than in saline. Conversely, pitting corrosion was observed in the saline solution but not NaOCl. Weak and/or moderate correlations existed between OCP and Icorr measures in the 2 solutions. CONCLUSION: Significant differences in electrochemical properties were observed among the 10 brands of files. Overall, there was not a clear trend between conventional, heat-treated, or surface-treated files among OCP or Icorr in either solution.


Subject(s)
Nickel , Root Canal Preparation , Titanium , Nickel/chemistry , Titanium/chemistry , Corrosion , Root Canal Preparation/instrumentation , Sodium Hypochlorite/chemistry , Dental Instruments , Materials Testing , Electrochemistry , Electrochemical Techniques , Dental Alloys/chemistry , Surface Properties
12.
Eur J Orthod ; 35(4): 500-6, 2013 Aug.
Article in English | MEDLINE | ID: mdl-22573910

ABSTRACT

Corrosion of orthodontic miniscrews or temporary anchorage devices (TADs) has been proposed as a contributor to inflammation, which in turn is a factor in the clinical success of miniscrews. The purpose of this study was to measure the electrochemical properties of orthodontic miniscrews in artificial saliva with and without fluoride. The corrosion properties of three miniscrew products (VectorTAS, Ormco Corp.; Unitek TAD, 3M Unitek; and Through-Hole Screw, American Orthodontics) were tested in an artificial saliva (Fusayama-Meyer) with (1500 ppm) or without fluoride (n = 10/product/solution). Open circuit potential (OCP), polarization resistance (R p), and corrosion current (I corr) were measured and statistically analysed with the Friedman/Tukey least significant difference tests. No significant differences (P > 0.05) between miniscrews with regard to OCP, R p, and I corr were found except that the American Orthodontics miniscrews had a significantly (P < 0.05) more noble OCP compared to the others. Incorporation of 1500 ppm fluoride in the artificial saliva significantly (P < 0.001) lowered the OCP, reduced the polarization resistance, and increased the corrosion current of each miniscrew product. Few differences existed in the electrochemical properties of miniscrews from the three different manufacturers; however, exposure to fluoride was detrimental to the corrosion properties of all miniscrews.


Subject(s)
Bone Screws , Orthodontic Anchorage Procedures/instrumentation , Corrosion , Fluorides/chemistry , Humans , Saliva, Artificial/chemistry
13.
Eur J Orthod ; 34(2): 257-61, 2012 Apr.
Article in English | MEDLINE | ID: mdl-21300729

ABSTRACT

The purpose of this study was to compare the shear bond strengths (SBSs) of orthodontic brackets bonded with self-etching primer (SEP) using different enamel surface preparations. A two-by-two factorial study design was used. Sixty human premolars were harvested, cleaned, and randomly assigned to four groups (n = 15 per group). Teeth were bathed in saliva for 48 hours to form a pellicle. Treatments were assigned as follows: group 1 was pumiced for 10 seconds and pre-etched for 5 seconds with 37 per cent phosphoric acid before bonding with SEP (Transbond Plus). Group 2 was pumiced for 10 seconds before bonding. Group 3 was pre-etched for 5 seconds before bonding. Group 4 had no mechanical or chemical preparation before bonding. All teeth were stored in distilled water for 24 hours at 37°C before debonding. The SBS values and adhesive remnant index (ARI) score were recorded. The SBS values (± 1 SD) for groups 1-4 were 22.9 ± 6.6, 16.1 ± 7.3, 36.2 ± 8.2, and 13.1 ± 10.1 MPa, respectively. Two-way analysis of variance and subsequent contrasts showed statistically significant differences among treatment groups. ARI scores indicated the majority of adhesive remained on the bracket for all four groups. Pre-etching the bonding surface for 5 seconds with 37 per cent phosphoric acid, instead of pumicing, when using SEPs to bond orthodontic brackets, resulted in greater SBSs.


Subject(s)
Acid Etching, Dental/methods , Dental Bonding , Dental Prophylaxis/methods , Resin Cements/chemistry , Silicates/chemistry , Adhesiveness , Dental Alloys/chemistry , Dental Enamel/ultrastructure , Dental Pellicle/ultrastructure , Dental Stress Analysis/instrumentation , Elastic Modulus , Humans , Light-Curing of Dental Adhesives , Materials Testing , Orthodontic Appliance Design , Orthodontic Brackets , Phosphoric Acids/chemistry , Shear Strength , Stainless Steel/chemistry , Stress, Mechanical , Surface Properties , Temperature , Time Factors , Water/chemistry
14.
J Prosthodont ; 21(2): 88-93, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380645

ABSTRACT

PURPOSE: An entirely new subclass of casting alloy composition whereby palladium (∼approximately 25 wt%) is added to traditional base metal alloys such as CoCr and NiCr was recently introduced to the market. The purpose of this study was to evaluate the elemental release of new CoPdCr and NiPdCr alloys and compare them to traditional CoCr and NiCr alloys. MATERIALS AND METHODS: Five casting alloys were investigated: CoPdCr-A (NobleCrown NF, The Argen Corporation), CoPdCr-I (Callisto CP+, Ivoclar Vivadent), NiPdCr (NobleCrown, Argen), CoCr (Argeloy N.P. Special, Argen), and NiCr (Argeloy N.P. Star, Argen). Rectangular specimens (n = 6/alloy) were prepared and immersed in a lactic acid/NaCl solution at 37°C for 7 days according to ISO 10271. Solutions were analyzed with ICP-AES to determine elemental release. The concentrations of major ions (cobalt, nickel, palladium, chromium, and molybdenum) were compared using a generalized linear model (p < 0.05). Representative specimens were examined with optical microscopy before and after immersion. RESULTS: The CoPdCr alloys released a significantly greater amount of respective ions (Co, Cr, Mo, and total ions) compared to the traditional CoCr alloy. No significant differences in elemental release were noted between NiPdCr and NiCr. Optical microscopic examination showed abundant areas of corrosion in the palladium-containing CoCr alloys after immersion, whereas little difference was observed for the other alloys. CONCLUSIONS: Corrosion resistance measured via elemental release was compromised when CoCr was alloyed with palladium, but this effect was not observed with NiCr.


Subject(s)
Chromium Alloys/chemistry , Alloys/chemistry , Chromium/analysis , Cobalt/analysis , Cobalt/chemistry , Corrosion , Dental Casting Technique , Hydrogen-Ion Concentration , Linear Models , Molybdenum/analysis , Nickel/analysis , Nickel/chemistry , Palladium/analysis , Palladium/chemistry , Solutions , Spectrophotometry, Atomic
15.
Materials (Basel) ; 15(3)2022 Jan 21.
Article in English | MEDLINE | ID: mdl-35160751

ABSTRACT

The complex role of water in glass ionomer cement (polyalkenoate) dental restorative materials has been studied, but much of the present understanding concerning water balance within these materials is based on very early studies and short-term experiments. This study evaluated the nature of the water species of six conventional and four resin modified glass ionomer restorative materials over 3 years using thermogravimetric analysis techniques. Materials were prepared, placed in crucibles, and stored in physiologic phosphate buffered saline and evaluated at 24 h, 1 week, and then at 1, 3, 6, 9, 12, 18, 24, 30 and 36 months. All materials demonstrated a significant increase in unbound water percentage content but except for the resin modified materials, the enthalpy required to remove the unbound water species did not significantly change over 36 months. Also, bound water content percentage and removal enthalpy was established at 24 h, as no significant increase was noted in both bound water content and removal enthalpy over the course of this evaluation. This study suggests that unbound water species may increase with time and is loosely held except for the resin modified materials. Protective coatings placement and re-evaluation are prudent to prevent unbound water loss.

16.
J Prosthet Dent ; 105(1): 35-43, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21194586

ABSTRACT

STATEMENT OF PROBLEM: A new subclass of casting alloy composition involving the addition of palladium (25 wt%) to traditional base metal alloys, thereby raising their classification to that of a noble alloy, has been recently introduced. Little is known about this class of casting alloy, particularly its corrosion properties, which influence its biocompatibility and esthetics. PURPOSE: The purpose of this study was to evaluate the corrosion properties of 2 new CoPdCr and one new NiPdCr alloy and compare them to traditional CoCr and NiCr alloys. MATERIAL AND METHODS: The casting alloys investigated were: CoPdCr-A (NobleCrown NF), CoPdCr-I (Callisto CP+), NiPdCr (Noble Crown), CoCr (Argeloy N.P. Special), and NiCr (Argeloy N.P. Star). Cylindrical (4.8-mm diameter) as-cast and oxidized specimens were assessed electrochemically in phosphate-buffered saline at 24°C (n=8 and n=6, respectively). The open circuit potential (OCP) was monitored for 20 hours, followed by linear polarization and cyclic polarization tests. A generalized linear mixed model was used to determine whether differences existed between alloys and to examine the effect of oxidation (α=.05). Representative alloy surfaces were scanned and examined with light microscopy. RESULTS: The palladium-containing alloys possessed a significantly greater OCP (P<.001); however, their polarization resistance was less and the corrosion current density was significantly greater (P<.05) than their traditional CoCr and NiCr alloy counterparts. Additionally, a greater incidence of pitting was observed in the palladium-containing alloys. Some differences were noted within alloys between the as-cast and oxidized conditions, but a major trend was not observed. CONCLUSIONS: Overall, the inclusion of palladium in CoCr and NiCr alloys had deleterious effects on electrochemical corrosion properties.


Subject(s)
Chromium Alloys/chemistry , Cobalt/chemistry , Nickel/chemistry , Palladium/chemistry , Biocompatible Materials/chemistry , Corrosion , Dental Casting Investment/chemistry , Electric Impedance , Electrochemical Techniques , Hot Temperature , Humans , Image Processing, Computer-Assisted , Materials Testing , Metal Ceramic Alloys/chemistry , Oxidation-Reduction , Surface Properties , Time Factors , Vacuum
17.
J Prosthet Dent ; 106(1): 48-56, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21723993

ABSTRACT

STATEMENT OF PROBLEM: Current demographic information on the number and types of removable partial dentures is lacking in the prosthodontic literature. PURPOSE: This study was designed to investigate patterns of tooth loss in patients receiving removable partial dentures (RPDs) in eastern Wisconsin. MATERIAL AND METHODS: Digital images (1502) of casts at 5 dental laboratories in eastern Wisconsin were collected. Any prescription requesting fabrication of a removable partial denture was photographed twice. The first photograph was made immediately upon arrival at the laboratory, while the second photograph was made immediately before being returned to the prescribing dentist for the first time. A calibrated investigator analyzed all the photographs for Kennedy Classification, type of RPD, major connector, and other details. Data were analyzed with descriptive statistics. Fisher's exact test was used to confirm repeatability. RESULTS: Kennedy Class I was the most common RPD with a frequency of 38.4%. More than 40% of prescriptions had no design input from the dentist. One in 3 RPDs used acrylic resin or flexible frameworks. One in 5 RPDs had no rests. The horseshoe major connector was the most common maxillary major connector, while the lingual plate was the most common in the mandible. CONCLUSIONS: RPDs remain a common prosthodontic treatment in this region. Non-metal RPD frameworks are a common treatment type and rarely include rests. These data indicate a changing partially edentulous patient population and a variable commitment to standard levels of prosthodontic care.


Subject(s)
Dental Clasps/classification , Denture Design/classification , Denture, Partial, Removable/classification , Jaw, Edentulous, Partially/classification , Cohort Studies , Dental Clasps/standards , Dental Clasps/statistics & numerical data , Denture Design/standards , Denture, Partial, Removable/standards , Denture, Partial, Removable/statistics & numerical data , Humans , Interprofessional Relations , Jaw, Edentulous, Partially/rehabilitation , Laboratories, Dental , Mandible , Maxilla , Models, Dental , Quality Control
18.
Am J Orthod Dentofacial Orthop ; 140(1): 25-31, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21724083

ABSTRACT

INTRODUCTION: The purpose of this study was to compare galvanic currents generated by different combinations of commonly used brackets and archwires. METHODS: As-received stainless steel, nickel-titanium, and beta-titanium wires were coupled to stainless steel and titanium brackets in an artificial saliva medium. The galvanic current and amount of charge transferred for each pair were monitored with a zero resistance ammeter for 10 hours. RESULTS: Two-way analysis of variance (ANOVA) showed a significant difference in charge and galvanic currents when factored for type of bracket (P <0.001), but no significant difference between them when factored by type of wire (P >0.05). Specifically, a brazed stainless steel bracket was significantly greater in charge transferred and 10-hour galvanic current than metal injection molded stainless steel and titanium brackets (P <0.001), which were not different from each other (P >0.05). CONCLUSIONS: The method of bracket manufacturing might be of equal or more relevance to galvanic corrosion susceptibility than bracket composition.


Subject(s)
Dental Alloys , Electrogalvanism, Intraoral , Orthodontic Appliance Design , Orthodontic Brackets , Orthodontic Wires , Analysis of Variance , Corrosion , Electric Conductivity , Materials Testing , Nickel , Potentiometry , Saliva, Artificial , Stainless Steel , Statistics, Nonparametric , Titanium
19.
Angle Orthod ; 91(3): 349-355, 2021 05 01.
Article in English | MEDLINE | ID: mdl-33492364

ABSTRACT

OBJECTIVES: To evaluate the cytotoxicity effects of two different solder materials used for orthodontic appliances on human periodontal ligament fibroblast (HPLF) cells, and to determine whether the mechanism of toxicity may involve oxidative stress and apoptosis. MATERIALS AND METHODS: The silver solder samples (Leone and Summit) were soldered to orthodontic stainless steel bands and exposed to HPLF cells via cell culture inserts for 48 hours. Cytotoxicity effect of the soldered materials on HPLF cells was measured via tetrazolium salt 3-(4,5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide (MTT) colorimetric assay (n = 10/sample) and morphological observation. In addition, the mechanism of cytotoxicity of the most toxic silver solder was investigated using both a caspase inhibitor Z-VAL-Ala-Asp-flu-oromethylketone (ZVAD-fmk) and the free radical scavenger Trolox (n = 8/sample). Statistical analysis was performed using one-way analysis of variance with a Bonferroni test. P < .05 was considered statistically significant. RESULTS: Compared to the control (no treatment, cells only), both silver solders were cytotoxic (P < .001). The bands alone were significantly cytotoxic compared to the control. There was a significant difference in cytotoxicity between the stainless steel bands alone and the Summit silver solder (P < .001), but not the Leone silver solder. The Summit silver solder was more cytotoxic than the Leone silver solder (P < .05). MTT results were supported by the microscopic morphological changes of the HPLF cells. Neither ZVAD-fmk nor Trolox provided significant protection. CONCLUSIONS: The two silver solder materials demonstrated different levels of cytotoxicity, and neither oxidative stress nor apoptosis is involved in the mechanism of cytotoxicity.


Subject(s)
Antioxidants , Silver , Antioxidants/pharmacology , Apoptosis , Fibroblasts , Humans , Indicators and Reagents , Periodontal Ligament , Silver/toxicity
20.
Turk J Orthod ; 33(3): 165-170, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32974062

ABSTRACT

OBJECTIVE: Sealants are used in orthodontics to help prevent demineralization during treatment. This study aimed to determine if there is a difference in the shear bond strength (SBS) between 2 different resin sealants bonded to teeth. METHODS: Extracted human premolars (n=20/group) were randomly divided and prepared by acid etching, followed by application of primer or sealant. Group 1, the control group, used Transbond XT Primer (3M Unitek). Groups 2 and 3 were prepared with the sealants L.E.D. Pro Seal (Reliance Orthodontic Products) and Opal Seal (Opal Orthodontics) as the respective primers. Transbond XT Adhesive was applied to a stainless steel bracket and bonded to each tooth. Each group was stored in distilled water at 37°C for 48 hours before. SBS was measured using a universal testing machine, and the adhesive remnant index (ARI) was scored. RESULTS: The SBS (MPa) of the groups was as follows: Group 1 (Transbond): 20.1±6.0; Group 2 (Pro Seal): 16.5±4.8; and Group 3 (Opal Seal): 15.7±3.9. The SBS of Transbond XT Primer was significantly greater than that of Opal Seal (p<0.05/analysis of variance-Tukey), while Pro Seal and Opal Seal sealants were not significantly different from each other (p<0.05). The Opal Seal group had significantly greater ARI scores, indicating that more adhesive remained on the teeth after debonding. CONCLUSION: Opal Seal and Pro Seal sealants have similar SBS but generally exhibit lower bond strengths than an adhesive primer.

SELECTION OF CITATIONS
SEARCH DETAIL