Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 81
Filter
Add more filters

Publication year range
1.
Radiologe ; 60(8): 737-746, 2020 Aug.
Article in German | MEDLINE | ID: mdl-32350555

ABSTRACT

PURPOSE: Interdisciplinary tumor boards are periodical conferences, where optimal individual therapy plans are developed among medical experts with different specializations. The presence of a board-certified radiologist is medically indispensable in almost all relevant boards. In order to systematically evaluate the current workload for radiologists caused by these boards, we evaluated the current situation within German radiology to obtain numbers for future personnel planning. MATERIALS AND METHODS: We performed an online survey. We invited all 33 German university chairmen and 50 randomly selected head physicians of radiology at level 3 hospitals to participate. RESULTS: We had a participation rate of 79% (26/33) at university hospitals and 56% (28/50) at of level 3 non-university hospitals. The average total number of tumor boards was 3.3/day or 16.7/week at university hospitals and 2.6/day or 13/week at level 3 non-university hospitals. We calculated an average time considering preparation and execution as well as the average number of boards of 33.1 h/week for university hospitals and 18.2 h/week for level 3 hospitals. This results in a 78.8% workload for a board-certified radiologist at a university hospital (regular weekly work time 42 h) and 45.5% work load for level 3 hospitals (regular weekly work time 40 h). CONCLUSION: "Speaking radiology" as in interdisciplinary tumor boards represents a fundamental matter of course in radiology. The active participation in boards accomplished by radiologists improves evidence-based patient care. However, given the prevailing scarcity of resources in medicine, the data collected here regarding personnel costs for clinical radiology for participation in tumor boards must be taken into account in future discussions on personnel compensation.


Subject(s)
Neoplasms/diagnostic imaging , Radiology/organization & administration , Germany , Governing Board/organization & administration , Humans , Internet , Surveys and Questionnaires
2.
Radiologe ; 58(1): 56-59, 2018 Jan.
Article in German | MEDLINE | ID: mdl-29222586

ABSTRACT

BACKGROUND: Sclerosing mesenteritis (SM) and mesenteric panniculitis are rare processes of the mesentery which pose a major clinical and imaging challenge. This review article attempts to introduce a systematic nomenclature to address typical symptoms, imaging and major differential diagnoses. RESULTS: SM with its subtypes-mesenteric lipodystrophy, panniculitis and retractile mesenteritis-is a chronic process with a very diverse and heterogeneous clinical appearance. The typical radiological characteristics ("misty mesentery", increased lymph nodes, pseudocapsule and "fat halo") are also not very specific. A link between SM and malignant diseases is not proven, but there is controversial discussion. Therefore, if there are doubts about the diagnosis, further examinations and a biopsy are desired. CONCLUSION: When diagnosing SM, "red flags", i. e. characteristics that are atypical for SM in imaging, should be considered. In case of ambiguous imaging, differential diagnostics should also consider malignant diseases and exclude them.


Subject(s)
Panniculitis, Peritoneal , Biopsy , Diagnosis, Differential , Humans , Mesentery , Radiography
3.
Radiologe ; 54(5): 436-48, 2014 May.
Article in German | MEDLINE | ID: mdl-24824378

ABSTRACT

The increasing availability of computed tomography has meant that the number of incidentally detected solitary pulmonary nodules (SPN) has greatly increased in recent years. A reasonable management of these SPN is necessary in order to firstly be able to detect malignant lesions early on and secondly to avoid upsetting the patient unnecessarily or carrying out further stressful diagnostic procedures. This review article shows how the dignity of SPNs can be estimated and based on this how the management can be accomplished taking established guidelines into consideration.


Subject(s)
Lung Neoplasms/diagnostic imaging , Lung Neoplasms/therapy , Practice Guidelines as Topic , Radiography, Thoracic/standards , Solitary Pulmonary Nodule/diagnostic imaging , Solitary Pulmonary Nodule/therapy , Tomography, X-Ray Computed/standards , Early Detection of Cancer/standards , Humans , Prognosis , Radiographic Image Enhancement/standards , Treatment Outcome
4.
Hum Mol Genet ; 18(11): 1909-23, 2009 Jun 01.
Article in English | MEDLINE | ID: mdl-19279158

ABSTRACT

Mutations in CHD7, a chromodomain gene, are present in a majority of individuals with CHARGE syndrome, a multiple anomaly disorder characterized by ocular Coloboma, Heart defects, Atresia of the choanae, Retarded growth and development, Genital hypoplasia and Ear anomalies. The clinical features of CHARGE syndrome are highly variable and incompletely penetrant. Olfactory dysfunction is a common feature in CHARGE syndrome and has been potentially linked to primary olfactory bulb defects, but no data confirming this mechanistic link have been reported. On the basis of these observations, we hypothesized that loss of Chd7 disrupts mammalian olfactory tissue development and function. We found severe defects in olfaction in individuals with CHD7 mutations and CHARGE, and loss of odor evoked electro-olfactogram responses in Chd7 deficient mice, suggesting reduced olfaction is due to a dysfunctional olfactory epithelium. Chd7 expression was high in basal olfactory epithelial neural stem cells and down-regulated in mature olfactory sensory neurons. We observed smaller olfactory bulbs, reduced olfactory sensory neurons, and disorganized epithelial ultrastructure in Chd7 mutant mice, despite apparently normal functional cilia and sustentacular cells. Significant reductions in the proliferation of neural stem cells and regeneration of olfactory sensory neurons in the mature Chd7(Gt/+) olfactory epithelium indicate critical roles for Chd7 in regulating neurogenesis. These studies provide evidence that mammalian olfactory dysfunction due to Chd7 haploinsufficiency is linked to primary defects in olfactory neural stem cell proliferation and may influence olfactory bulb development.


Subject(s)
Abnormalities, Multiple/physiopathology , Cell Proliferation , DNA Helicases/genetics , DNA-Binding Proteins/genetics , Olfaction Disorders/physiopathology , Sensory Receptor Cells/cytology , Stem Cells/cytology , Abnormalities, Multiple/genetics , Abnormalities, Multiple/metabolism , Animals , Child , DNA Helicases/metabolism , DNA-Binding Proteins/metabolism , Disease Models, Animal , Female , Gene Expression , Humans , Male , Mice , Mice, Knockout , Mutation , Olfaction Disorders/genetics , Olfaction Disorders/metabolism , Olfactory Mucosa/cytology , Olfactory Mucosa/growth & development , Olfactory Mucosa/metabolism , Sensory Receptor Cells/metabolism , Smell , Stem Cells/metabolism
5.
Crit Rev Toxicol ; 41(4): 321-38, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21438739

ABSTRACT

The animal testing protocols used today to evaluate the carcinogenicity of chemicals are very different from those used in the earlier part of the 20th century. To explore how cancer bioassays have changed over time, we surveyed the literature discussing test design and interpretation from the 1930s to the present. We also analyzed compendia of bioassays published by the US Public Health Service (US PHS) from 1938 to 1978, and evaluated the data to understand the evolution of testing methodology (e.g., animals used, test duration) and the types of chemicals being studied. The cancer bioassay evolved in several stages. At the beginning of the 20th century, animal bioassays were primarily used to re-create known human diseases, whereas in the 1940s to 1960s, animal bioassays were largely used to evaluate the safety of chemicals in foods, drugs, and cosmetics. Beginning in the late 1960s and 1970s, chemicals primarily associated with occupational or environmental exposures were also evaluated. Testing strategies now emphasize a suite of tests including multiple in vitro tests and both short-term and long-term animal tests. The objectives of testing are broader, too, with test goals encompassing information regarding mode of action and other parameters aimed at evaluating potential species differences (e.g., in toxicokinetics) and their relevance for evaluating human risks. It is important to consider this evolution when evaluating the testing methodology and scientific conclusions in earlier eras. As toxicology continues to develop, testing methods will continue to change in concert with increased knowledge and understanding.


Subject(s)
Biological Assay/methods , Carcinogenicity Tests/methods , Carcinogens/toxicity , Environmental Pollutants/toxicity , Animals , Animals, Laboratory , Biological Assay/history , Carcinogenicity Tests/history , Disease Models, Animal , History, 20th Century , History, 21st Century , Humans , Risk Assessment
6.
J Surg Case Rep ; 2021(2): rjab008, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33604020

ABSTRACT

Upper gastrointestinal bleeding from esophagogastric varices is a common scenario, especially in patients with portal hypertension induced by liver cirrhosis or other diseases with thrombosis of the splenic vein. However, accessory spleen as pathophysiological cause of a regional, left-sided portal hypertension and consecutive development of isolated gastric varices is rare. We report a case of recurrent gastric variceal bleeding resulting from sinistral portal hypertension associated with an accessory spleen in a patient who had traumatic splenectomy many decades before. The accessory spleen is an extremely rare cause for the development of regional, left-sided portal hypertension leading to isolated gastric varices. Minimally invasive splenectomy is a safe and efficient treatment option.

7.
Clin Hemorheol Microcirc ; 76(2): 143-153, 2020.
Article in English | MEDLINE | ID: mdl-32925006

ABSTRACT

AIM: To evaluate the use of dynamic contrast enhanced ultrasound (CEUS) with parametric color-coded imaging and time intensity curve analysis (TIC) for planning and follow-up after prostate arterial embolization (PAE). MATERIAL/METHOD: Before and after selective iliacal embolization by PAE with a follow up of 6 months 18 male patients (43-78 years, mean 63±3.5 years) with histopathological proven benign prostate hyperplasia were examined by one experienced examiner. A multifrequency high resolution probe (1-6 MHz) was used for transabdominal ultrasound and CEUS with bolus injections of 2.4 ml sulphur-hexafluoride microbubbles. Independent evaluation of color-coded parametric imaging before and after PAE by in PACS stored DICOM loops from arterial phase (10-15 s) up to 1min were performed. Criteria for successful treatment were reduction of early arterial enhancement by changes of time to peak (TTP) and area under the curve (AUC) by measurements in 8 regions of interest (ROI) of 5 mm in diameter at the margin and in the center and changes from hyperenhancement in parametric imaging (perfusion evaluation of arterial enhancement over 15 s) from red and yellow to blue and green by partial infarctions. Reference imaging method was the contrast high resolution 3 tesla magnetic resonance tomography (MRI) using 3D vibe sequences before and after PAE and for the follow up after 3 and 6 months. RESULTS: PAE was technically and clinically successful in all 18 patients with less clinical symptoms and reduction of the gland volume. In all cases color-coded CEUS parametric imaging was able to evaluate partial infarction after embolization with changes from red and yellow to green and blue colors in the embolization areas. Relevant changes could be evaluated for TIC-analysis of CEUS with reduced arterial enhancement in the arterial phase and prolonged enhancement of up to 1 min with significant changes (p = 0.0024). The area under the curve (AUC) decreased from 676±255.04 rU (160 rU-1049 rU) before PAE to 370.43±255.19 rU (45 rU-858 rU) after PAE. Time to peak (TTP) did not change significantly (p = 0.6877); TTP before PAE was 25.82±9.04 s (12.3 s-42.5 s) and after PAE 24.43±9.10 s (12-39 s). Prostate volume decreased significantly (p = 0.0045) from 86.93±34.98 ml (30-139 ml) before PAE to 50.57±26.26 ml (19-117 ml) after PAE. There were no major complications and, in most cases (14/18) a volume reduction of the benign prostate hyperplasia occurred. CONCLUSION: Performed by an experienced examiner CEUS with parametric imaging and TIC-analysis is highly useful to further establish prostatic artery embolization (PAE) as a successful minimal invasive treatment of benign prostatic hyperplasia.


Subject(s)
Contrast Media/therapeutic use , Embolization, Therapeutic/methods , Prostatic Hyperplasia/surgery , Ultrasonography/methods , Adult , Aged , Humans , Male , Middle Aged , Prostatic Hyperplasia/drug therapy , Treatment Outcome
8.
Clin Hemorheol Microcirc ; 73(1): 95-104, 2019.
Article in English | MEDLINE | ID: mdl-31561349

ABSTRACT

OBJECTIVE: The use of a standardized dynamic contrast enhanced ultrasound (CEUS) protocol to determine perfusion of hepatocellular carcinomas (HCC) using quantitative analysis. METHODS: Retrospective analysis of 27 patients with hepatocellular carcinoma examined by a standardized protocol (bolus injection of 2.4 ml sulphur hexafluoride microbubbles, arterial phase to portal venous phase using continuous CINE-loops over 1 minute, short CINE-loops after 2, 3, 4, 5 and 6 minutes and additional single images for B-mode, CCDS). The examination was performed by an experienced sonographer with a high resolution, multi-frequency transducer (1-6 MHz). The reading of the reference imaging (contrast enhanced CT and MRI) and histopathology, if necessary, was performed independently. Retrospective analysis of the CEUS DICOM loops was done using time intensity curve analysis (TIC) with evaluation of the time to peak (TTP) and the area under the curve (AUC). RESULTS: All tumor lesions were characterized by CEUS, based on typical contrast patterns for HCC lesions with arterial enhancement and wash out in the late phase, corresponding to MRI with liver specific contrast agent or contrast enhanced CT. Mean TTP (SD) in the tumor centre (C) was 19.93 (11.31), in the periphery (P) 22.94 (9.44) and in the normal liver tissue (LT) 28.19 (11.34) with significant differences between all zones C/P (p = 0.013), C/LT (p = 0.005) and P/LT (p = 0.022). AUC mean (SD) in the tumor centre (C) was 660.03 (292.64), in the periphery (P) 586.04 (237.01) and in the normal liver tissue (LT) 484.20 (236.99), also with significant differences between all zones C/P (p = 0.001), C/LT (p < 0.001) and P/LT (p < 0.001). CONCLUSION: TIC-analysis is an easy-to-use tool for the dynamic evaluation of microvascularization in hepatocellular carcinoma and allows a fast and cost-efficient quantitative analysis.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Contrast Media/therapeutic use , Liver Neoplasms/diagnostic imaging , Microvessels/diagnostic imaging , Ultrasonography/methods , Aged , Aged, 80 and over , Carcinoma, Hepatocellular/pathology , Evaluation Studies as Topic , Female , Humans , Liver Neoplasms/pathology , Male , Microbubbles , Middle Aged , Retrospective Studies
9.
Clin Hemorheol Microcirc ; 72(1): 85-93, 2019.
Article in English | MEDLINE | ID: mdl-30584122

ABSTRACT

PURPOSE: To assess the postprocedure findings after percutaneous irreversible electroporation (IRE) of hepatocellular carcinoma (HCC) in contrast-enhanced ultrasound (CEUS). MATERIALS AND METHODS: Percutaneous IRE was performed in a total of 22 patients with 24 HCC tumours following interdisciplinary tumour board review. The lesions were documented using CEUS before, immediately and within 24 hours after IRE. During follow-up CEUS was performed at 6 weeks and 3, 9, and 12 months after ablation. Two experienced radiologists evaluated the acquired CEUS image date in a consensus reading. RESULTS: Median tumour size before treatment was 13.7±4.8 mm (short axis) and 16.0±5.2 mm (long axis). All HCC lesions showed arterial hyperenhancement in CEUS. Median size of the ablation defect after ablation was 29.3±5.2 mm (short axis) and 31.6±5.6 mm (long axis). After IRE all tumours showed complete devascularization. The size of the ablation defects showed significant shrinkage and reduced peripheral enhancement in the course of follow-up. At 12 months follow-up the ablation defect size decreased to 16.7±4.3 mm (short axis) and 18.3±4.1 mm (long axis). CONCLUSION: CEUS showed a complete devascularization of HCC tumours after IRE. Post-intervetional peripheral enhancement returned to normal during follow-up and may represent zones of reversible damage of cellular integrity through electroporation. A significant shrinkage of the ablation defects during 12 month of follow-up was seen in all cases.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Contrast Media/therapeutic use , Electroporation/methods , Liver Neoplasms/diagnostic imaging , Ultrasonography/methods , Carcinoma, Hepatocellular/pathology , Contrast Media/pharmacology , Female , Follow-Up Studies , Humans , Liver Neoplasms/pathology , Male , Middle Aged , Retrospective Studies , Time Factors
10.
Sci Rep ; 9(1): 19876, 2019 12 27.
Article in English | MEDLINE | ID: mdl-31882716

ABSTRACT

The incidence and evolution of venous thrombosis adjacent to the ablation zone after percutaneous irreversible electroporation (IRE) were evaluated to identify potential risk factors in patients with hepatic malignancies. 205 venous structures (in 87 patients) within a ≤1.0 cm radius of the ablation zone were assessed after IRE of 112 hepatic lesions (74 primary, 38 secondary hepatic malignancies) by pre-interventional and post-interventional (1-3 days, 6 weeks and 3 months after IRE) contrast-enhanced magnetic resonance imaging. The relationships between venous thrombosis and clinical features were analysed using a binary logistic regression model. In 27 of 87 patients (31%), a total of 67 venous complications were noted during the 3 months follow-up. Thrombosis represented the most frequently observed complication (n = 47; 70.1%), followed by vessel narrowing (n = 20; 29.9%). 5 (10.6%) of 47 thromboses showed spontaneous regression 3 months after IRE. A small vessel diameter (p = 0.011) and post-interventional vessel narrowing (p = 0.006) were independently associated with delayed post-ablative thrombosis. Delayed venous thrombosis frequently occurs after IRE of hepatic malignancies. Pre-existing vessel narrowing and a small vessel diameter represent significant risk factors that require further surveillance and potentially therapeutic intervention.


Subject(s)
Carcinoma, Hepatocellular/complications , Carcinoma, Hepatocellular/pathology , Electroporation , Liver Neoplasms/complications , Liver Neoplasms/pathology , Venous Thrombosis/etiology , Venous Thrombosis/pathology , Adult , Aged , Aged, 80 and over , Female , Humans , Incidence , Logistic Models , Male , Middle Aged , Retrospective Studies , Risk Factors , Venous Thrombosis/complications
11.
Int J Comput Assist Radiol Surg ; 13(12): 1991-1997, 2018 Dec.
Article in English | MEDLINE | ID: mdl-29728899

ABSTRACT

PURPOSE: To compare CT-navigated stereotactic microwave ablation (SMWA) to non-navigated conventional MWA (CMWA) for percutaneous ablation of liver malignancies. METHODS: A matched pair analysis of 36 patients who underwent MWA of primary or secondary liver malignancies (10 hepatocellular carcinoma and 8 metastases) was conducted. A total of 18 patients undergoing SMWA were included in this prospective study. Patients were matched in terms of tumor size, liver segment and entity to retrospective CMWA procedures. The endpoints were procedure time, accuracy of needle placement, technical success rate, complication rate and dose-length product (DLP). RESULTS: The procedure durations were 23.9 min (SD 3.7) for CMWA and 21.8 min (SD 16.3) for SMWA (p = 0.22). The procedural accuracy for SMWA and CMWA was identical for both groups (3.7 mm). The total DLP was significantly lower for SMWA than for CMWA (2115 mGy cm (SD 276) vs. 3109 mGy cm (SD 1137), respectively; p < 0.01). Complete ablation without residual tumor was observed in 94% (17 of 18) of SMWA and in 83% (15 of 18) of CMWA patients (p = 0.31). No complications occurred. CONCLUSIONS: SMWA is highly accurate and reduces the radiation dose without increasing the procedure time.


Subject(s)
Ablation Techniques/methods , Carcinoma, Hepatocellular/surgery , Imaging, Three-Dimensional , Liver Neoplasms/surgery , Microwaves/therapeutic use , Stereotaxic Techniques , Surgery, Computer-Assisted/methods , Carcinoma, Hepatocellular/diagnosis , Female , Humans , Liver Neoplasms/diagnosis , Male , Matched-Pair Analysis , Middle Aged , Prospective Studies , Treatment Outcome
12.
Clin Hemorheol Microcirc ; 69(1-2): 59-67, 2018.
Article in English | MEDLINE | ID: mdl-29758936

ABSTRACT

BACKGROUND:  With the rising number of percutaneous ablation therapies in malignant liver lesions there is a need of reliable diagnostics after the intervention to differentiate between reactive changes and tumor. PURPOSE: To assess the success of percutaneous ablation therapies for malignant liver lesions using CEUS with perfusion analysis. MATERIAL AND METHODS: Retrospective analysis of perfusion analysis for 67 patients with 94 malignant liver lesions, treated with ablation therapies. The lesions were 70 hepatocellular carcinomas (HCC), 18 metastases, 4 cholangiocellular carcinomas (CCC), 2 lesions remained unclear. CEUS was performed after bolus injection of 1.6-2.4 ml of sulfur-hexafluoride microbubbles. The perfusion analysis was calculated using Peak, TTP, mTT and AUC with integrated software during the late arterial to early portal-venous phase for approximately 9 sec (5-15 sec). For the evaluation of the success after percutaneous treatment the perfusion results were compared to the follow-up control after 6 months with CT and MRI and CEUS. RESULTS: Perfusion analyses after percutaneous treatment of malignant liver lesions showed highly significant perfusion differences when comparing the center to the surrounding tissue and the margins (p<0.0001) for Peak and also for AUC. 62 lesions were successfully treated, meaning there was no local recurrence after 6 months. In cases of residual tumor CEUS showed a nodular marginal enhancement, the corresponding perfusion analyses showed nodular red and yellow pseudo-color shades. CONCLUSIONS: Using CEUS and perfusion analysis, a critical analysis of post-ablation defects in malignant liver lesions is possible. With the help of pseudo-colors, remaining tumor-vascularization can be detected.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Contrast Media/therapeutic use , Liver Neoplasms/diagnostic imaging , Perfusion/methods , Ultrasonography/methods , Adult , Aged , Aged, 80 and over , Carcinoma, Hepatocellular/surgery , Female , Humans , Liver Neoplasms/surgery , Male , Middle Aged , Retrospective Studies
13.
Diagn Interv Imaging ; 98(9): 583-588, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28818346

ABSTRACT

Navigation systems have the potential to achieve a high accuracy for percutaneous ablation of tumors even for those in difficult locations. In the last years, successful research has been conducted to make navigation devices applicable to percutaneous tumor ablation with special planning software that now allows high accuracy even for deep-located small lesions close to critical structures. Because of the high number of available navigation systems, this review focuses on those with preexisting clinical studies.


Subject(s)
Neoplasms/diagnostic imaging , Neoplasms/surgery , Surgery, Computer-Assisted , Ablation Techniques , Electromagnetic Phenomena , Fiducial Markers , Humans , Robotic Surgical Procedures , Software
14.
Clin Hemorheol Microcirc ; 66(4): 277-282, 2017.
Article in English | MEDLINE | ID: mdl-28527198

ABSTRACT

To evaluate the effectiveness of high-resolution contrast-enhanced ultrasound (CEUS) to diagnose early post-operative complications in an interdisciplinary intensive care unit.In 50 patients (male 32; female 18) 64 CEUS examinations were performed in an intensive care unit (ICU) setting to detect post-operative complications. Multi-frequency transducer (1-5 and/or 6-9 MHz) were used. All 64 examinations were performed by one experienced examiner. CEUS findings were compared with contrast-enhanced computed tomography (CECT) findings. CECT images were acquired within 1-24 hours after CEUS examination in arterial and portal-venous phases of the abdomen using either a 16-slice computed tomography scanner or a 128-dual slice computed tomography scanner.In 56 out of 64 cases (88%) the CEUS-based diagnosis corresponded with the CECT diagnosis. Vascular stenosis in hepatic arteries and portal veins were recognised in both imaging modalities but were evaluated differently [5 cases]. In 3 cases (5%) small peripheral splenic infarction, retroperitoneal hematoma and fluid collection around the liver were not diagnosed by CEUS. CONCLUSION: CEUS in an ICU setting enables a reliable detection of postoperative abdominal complications as compared to CECT.


Subject(s)
Contrast Media/therapeutic use , Intensive Care Units/standards , Postoperative Complications/diagnostic imaging , Tomography, X-Ray Computed/methods , Ultrasonography/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Postoperative Complications/diagnosis , Young Adult
15.
Sci Rep ; 7(1): 9460, 2017 08 25.
Article in English | MEDLINE | ID: mdl-28842662

ABSTRACT

Aim of this study was to compare low tube voltage computed tomography (80 kV) of the liver using iterative image reconstruction (SAFIRE) with standard computed tomography (120 kV) using filtered back-projection (FBP) for the detection of hepatocellular carcinoma (HCC). 46 patients (43 men) with 93 HCC confirmed by 3 T MRI with Gd-EOB-DPTA, in inconclusive cases combined with contrast-enhanced ultrasound, underwent dual-energy CT. The raw data of the 80 kV tube was reconstructed using the iterative reconstruction algorithm SAFIRE with two strengths (I3 and I5). The virtual 120 kV image data set was reconstructed using FBP. The CT images were reviewed to determine the lesion-to-liver contrast (LLC), the lesion contrast-to-noise ratio (CNR) and the sensitivity. The LLC (57.1/54.3 [I3/I5] vs. 34.9 [FBP]; p ≤ 0.01), CNR (3.67/4.45 [I3/I5] vs. 2.48 [FBP]; p < 0.01) and sensitivity (91.4%/88.2% [I3/I5] vs. 72.0% [FBP]; p ≤ 0.01) were significantly higher in the low-voltage protocol using SAFIRE. Therefore, low tube voltage CT using SAFIRE results in an increased lesion-to-liver contrast as well as an improved lesion contrast-to-noise ratio compared to FBP at 120 kV which results in a higher sensitivity for the detection of HCC.


Subject(s)
Carcinoma, Hepatocellular/diagnosis , Liver Neoplasms/diagnosis , Liver/diagnostic imaging , Adult , Aged , Aged, 80 and over , Contrast Media , Female , Humans , Image Processing, Computer-Assisted , Liver/pathology , Male , Middle Aged , Phantoms, Imaging , Prospective Studies , Radiation Dosage , Sensitivity and Specificity , Tomography, X-Ray Computed , Ultrasonography
16.
Clin Hemorheol Microcirc ; 67(3-4): 383-388, 2017.
Article in English | MEDLINE | ID: mdl-28885205

ABSTRACT

PURPOSE: To determine the influence of pre-interventionally existing portal vein thrombosis on the ablation success of percutaneous tumor ablation of HCC. MATERIALS AND METHODS: 15 patients with HCC and pre-existing portal vein thrombosis underwent thermal tumor ablation. We retrospectively analyzed the pre- and post-interventionally performed CT and MRI scans in terms of technical success as well as the complication rate. The portal vein thrombosis was classified into segmental, lobar and central thrombus. RESULTS: In 13/15 cases (87%) complete ablation with no evidence of residual tumor tissue was seen 6 weeks after the procedure in contrast-enhanced MRI scans and contrast-enhanced ultrasound (CEUS). No major and 2 minor complications were observed after the ablation procedure. CONCLUSION: Reduced perfusion due to pre-interventionally existing portal vein thrombosis has no significant impact on the ablation success or the complication rate.


Subject(s)
Carcinoma, Hepatocellular/complications , Catheter Ablation/methods , Liver Neoplasms/complications , Portal Vein/pathology , Venous Thrombosis/etiology , Carcinoma, Hepatocellular/pathology , Female , Humans , Liver Neoplasms/pathology , Male , Middle Aged , Retrospective Studies , Venous Thrombosis/pathology
17.
Clin Hemorheol Microcirc ; 67(3-4): 373-382, 2017.
Article in English | MEDLINE | ID: mdl-28885204

ABSTRACT

PURPOSE: To compare the diagnostic performance of real-time maximum liver capacity (LiMAx) with dynamic contrast-enhanced ultrasound (CEUS)-based liver microcirculation. MATERIALS AND METHODS: 23 patients underwent liver function capacity (LiMAx) test and consecutive or previous CEUS examinations. A bolus injection of 1.4 ml sulfur hexafluoride microbubbles was administered for CEUS measurements (1-6 MHz) and quantitative perfusion analysis (TIC) was performed with an integrated perfusion software using stored cine-loops. Two perfusion-parameters, time to peak (TtoP) and area under the curve (Area), were evaluated in liver parenchyma and portal vein using TIC analysis.To compare quantification parameters, patients were classified in patients representing a healthy population (LiMAx value >315 µg/kg/h) and those representing patients with liver disease (LiMAx value <315 µg/kg/h). RESULTS: Comparing perfusion parameters derived from portal vein measurements, TtoP and Area were higher in patients with normal liver function TtoP: 25.0±8.4 s, Area: 1483±920 a.u. compared to patients with impaired liver function TtoP: 22.4±14.0 s; Area 1351±1212 a.u. This difference however was not statistically significant (p = 0.52, p = 0.48).In parameters derived from measurements in liver parenchyma TtoP was higher (38.5±11.3 s) and Area was lower (999±632 a.u.) in patients with normal liver function compared to patients with impaired liver function (TtoP; 30.6±11.0 s, p = 0.156; Area: 1202±719 a.u.) (p = 0.16, p = 0.56).In a simple linear regression model, none of the perfusion parameters measured in portal vein (TtoP portal, Area portal) and liver parenchyma (TtoP liver, Area liver) correlated significantly with respective LiMAx values (p = 0.194-0.950). CONCLUSION: Within the framework of this study, CEUS-based perfusion parameters were not able to assess severity of liver disease, assessed with LiMAx- test.


Subject(s)
Contrast Media/therapeutic use , Liver Diseases/physiopathology , Ultrasonography/methods , Female , Humans , Liver Diseases/diagnostic imaging , Male , Microcirculation , Middle Aged , Perfusion , Retrospective Studies
18.
Clin Hemorheol Microcirc ; 67(3-4): 399-405, 2017.
Article in English | MEDLINE | ID: mdl-28885207

ABSTRACT

OBJECTIVES: Irreversible electroporation (IRE) is a novel focal ablation technique applicable for treatment of prostate cancer (PCa). We aim to evaluate imaging findings of T1-weighted contrast-enhanced MRI after percutaneous IRE of low-risk PCa. METHODS: A total of 13 male patients underwent IRE of focal low-risk PCa and were included in this analysis. Prostate IRE was conducted using 2-4 electrodes being placed under CT-fluoroscopy guidance. Dynamic contrast-enhanced 3D isotropic fat-saturated T1-weighted MRI (DCE-MRI) was performed 24-72 hours before and 24-72 hours after ablation. RESULTS: Ablated prostate was either homogeneously (8/13 [62%]) or heterogeneously (5/13 [38%]) hypo attenuating. Peripheral contrast enhancement manifesting as a hyper attenuating margin was observed during the arterial (60 sec) (3/13 [23%]) and venous (240 sec) (10/13 [77%]) phase. The ablation defect showed a sharp (8/13 [62%]) or blurry (5/13 [38%]) margin. CONCLUSIONS: The results show a venous peripheral rim enhancement in most of the cases, indicating reactive hyperaemia. The heterogeneous appearance of the defect zone in some cases may be secondary to sustained vascularization.


Subject(s)
Contrast Media/therapeutic use , Electroporation/methods , Magnetic Resonance Imaging/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Humans , Male , Microcirculation , Middle Aged , Prostatic Neoplasms/pathology
19.
Clin Hemorheol Microcirc ; 67(3-4): 445-451, 2017.
Article in English | MEDLINE | ID: mdl-28885212

ABSTRACT

OBJECTIVE: To compare contrast-enhanced computed tomography (CT) and contrast-enhanced ultrasound (CEUS) for the quantitative evaluation of an ablation defect following radiofrequency ablation of malignant liver lesions in a prospective study. MATERIALS AND METHODS: 22 radiofrequency ablations of malignant liver tumors were performed. The ablation defects were then measured and evaluated by two independent examiners via contrast-enhanced computed tomography (CT) and contrast-enhanced ultrasound (CEUS) using a 1-5 MHz multifrequency convex ultrasound transducer (LOGIQ E9, GE) with respect to the short-axis diameter, the long-axis diameter, and the area. RESULTS: Quantitative evaluation of ablation defects is possible with both contrast-enhanced CT and CEUS. The average long-axis diameter was 47.1 mm (±11.08;±23,5%) on CEUS and 56.48 mm (±14.14;±25,0%) on CT; the short-axis diameter was 39.72 mm (±11.14;±28,05%) on CEUS and 40.27 mm (±10.50;±26,07%) on CT; the area was 1439.82 mm2 (±678.57;±47,13%) on CEUS and 2392.68 mm2 (1147.67;±48,0%) on CT. On average, ablation defects are assessed to be larger on CT than on CEUS. A significant correlation between the modalities could not be achieved for all measurement axes. CONCLUSION: CEUS can be used for the postinterventional detection and evaluation of ablation defects. However, these are always assessed to be larger on contrast-enhanced CT than CEUS.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Catheter Ablation/methods , Contrast Media/therapeutic use , Liver Neoplasms/diagnostic imaging , Tomography, X-Ray Computed/methods , Ultrasonography/methods , Carcinoma, Hepatocellular/pathology , Female , Humans , Liver Neoplasms/pathology , Male , Middle Aged , Prospective Studies
20.
Clin Hemorheol Microcirc ; 66(4): 357-368, 2017.
Article in English | MEDLINE | ID: mdl-28598835

ABSTRACT

AIM: To evaluate the efficiency of intraoperative contrast enhanced ultrasound (Io-CEUS) for assessment of radiofrequency ablation (RFA) during liver tumor surgery. MATERIAL AND METHODS: Retrospective analysis was performed on a total number of 18 patients out of over 500 patients who underwent combined liver tumor surgery and RFA of 27 hepatic tumors between 02/2011 and 12/2016. Io-CEUS was performed by bolus injections of up to 10 ml sulphur hexaflourid microbubbles for diagnostic purposes. To guide the RFA up to 20 ml microbubbles were applied to monitor the procedure and assess the ablation status finally. A fully avascular area or absence of any residual vascularization intratumorally was considered technical success. These findings were correlated to findings of follow-up imaging results (CEUS, MRI, CT) at least 1 up to 40 months (mean 11 months) after surgery. RESULTS: 13 male and 5 female patients aged between 45-77 years (mean 59.2±17.1 years) with 26 malignant and one most probable benign hepatic lesion were treated with intraoperative RFA. Io-CEUS detected 23 preoperatively unknown liver lesions leading to a change in therapy in 13/18 cases (72,2%). All 27 treated lesions showed an avascular area immediately after RFA. According to follow-up imaging results (1 month - 3 years after surgery, mean follow-up time 11 months), 2/18 patients had local recurrences, 8 patients had distant intrahepatic recurrences or extrahepatic recurrence, 8 patients remained tumor-free. Thereby, a success rate of CEUS guided RFA of 89% could be obtained concerning the targeted liver lesions. CONCLUSION: Modern intraoperative ultrasound using B-mode and Io-CEUS is a valuable tool for optimization of diagnostic and therapeutic intraoperative liver procedures and ablative therapies.


Subject(s)
Catheter Ablation/methods , Contrast Media/therapeutic use , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/therapy , Ultrasonography/methods , Aged , Female , Humans , Liver Neoplasms/pathology , Male , Middle Aged , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL