1.
J Cardiovasc Electrophysiol ; 35(1): 130-135, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37975539

ABSTRACT

INTRODUCTION: Cavo-tricuspid isthmus (CTI) dependent atrial flutter (AFL) is one of the most common atrial arrhythmias involving the right atrium (RA) for which radiofrequency catheter ablation has been widely used as a therapy of choice. However, there is limited data on the effect of this intervention on cardiac size and function. METHODS: A retrospective study was conducted on 468 patients who underwent ablation for CTI dependent typical AFL at a single institution between 2010 and 2019. After excluding patients with congenital or rheumatic heart disease, heart transplant recipients, or those without baseline echocardiogram, a total of 130 patients were included in the analysis. Echocardiographic data were analyzed at baseline before ablation, and at early follow-up within 1-year postablation. Follow-up echocardiographic data was available for 55 patients. RESULTS: Of the 55 patients with CTI-AFL, the mean age was 64.2 ± 14.8 years old with 14.5% (n = 8) female. The average left ventricular ejection fraction (LVEF) significantly improved on follow-up echo (40.2 ± 16.9 to 50.4 ± 14.9%, p < .0001), of which 50% of patients had an improvement in LVEF of at least 10%. There was a significant reduction in left atrial volume index (82.74 ± 28.5 to 72.96 ± 28 mL/m2 , p = .008) and RA volume index (70.62 ± 25.6 to 64.15 ± 31 mL/m2 , p = .046), and a significant improvement in left atrial reservoir strain (13.04 ± 6.8 to 19.10 ± 7.7, p < .0001). CONCLUSIONS: Patients who underwent CTI dependent AFL ablation showed an improvement in cardiac size and function at follow-up evaluation. While long-term results are still unknown, these findings indicate that restoration of sinus rhythm in patients with typical AFL is associated with improvement in atrial size and left ventricular function.


Subject(s)
Atrial Flutter , Catheter Ablation , Humans , Female , Middle Aged , Aged , Atrial Flutter/diagnostic imaging , Atrial Flutter/surgery , Retrospective Studies , Stroke Volume , Ventricular Function, Left , Catheter Ablation/adverse effects , Catheter Ablation/methods , Treatment Outcome
2.
J Cardiovasc Electrophysiol ; 35(7): 1401-1411, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38738814

ABSTRACT

INTRODUCTION: Ablation of scar-related reentrant atrial tachycardia (SRRAT) involves identification and ablation of a critical isthmus. A graph convolutional network (GCN) is a machine learning structure that is well-suited to analyze the irregularly-structured data obtained in mapping procedures and may be used to identify potential isthmuses. METHODS: Electroanatomic maps from 29 SRRATs were collected, and custom electrogram features assessing key tissue and wavefront properties were calculated for each point. Isthmuses were labeled off-line. Training data was used to determine the optimal GCN parameters and train the final model. Putative isthmus points were predicted in the training and test populations and grouped into proposed isthmus areas based on density and distance thresholds. The primary outcome was the distance between the centroids of the true and closest proposed isthmus areas. RESULTS: A total of 193 821 points were collected. Thirty isthmuses were detected in 29 tachycardias among 25 patients (median age 65.0, 5 women). The median (IQR) distance between true and the closest proposed isthmus area centroids was 8.2 (3.5, 14.4) mm in the training and 7.3 (2.8, 16.1) mm in the test group. The mean overlap in areas, measured by the Dice coefficient, was 11.5 ± 3.2% in the training group and 13.9 ± 4.6% in the test group. CONCLUSION: A GCN can be trained to identify isthmus areas in SRRATs and may help identify critical ablation targets.


Subject(s)
Action Potentials , Catheter Ablation , Cicatrix , Electrophysiologic Techniques, Cardiac , Heart Rate , Predictive Value of Tests , Tachycardia, Supraventricular , Humans , Female , Male , Cicatrix/physiopathology , Cicatrix/diagnosis , Middle Aged , Aged , Tachycardia, Supraventricular/physiopathology , Tachycardia, Supraventricular/surgery , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/etiology , Automation , Machine Learning , Treatment Outcome , Signal Processing, Computer-Assisted
3.
J Cardiovasc Nurs ; 36(5): 470-481, 2021.
Article in English | MEDLINE | ID: mdl-32675627

ABSTRACT

BACKGROUND: Depression and anxiety in patients with atrial fibrillation (AF) and/or atrial flutter may influence the effectiveness of cardioversion and ablation. There is a lack of knowledge related to depressive symptoms and anxiety at the time of these procedures. OBJECTIVE: We aimed to describe the prevalence and explore potential covariates of depressive symptoms and anxiety in patients with AF at the time of cardioversion or ablation. We further explored the influence of depressive symptoms and anxiety on quality of life at the time of procedure and 6-month AF recurrence. METHODS: Depressive symptoms, anxiety, and quality of life were collected at the time of cardioversion or ablation using the Patient Health Questionnaire-9, State-Trait Anxiety Inventory, and Atrial Fibrillation Effect on Quality of Life questionnaire. Presence of AF recurrence within 6 months post procedure was evaluated. RESULTS: Participants (N = 171) had a mean (SD) age of 61.20 (11.23) years and were primarily male (80.1%) and white, non-Hispanic (81.4%). Moderate to severe depressive symptoms (17.2%) and clinically significant state (30.2%) and trait (23.6%) anxiety were reported. Mood/anxiety disorder diagnosis was associated with all 3 symptoms. Atrial fibrillation symptom severity was associated with both depressive symptoms and trait anxiety. Heart failure diagnosis and digoxin use were also associated with depressive symptoms. Trends toward significance between state and trait anxiety and participant race/ethnicity as well as depressive symptoms and body mass index were observed. Study findings support associations between symptoms and quality of life, but not 6-month AF recurrence. CONCLUSION: Depressive symptoms and anxiety are common in patients with AF. Healthcare providers should monitor patients with AF for depressive symptoms and anxiety at the time of procedures and intervene when indicated. Additional investigations on assessment, prediction, treatment, and outcome of depressive symptoms and anxiety in patients with AF are warranted.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Anxiety/epidemiology , Anxiety Disorders , Atrial Fibrillation/complications , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Atrial Flutter/epidemiology , Atrial Flutter/therapy , Depression/epidemiology , Depression/therapy , Electric Countershock , Humans , Male , Middle Aged , Quality of Life , Recurrence , Treatment Outcome
4.
J Cardiovasc Electrophysiol ; 31(6): 1249-1254, 2020 06.
Article in English | MEDLINE | ID: mdl-32281214

ABSTRACT

A global coronavirus (COVID-19) pandemic occurred at the start of 2020 and is already responsible for more than 74 000 deaths worldwide, just over 100 years after the influenza pandemic of 1918. At the center of the crisis is the highly infectious and deadly SARS-CoV-2, which has altered everything from individual daily lives to the global economy and our collective consciousness. Aside from the pulmonary manifestations of disease, there are likely to be several electrophysiologic (EP) sequelae of COVID-19 infection and its treatment, due to consequences of myocarditis and the use of QT-prolonging drugs. Most crucially, the surge in COVID-19 positive patients that have already overwhelmed the New York City hospital system requires conservation of hospital resources including personal protective equipment (PPE), reassignment of personnel, and reorganization of institutions, including the EP laboratory. In this proposal, we detail the specific protocol changes that our EP department has adopted during the COVID-19 pandemic, including performance of only urgent/emergent procedures, after hours/7-day per week laboratory operation, single attending-only cases to preserve PPE, appropriate use of PPE, telemedicine and video chat follow-up appointments, and daily conferences to collectively manage the clinical and ethical dilemmas to come. We discuss also discuss how we perform EP procedures on presumed COVID positive and COVID tested positive patients to highlight issues that others in the EP community may soon face in their own institution as the virus continues to spread nationally and internationally.


Subject(s)
Academic Medical Centers/supply & distribution , Betacoronavirus , Coronavirus Infections/diagnosis , Electrophysiology/methods , Personal Protective Equipment/standards , Pneumonia, Viral/diagnosis , COVID-19 , Humans , Pandemics , SARS-CoV-2
5.
J Cardiovasc Electrophysiol ; 31(12): 3086-3096, 2020 12.
Article in English | MEDLINE | ID: mdl-33022765

ABSTRACT

INTRODUCTION: Electrocardiographic characteristics in COVID-19-related mortality have not yet been reported, particularly in racial/ethnic minorities. METHODS AND RESULTS: We reviewed demographics, laboratory and cardiac tests, medications, and cardiac rhythm proximate to death or initiation of comfort care for patients hospitalized with a positive SARS-CoV-2 reverse-transcriptase polymerase chain reaction in three New York City hospitals between March 1 and April 3, 2020 who died. We described clinical characteristics and compared factors contributing toward arrhythmic versus nonarrhythmic death. Of 1258 patients screened, 133 died and were enrolled. Of these, 55.6% (74/133) were male, 69.9% (93/133) were racial/ethnic minorities, and 88.0% (117/133) had cardiovascular disease. The last cardiac rhythm recorded was VT or fibrillation in 5.3% (7/133), pulseless electrical activity in 7.5% (10/133), unspecified bradycardia in 0.8% (1/133), and asystole in 26.3% (35/133). Most 74.4% (99/133) died receiving comfort measures only. The most common abnormalities on admission electrocardiogram included abnormal QRS axis (25.8%), atrial fibrillation/flutter (14.3%), atrial ectopy (12.0%), and right bundle branch block (11.9%). During hospitalization, an additional 17.6% developed atrial ectopy, 14.7% ventricular ectopy, 10.1% atrial fibrillation/flutter, and 7.8% a right ventricular abnormality. Arrhythmic death was confirmed or suspected in 8.3% (11/133) associated with age, coronary artery disease, asthma, vasopressor use, longer admission corrected QT interval, and left bundle branch block (LBBB). CONCLUSIONS: Conduction, rhythm, and electrocardiographic abnormalities were common during COVID-19-related hospitalization. Arrhythmic death was associated with age, coronary artery disease, asthma, longer admission corrected QT interval, LBBB, ventricular ectopy, and usage of vasopressors. Most died receiving comfort measures.


Subject(s)
Arrhythmias, Cardiac/mortality , COVID-19/mortality , Hospital Mortality , Aged , Aged, 80 and over , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/ethnology , Arrhythmias, Cardiac/therapy , COVID-19/diagnosis , COVID-19/ethnology , COVID-19/therapy , Cause of Death , Comorbidity , Electrocardiography , Female , Heart Disease Risk Factors , Hospital Mortality/ethnology , Hospitalization , Humans , Male , Middle Aged , New York City/epidemiology , Prognosis , Race Factors , Retrospective Studies , Risk Assessment , Time Factors
6.
J Cardiovasc Nurs ; 35(4): 327-336, 2020.
Article in English | MEDLINE | ID: mdl-32015256

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is associated with high recurrence rates and poor health-related quality of life (HRQOL) but few effective interventions to improve HRQOL exist. OBJECTIVE: The aim of this study was to examine the impact of the "iPhone Helping Evaluate Atrial Fibrillation Rhythm through Technology" (iHEART) intervention on HRQOL in patients with AF. METHODS: We randomized English- and Spanish-speaking adult patients with AF to receive either the iHEART intervention or usual care for 6 months. The iHEART intervention used smartphone-based electrocardiogram monitoring and motivational text messages. Three instruments were used to measure HRQOL: the Atrial Fibrillation Effect on Quality of Life (AFEQT), the 36-item Short-Form Health survey, and the EuroQol-5D. We used linear mixed models to compare the effect of the iHEART intervention on HRQOL, quality-adjusted life-years, and AF symptom severity. RESULTS: A total of 238 participants were randomized to the iHEART intervention (n = 115) or usual care (n = 123). Of the participants, 77% were men and 76% were white. More than half (55%) had an AF recurrence. Both arms had improved scores from baseline to follow-up for AFEQT and AF symptom severity scores. The global AFEQT score improved 18.5 and 11.2 points in the intervention and control arms, respectively (P < .05). There were no statistically significant differences in HRQOL, quality-adjusted life-years, or AF symptom severity between groups. CONCLUSIONS: We found clinically meaningful improvements in AF-specific HRQOL and AF symptom severity for both groups. Additional research with longer follow-up should examine the influence of smartphone-based interventions for AF management on HRQOL and address the unique needs of patients diagnosed with different subtypes of AF.


Subject(s)
Atrial Fibrillation/diagnosis , Electrocardiography/instrumentation , Monitoring, Ambulatory/methods , Signal Processing, Computer-Assisted/instrumentation , Smartphone/statistics & numerical data , Aged , Atrial Fibrillation/physiopathology , Female , Humans , Male , Middle Aged , Monitoring, Physiologic , Quality of Life , Surveys and Questionnaires , Text Messaging/statistics & numerical data
7.
Indian Pacing Electrophysiol J ; 20(6): 250-256, 2020.
Article in English | MEDLINE | ID: mdl-32861812

ABSTRACT

BACKGROUND: The COVID-19 pandemic has greatly altered the practice of cardiac electrophysiology around the world for the foreseeable future. Professional organizations have provided guidance for practitioners, but real-world examples of the consults and responsibilities cardiac electrophysiologists face during a surge of COVID-19 patients is lacking. METHODS: In this observational case series we report on 29 consecutive inpatient electrophysiology consultations at a major academic medical center in New York City, the epicenter of the pandemic in the United States, during a 2 week period from March 30-April 12, 2020, when 80% of hospital beds were occupied by COVID-19 patients, and the New York City metropolitan area accounted for 10% of COVID-19 cases worldwide. RESULTS: Reasons for consultation included: Atrial tachyarrhythmia (31%), cardiac implantable electronic device management (28%), bradycardia (14%), QTc prolongation (10%), ventricular arrhythmia (7%), post-transcatheter aortic valve replacement conduction abnormality (3.5%), ventricular pre-excitation (3.5%), and paroxysmal supraventricular tachycardia (3.5%). Twenty-four patients (86%) were positive for COVID-19 by nasopharyngeal swab. All elective procedures were canceled, and only one urgent device implantation was performed. Thirteen patients (45%) required in-person evaluation and the remainder were managed remotely. CONCLUSION: Our experience shows that the application of a massive alteration in workflow and personnel forced by the pandemic allowed our team to efficiently address the intersection of COVID-19 with a range of electrophysiology issues. This experience will prove useful as guidance for emerging hot spots or areas affected by future waves of the pandemic.

8.
J Cardiovasc Electrophysiol ; 30(11): 2220-2228, 2019 11.
Article in English | MEDLINE | ID: mdl-31507001

ABSTRACT

OBJECTIVE: This study evaluated the impact of daily ECG (electrocardiogram) self-recordings on time to documented recurrent atrial fibrillation (AF) or atrial flutter (AFL) and time to treatment of recurrent arrhythmia in patients undergoing catheter radiofrequency ablation (RFA) or direct current cardioversion (DCCV) for AF/AFL. BACKGROUND: AF recurrence rates after RFA and DCCV are 20% to 45% and 60% to 80%, respectively. Randomized trials comparing mobile ECG devices to standard of care have not been performed in an AF/AFL population after treatment. METHODS: Of 262 patients consented, 238 were randomized to either standard of care (123) or to receive the iHEART intervention (115). Patients in the intervention group were provided with and trained to use an AliveCor KardiaMobile ECG monitor, and were instructed to take and transmit daily ECG recordings. Data were collected from transmitted ECG recordings and patients' electronic health records. RESULTS: In a multivariate Cox model, the likelihood of recurrence detection was greater in the intervention group (hazard ratio = 1.56, 95% confidence interval [CI]: 1.06-2.30, P = .024). Hazard ratios did not differ significantly for RFA and DCCV procedures. Recurrence during the first month after ablation strongly predicted later recurrence (hazard ratio = 4.53, 95% CI: 2.05-10.00, P = .0006). Time from detection to treatment was shorter for the control group (hazard ratio = 0.33, 95% CI: 0.57-2.92, P < .0001). CONCLUSIONS: The use of mobile ECG self-recording devices allows for earlier detection of AF/AFL recurrence and may empower patients to engage in shared health decision-making.


Subject(s)
Action Potentials , Atrial Fibrillation/therapy , Atrial Flutter/therapy , Cell Phone , Electric Countershock , Electrocardiography, Ambulatory/instrumentation , Heart Rate , Radiofrequency Ablation , Remote Sensing Technology/instrumentation , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Flutter/diagnosis , Atrial Flutter/physiopathology , Electric Countershock/adverse effects , Female , Humans , Male , Middle Aged , Mobile Applications , New York City , Predictive Value of Tests , Prospective Studies , Radiofrequency Ablation/adverse effects , Recurrence , Reproducibility of Results , Risk Assessment , Risk Factors , Self Care , Time Factors , Treatment Outcome
9.
Pacing Clin Electrophysiol ; 42(5): 542-547, 2019 05.
Article in English | MEDLINE | ID: mdl-30829416

ABSTRACT

BACKGROUND: Leadless pacemakers (LPMs) have been shown to have lower postoperative complications than traditional permanent pacemakers but there have been no studies on the outcomes of LPMs in patients with transcatheter heart valve replacements (THVRs). This study determined outcomes of LPMs compared to transvenous single-chamber pacemakers (SCPs) post-THVR. METHODS: This is a retrospective single-center study including 10 patients who received LPMs post-THVR between February 2017 and August 2018 and a comparison group of 23 patients who received SCP post-THVR between July 2008 and August 2018. LPM or SCP was implanted at the discretion of electrophysiologists for atrial fibrillation with slow ventricular response or sinus node dysfunction with need for single-chamber pacing only. RESULTS: LPMs were associated with decreased tricuspid regurgitation (P = 0.04) and decreased blood loss during implantation (7.5 ± 2.5 cc for LPMs vs 16.8 ± 3.2 cc for SCPs, P = 0.03). Five LPM patients had devices positioned in the right ventricular septum as seen on transthoracic echocardiogram. Frequency of ventricular pacing was similar between LPM and SCP groups. In the LPM group, one case was complicated by a pseudoaneurysm and one death was due to noncardiac causes. There was one pneumothorax and one pocket infection in the SCP group. CONCLUSIONS: In this small retrospective study, LPMs were feasible post-THVR and found to perform as well as SCPs, had less intraprocedural blood loss, and were associated with less tricuspid regurgitation. Further, larger studies are required to follow longer-term outcomes and complications.


Subject(s)
Cardiac Pacing, Artificial/methods , Cardiac Surgical Procedures , Pacemaker, Artificial , Postoperative Complications/prevention & control , Transcatheter Aortic Valve Replacement , Tricuspid Valve Insufficiency/prevention & control , Aged, 80 and over , Echocardiography , Female , Humans , Male , Prosthesis Design , Retrospective Studies
12.
Pacing Clin Electrophysiol ; 40(4): 391-400, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28151545

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) prevalence increases significantly with age. Little is known about the effect of AF ablation on quality of life and healthcare utilization in the elderly. The objective of this study was to quantify the healthcare utilization and quality of life benefits of catheter ablation for AF, for patients ≥65 years compared to patients <65 years. METHODS: Two multicenter U.S. registry studies enrolled patients with paroxysmal AF. Baseline characteristics and acute outcomes were collected for 736 patients receiving catheter ablation with the Navistar® ThermoCool® SF Catheter (Biosense Webster, Inc., Diamond Bar, CA, USA). Healthcare utilization and quality of life outcomes were collected through 1 year postablation for 508 patients. RESULTS: The rates of acute pulmonary vein isolation were high and similar between patients ≥65 years and <65 years (97.5% vs 95.8%, P = 0.2130). Length of stay for the index procedure was similar between age groups with 82.2% of the older group and 83.2% of the younger group having one-day hospitalization. Disease-specific quality of life instrument scores improved significantly and similarly for older and younger patients at 1 year postablation, compared to baseline. AF-related hospitalizations and emergency department visits were similar or lower in older patients compared to younger patients, as reported at 1 year postablation. CONCLUSION: For older patients undergoing catheter ablation for paroxysmal AF, healthcare utilization parameters were lower or not significantly different than for younger patients, and quality of life outcomes were similarly improved. These findings support the use of catheter ablation as a treatment option in older patients with paroxysmal AF.


Subject(s)
Atrial Fibrillation/psychology , Atrial Fibrillation/surgery , Catheter Ablation/psychology , Catheter Ablation/statistics & numerical data , Health Services Accessibility/statistics & numerical data , Quality of Life/psychology , Adult , Age Distribution , Aged , Aged, 80 and over , Atrial Fibrillation/epidemiology , Female , Humans , Male , Middle Aged , Prevalence , Retrospective Studies , Sex Distribution , Treatment Outcome , United States/epidemiology , Utilization Review , Young Adult
13.
J Cardiovasc Electrophysiol ; 26(11): 1187-1195, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26228873

ABSTRACT

INTRODUCTION: Atrial fibrillation (AF) ablation patients often manifest atrial tachycardias (AT) with atypical ECG morphologies that preclude accurate localization and mechanism. Diagnostic maneuvers used to define ATs during electrophysiology studies can be limited by tachycardia termination or transformation. Additional methods of characterizing post-AF ablation ATs are required. METHODS AND RESULTS: We evaluated the utility of noninvasive ECG signal analytics in postablation AF patients for the following features: (1) Localization of ATs (i.e., right vs. left atrium), and (2) Identification of common left AT mechanisms (i.e., focal vs. macroreentrant). Atrial waveforms from the surface ECG were used to analyze (1) spectral organization, including dominant amplitude (DA) and mean spectral profile (MP), and (2) temporospatial variability, using temporospatial correlation coefficients. We studied 94 ATs in 71 patients who had undergone prior pulmonary vein isolation for AF and returned for a second ablation: (1) right atrial cavotricuspid-isthmus dependent (CTI) ATs (n = 21); (2) left atrial macroreentrant ATs (n = 41) and focal ATs (n = 32). Right CTI ATs manifested higher DAs and lower MPs than left ATs, indicative of greater stability and less complexity in the frequency spectrum. Left macroreentrant ATs possessed higher temporospatial organization than left focal ATs. CONCLUSIONS: Noninvasively recorded atrial waveform signal analyses show that right ATs possess more stable activation properties than left ATs, and left macroreentrant ATs manifest higher temporospatial organization than left focal ATs. Further prospective analyses evaluating the role these novel ECG-derived tools can play to help localize and identify mechanisms of common ATs in AF ablation patients are warranted.

14.
Curr Opin Cardiol ; 30(3): 259-66, 2015 May.
Article in English | MEDLINE | ID: mdl-25807223

ABSTRACT

PURPOSE OF REVIEW: Patients with atrial fibrillation and heart failure experience an increased morbidity and mortality from the hemodynamic consequences of atrial fibrillation and an increased stroke risk. Consequently, there has been increased attention to procedural alternatives to pharmacologic rhythm control and anticoagulation for stroke prevention. This review aims to evaluate the evidence for atrial fibrillation ablation and left atrial appendage closure in heart failure patients. RECENT FINDINGS: Several randomized control trials and systematic reviews demonstrate the safety and efficacy of atrial fibrillation ablation in patients with heart failure and left ventricular systolic dysfunction. In multiple trials, these patients have shown clinical benefit from atrial fibrillation ablation including improved left ventricular systolic function, quality of life, and clinical heart failure symptoms. The evidence of clinical benefit of atrial fibrillation ablation in heart failure patients with preserved ejection fraction remains limited. Only a handful of randomized controlled trials have been performed evaluating left atrial appendage closure, and there is insufficient data regarding the safety and efficacy of these procedures in heart failure patients. SUMMARY: Atrial fibrillation ablation in heart failure patients remains well tolerated with an overall efficacy comparable to atrial fibrillation ablation in patients without heart failure. There is consistent evidence for the clinical benefit of atrial fibrillation ablation in heart failure patients with left ventricular systolic dysfunction and limited evidence for atrial fibrillation ablation in heart failure patients with preserved ejection fraction. Currently, there is insufficient data regarding the safety and efficacy of left atrial appendage closure devices in heart failure patients.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Failure/complications , Stroke/prevention & control , Ventricular Dysfunction, Left/complications , Atrial Fibrillation/complications , Humans , Septal Occluder Device , Stroke/etiology , Treatment Outcome
15.
Eur Heart J ; 35(2): 69-76, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24144789

ABSTRACT

Current interventional procedures in structural heart disease and cardiac arrhythmias require peri-interventional echocardiographic monitoring and guidance to become as safe, expedient, and well-tolerated for patients as possible. Intracardiac echocardiography (ICE) complements and has in part replaced transoesophageal echocardiography (TEE), including real-time three-dimensional (RT-3D) imaging. The latter is still widely accepted as a method to prepare for and to guide interventional treatments. In contrast to TEE, ICE represents a purely intraprocedural guiding and imaging tool unsuitable for diagnostic purposes. Patients tolerate ICE much better, and the method does not require general anaesthesia. Accurate imaging of the particular pathology, its anatomic features, and spatial relation to the surrounding structures is critical for catheter and wire positioning, device deployment, evaluation of the result, and for ruling out complications. This review describes the peri-interventional role of ICE, outlines current limitations, and points out future implications. Two-dimensional ICE has become a suitable guiding tool for a variety of percutaneous treatments in patients who are conscious or under monitored anaesthesia care, whereas RT-3DICE is still undergoing clinical testing. Continuous TEE monitoring under general anaesthesia remains a widely accepted alternative.


Subject(s)
Echocardiography/methods , Heart Diseases/diagnostic imaging , Atrial Appendage/surgery , Cardiac Catheterization/economics , Cardiac Catheterization/methods , Cardiology/education , Cost-Benefit Analysis , Echocardiography/economics , Europe , Heart Valve Prosthesis Implantation/methods , Humans , Intraoperative Care/methods , Mitral Valve Annuloplasty/methods , Septal Occluder Device , Ultrasonography, Interventional/economics , Ultrasonography, Interventional/methods , United States , Wound Closure Techniques
16.
J Cardiovasc Electrophysiol ; 25(8): 852-858, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24602038

ABSTRACT

INTRODUCTION: This report presents safety data on the use of a new open-irrigation radiofrequency ablation (RFA) catheter with a 56-hole porous tip in 742 patients enrolled in 2 US prospective, multicenter observational registry studies representing real-world use of the catheter. METHODS: This analysis is comprised of patients who underwent RFA of drug-refractory recurrent symptomatic paroxysmal atrial fibrillation (AF). Acute adverse events (AEs) were collected and categorized by seriousness, timing, and relatedness, with 7 days of follow-up data in one study and at least 120 days of data from a 1-year follow-up in the other. Acute serious adverse events (SAEs) that were identified as potentially related to the device and/or procedure were adjudicated by an independent safety committee. RESULTS: A total of 30 patients (4.0%) in the combined studies experienced an acute SAE related to the device and/or procedure, which was similar in the subset of patients age 65 and over (4.2%). These SAEs included 1.2% cardiac tamponade/perforation, 0.7% pericarditis, 0.5% pulmonary events, and 0.8% vascular access complications. No myocardial infarction, stroke, transient ischemic attack, or atrioesophageal fistulas within 7 days postprocedure were reported. In the study with extended follow-up, 1 pulmonary vein stenosis and 1 esophageal injury were seen beyond 7 days postprocedure (0.2% each). There were no device or procedure related deaths. CONCLUSION: Results from 2 large observational studies demonstrated that a new porous tip RFA catheter was safe for the treatment of drug refractory, recurrent, symptomatic paroxysmal AF, including treatment of older patients (≥65 years).


Subject(s)
Atrial Fibrillation/surgery , Cardiac Catheters , Catheter Ablation/instrumentation , Therapeutic Irrigation/instrumentation , Aged , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Equipment Design , Female , Humans , Male , Middle Aged , Prospective Studies , Recurrence , Registries , Risk Factors , Therapeutic Irrigation/adverse effects , Time Factors , Treatment Outcome , United States
17.
Pacing Clin Electrophysiol ; 37(1): 79-89, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24033806

ABSTRACT

BACKGROUND: Although local electrograms during atrial fibrillation (AF) are often spectrally analyzed over 8-second (8s) intervals, changes may be common over intervals as short as 2s. We sought to determine whether averaged 2s measurements of electrogram spectral parameters were similar to 8s measurements, and whether the 2s intervals could provide an estimate of the temporal stability of the signal frequency content in paroxysmal versus persistent AF. METHODS: Complex fractionated atrial electrograms (CFAEs) were acquired outside the pulmonary vein ostia and from free wall sites in nine paroxysmal and 10 longstanding persistent AF patients. Using a 2s sliding calculation window, a frequency spectrum was computed every 100 ms over an interval of 8.4 seconds (82 spectra in total). The dominant frequency (DF), the dominant amplitude (DA), and the mean spectral profile (MP) were measured. The 2s measurements were compared to single 8.4-second interval measurements. Coefficients of variation (COV) were computed from the 82 spectra for each CFAE recording to determine temporal variability of parameters. RESULTS: Over the sliding 2s computation intervals, as for fixed 8.4-second computation intervals, mean DA and DF were significantly higher in longstanding persistent AF while MP was significantly higher in paroxysmal AF (P ≤ 0.001). The COV was significantly higher for the DF parameter in paroxysmal AF (P < 0.001) and significantly higher for the MP parameter in persistent AF (P < 0.02). CONCLUSIONS: For both paroxysmal and persistent AF data, the 2s sliding window averages provide similar results to single 8.4-second intervals, and information regarding temporal stability was additionally obtained in the process.


Subject(s)
Algorithms , Artifacts , Atrial Fibrillation/diagnosis , Body Surface Potential Mapping/methods , Data Interpretation, Statistical , Diagnosis, Computer-Assisted/methods , Electrophysiologic Techniques, Cardiac/methods , Humans , Reproducibility of Results , Sensitivity and Specificity , Time Factors
18.
Pacing Clin Electrophysiol ; 37(3): 336-44, 2014 Mar.
Article in English | MEDLINE | ID: mdl-23998759

ABSTRACT

BACKGROUND: When atrial fibrillation (AF) is incessant, imaging during a prolonged ventricular RR interval may improve image quality. It was hypothesized that long RR intervals could be predicted from preceding RR values. METHODS: From the PhysioNet database, electrocardiogram RR intervals were obtained from 74 persistent AF patients. An RR interval lengthened by at least 250 ms beyond the immediately preceding RR interval (termed T0 and T1, respectively) was considered prolonged. A two-parameter scatterplot was used to predict the occurrence of a prolonged interval T0. The scatterplot parameters were: (1) RR variability (RRv) estimated as the average second derivative from 10 previous pairs of RR differences, T13-T2, and (2) Tm-T1, the difference between Tm, the mean from T13 to T2, and T1. For each patient, scatterplots were constructed using preliminary data from the first hour. The ranges of parameters 1 and 2 were adjusted to maximize the proportion of prolonged RR intervals within range. These constraints were used for prediction of prolonged RR in test data collected during the second hour. RESULTS: The mean prolonged event was 1.0 seconds in duration. Actual prolonged events were identified with a mean positive predictive value (PPV) of 80% in the test set. PPV was >80% in 36 of 74 patients. An average of 10.8 prolonged RR intervals per 60 minutes was correctly identified. CONCLUSIONS: A method was developed to predict prolonged RR intervals using two parameters and prior statistical sampling for each patient. This or similar methodology may help improve cardiac imaging in many longstanding persistent AF patients.


Subject(s)
Algorithms , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Diagnosis, Computer-Assisted/methods , Electrocardiography/methods , Heart Conduction System/physiopathology , Heart Rate , Heart Ventricles/physiopathology , Humans , Reproducibility of Results , Sensitivity and Specificity
19.
Biomed Eng Online ; 13: 61, 2014 May 09.
Article in English | MEDLINE | ID: mdl-24886214

ABSTRACT

BACKGROUND: Real-time spectral analyzers can be difficult to implement for PC computer-based systems because of the potential for high computational cost, and algorithm complexity. In this work a new spectral estimator (NSE) is developed for real-time analysis, and compared with the discrete Fourier transform (DFT). METHOD: Clinical data in the form of 216 fractionated atrial electrogram sequences were used as inputs. The sample rate for acquisition was 977 Hz, or approximately 1 millisecond between digital samples. Real-time NSE power spectra were generated for 16,384 consecutive data points. The same data sequences were used for spectral calculation using a radix-2 implementation of the DFT. The NSE algorithm was also developed for implementation as a real-time spectral analyzer electronic circuit board. RESULTS: The average interval for a single real-time spectral calculation in software was 3.29 µs for NSE versus 504.5 µs for DFT. Thus for real-time spectral analysis, the NSE algorithm is approximately 150× faster than the DFT. Over a 1 millisecond sampling period, the NSE algorithm had the capability to spectrally analyze a maximum of 303 data channels, while the DFT algorithm could only analyze a single channel. Moreover, for the 8 second sequences, the NSE spectral resolution in the 3-12 Hz range was 0.037 Hz while the DFT spectral resolution was only 0.122 Hz. The NSE was also found to be implementable as a standalone spectral analyzer board using approximately 26 integrated circuits at a cost of approximately $500. The software files used for analysis are included as a supplement, please see the Additional files 1 and 2. CONCLUSIONS: The NSE real-time algorithm has low computational cost and complexity, and is implementable in both software and hardware for 1 millisecond updates of multichannel spectra. The algorithm may be helpful to guide radiofrequency catheter ablation in real time.


Subject(s)
Algorithms , Electrocardiography/methods , Electrophysiologic Techniques, Cardiac/methods , Signal Processing, Computer-Assisted , Software , Electrical Equipment and Supplies , Electrocardiography/instrumentation , Electrophysiologic Techniques, Cardiac/instrumentation , Equipment Design , Humans
20.
Eur Heart J Case Rep ; 8(8): ytae303, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39104515

ABSTRACT

Background: Atrial fibrillation (AF) is a prevalent cardiac condition characterized by irregular heart rhythm. Conventional non-invasive diagnostic techniques, while useful, have limitations in providing comprehensive information for treatment planning. To address this gap, electromechanical cycle length mapping (ECLM), a non-invasive echocardiography-based technique, has emerged as a promising approach. Electromechanical cycle length mapping offers quantitative and spatially specific insights into atrial electromechanical activation rate mapping, thereby enhancing our understanding of arrhythmia disease progression in AF patients. Case summary: In this case series, we present two patient cases demonstrating the potential utility of ECLM in monitoring and evaluating treatment responses in atrial arrhythmia. The 1st case involved a 61-year-old male with persistent AF who underwent multiple procedures, including direct current cardioversion (DCCV) and radiofrequency ablation. Over three different DCCV encounters, pre- and post-procedure ECLM scans were performed, and the results showed the localization and incomplete elimination of arrhythmic triggers post-DCCV, which were used as early indicators of AF recurrence. The 2nd case involved a 71-year-old male with paroxysmal AF who also underwent cardioversion and ablation procedures. Electromechanical cycle length mapping imaging demonstrated a progressive reduction and elimination of arrhythmia triggers after each encounter, resulting in long-term maintenance of sinus rhythm. Discussion: The findings from this case series highlight the potential of ECLM as a non-invasive imaging tool for long-term monitoring and evaluating immediate and long-term treatment responses in AF patients. The integration of ECLM with standard echocardiograms holds promise in guiding clinical decisions and improving patient outcomes in managing atrial fibrillation.

SELECTION OF CITATIONS