Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Eur Heart J ; 35(17): 1120-30, 2014 May.
Article in English | MEDLINE | ID: mdl-24255127

ABSTRACT

AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA-SPECT/MPI and ICA alone was 38 and 59%, respectively. The patient-based diagnostic accuracy defined by the area under the receiver operating characteristic curve (AUC) of integrated CTA-CTP for detecting or excluding flow-limiting CAD was 0.87 [95% confidence interval (CI): 0.84-0.91]. In patients without prior myocardial infarction, the AUC was 0.90 (95% CI: 0.87-0.94) and in patients without prior CAD the AUC for combined CTA-CTP was 0.93 (95% CI: 0.89-0.97). For the combination of a CTA stenosis ≥50% stenosis and a CTP perfusion deficit, the sensitivity, specificity, positive predictive, and negative predicative values (95% CI) were 80% (72-86), 74% (68-80), 65% (58-72), and 86% (80-90), respectively. For flow-limiting disease defined by ICA-SPECT/MPI, the accuracy of CTA was significantly increased by the addition of CTP at both the patient and vessel levels. CONCLUSIONS: The combination of CTA and perfusion correctly identifies patients with flow limiting CAD defined as ≥50 stenosis by ICA causing a perfusion defect by SPECT/MPI.


Subject(s)
Coronary Stenosis/diagnostic imaging , Tomography, Emission-Computed, Single-Photon/methods , Aged , Coronary Stenosis/physiopathology , Female , Hemodynamics/physiology , Humans , Male , Middle Aged , Multidetector Computed Tomography , Myocardial Perfusion Imaging/methods , Prospective Studies , ROC Curve , Sensitivity and Specificity
2.
N Engl J Med ; 359(22): 2324-36, 2008 Nov 27.
Article in English | MEDLINE | ID: mdl-19038879

ABSTRACT

BACKGROUND: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. METHODS: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. RESULTS: A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. CONCLUSIONS: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.)


Subject(s)
Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Tomography, X-Ray Computed , Aged , Angina Pectoris/classification , Angina Pectoris/diagnostic imaging , Area Under Curve , Coronary Angiography/adverse effects , Female , Humans , Male , Middle Aged , Predictive Value of Tests , ROC Curve , Sensitivity and Specificity , Severity of Illness Index , Single-Blind Method , Technology Assessment, Biomedical , Tomography, X-Ray Computed/adverse effects , Tomography, X-Ray Computed/methods
3.
Eur Radiol ; 19(4): 816-28, 2009 Apr.
Article in English | MEDLINE | ID: mdl-18998142

ABSTRACT

Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective "CORE-64" trial ("Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors"). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.


Subject(s)
Coronary Angiography/instrumentation , Coronary Angiography/methods , Coronary Artery Disease/diagnosis , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/methods , Clinical Trials as Topic , Contrast Media/pharmacology , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/anatomy & histology , Equipment Design , Humans , Interinstitutional Relations , Quality Assurance, Health Care , Reproducibility of Results , Research Design , Sample Size
4.
Int J Cardiol ; 201: 570-7, 2015 Dec 15.
Article in English | MEDLINE | ID: mdl-26334382

ABSTRACT

BACKGROUND: Myocardial CT perfusion (CTP) has been validated as an incremental diagnostic predictor over coronary computed tomography angiography (CTA) in assessing hemodynamically significant stenosis. OBJECTIVES: To assess the diagnostic performance of CTA and CTP alone versus combined CTA-CTP stratified by Morise's pre-test probability and coronary artery calcium (CAC, Agatston) score. METHODS: 381 individuals (153 low/intermediate-risk for CAD, 83 high-risk, 145 known CAD) were further stratified based on CAC score cut-offs of 1-399 and ≥400. Area under the curve for receiver operating characteristics (AUC) was calculated to assess the diagnostic performance. Reference standards were QCA≥50% stenosis+corresponding SPECT summed stress score ≥1. RESULTS: In both pre-test risk groups with an Agatston score of 1-399, AUCs of CTA-CTP were not significantly different than that from CTA alone. In the low/intermediate-risk group with CAC score 1-399, AUC for CTA-CTP (89) was higher than that for CTP (76, p=0.003) alone. In the same group with CAC score ≥400, AUCs were higher for CTA-CTP (97) than that for CTA (88, p=0.030) and CTP (83, p=0.033). In high risk/known CAD patients with CAC 1-399, diagnostic performance for CTA-CTP (77) was superior to CTP (71, p=0.037) alone. In the high risk/known CAD group with CAC score ≥400, AUCs for combined imaging were higher (86) than that for CTA (75, p<0.001) as well as CTP (78, p=0.020). CONCLUSIONS: The incremental diagnostic accuracy of CTP over CTA persists in patients across severity spectra of pre-test probability of CAD and coronary artery calcification. In patients with severe coronary calcification (CAC score≥400), combined CTA-CTP has better diagnostic accuracy than CTA and CTP alone.


Subject(s)
Coronary Angiography/methods , Coronary Artery Disease/diagnosis , Coronary Vessels , Multidetector Computed Tomography/methods , Myocardial Perfusion Imaging/methods , Tomography, Emission-Computed, Single-Photon/methods , Vascular Calcification/diagnosis , Aged , Aged, 80 and over , Coronary Vessels/diagnostic imaging , Female , Follow-Up Studies , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , ROC Curve , Reproducibility of Results , Severity of Illness Index
5.
Pain ; 52(1): 93-99, 1993 Jan.
Article in English | MEDLINE | ID: mdl-8446442

ABSTRACT

The ischemic pain associated with balloon inflation during coronary angioplasty remains a significant source of procedural discomfort and sets a limit on the duration of percutaneous transluminal intravascular interventions. The present study examined whether intracoronary lidocaine reduced the pain of coronary angioplasty. Sixteen patients undergoing elective coronary angioplasty underwent three 90 sec balloon inflations: the first with administration of no intracoronary agent, and the second and third with administration of one or the other of placebo or an equal volume of lidocaine (10-16 mg). Placebo or lidocaine were randomized in administration sequence and were given just before balloon inflation. During the occlusions, pain was scored on an ordinal scale (0 = no pain; 10 = most severe pain). Lidocaine delayed the onset of pain (23 +/- 4 vs. 48 +/- 7 sec, P < 0.005) and reduced its magnitude (at end-inflation: 7.8 +/- 1.3 vs. 3.2 +/- 1.3, P < 0.01). There were no significant hemodynamic or electrophysiologic effects in this group of patients, although atrioventricular conduction was delayed when lidocaine was administered into the epicardial coronary which had the atrioventricular node artery as a branch. Intracoronary analgesia with lidocaine is safe and effective in a select group of patients with normal ventricular function undergoing elective coronary angioplasty.


Subject(s)
Analgesia , Angioplasty, Balloon/adverse effects , Lidocaine/therapeutic use , Pain/drug therapy , Aged , Coronary Vessels , Double-Blind Method , Echocardiography , Electrocardiography , Electrophysiology , Female , Hemodynamics/drug effects , Humans , Injections , Lidocaine/administration & dosage , Lidocaine/adverse effects , Male , Middle Aged , Pain/etiology , Pain Measurement/drug effects
6.
J Am Coll Cardiol ; 55(7): 627-34, 2010 Feb 16.
Article in English | MEDLINE | ID: mdl-20170786

ABSTRACT

OBJECTIVES: This study was designed to evaluate whether the absence of coronary calcium could rule out >or=50% coronary stenosis or the need for revascularization. BACKGROUND: The latest American Heart Association guidelines suggest that a calcium score (CS) of zero might exclude the need for coronary angiography among symptomatic patients. METHODS: A substudy was made of the CORE64 (Coronary Evaluation Using Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors) multicenter trial comparing the diagnostic performance of 64-detector computed tomography to conventional angiography. Patients clinically referred for conventional angiography were asked to undergo a CS scan up to 30 days before. RESULTS: In all, 291 patients were included, of whom 214 (73%) were male, and the mean age was 59.3 +/- 10.0 years. A total of 14 (5%) patients had low, 218 (75%) had intermediate, and 59 (20%) had high pre-test probability of obstructive coronary artery disease. The overall prevalence of >or=50% stenosis was 56%. A total of 72 patients had CS = 0, among whom 14 (19%) had at least 1 >or=50% stenosis. The overall sensitivity for CS = 0 to predict the absence of >or=50% stenosis was 45%, specificity was 91%, negative predictive value was 68%, and positive predictive value was 81%. Additionally, revascularization was performed in 9 (12.5%) CS = 0 patients within 30 days of the CS. From a total of 383 vessels without any coronary calcification, 47 (12%) presented with >or=50% stenosis; and from a total of 64 totally occluded vessels, 13 (20%) had no calcium. CONCLUSIONS: The absence of coronary calcification does not exclude obstructive stenosis or the need for revascularization among patients with high enough suspicion of coronary artery disease to be referred for coronary angiography, in contrast with the published recommendations. Total coronary occlusion frequently occurs in the absence of any detectable calcification. (Coronary Evaluation Using Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors [CORE-64]; NCT00738218).


Subject(s)
Calcinosis/diagnostic imaging , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Occlusion/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Myocardial Revascularization , Age Factors , Coronary Occlusion/therapy , Coronary Stenosis/therapy , Female , Humans , Linear Models , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Referral and Consultation , Sensitivity and Specificity , Sex Factors , Tomography, X-Ray Computed/methods
7.
Pacing Clin Electrophysiol ; 29(4): 436-7, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16650277

ABSTRACT

We report the use of a long wire and introducer as a rail for the laser recanalization of a chronically occluded subclavian vein following extraction of a fractured permanent pacing lead. This allowed new pacing leads to be placed through the previously occluded vessel.


Subject(s)
Electrodes, Implanted/adverse effects , Laser Therapy/instrumentation , Laser Therapy/methods , Pacemaker, Artificial/adverse effects , Peripheral Vascular Diseases/etiology , Peripheral Vascular Diseases/surgery , Subclavian Vein/surgery , Child , Humans , Male
SELECTION OF CITATIONS