Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Eur Heart J ; 39(31): 2867-2875, 2018 08 14.
Article in English | MEDLINE | ID: mdl-29617764

ABSTRACT

Aims: Electroanatomical voltage mapping (EAVM) is an important diagnostic tool for fibrosis identification and risk stratification in non-ischaemic cardiomyopathy (NICM); currently, distinct cut-offs are applied. We aimed to evaluate the performance of EAVM to detect fibrosis by integration with whole heart histology and to identify the fibrosis pattern in NICM patients with ventricular tachycardias (VTs). Methods and results: Eight patients with NICM and VT underwent EAVM prior to death or heart transplantation. EAVM data was projected onto slices of the entire heart. Pattern, architecture, and amount of fibrosis were assessed in transmural biopsies corresponding to EAVM sites. Fibrosis pattern in NICM biopsies (n = 507) was highly variable and not limited to mid-wall/sub-epicardium. Fibrosis architecture was rarely compact, but typically patchy and/or diffuse. In NICM, biopsies without abnormal fibrosis unipolar voltage (UV) and bipolar voltage (BV) showed a linear association with wall thickness (WT). The amount of viable myocardium showed a linear association with both UV and BV. Accordingly, any cut-off to delineate fibrosis performed poorly. An equation was generated calculating the amount of fibrosis at any location, given WT and UV or BV. Conclusion: Considering the linear relationships between WT, amount of fibrosis and both UV and BV, the search for any distinct voltage cut-off to identify fibrosis in NICM is futile. The amount of fibrosis can be calculated, if WT and voltages are known. Fibrosis pattern and architecture are different from ischaemic cardiomyopathy and findings on ischaemic substrates may not be applicable to NICM.


Subject(s)
Cardiomyopathies/pathology , Cardiomyopathies/physiopathology , Epicardial Mapping , Tachycardia, Ventricular/pathology , Tachycardia, Ventricular/physiopathology , Aged , Fibrosis , Humans , Male , Middle Aged , Risk Assessment
2.
Radiother Oncol ; 194: 110145, 2024 May.
Article in English | MEDLINE | ID: mdl-38341093

ABSTRACT

BACKGROUND AND PURPOSE: Adaptive radiotherapy (ART) relies on re-planning to correct treatment variations, but the optimal timing of re-planning to account for dose changes in head and neck organs at risk (OARs) is still under investigation. We aimed to find out the optimal timing of re-planning in head and neck ART. MATERIALS AND METHODS: A total of 110 head and neck cancer patients were retrospectively enrolled. A semi auto-segmentation method was applied to obtain the weekly mean dose (Dmean) to OARs. The K-nearest-neighbour method was used for missing data imputation of weekly Dmean. A dose deviation map was built using the planning Dmean and weekly Dmean values and then used to simulate different ART scenarios consisting of 1 to 6 re-plannings. The difference between accumulated Dmean and planning Dmean before re-planning (ΔDmean_acc_noART) and after re-planning (ΔDmean_acc_ART) were evaluated and compared. RESULTS: Among all the OARs, supraglottic showed the largest ΔDmean_acc_noART (1.23 ± 3.13 Gy) and most cases of ΔDmean_acc_noART > 3 Gy (26 patients). The 3rd week is suggested in the optimal timing of re-planning for 10 OARs. For all the organs except arytenoid, 2 re-plannings were able to guarantee the ΔDmean_acc_ART below 3 Gy while the average |ΔDmean_acc_ART| was below 1 Gy. ART scenarios of 2_4, 3_4, 3_5 (week of re-planning separated with "_") were able to guarantee ΔDmean_acc_ART of 99 % of patients below 3 Gy simultaneously for 19 OARs. CONCLUSIONS: The optimal timing of re-planning was suggested for different organs at risk in head and neck adaptive radiotherapy. Generic scenarios of timing and frequency for re-planning can be applied to guarantee the increase of accumulated mean dose within 3 Gy simultaneously for multiple organs.


Subject(s)
Head and Neck Neoplasms , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Head and Neck Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies , Organs at Risk/radiation effects , Male , Female , Middle Aged , Aged , Time Factors , Adult , Radiotherapy, Intensity-Modulated/methods , Aged, 80 and over
3.
Phys Imaging Radiat Oncol ; 31: 100600, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39022396

ABSTRACT

Background and purpose: Introducing moderately hypofractionated salvage radiotherapy (SRT) following prostatectomy obligates investigation of its effects on clinical target volume (CTV) coverage and organ-at-risk (OAR) doses. This study assessed interfractional volume and dose changes in OARs and CTV in moderately hypofractionated SRT and evaluated the 8-mm planning target volume (PTV) margin. Materials and methods: Twenty patients from the PERYTON-trial were included; 10 received conventional SRT (35 × 2 Gy) and 10 hypofractionated SRT (20 × 3 Gy). OARs were delineated on 539 pre-treatment Cone Beam CT (CBCT) scans to compare interfractional OAR volume changes. CTVs for the hypofractionated group were delineated on 199 CBCTs. Dose distributions with 4 and 6 mm PTV margins were generated using voxel-wise minimum robustness evaluation of the original 8-mm PTV plan, and dose changes were assessed. Results: Median volume changes for bladder and rectum were -26 % and -10 %, respectively. OAR volume changes were not significantly different between the two treatment schedules. The 8-mm PTV margin ensured optimal coverage for prostate bed and vesicle bed CTV (V95 = 100 % in >97 % fractions). However, bladder V60 <25 % was not achieved in 5 % of fractions, and rectum V60 <5 % was unmet in 33 % of fractions. A 6-mm PTV margin resulted in CTV V95 = 100 % in 92 % of fractions for prostate bed, and in 86 % for vesicle bed CTV. Conclusions: Moderately hypofractionated SRT yielded comparable OAR volume changes to conventionally fractionated SRT. Interfractional changes remained acceptable with a PTV margin of 6 mm for prostate bed and 8 mm for vesicle bed.

4.
JACC Clin Electrophysiol ; 10(6): 1050-1060, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38613544

ABSTRACT

BACKGROUND: Atrial tachycardia (AT) and atrial fibrillation (AF) coexist in 30% of congenital heart disease (CHD) patients. Successful atrial tachycardia catheter ablation (ATCA) might prevent AF. Data on new-onset AF after ATCA in CHD is scarce. OBJECTIVES: This study aimed to evaluate the incidence of new-onset AF after ATCA and to assess clinical characteristics associated with new-onset AF after ATCA in CHD. METHODS: CHD patients referred for ATCA to 3 European centers were included. New occurrence of AF was defined as electrocardiographic documentation of AF after any ATCA procedure in patients without history of AF. RESULTS: In 277 CHD patients (median age 37 years [Q1, Q3: 23, 49 years], 58% men, 59 [21%] simple, 111 [40%] moderate, and 107 [39%] complex CHD), AF occurred in 25 patients (9%) a median of 8 months (Q1, Q3: 4, 27 months) after ATCA. New-onset AF was persistent in the majority of the patients (17 of 25 [63%]). Patients with new-onset AF were older (44 years [Q1, Q3: 29, 55 years] vs 36 years [Q1, Q3: 23, 49 years]; P = 0.009) and more frequently had simple CHD (13 of 25 [52%] vs 46 of 252 [18%], respectively; P < 0.0001). Acute ATCA success rates were similar in patients with and without AF (52% vs 48%; P = 0.429). Simple CHD was an independent predictor of new-onset AF during follow-up. CONCLUSIONS: In our large cohort of patients with congenital heart disease, new-onset AF after ablation for AT occurred in only 9% of the patients. AF occurred without AT recurrence and was persistent in the majority of patients.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Defects, Congenital , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Male , Female , Catheter Ablation/adverse effects , Middle Aged , Adult , Heart Defects, Congenital/surgery , Heart Defects, Congenital/complications , Heart Defects, Congenital/epidemiology , Incidence , Young Adult , Electrocardiography
5.
Cancers (Basel) ; 16(5)2024 Feb 22.
Article in English | MEDLINE | ID: mdl-38473254

ABSTRACT

Proton therapy is a promising modality for craniospinal irradiation (CSI), offering dosimetric advantages over conventional treatments. While significant attention has been paid to spine fields, for the brain fields, only dose reduction to the lens of the eye has been reported. Hence, the objective of this study is to assess the potential gains and feasibility of adopting different treatment planning techniques for the entire brain within the CSI target. To this end, eight previously treated CSI patients underwent retrospective replanning using various techniques: (1) intensity modulated proton therapy (IMPT) optimization, (2) the modification/addition of field directions, and (3) the pre-optimization removal of superficially placed spots. The target coverage robustness was evaluated and dose comparisons for lenses, cochleae, and scalp were conducted, considering potential biological dose increases. The target coverage robustness was maintained across all plans, with minor reductions when superficial spot removal was utilized. Single- and multifield optimization showed comparable target coverage robustness and organ-at-risk sparing. A significant scalp sparing was achieved in adults but only limited in pediatric cases. Superficial spot removal contributed to scalp V30 Gy reduction at the expense of lower coverage robustness in specific cases. Lens sparing benefits from multiple field directions, while cochlear sparing remains impractical. Based on the results, all investigated plan types are deemed clinically adoptable.

6.
Phys Med ; 123: 103407, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38906046

ABSTRACT

PURPOSE: To investigate the current practice patterns in image-guided particle therapy (IGPT) for cranio-spinal irradiation (CSI). METHODS: A multi-institutional survey was distributed to European particle therapy centres to analyse all aspects of IGPT. Based on the survey results, a Delphi consensus analysis was developed to define minimum requirements and optimal workflow for clinical practice. The centres participating in the institutional survey were invited to join the Delphi process. RESULTS: Eleven centres participated in the survey. Imaging for treatment planning was rather similar among the centres with Computed Tomography (CT) being the main modality. For positioning verification, 2D IGPT was more commonly used than 3D IGPT. Two centres performed routinely imaging for plan adaptation, by the rest ad hoc. Eight centres participated in the Delphi consensus analysis. The full consensus was reached on the use of CT imaging without contrast for treatment planning and the role of magnetic resonance imaging (MRI) in target and organs-at-risk delineation. There was an agreement on the necessity to perform patient position verification and correction before each isocentre. The most important outcome was the clear need for standardization and harmonization of the workflow. CONCLUSION: There were differences in CSI IGPT clinical practice among the European particle therapy centres. Moreover, the optimal workflow as identified by experts was not yet reached. There is a strong need for consensus guidelines. The state-of-the-art imaging technology and protocols need to be implemented into clinical practice to improve the quality of IGPT for CSI.


Subject(s)
Radiotherapy, Image-Guided , Humans , Radiotherapy, Image-Guided/methods , Europe , Craniospinal Irradiation/methods , Surveys and Questionnaires , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed , Delphi Technique , Magnetic Resonance Imaging
7.
Int J Radiat Oncol Biol Phys ; 118(3): 688-696, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-37729971

ABSTRACT

PURPOSE: Prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT) scan is the standard imaging procedure for biochemical recurrent prostate cancer postprostatectomy because of its high detection rate at low serum prostate-specific antigen levels. However, existing guidelines for clinical target volume (CTV) in prostate bed salvage external beam radiation therapy (sEBRT) are primarily based on experience-based clinical consensus and have been validated using conventional imaging modalities. Therefore, this study aimed to optimize CTV definition in sEBRT by using PSMA PET/CT-detected local recurrences (LRs). METHODS AND MATERIALS: Patients with suspected LR on PSMA PET/CT postprostatectomy were retrospectively enrolled in 9 Dutch centers. Anonymized scans were centrally reviewed by an expert nuclear medicine physician. Each boundary of the CTV guideline from the Groupe Francophone de Radiothérapie en Urologie (GFRU) was evaluated and adapted to improve the accuracy and coverage of the area at risk of LR (CTV) on PSMA PET/CT. The proposed CTV adaptation was discussed with the radiation oncologists of the participating centers, and final consensus was reached. To assess reproducibility, the participating centers were asked to delineate 3 new cases according to the new PERYTON-CTV, and the submitted contours were evaluated using the Dice similarity coefficient (DSC). RESULTS: After central review, 93 LRs were identified on 83 PSMA PET/CTs. The proposed CTV definition improved the coverage of PSMA PET/CT-detected LRs from 67% to 96% compared with the GFRU-CTV, while reducing the GFRU-CTV by 25%. The new CTV was highly reproducible, with a mean DSC of 0.82 (range, 0.81-0.83). CONCLUSIONS: This study contributes to the optimization of CTV definition in postprostatectomy sEBRT by using the pattern of LR detected on PSMA PET/CT. The PERYTON-CTV is highly reproducible across the participating centers and ensures coverage of 96% LRs while reducing the GFRU-CTV by 25%.


Subject(s)
Positron Emission Tomography Computed Tomography , Prostatic Neoplasms , Male , Humans , Positron Emission Tomography Computed Tomography/methods , Retrospective Studies , Reproducibility of Results , Prostate/diagnostic imaging , Neoplasm Recurrence, Local/diagnostic imaging , Neoplasm Recurrence, Local/radiotherapy , Neoplasm Recurrence, Local/surgery , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/surgery , Prostatectomy/methods , Gallium Radioisotopes , Prostate-Specific Antigen
8.
Adv Radiat Oncol ; 9(2): 101379, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38405312

ABSTRACT

Purpose: The PERYTON trial is a multicenter randomized controlled trial that will investigate whether the treatment outcome of salvage external beam radiation therapy (sEBRT) will be improved with hypofractionated radiation therapy. A pretrial quality assurance (QA) program was undertaken to ensure protocol compliance within the PERYTON trial and to assess variation in sEBRT treatment protocols between the participating centers. Methods and Materials: Completion of the QA program was mandatory for each participating center (N = 8) to start patient inclusion. The pretrial QA program included (1) a questionnaire on the center-specific sEBRT protocol, (2) a delineation exercise of the clinical target volume (CTV) and organs at risk, and (3) a treatment planning exercise. All contours were analyzed using the pairwise dice similarity coefficient (DSC) and the 50th and 95th percentile Hausdorff distance (HD50 and HD95, respectively). The submitted treatment plans were reviewed for protocol compliance. Results: The results of the questionnaire showed that high-quality, state-of-the-art radiation therapy techniques were used in the participating centers and identified variations of the sEBRT protocols used concerning the position verification and preparation techniques. The submitted CTVs showed significant variation, with a range in volume of 29 cm3 to 167 cm3, a mean pairwise DSC of 0.52, and a mean HD50 and HD95 of 2.3 mm and 24.4 mm, respectively. Only in 1 center the treatment plan required adaptation before meeting all constraints of the PERYTON protocol. Conclusions: The pretrial QA of the PERYTON trial demonstrated that high-quality, but variable, radiation techniques were used in the 8 participating centers. The treatment planning exercise confirmed that the dose constraints of the PERYTON protocol were feasible for all participating centers. The observed variation in CTV delineation led to agreement on a new (image-based) delineation guideline to be used by all participating centers within the PERYTON trial.

9.
Phys Imaging Radiat Oncol ; 27: 100460, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37435559

ABSTRACT

Stereotactic body radiotherapy (SBRT) is increasingly applied for pelvic oligometastases of prostate cancer, and currently no simple immobilization method is available for cone beam computed tomography (CBCT)-guided treatment. We assessed patient set-up and intrafraction motion using simple immobilization during CBCT-guided pelvic SBRT. Forty patients were immobilized with basic arm- head- and knee support and either a thermoplastic cushion or a foam cushion. Analysis of 454 CBCTs showed mean intrafraction translation <3.0 mm in 94% of fractions and mean intrafraction rotation <1.5° in 95% of fractions. Therefore, simple immobilization ensured stable patient positioning during CBCT-guided pelvic SBRT.

10.
Phys Imaging Radiat Oncol ; 27: 100474, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37560512

ABSTRACT

Inter- and intra-fractional prostate motion can deteriorate the dose distribution in extremely hypofractionated intensity-modulated proton therapy. We used verification CTs and prostate motion data calculated from 1024 intra-fractional prostate motion records to develop a voxel-wise based 4-dimensional method, which had a time resolution of 1 s, to assess the dose impact of prostate motion. An example of 100 fractional simulations revealed that motion had minimal impact on planning dose, the accumulated dose in 95 % of the scenarios fulfilled the clinical goals for target coverage (D95 > 37.5 Gy). This method can serve as a complementary measure in clinical setting to guarantee plan quality.

11.
Radiother Oncol ; 186: 109747, 2023 09.
Article in English | MEDLINE | ID: mdl-37330053

ABSTRACT

BACKGROUND AND PURPOSE: To date, data used in the development of Deep Learning-based automatic contouring (DLC) algorithms have been largely sourced from single geographic populations. This study aimed to evaluate the risk of population-based bias by determining whether the performance of an autocontouring system is impacted by geographic population. MATERIALS AND METHODS: 80 Head Neck CT deidentified scans were collected from four clinics in Europe (n = 2) and Asia (n = 2). A single observer manually delineated 16 organs-at-risk in each. Subsequently, the data was contoured using a DLC solution, and trained using single institution (European) data. Autocontours were compared to manual delineations using quantitative measures. A Kruskal-Wallis test was used to test for any difference between populations. Clinical acceptability of automatic and manual contours to observers from each participating institution was assessed using a blinded subjective evaluation. RESULTS: Seven organs showed a significant difference in volume between groups. Four organs showed statistical differences in quantitative similarity measures. The qualitative test showed greater variation in acceptance of contouring between observers than between data from different origins, with greater acceptance by the South Korean observers. CONCLUSION: Much of the statistical difference in quantitative performance could be explained by the difference in organ volume impacting the contour similarity measures and the small sample size. However, the qualitative assessment suggests that observer perception bias has a greater impact on the apparent clinical acceptability than quantitatively observed differences. This investigation of potential geographic bias should extend to more patients, populations, and anatomical regions in the future.


Subject(s)
Deep Learning , Humans , Tomography, X-Ray Computed , Algorithms , Observer Variation , Europe , Organs at Risk , Radiotherapy Planning, Computer-Assisted
12.
Radiother Oncol ; 186: 109763, 2023 09.
Article in English | MEDLINE | ID: mdl-37353058

ABSTRACT

BACKGROUND AND PURPOSE: Adaptive radiotherapy (ART) is workload intensive but only benefits a subgroup of patients. We aimed to develop an efficient strategy to select candidates for ART in the first two weeks of head and neck cancer (HNC) radiotherapy. MATERIALS AND METHODS: This study retrospectively enrolled 110 HNC patients who underwent modern photon radiotherapy with at least 5 weekly in-treatment re-scan CTs. A semi auto-segmentation method was applied to obtain the weekly mean dose (Dmean) to OARs. A comprehensive NTCP-profile was applied to obtain NTCP's. The difference between planning and actual values of Dmean (ΔDmean) and dichotomized difference of clinical relevance (BIOΔNTCP) were used for modelling to determine the cut-off maximum ΔDmean of OARs in week 1 and 2 (maxΔDmean_1 and maxΔDmean_2). Four strategies to select candidates for ART, using cut-off maxΔDmean were compared. RESULTS: The Spearman's rank correlation test showed significant positive correlation between maxΔDmean and BIOΔNTCP (p-value <0.001). For major BIOΔNTCP (>5%) of acute and late toxicity, 10.9% and 4.5% of the patients were true candidates for ART. Strategy C using both cut-off maxΔDmean_1 (3.01 and 5.14 Gy) and cut-off maxΔDmean_2 (3.41 and 5.30 Gy) showed the best sensitivity, specificity, positive and negative predictive values (0.92, 0.82, 0.38, 0.99 for acute toxicity and 1.00, 0.92, 0.38, 1.00 for late toxicity, respectively). CONCLUSIONS: We propose an efficient selection strategy for ART that is able to classify the subgroup of patients with >5% BIOΔNTCP for late toxicity using imaging in the first two treatment weeks.


Subject(s)
Head and Neck Neoplasms , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Dosage , Retrospective Studies , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk , Head and Neck Neoplasms/radiotherapy
13.
Phys Med Biol ; 68(8)2023 04 03.
Article in English | MEDLINE | ID: mdl-36893469

ABSTRACT

Objective.Automatic segmentation of organs-at-risk in radiotherapy planning computed tomography (CT) scans using convolutional neural networks (CNNs) is an active research area. Very large datasets are usually required to train such CNN models. In radiotherapy, large, high-quality datasets are scarce and combining data from several sources can reduce the consistency of training segmentations. It is therefore important to understand the impact of training data quality on the performance of auto-segmentation models for radiotherapy.Approach.In this study, we took an existing 3D CNN architecture for head and neck CT auto-segmentation and compare the performance of models trained with a small, well-curated dataset (n= 34) and then a far larger dataset (n= 185) containing less consistent training segmentations. We performed 5-fold cross-validations in each dataset and tested segmentation performance using the 95th percentile Hausdorff distance and mean distance-to-agreement metrics. Finally, we validated the generalisability of our models with an external cohort of patient data (n= 12) with five expert annotators.Main results.The models trained with a large dataset were greatly outperformed by models (of identical architecture) trained with a smaller, but higher consistency set of training samples. Our models trained with a small dataset produce segmentations of similar accuracy as expert human observers and generalised well to new data, performing within inter-observer variation.Significance.We empirically demonstrate the importance of highly consistent training samples when training a 3D auto-segmentation model for use in radiotherapy. Crucially, it is the consistency of the training segmentations which had a greater impact on model performance rather than the size of the dataset used.


Subject(s)
Head , Image Processing, Computer-Assisted , Humans , Image Processing, Computer-Assisted/methods , Neck , Neural Networks, Computer , Tomography, X-Ray Computed
14.
Clin Transl Radiat Oncol ; 42: 100652, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37415639

ABSTRACT

Background and purpose: Previous pre-clinical research using [18F]FDG-PET has shown that whole-brain photon-based radiotherapy can affect brain glucose metabolism. This study, aimed to investigate how these findings translate into regional changes in brain [18F]FDG uptake in patients with head and neck cancer treated with intensity-modulated proton therapy (IMPT). Materials and methods: Twenty-three head and neck cancer patients treated with IMPT and available [18F]FDG scans before and at 3 months follow-up were retrospectively evaluated. Regional assessment of the [18F]FDG standardized uptake value (SUV) parameters and radiation dose in the left (L) and right (R) hippocampi, L and R occipital lobes, cerebellum, temporal lobe, L and R parietal lobes and frontal lobe were evaluated to understand the relationship between regional changes in SUV metrics and radiation dose. Results: Three months after IMPT, [18F]FDG brain uptake calculated using SUVmean and SUVmax, was significantly higher than that before IMPT. The absolute SUVmean after IMPT was significantly higher than before IMPT in seven regions of the brain (p ≤ 0.01), except for the R (p = 0.11) and L (p = 0.15) hippocampi. Absolute and relative changes were variably correlated with the regional maximum and mean doses received in most of the brain regions. Conclusion: Our findings suggest that 3 months after completion of IMPT for head and neck cancer, significant increases in the uptake of [18F]FDG (reflected by SUVmean and SUVmax) can be detected in several individual key brain regions, and when evaluated jointly, it shows a negative correlation with the mean dose. Future studies are needed to assess whether and how these results could be used for the early identification of patients at risk for adverse cognitive effects of radiation doses in non-tumor tissues.

15.
Phys Med Biol ; 67(11)2022 05 27.
Article in English | MEDLINE | ID: mdl-35561701

ABSTRACT

Objective.The output of a deep learning (DL) auto-segmentation application should be reviewed, corrected if needed and approved before being used clinically. This verification procedure is labour-intensive, time-consuming and user-dependent, which potentially leads to significant errors with impact on the overall treatment quality. Additionally, when the time needed to correct auto-segmentations approaches the time to delineate target and organs at risk from scratch, the usability of the DL model can be questioned. Therefore, an automated quality assurance framework was developed with the aim to detect in advance aberrant auto-segmentations.Approach. Five organs (prostate, bladder, anorectum, femoral head left and right) were auto-delineated on CT acquisitions for 48 prostate patients by an in-house trained primary DL model. An experienced radiation oncologist assessed the correctness of the model output and categorised the auto-segmentations into two classes whether minor or major adaptations were needed. Subsequently, an independent, secondary DL model was implemented to delineate the same structures as the primary model. Quantitative comparison metrics were calculated using both models' segmentations and used as input features for a machine learning classification model to predict the output quality of the primary model.Main results. For every organ, the approach of independent validation by the secondary model was able to detect primary auto-segmentations that needed major adaptation with high sensitivity (recall = 1) based on the calculated quantitative metrics. The surface DSC and APL were found to be the most indicated parameters in comparison to standard quantitative metrics for the time needed to adapt auto-segmentations.Significance. This proposed method includes a proof of concept for the use of an independent DL segmentation model in combination with a ML classifier to improve time saving during QA of auto-segmentations. The integration of such system into current automatic segmentation pipelines can increase the efficiency of the radiotherapy contouring workflow.


Subject(s)
Deep Learning , Organs at Risk , Algorithms , Humans , Image Processing, Computer-Assisted/methods , Machine Learning , Male , Organs at Risk/diagnostic imaging , Prostate , Radiotherapy Planning, Computer-Assisted/methods
16.
Semin Radiat Oncol ; 32(4): 421-431, 2022 10.
Article in English | MEDLINE | ID: mdl-36202444

ABSTRACT

Recent advancements in artificial intelligence (AI) in the domain of radiation therapy (RT) and their integration into modern software-based systems raise new challenges to the profession of medical physics experts. These AI algorithms are typically data-driven, may be continuously evolving, and their behavior has a degree of (acceptable) uncertainty due to inherent noise in training data and the substantial number of parameters that are used in the algorithms. These characteristics request adaptive, and new comprehensive quality assurance (QA) approaches to guarantee the individual patient treatment quality during AI algorithm development and subsequent deployment in a clinical RT environment. However, the QA for AI-based systems is an emerging area, which has not been intensively explored and requires interactive collaborations between medical doctors, medical physics experts, and commercial/research AI institutions. This article summarizes the current QA methodologies for AI modules of every subdomain in RT with further focus on persistent shortcomings and upcoming key challenges and perspectives.


Subject(s)
Algorithms , Artificial Intelligence , Humans
17.
Clin Transl Radiat Oncol ; 33: 99-105, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35198742

ABSTRACT

Aim: To investigate the clinical relevance of the radiotherapy (RT) dose bath in patients treated for lower grade glioma (LGG). Methods: Patients (n = 17) treated with RT for LGG were assessed with neurocognitive function (NCF) tests and structural Magnetic Resonance Imaging (MRI) and categorized in subgroups based on tumour lateralisation. RT dose, volumetric results and cerebral microbleed (CMB) number were extracted for contralateral cerebrum, contralateral hippocampus, and cerebellum. The RT clinical target volume (CTV) was included in the analysis as a surrogate for focal tumour and other treatment effects. The relationships between RT dose, CTV, NCF and radiological outcome were analysed per subgroup. Results: The subgroup with left-sided tumours (n = 10) performed significantly lower on verbal tests. The RT dose to the right cerebrum, as well as CTV, were related to poorer performance on tests for processing speed, attention, and visuospatial abilities, and more CMB.In the subgroup with right-sided tumours (n = 7), RT dose in the left cerebrum was related to lower verbal memory performance, (immediate and delayed recall, r = -0.821, p = 0.023 and r = -0.937, p = 0.002, respectively), and RT dose to the left hippocampus was related to hippocampal volume (r = -0.857, p = 0.014), without correlation between CTV and NCF. Conclusion: By using a novel approach, we were able to investigate the clinical relevance of the RT dose bath in patients with LGG more specifically. We used combined MRI-derived and NCF outcome measures to assess radiation-induced brain damage, and observed potential RT effects on the left-sided brain resulting in lower verbal memory performance and hippocampus volume.

19.
Radiother Oncol ; 154: 194-200, 2021 01.
Article in English | MEDLINE | ID: mdl-32956707

ABSTRACT

PURPOSE: Large-field photon radiotherapy is current standard in the treatment of cervical cancer patients. However, with the increasing availability of Pencil Beam Scanning Proton Therapy (PBS-PT) and robust treatment planning techniques, protons may have significant advantages for cervical cancer patients in the reduction of toxicity. In this study, PBS-PT and photon Volumetric Modulated Arc Therapy (VMAT) were compared, examining target coverage and organ at risk (OAR) dose, taking inter- and intra-fraction motion into account. MATERIALS AND METHODS: Twelve cervical cancer patients were included in this in-silico planning study. In all cases, a planning CT scan, five weekly repeat CT scans (reCTs) and an additional reCT 10 min after the first reCT were available. Two-arc VMAT and robustly optimised two- and four-field (2F and 4F) PBS-PT plans were robustly evaluated on planCTs and reCTs using set-up and range uncertainty. Nominal OAR doses and voxel-wise minimum target coverage robustness were compared. RESULTS: Average voxel-wise minimum accumulated doses for pelvic target structures over all patients were adequate for both photon and proton treatment techniques (D98 > 95%, [91.7-99.3%]). Average accumulated dose of the para-aortic region was lower than the required 95%, D98 > 94.4% [91.1-98.2%]. With PBS-PT 4F, dose to all OARs was significantly lower than with VMAT. Major differences were observed for mean bowel bag V15Gy: 60% [39-70%] for VMAT vs 30% [10-52%] and 32% [9-54%] for PBS-PT 2F and 4F and for mean bone marrow V10Gy: 88% [82-97%] for VMAT vs 66% [60-73%] and 67% [60-75%] for PBS-PT 2F and 4F. CONCLUSION: Robustly optimised PBS-PT for cervical cancer patients shows equivalent target robustness against inter- and intra-fraction variability compared to VMAT, and offers significantly better OAR sparing.


Subject(s)
Proton Therapy , Radiotherapy, Intensity-Modulated , Uterine Cervical Neoplasms , Female , Humans , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Uterine Cervical Neoplasms/radiotherapy
20.
Radiother Oncol ; 164: 167-174, 2021 11.
Article in English | MEDLINE | ID: mdl-34597740

ABSTRACT

BACKGROUND AND PURPOSE: Accurate segmentation of organs-at-risk (OARs) is crucial but tedious and time-consuming in adaptive radiotherapy (ART). The purpose of this work was to automate head and neck OAR-segmentation on repeat CT (rCT) by an optimal combination of human and auto-segmentation for accurate prediction of Normal Tissue Complication Probability (NTCP). MATERIALS AND METHODS: Human segmentation (HS) of 3 observers, deformable image registration (DIR) based contour propagation and deep learning contouring (DLC) were carried out to segment 15 OARs on 15 rCTs. The original treatment plan was re-calculated on rCT to obtain mean dose (Dmean) and consequent NTCP-predictions. The average Dmean and NTCP-predictions of the three observers were referred to as the gold standard to calculate the absolute difference of Dmean and NTCP-predictions (|ΔDmean| and |ΔNTCP|). RESULTS: The average |ΔDmean| of parotid glands in HS was 1.40 Gy, lower than that obtained with DIR and DLC (3.64 Gy, p < 0.001 and 3.72 Gy, p < 0.001, respectively). DLC showed the highest |ΔDmean| in middle Pharyngeal Constrictor Muscle (PCM) (5.13 Gy, p = 0.01). DIR showed second highest |ΔDmean| in the cricopharyngeal inlet (2.85 Gy, p = 0.01). The semi auto-segmentation (SAS) adopted HS, DIR and DLC for segmentation of parotid glands, PCM and all other OARs, respectively. The 90th percentile |ΔNTCP|was 2.19%, 2.24%, 1.10% and 1.50% for DIR, DLC, HS and SAS respectively. CONCLUSIONS: Human segmentation of the parotid glands remains necessary for accurate interpretation of mean dose and NTCP during ART. Proposed semi auto-segmentation allows NTCP-predictions within 1.5% accuracy for 90% of the cases.


Subject(s)
Head and Neck Neoplasms , Radiotherapy Planning, Computer-Assisted , Head , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/radiotherapy , Humans , Organs at Risk , Probability , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL