Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Eur Heart J ; 45(3): 198-210, 2024 Jan 14.
Article in English | MEDLINE | ID: mdl-37874971

ABSTRACT

BACKGROUND AND AIMS: Transcatheter pulmonary valve implantation (TPVI) is indicated to treat right-ventricular outflow tract (RVOT) dysfunction related to congenital heart disease (CHD). Outcomes of TPVI with the SAPIEN 3 valve that are insufficiently documented were investigated in the EUROPULMS3 registry of SAPIEN 3-TPVI. METHODS: Patient-related, procedural, and follow-up outcome data were retrospectively assessed in this observational cohort from 35 centres in 15 countries. RESULTS: Data for 840 consecutive patients treated in 2014-2021 at a median age of 29.2 (19.0-41.6) years were obtained. The most common diagnosis was conotruncal defect (70.5%), with a native or patched RVOT in 50.7% of all patients. Valve sizes were 20, 23, 26, and 29 mm in 0.4%, 25.5%, 32.1%, and 42.0% of patients, respectively. Valve implantation was successful in 98.5% [95% confidence interval (CI), 97.4%-99.2%] of patients. Median follow-up was 20.3 (7.1-38.4) months. Eight patients experienced infective endocarditis; 11 required pulmonary valve replacement, with a lower incidence for larger valves (P = .009), and four experienced pulmonary valve thrombosis, including one who died and three who recovered with anticoagulation. Cumulative incidences (95%CI) 1, 3, and 6 years after TPVI were as follows: infective endocarditis, 0.5% (0.0%-1.0%), 0.9% (0.2%-1.6%), and 3.8% (0.0%-8.4%); pulmonary valve replacement, 0.4% (0.0%-0.8%), 1.3% (0.2%-2.4%), and 8.0% (1.2%-14.8%); and pulmonary valve thrombosis, 0.4% (0.0%-0.9%), 0.7% (0.0%-1.3%), and 0.7% (0.0%-1.3%), respectively. CONCLUSIONS: Outcomes of SAPIEN 3 TPVI were favourable in patients with CHD, half of whom had native or patched RVOTs.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Heart Defects, Congenital , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Thrombosis , Adult , Humans , Cardiac Catheterization/adverse effects , Endocarditis/epidemiology , Endocarditis, Bacterial/complications , Heart Defects, Congenital/complications , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Prosthesis Design , Pulmonary Valve/surgery , Pulmonary Valve Insufficiency/epidemiology , Pulmonary Valve Insufficiency/surgery , Registries , Retrospective Studies , Thrombosis/etiology , Treatment Outcome
2.
Catheter Cardiovasc Interv ; 92(5): 925-929, 2018 11 01.
Article in English | MEDLINE | ID: mdl-28895301

ABSTRACT

A 59-year-old female with Tetralogy of Fallot had a previous complete repair with RVOT patch enlargement. She developed subsequent severe symptomatic (NYHA III) pulmonary regurgitation with severe RV dilatation. She had a concomitant interstitial lung disease secondary to hypersensitivity pneumonitis that precluded her from cardiac surgery. After preprocedural assessment using computed tomography, echocardiography and invasive angiography we decided to implant a 29 mm Edwards Sapien 3 valve without pre-stenting. The Sapien 3 valve was implanted in a satisfactory position using rapid RV pacing. The valve appeared well expanded with good circularity on fluoroscopy. A transthoracic echocardiography on the following day showed no pulmonary regurgitation with a peak gradient of 14 mmHg across the prosthesis. At 4 weeks follow-up, the patient felt a marked improvement (NYHA II) but a CT scan showed bileaflet valve thickening with preserved stent expansion. A concomitant echo-doppler showed a significant increase of peak pulmonary gradient to 26 mmHg. After a six weeks course of warfarin therapy, the transpulmonary valve peak gradient came down to 16 mmHg and leaflet thickening resolved on CT. The Sapien 3 system helped achieve a successful transfemoral percutaneous pulmonary valve implantation in a challenging native RVOT anatomy. This case was complicated by early valve thrombosis as documented by CT and was successfully treated with oral anticoagulation.


Subject(s)
Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve/surgery , Thrombosis/etiology , Aged , Female , Humans , Prosthesis Design , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/physiopathology , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/physiopathology , Thrombosis/diagnostic imaging , Time Factors , Treatment Outcome
3.
Circulation ; 121(16): 1848-57, 2010 Apr 27.
Article in English | MEDLINE | ID: mdl-20385927

ABSTRACT

BACKGROUND: The majority of prosthetic heart valves currently implanted are tissue valves that can be expected to degenerate with time and eventually fail. Repeat cardiac surgery to replace these valves is associated with significant morbidity and mortality. Transcatheter heart valve implantation within a failed bioprosthesis, a "valve-in-valve" procedure, may offer a less invasive alternative. METHODS AND RESULTS: Valve-in-valve implantations were performed in 24 high-risk patients. Failed valves were aortic (n=10), mitral (n=7), pulmonary (n=6), or tricuspid (n=1) bioprostheses. Implantation was successful with immediate restoration of satisfactory valve function in all but 1 patient. No patient had more than mild regurgitation after implantation. No patients died during the procedure. Thirty-day mortality was 4.2%. Mortality was related primarily to learning-curve issues early in this high-risk experience. At baseline, 88% of patients were in New York Heart Association functional class III or IV; at the last follow-up, 88% of patients were in class I or II. At a median follow-up of 135 days (interquartile range, 46 to 254 days) and a maximum follow-up of 1045 days, 91.7% of patients remained alive with satisfactory valve function. CONCLUSIONS: Transcatheter valve-in-valve implantation is a reproducible option for the management of bioprosthetic valve failure. Aortic, pulmonary, mitral, and tricuspid tissue valves were amenable to this approach. This finding may have important implications with regard to valve replacement in high-risk patients.


Subject(s)
Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Mitral Valve Insufficiency/surgery , Postoperative Complications/surgery , Prosthesis Failure , Reoperation , Adult , Aged , Aged, 80 and over , Comorbidity , Fluoroscopy , Follow-Up Studies , Heart Valve Prosthesis Implantation/mortality , Humans , Middle Aged , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Postoperative Complications/mortality , Prosthesis Design , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/mortality , Pulmonary Valve Insufficiency/surgery , Reoperation/mortality , Risk Factors , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/mortality , Tricuspid Valve Insufficiency/surgery
4.
Am Heart J ; 159(5): 876-81, 2010 May.
Article in English | MEDLINE | ID: mdl-20435199

ABSTRACT

BACKGROUND: Blood transfusion has been associated with an increased mortality in patients undergoing percutaneous coronary intervention (PCI). Although the reasons for this remain unclear, it may be related to the structural and functional changes occurring within red blood cells (RBCs) during storage. We investigated whether RBC storage duration was associated with mortality in patients requiring transfusion after PCI. METHODS: We collected data on all RBC transfusions occurring within 10 days of PCI (excluding those related to cardiac surgery) using the British Columbia Cardiac Registry and Central Transfusion Registry. Transfusion details were analyzed according to 30-day survival. RESULTS: From a total of 32,580 patients undergoing PCI, 909 (2.8%) patients received RBCs with a mean storage duration of 25 +/- 10 days. In these 909 patients, mean transfusion volumes were lower in survivors (2.8 +/- 2.1 vs 3.8 +/- 2.9 U, P = .002) than those who died within 30 days. In a multivariate analysis to adjust for baseline risk, mean RBC storage age (HR 1.02 [95% CI 1.01-1.04], P = .002) and transfusion volume (HR 1.26 [95% CI 1.18-1.34], P < .001) both predicted 30-day mortality. Transfused patients who received only older blood (RBC min age >28 days) appeared to be at greater risk of death (HR 2.49 [95% CI 1.45-4.25], P = .001). CONCLUSION: Red blood cell transfusion is associated with increased 30-day mortality in patients undergoing PCI. Although current transfusion practice permits RBC storage for up to 42 days, the use of older red cells may pose an additional hazard to this patient group.


Subject(s)
Angioplasty, Balloon, Coronary/mortality , Blood Preservation , Erythrocyte Transfusion/adverse effects , Erythrocytes , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Multivariate Analysis , Proportional Hazards Models , Time Factors
5.
Catheter Cardiovasc Interv ; 75(2): 295-300, 2010 Feb 01.
Article in English | MEDLINE | ID: mdl-19885917

ABSTRACT

OBJECTIVES: Transcatheter valve and valve delivery systems are undergoing rapid evolution. We describe the current generation balloon-expandable valve and delivery systems. BACKGROUND AND METHODS: The SAPIEN XT valve represents the newest generation balloon-expandable aortic bioprosthesis. A cobalt-chromium alloy frame and additional design modifications facilitate a reduction in delivery profile while maintaining structural integrity, hemodynamics, and durability. The RetroFlex 3 delivery system represents the latest clinically available delivery system. It incorporates a fixed, tapered, and deflecting crossing tip to facilitate atraumatic introduction and a rapid inflation lumen to reduce valve motion during deployment. The NovaFlex delivery system represents the next generation delivery catheter. When used in conjunction with the SAPIEN XT valve and a specially constructed introducer sheath the inner and the outer diameters are 18 and 21 F, respectively. RESULTS: The RetroFlex 3 delivery system was utilized in nine patients and the NovaFlex delivery system in four. The valve implanted was the SAPIEN in six and the SAPIEN XT valve in seven. Implantation was successful in all patients. A reduction in device movement during balloon deployment was apparent as compared with earlier delivery systems. Aortic mean gradient fell from 45.6 (+/-15.1) mm Hg to 13.2 (+/-5.1) mm Hg, valve area rose from 0.68 (+/-0.19) to 1.5 (+/-0.28) cm(2). No patient had more than mild paravalvular regurgitation. CONCLUSION: Transcatheter valves and delivery systems continue to improve in terms of profile and ease of use.


Subject(s)
Aortic Valve Stenosis/therapy , Bioprosthesis , Catheterization/instrumentation , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Catheterization/adverse effects , Female , Heart Valve Prosthesis Implantation/adverse effects , Hemodynamics , Humans , Male , Prosthesis Design , Radiography , Severity of Illness Index , Treatment Outcome
6.
Catheter Cardiovasc Interv ; 76(7): 1035-40, 2010 Dec 01.
Article in English | MEDLINE | ID: mdl-20506193

ABSTRACT

OBJECTIVES: Endovascular stenting of aneurysms late after surgical repair of coarctation may have to deal with marked changes in aortic diameter proximal and distal to the aneurysm. We report our first-in-man successful use of a custom-made tapered (variable diameter) covered stent. METHODS: The aneurysm was 42 mm in diameter with a length of 40 mm. On MRI, the aorta measured 19.6 mm proximal and 13.3 mm distal to the aneurysm. The aim was to oversize the stent by 10-20%. A covered Cheatham-platinum stent was designed so that cranial portion of the stent would expand to 22 mm and the caudal portion to 15 mm with a length of 8.5 cm when fully inflated. The stent was mounted on a balloon-in-balloon delivery system and was delivered through an 18 F femoral arterial sheath. Rapid-pacing technique was used for deployment. RESULTS: The stent was successfully deployed without complications. After deployment, the stent diameter measured 21.2 mm cranially and 15.6 mm caudally. A mild distal endoleak due to inadequate fixation of the stent graft was resolved by post dilation expanding the stent diameter to 22.1 mm and 15.9 mm, respectively. The femoral access site was closed using two percutaneous closure devices and the patient discharged the day after the procedure. Follow-up CT-angiography showed continued successful exclusion of the aneurysm. CONCLUSIONS: A new custom-made balloon expandable covered stent-design enabled successful treatment of an aortic aneurysm. This design may offer greater potential for more favorable initial angiographic results and potentially long-term outcomes due to superior apposition to the aortic wall.


Subject(s)
Angioplasty, Balloon/instrumentation , Aortic Aneurysm/therapy , Aortic Coarctation/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Cardiac Surgical Procedures/adverse effects , Stents , Adult , Angioplasty, Balloon/adverse effects , Aortic Aneurysm/diagnosis , Aortic Aneurysm/etiology , Aortography , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Female , Humans , Magnetic Resonance Angiography , Prosthesis Design , Radiography, Interventional , Tomography, X-Ray Computed , Treatment Outcome
7.
Am Heart J ; 158(3): 408-15, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19699864

ABSTRACT

BACKGROUND: The Occluded Artery Trial (OAT) was a 2,201-patient randomized clinical trial comparing routine stent-based percutaneous coronary intervention (PCI) versus optimal medical therapy alone in stable myocardial infarction (MI) survivors with persistent infarct-related artery occlusion identified day 3 to 28 post MI. Intent-to-treat analysis showed no difference between strategies with respect to the incidence of new class IV congestive heart failure, MI, or death. The influence of PCI failure, procedural hazard, and crossover on trial results has not been reported. METHODS: Study angiograms were analyzed and adjudicated centrally. Factors associated with PCI failure were examined. Time-to-event analysis using the OAT primary outcome was performed by PCI success status. Landmark analysis (up to and beyond 30 days) partitioned early hazard versus late outcome according to treatment received. RESULTS: Percutaneous coronary intervention was adjudicated successful in >87%. Percutaneous coronary intervention failure rates were similar in US and non-US sites, and did not significantly influence outcome at 60 months (hazard ratio for success vs fail 0.79, 99% CI 0.45-1.40, P = .29). Partitioning of early procedural hazard revealed no late benefit for PCI (hazard ratio for PCI success vs medical therapy alone 1.06, 99% CI 0.75-1.50, P = .66). CONCLUSIONS: Percutaneous coronary intervention failure and complication rates in the OAT were low. Neither PCI failure nor early procedural hazard substantively influenced the primary trial results.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Occlusion/therapy , Myocardial Infarction/therapy , Aged , Angioplasty, Balloon, Coronary/adverse effects , Cardiovascular Agents/therapeutic use , Clinical Protocols , Cohort Studies , Coronary Angiography , Coronary Occlusion/complications , Coronary Occlusion/diagnostic imaging , Female , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Treatment Outcome
8.
Catheter Cardiovasc Interv ; 73(6): 771-9, 2009 May 01.
Article in English | MEDLINE | ID: mdl-19309733

ABSTRACT

BACKGROUND: The majority of patients randomized to percutaneous coronary intervention (PCI) in the Occluded Artery Trial (OAT) and its angiographic substudy, the Total Occlusion Study of Canada 2 (TOSCA-2) were treated with bare metal stents (BMS). We aimed to determine if stenting of the target occlusion in OAT with drug-eluting stents (DES) was associated with more favorable angiographic results and clinical outcome when compared with treatment with BMS. METHODS: TOSCA-2 DES was a prospective nonrandomized substudy that provided 1-year angiographic comparison of late loss and reocclusion in 25 patients treated with DES and in 128 treated with BMS. In addition, all PCI-assigned patients enrolled from the time when DES were first utilized were similarly categorized (DES n = 77, and BMS n = 386) and compared using the 3-year cumulative OAT primary combined endpoint of death, myocardial infarction, or Class-IV heart failure, as well as angina. RESULTS: In-segment late loss was 0.14 +/- 0.45 mm for DES and 0.75 +/- 0.86 mm for BMS (P < 0.001). Corresponding binary restenosis rates were 13.0% and 44.3% (P = 0.005). Occlusion at 1 year was observed in 4.0 and 12.1%, respectively (P = 0.23). The 3-year cumulative primary event rate was 13.8% with DES and 12.5% with BMS (hazard ratio 1.08, 99% confidence intervals 0.44, 2.64; P = 0.83). Angina over time occurred less frequently in the DES group (P = 0.01). CONCLUSIONS: Although the reduction of late loss and trend to reduction in reocclusion with the use of DES for PCI of persistently occluded IRA 3-28 days post myocardial infarction did not translate into a signal for reduction in death, reinfarction, or Class IV heart failure, DES use was associated with less angina over time. Further follow-up is warranted.


Subject(s)
Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/instrumentation , Coronary Angiography , Coronary Occlusion/therapy , Coronary Restenosis/etiology , Drug-Eluting Stents , Metals , Stents , Adult , Aged , Angina Pectoris/etiology , Angioplasty, Balloon, Coronary/mortality , Canada , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/mortality , Coronary Occlusion/physiopathology , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/mortality , Coronary Restenosis/physiopathology , Female , Heart Failure/etiology , Humans , Kaplan-Meier Estimate , Logistic Models , Male , Middle Aged , Myocardial Infarction/etiology , Platelet Aggregation Inhibitors/therapeutic use , Prospective Studies , Prosthesis Design , Risk Assessment , Stroke Volume , Time Factors , Treatment Outcome , Ventricular Function, Left
9.
Swiss Med Wkly ; 139(31-32): 458-62, 2009 Aug 08.
Article in English | MEDLINE | ID: mdl-19685352

ABSTRACT

PRINCIPLES: Transfemoral aortic valve implantation (TAVI) is a promising treatment modality for selected patients with severe symptomatic aortic stenosis. Peripheral access via the femoral and iliac artery is an important issue, limiting this technique's applicability in patients suffering from peripheral arterial disease. Multislice computed tomography (MSCT) reliably identifies patients with suitable peripheral access. However, MSCT involves an additional contrast dye burden in patients often suffering from renal failure. In this study, the feasibility of direct-aortic-contrast-injection for MSCT was investigated, aiming to reduce total contrast load. METHODS: Patients undergoing evaluation for TAVI underwent an aortogram including iliac and femoral arteries. In 7 selected patients with questionable peripheral access, MSCT was performed by advancing a pigtail catheter to the level of L2, followed by direct injection of 15-20 ml of contrast mixed with an equal volume of saline. This injection was followed by an injection of 40 ml of saline. Scanning was initiated 4 seconds after starting the contrast injection. All MSCT scans were obtained using a 64 slice scanner. RESULTS: In all 7 patients, except one, the distal aorta, iliac and femoral arteries where adequately imaged to allow reliable assessment of peripheral access for TAVI. Of the 7 patients evaluated, 2 were rejected for TAVI based on the information of the MSCT using direct-aortic-contrast-injection. Limitations of the technique may be an underestimation of the arterial diameter due to spasms at the puncture site. CONCLUSION: MSCT using direct-aortic-contrast-injection for assessment of peripheral access for TAVI is feasible and may provide good diagnostic images with a reduced volume of contrast.


Subject(s)
Aortic Valve/surgery , Contrast Media/administration & dosage , Femoral Artery/diagnostic imaging , Heart Valve Prosthesis Implantation , Iliac Artery/diagnostic imaging , Tomography, X-Ray Computed , Aged , Aorta , Catheterization, Peripheral , Contrast Media/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Injections, Intra-Arterial , Kidney Diseases/chemically induced , Male , Triiodobenzoic Acids/administration & dosage , Triiodobenzoic Acids/adverse effects , Vascular Patency
10.
Circulation ; 116(7): 755-63, 2007 Aug 14.
Article in English | MEDLINE | ID: mdl-17646579

ABSTRACT

BACKGROUND: Percutaneous aortic valve replacement represents an endovascular alternative to conventional open heart surgery without the need for sternotomy, aortotomy, or cardiopulmonary bypass. METHODS AND RESULTS: Transcatheter implantation of a balloon-expandable stent valve using a femoral arterial approach was attempted in 50 symptomatic patients with severe aortic stenosis in whom there was a consensus that the risks of conventional open heart surgery were very high. Valve implantation was successful in 86% of patients. Intraprocedural mortality was 2%. Discharge home occurred at a median of 5 days (interquartile range, 4 to 13). Mortality at 30 days was 12% in patients in whom the logistic European System for Cardiac Operative Risk Evaluation risk score was 28%. With experience, procedural success increased from 76% in the first 25 patients to 96% in the second 25 (P=0.10), and 30-day mortality fell from 16% to 8% (P=0.67). Successful valve replacement was associated with an increase in echocardiographic valve area from 0.6+/-0.2 to 1.7+/-0.4 cm2. Mild paravalvular regurgitation was common but was well tolerated. After valve insertion, there was a significant improvement in left ventricular ejection fraction (P<0.0001), mitral regurgitation (P=0.01), and functional class (P<0.0001). Improvement was maintained at 1 year. Structural valve deterioration was not observed with a median follow-up of 359 days. CONCLUSIONS: Percutaneous valve replacement may be an alternative to conventional open heart surgery in selected high-risk patients with severe symptomatic aortic stenosis.


Subject(s)
Aortic Valve Stenosis/therapy , Aortic Valve , Catheterization , Heart Valve Prosthesis , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/diagnostic imaging , Female , Follow-Up Studies , Humans , Male , Middle Aged , Treatment Outcome , Ultrasonography
11.
Am Heart J ; 155(2): 375-81, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18215611

ABSTRACT

BACKGROUND: Several studies have demonstrated that women with nonobstructive coronary disease have a high rate of subsequent investigations, rehospitalizations for recurrent chest pain, and repeat coronary angiography. The sex specificity of this finding is unclear. We therefore undertook an evaluation of sex differences in rehospitalization for acute coronary syndrome (ACS) or chest pain in patients with "angiographically normal" coronaries. METHODS: A retrospective cohort study using prospectively collected angiographic and clinical data on all patients in British Columbia, Canada, presenting for their first cardiac catheterization with suspected ischemic heart disease but angiographically normal coronaries. RESULTS: Among 32,856 patients, 7.1% of men versus 23.3% of women were angiographically normal (P < .001). Among angiographically normal patients, women were older and more likely to present with hypertension, prior stroke, chronic obstructive pulmonary disease, and peripheral vascular disease than men, but Canadian Cardiovascular Society class of angina did not vary by sex. Within 1 year, 1.0% died, (19 women, 18 men, P = .27) and 0.6% had a stroke (13 women, 9 men, P = .91). Readmission to hospital for ACS or chest pain requiring catheterization was significantly higher in women compared to men (adjusted OR 4.06; 95% CI 1.15-14.31). CONCLUSIONS: In a contemporary, population-based cohort presenting for cardiac catheterization for suspected ischemia, women with angiographically normal coronaries were >4 times more likely to be readmitted to hospital for ACS/chest pain within 180 days compared to men. The observed sex difference has important social and economic implications and suggests that traditional diagnostic methods may not be optimal for women.


Subject(s)
Acute Coronary Syndrome/diagnostic imaging , Angina Pectoris/diagnostic imaging , Coronary Angiography , Aged , Cohort Studies , Coronary Vessels , Female , Hospitalization , Humans , Male , Middle Aged , Outcome Assessment, Health Care , Recurrence , Registries , Retrospective Studies , Sex Factors
12.
Catheter Cardiovasc Interv ; 72(4): 573-8, 2008 Oct 01.
Article in English | MEDLINE | ID: mdl-18819120

ABSTRACT

OBJECTIVES: Early clinical outcomes in selected high-risk patients undergoing catheter-based aortic valve replacement (AVR) compare favorably with conventional surgical AVR. Improved understanding of the mechanisms of success and failure of transcatheter AVR will likely improve outcomes further. To this end, we examined our experience during the developmental phases of transcatheter AVR and describe the causes and management of prosthetic valve malposition. METHODS: Transcatheter balloon-expandable AVR was performed in 170 patients at two centers. Malposition was defined as prosthetic valve implantation in a location other than within the native valve. Patients were prospectively identified and followed as part of an ongoing database. RESULTS: Valve malposition occurred in 9 of 170 patients (5.3%). Final position was supravalvular in eight of nine cases. In all cases, embolization to the ascending aorta occurred within a few cardiac cycles following deployment. Importantly, late embolization was not observed. In most cases, the prosthesis was uneventfully repositioned in the more distal aorta. Positioning was subvalvular in one patient (0.6%), resulting in a severe regurgitation with residual native valve stenosis. Implantation of a second transcatheter valve was attempted in six patients and was successful in all. Conventional AVR was performed in two patients, with early mortality in one. At late follow-up (mean 412 days), seven of nine patients remain alive (78%) with a functioning prosthesis and relief of aortic stenosis. CONCLUSIONS: Malposition of current balloon-expandable aortic valves is a largely preventable complication. An improved understanding of the procedure will likely minimize this possibility and mitigate the consequences should malposition occur.


Subject(s)
Aortic Valve Stenosis/therapy , Aortic Valve , Cardiac Catheterization/adverse effects , Catheterization/adverse effects , Foreign-Body Migration/therapy , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Canada , Cardiac Catheterization/instrumentation , Catheterization/instrumentation , Device Removal , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Foreign-Body Migration/mortality , Foreign-Body Migration/prevention & control , Heart Valve Prosthesis Implantation/instrumentation , Humans , Prospective Studies , Prosthesis Design , Prosthesis Failure , Radiography, Interventional , Time Factors , Treatment Outcome
13.
Circulation ; 114(6): 591-6, 2006 Aug 08.
Article in English | MEDLINE | ID: mdl-16880325

ABSTRACT

BACKGROUND: Aortic valve replacement with cardiopulmonary bypass is currently the treatment of choice for symptomatic aortic stenosis but carries a significant risk of morbidity and mortality, particularly in patients with comorbidities. Recently, percutaneous transfemoral aortic valve implantation has been proposed as a viable alternative in selected patients. We describe our experience with a new, minimally invasive, catheter-based approach to aortic valve implantation via left ventricular apical puncture without cardiopulmonary bypass or sternotomy. METHODS AND RESULTS: A left anterolateral intercostal incision is used to expose the left ventricular apex. Direct needle puncture of the apex allows introduction of a hemostatic sheath into the left ventricle. The valve prosthesis, constructed from a stainless steel stent with an attached trileaflet equine pericardial valve, is crimped onto a valvuloplasty balloon. The prosthetic valve and balloon catheter are passed over a wire into the left ventricle. Positioning within the aortic annulus is confirmed by fluoroscopy, aortography, and echocardiography. Rapid ventricular pacing is used to reduce cardiac output while the balloon is inflated, deploying the prosthesis within the annulus. Transapical aortic valve implantation was successfully performed in 7 patients in whom surgical risk was deemed excessive because of comorbidities. Echocardiographic median aortic valve area increased from 0.7 +/- 0.1 cm2 (interquartile range) to 1.8 +/- 0.8 cm2 (interquartile range). There were no intraprocedural deaths. At a follow up of 87 +/- 56 days, 6 of 7 patients remain alive and well. CONCLUSIONS: This initial experience suggests that transapical aortic valve implantation without cardiopulmonary bypass is feasible in selected patients with aortic stenosis.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Thoracic Surgery/methods , Age Factors , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve Stenosis/physiopathology , Catheterization/instrumentation , Echocardiography, Transesophageal , Female , Heart Valve Prosthesis Implantation/instrumentation , Heart Ventricles/surgery , Humans , Male , Middle Aged , Minimally Invasive Surgical Procedures/methods , Prognosis , Risk Factors , Thoracic Surgery/instrumentation , Treatment Outcome
14.
Circulation ; 113(6): 842-50, 2006 Feb 14.
Article in English | MEDLINE | ID: mdl-16461813

ABSTRACT

BACKGROUND: Percutaneous aortic valve implantation by an antegrade transvenous approach has been described but is problematic. Retrograde prosthetic aortic valve implantation via the femoral artery has potential advantages. Percutaneous prosthetic aortic valve implantation via the femoral arterial approach is described and the initial experience reported. METHODS AND RESULTS: The valve prosthesis is constructed from a stainless steel stent with an attached trileaflet equine pericardial valve and a fabric cuff. After routine aortic balloon valvuloplasty, a 22F or 24F sheath is advanced from the femoral artery to the aorta. A steerable, deflectable catheter facilitates manipulation of the prosthesis around the aortic arch and through the stenotic valve. Rapid ventricular pacing is used to reduce cardiac output while the delivery balloon is inflated to deploy the prosthesis within the annulus. Percutaneous aortic prosthetic valve implantation was attempted in 18 patients (aged 81+/-6 years) in whom surgical risk was deemed excessive because of comorbidities. Iliac arterial injury, seen in the first 2 patients, did not recur after improvement in screening and access site management. Implantation was successful in 14 patients. After successful implantation, the aortic valve area increased from 0.6+/-0.2 to 1.6+/-0.4 cm2. There were no intraprocedural deaths. At follow-up of 75+/-55 days, 16 patients (89%) remained alive. CONCLUSIONS: This initial experience suggests that percutaneous transarterial aortic valve implantation is feasible in selected high-risk patients with satisfactory short-term outcomes.


Subject(s)
Aortic Valve , Heart Valve Prosthesis Implantation/methods , Aged , Aged, 80 and over , Animals , Bioprosthesis , Catheterization/instrumentation , Equipment Design , Female , Femoral Artery , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/instrumentation , Horses , Humans , Male , Treatment Outcome
15.
Eur J Cardiothorac Surg ; 31(1): 16-21, 2007 Jan.
Article in English | MEDLINE | ID: mdl-17126558

ABSTRACT

BACKGROUND: The current treatment of choice for symptomatic aortic stenosis is aortic valve replacement (AVR) with cardiopulmonary bypass (CPB), but AVR is associated with significant operative morbidity and mortality in elderly patients with multiple co-morbid conditions. We recently reported the first successful aortic valve implantation procedure (AVI) via a mini-thoracotomy and left ventricular apical puncture without cardiopulmonary bypass. We now report 6-month follow-up in our initial seven patients. METHODS: Seven patients (77+/-10 years old) with symptomatic aortic stenosis were deemed to be non-surgical candidates for AVR and not suitable for a transfemoral percutaneous heart valve implantation due to aorto-iliac disease. The predicted 30-day operative mortality was 31+/-23% according to logistic Euroscore. Patients underwent minimally invasive transapical AVI. With the guidance of fluoroscopy and transesophageal echocardiography, balloon predilation was followed by deployment of a 26mm Cribier-Edwardstrade mark valve (Edwards Lifesciences Inc., Irvine, CA) during rapid ventricular pacing to reduce forward flow and cardiac motion. RESULTS: Valve implantation was successful in all seven patients. There were no intra-procedural mortalities or complications. Thirty-day operative mortality was 14%. One patient died at day 12 due to pneumonia. Two patients died from non-cardiac diseases at day 51 and 85. The remaining four patients completed 6-month follow-up. The aortic valve area increased from 0.7+/-0.3 to 1.8+/-0.7 and 1.5+/-0.5cm(2) at 1 and 6 months, respectively. The mean transaortic gradient was reduced from 32+/-8 to 10+/-5 and 11+/-8mmHg at 1 and 6 months, respectively. Following AVI, none or trivial, mild, and moderate aortic regurgitation was observed in 4, 2, and 1 patients, respectively. There were no valve-related complications during the follow-up. CONCLUSION: Aortic valve implantation can successfully be performed via a minimally invasive apical approach without the need for cardiopulmonary bypass. The early results in this initial series are encouraging. This initial experience suggests that the minimally invasive transapical approach is a viable alternative for patients in whom open-heart surgery is not feasible or poses unacceptable risks.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Minimally Invasive Surgical Procedures/methods , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortography , Cardiopulmonary Bypass , Contraindications , Echocardiography, Transesophageal , Female , Follow-Up Studies , Heart Valve Prosthesis , Humans , Male , Middle Aged , Prosthesis Design , Treatment Outcome
16.
Am Heart J ; 151(2): 529.e1-529.e6, 2006 Feb.
Article in English | MEDLINE | ID: mdl-16442926

ABSTRACT

BACKGROUND: Myocardial ischemia is one of several potential causes of increased QT dispersion (QTd) in patients with nonacute total coronary artery occlusions (TCOs). We sought to assess the effect of percutaneous revascularization (PCI) of TCO on QTd and the relationship between QTd and long-term vessel patency. METHODS: Seventy patients enrolled in the TOSCA were analyzed. Patients were undergoing PCI of a TCO > 72 hours' duration. Two independent reviewers measured QTd from electrocardiograms done immediately before PCI (PRE), 12 to 18 hours after PCI (POST), and then at 6 months (6M). Follow-up angiography was performed at 6 months. RESULTS: Mean QTd decreased from PRE (77 +/- 29 milliseconds) to POST (66 +/- 26 milliseconds, P < .001) and 6M (65 +/- 25 milliseconds, P < .001). Patients with the same or longer QTd at 6 months compared with POST (POST < or = 6M) had significantly higher risk of failed target-vessel patency (odds ratio 10.3, 95% CI 1.24-84.8) than patients with QTd reduction at 6M versus POST values. CONCLUSION: Revascularization of TCO resulted in a decrease in QTd, which was sustained at 6M. This suggests that PCI to a TCO has a beneficial effect on stabilization of the underlying ischemic substrate. Furthermore, absence of QTd reduction at 6M versus POST was associated with increased risk of failed target-vessel patency.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Disease/physiopathology , Coronary Disease/therapy , Coronary Angiography , Coronary Disease/diagnostic imaging , Electrocardiography , Humans , Middle Aged , Myocardial Infarction/physiopathology , Time Factors
17.
Can J Cardiol ; 22(14): 1197-203, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17151768

ABSTRACT

OBJECTIVES: To examine outcomes following all first coronary revascularization procedures, isolated coronary artery bypass graft surgery (CABG) and percutaneous coronary intervention (PCI) on British Columbia (BC) resident adults from 1995 to 2001. METHODS: CABG and PCI data were obtained from the BC Cardiac Registry, and mortality data were obtained from the BC Vital Statistics Agency. Analysis was performed by annual cohorts, and the rates reported are unadjusted. RESULTS: An increasing percentage of revascularization procedures was performed with PCI (62% in 1995 to 73% in 2001; P<0.001) due to the increased use of PCI procedures. Except in emergent cases, 30-day mortality improved after PCI (1.8% to 1.1%; P=0.02) and CABG (1.8% to 1.2%; P=0.01). Emergent cases accounted for 9.0% of PCIs and 2.7% of CABGs, the percentage treated by CABG decreasing from 14.5% in 1995 to 7.5% by 2001 (P<0.001). Mortality rates among emergent cases was higher at 30 days, with no trend in PCI mortality (12%) but a substantial reduction in 30-day mortality after CABG (28% to 10%; P=0.003). One-year survival free from repeat revascularization following PCI increased from 73% in 1995 to 83% in 2001 (P<0.001) and from 94% to 95% (P<0.005) following CABG. CONCLUSIONS: Improvements in procedure-related mortality observed in trials have extended to clinical practice. With respect to emergent cases, an increasing proportion were treated by PCI with no change in PCI mortality but associated with a drop in surgical mortality. There has been a consistent and substantial drop in the need for repeat procedures within one year for patients selected for PCI.


Subject(s)
Angioplasty, Balloon, Coronary/statistics & numerical data , Coronary Artery Bypass/statistics & numerical data , Coronary Artery Disease/therapy , Adult , Age Distribution , Aged , Aged, 80 and over , Angioplasty, Balloon, Coronary/mortality , British Columbia/epidemiology , Coronary Artery Bypass/mortality , Coronary Artery Disease/mortality , Female , Humans , Male , Middle Aged , Prospective Studies , Registries , Sex Distribution
18.
PLoS One ; 11(10): e0164315, 2016.
Article in English | MEDLINE | ID: mdl-27711184

ABSTRACT

BACKGROUND: Markers of plaque destabilization and disruption may have a role in identifying non-STE- type 1 Myocardial Infarction in patients presenting with troponin elevation. We hypothesized that a plaque disruption index (PDI) derived from multiple biomarkers and measured within 24 hours from the first detectable troponin in patients with acute non-STE- type 1 MI (NSTEMI-A) will confirm the diagnosis and identify these patients with higher specificity when compared to individual markers and coronary angiography. METHODS: We examined 4 biomarkers of plaque destabilization and disruption: myeloperoxidase (MPO), high-sensitivity interleukin-6, myeloid-related protein 8/14 (MRP8/14) and pregnancy-associated plasma protein-A (PAPP-A) in 83 consecutive patients in 4 groups: stable non-obstructive coronary artery disease (CAD), stable obstructive CAD, NSTEMI-A (enrolled within 24 hours of troponin positivity), and NSTEMI-L (Late presentation NSTEMI, enrolled beyond the 24 hour limit). The PDI was calculated and the patients' coronary angiograms were reviewed for evidence of plaque disruption. The diagnostic performance of the PDI and angiography were compared. RESULTS: Compared to other biomarkers, MPO had the highest specificity (83%) for NSTEMI-A diagnosis (P<0.05). The PDI computed from PAPP-A, MRP8/14 and MPO was higher in NSTEMI-A patients compared to the other three groups (p<0.001) and had the highest diagnostic specificity (87%) with 79% sensitivity and 86% accuracy, which were higher compared to those obtained with MPO, but did not reach statistical significance (P>0.05 for all comparisons). The PDI had higher specificity and accuracy for NSTEMI-A diagnosis compared to coronary angiography (P<0.05). CONCLUSIONS: A PDI measured within 24 hour of troponin positivity has potential to identify subjects with acute Non-ST-elevation type 1 MI. Additional evidence using other marker combinations and investigation in a sufficiently large non-selected cohort is warranted to establish the diagnostic accuracy of the PDI and its potential role in differentiating type 1 and type 2 MI in patients presenting with troponin elevation of uncertain etiology.


Subject(s)
Myocardial Infarction/diagnosis , Troponin I/blood , Aged , Area Under Curve , Biomarkers/blood , Calcium-Binding Proteins/blood , Calgranulin A/blood , Coronary Angiography , Electrocardiography , Female , Humans , Interleukin-6/blood , Linear Models , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Peroxidase/blood , Pregnancy-Associated Plasma Protein-A/analysis , ROC Curve , Sensitivity and Specificity
19.
Can J Cardiol ; 32(12): 1570-1573, 2016 12.
Article in English | MEDLINE | ID: mdl-27743759

ABSTRACT

Currently there are more than 40 centres in Canada that perform more than 65,000 percutaneous coronary interventions (PCIs) in a year. Considering the high volume of procedures and number of operators, the potential for variation in processes of care is high, and might lead to variation in the quality of care. As part of its quality initiative, the Canadian Cardiovascular Society convened a working group to develop a set of PCI Quality Indicators (QIs) that would be relevant, scientifically acceptable, and feasible to measure and report. The working group was comprised of clinical experts from across Canada and members of provincial and federal organizations involved in promoting the quality of health care. Using the Canadian Cardiovascular Society "Best Practices for Developing Cardiovascular Quality Indicators" methodology, a total of 23 QIs were proposed. Subsequent ranking and discussion led to the selection of 8 QIs. The selection and ranking of QIs were on the basis of clinical importance and relevance, scientific acceptability, and feasibility of their operationalization at a national level. The data definitions and technical notes of the QIs were refined after feasibility testing and Web consultation. Feasibility testing indicated that standardization and enhancements of knowledge infrastructure are essential to provide the comprehensive patient data necessary to evaluate the quality of PCI across Canada.


Subject(s)
Cardiovascular Diseases , Percutaneous Coronary Intervention , Quality Indicators, Health Care , Canada/epidemiology , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/surgery , Feasibility Studies , Humans , Outcome Assessment, Health Care/methods , Outcome Assessment, Health Care/standards , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/standards , Percutaneous Coronary Intervention/statistics & numerical data , Practice Guidelines as Topic/standards , Quality Indicators, Health Care/organization & administration , Quality Indicators, Health Care/standards , Societies, Medical/organization & administration , Societies, Medical/standards
20.
J Am Coll Cardiol ; 42(8): 1380-6, 2003 Oct 15.
Article in English | MEDLINE | ID: mdl-14563578

ABSTRACT

OBJECTIVES: We examined the clinical, angiographic, and procedural characteristics determining survival after percutaneous coronary intervention (PCI) for cardiogenic shock. BACKGROUND: The SHOCK (SHould we emergently revascularize Occluded coronaries for Cardiogenic shocK?) trial prospectively enrolled patients with shock complicating acute myocardial infarction (MI). Patients were randomized to a strategy of early revascularization or initial medical stabilization. METHODS: Patients randomized to early revascularization underwent PCI or bypass surgery on the basis of predefined clinical criteria. Patients randomized to early revascularization who underwent PCI and had angiographic films available for analysis are the subject of this report (n = 82). RESULTS: The median time from MI to PCI was 11 h. The majority of patients had occluded culprit arteries (Thrombolysis In Myocardial Infarction [TIMI] grade 0 or 1 flow in 62%) and multivessel disease (81%). One-year mortality in PCI patients was 50%. Mortality was 39% if PCI was successful but 85% if unsuccessful (p < 0.001). Mortality was 38% if TIMI flow grade 3 was achieved, 55% with TIMI grade 2 flow, and 100% with TIMI grade 0 or 1 flow (p < 0.001). Mortality was 67% if severe mitral regurgitation was documented. Independent correlates of mortality were as follows: increasing age (p < 0.001), lower systolic blood pressure (p = 0.009), increasing time from randomization to PCI (p = 0.019), lower post-PCI TIMI flow (0/1 vs. 2/3) (p < 0.001), and multivessel PCI (p = 0.040). CONCLUSIONS: Restoration of coronary blood flow is a major predictor of survival in cardiogenic shock. Benefit appears to extend beyond the generally accepted 12-h post-infarction window. Surgery should be considered in shock patients with severe mitral insufficiency or multivessel disease not amenable to relatively complete percutaneous revascularization.


Subject(s)
Coronary Angiography , Coronary Artery Bypass , Shock, Cardiogenic/mortality , Shock, Cardiogenic/therapy , Stents , Aged , Case-Control Studies , Coronary Circulation , Female , Humans , Male , Multivariate Analysis , Myocardial Infarction/complications , Myocardial Revascularization , Proportional Hazards Models , Selection Bias , Shock, Cardiogenic/diagnostic imaging , Time Factors , Ventricular Dysfunction, Left/therapy
SELECTION OF CITATIONS
SEARCH DETAIL