Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Future Oncol ; 20(9): 547-561, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38197386

ABSTRACT

Aims: To characterize Black, Indigenous and People of Color (BIPOC) adolescent and young adult (AYA) cancer patients' experiences of patient engagement in AYA oncology and derive best practices that are co-developed by BIPOC AYAs and oncology professionals. Materials & methods: Following a previous call to action from AYA oncology professionals, a panel of experts composed exclusively of BIPOC AYA cancer patients (n = 32) participated in an electronic Delphi study. Results: Emergent themes described BIPOC AYA cancer patients' direct experiences and consensus opinion on recommendations to advance antiracist patient engagement from BIPOC AYA cancer patients and oncology professionals. Conclusion: The findings reveal high-priority practices across all phases of research and are instructional for advancing health equity.


Subject(s)
Neoplasms , Patient Participation , Humans , Adolescent , Young Adult , Delphi Technique , Medical Oncology , Neoplasms/therapy
2.
Healthc Inform ; 28(3): 48-50, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21446266

ABSTRACT

Sisters of Mercy Health System chose the SaaS model as a simpler way to plan, execute, and monitor strategic business initiatives. It also provided something that was easy to use and offered quick time to value.


Subject(s)
Contract Services , Hospital Information Systems , Humans , Software
3.
J Card Fail ; 12(7): 568-76, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16952791

ABSTRACT

BACKGROUND: Implantable cardiac pressure monitors require assurance of calibration. This study evaluated if airway pressure responses during Valsalva maneuver (VM) can be used for calibrating intracardiac pressure transducers. METHODS AND RESULTS: Thirty-eight heart failure patients performed VMs while cardiac and airway pressures were recorded. Patients were designated as Lower (L) if baseline PCW was <20 mm Hg (n = 17); otherwise, they were categorized as Higher (H) (n = 21). VMs were repeated in 9 H patients after nitroglycerin. Procedural success was 92% and there were no complications. Differences between filling pressure and airway pressure (effective pressure) were eliminated during VM (RA(eff) = -0.9 +/- 1.3, RVED(eff) = 1.2 +/- 1.1, PCW(eff) = 2.1 +/- 2.8, and LVED(eff) = 0.9 +/- 1.6 mm Hg), and filling pressures were highly correlated with airway pressure r = 0.94. On average, group H had higher PCW(eff) and LVED(eff) than L patients by 1.8 and 2.5 mm Hg (P < or = .002), respectively, but after nitrates their responses were identical. CONCLUSION: The relationships between cardiac filling pressure and airway pressure during the Valsalva maneuver are sufficiently reliable to be considered as a new, noninvasive method for establishing the calibration of cardiac pressure sensors in patients with heart failure.


Subject(s)
Blood Pressure , Coronary Circulation , Heart Failure/physiopathology , Heart/physiopathology , Transducers, Pressure , Aged , Calibration , Diastole , Female , Heart Failure/therapy , Hemodynamics , Humans , Male , Middle Aged , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Pressure , Prostheses and Implants , Pulmonary Wedge Pressure , Respiratory System/physiopathology , Stroke Volume , Valsalva Maneuver , Ventricular Function, Left
6.
Texas; U.S. Lloyd Electric; 1990. 38 p.
Monography in En | Desastres (disasters) | ID: des-9138
SELECTION OF CITATIONS
SEARCH DETAIL