Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 46
Filter
Add more filters

Country/Region as subject
Publication year range
1.
J Arthroplasty ; 38(5): 893-898, 2023 05.
Article in English | MEDLINE | ID: mdl-36493971

ABSTRACT

BACKGROUND: Isolated liner exchange is an option to address polyethylene wear after total hip arthroplasty (THA). The liner can be fixed with either the original locking mechanism or cemented into the acetabular cup. Whether the method used for liner fixation has any bearing on the outcomes in the first and second decade after surgery is still unclear. METHODS: Data for all patients who had undergone isolated liner exchange surgery in our institution between April 1995 and January 2015 were retrieved. Patients were classified according to the type of polyethylene liner (conventional or highly crosslinked polyethylene) and the locking mechanism used (original locking mechanism or cemented). Survivorship and revision rates were compared among different subgroups. A total of 118 isolated liner exchanges were performed and patients had a mean duration of follow-up of 13 years (range, 5 to 25). RESULTS: Overall estimated mean survivorship was 17 years. Use of highly crosslinked polyethylene (HXLPE) had a lower re-revision rate compared to conventional liners (10.5 versus 46.9%) (P < .001). The re-revision rate of exchanges using HXLPE was not affected by the type of fixation (original locking mechanism 11.1 versus cement 10.0%, P = .868). Conversely, using the original locking mechanism with a conventional liner had a higher re-revision rate compared to cemented conventional liners (58.3 versus 12.5%) (P = .024). CONCLUSION: HXLPE liners should be used in insert exchange surgery whenever possible. Re-revision rate of exchanges using HXLPE was not affected by the fixation technique used. Cementing an insert into an acetabular component is associated with good survivorship at a mean of 13 years follow-up.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/methods , Prosthesis Failure , Reoperation , Prosthesis Design , Polyethylene
2.
Int Orthop ; 47(10): 2547-2552, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37247019

ABSTRACT

PURPOSE: Cross-linked polyethylene (PE) has been used with great clinical success in total hip arthroplasty (THA) since its debut in the late 1990's. However, reports regarding this bearing couple near the end of its second decade of service are still scant. The aim of this study was to first determine the long term clinical and radiological results and second Investigate what factors affect wear rates using a metal-on-crosslinked PE bearing articulation. METHODS: 55 THAs using a single brand of cross-linked liner, cementless cup and 28 mm hip ball were performed in 44 patients. Age, sex, Charlson Comorbidity Index (CCI) and need for revision surgery were recorded. Linear and volumetric wear was determined using the Martell method. RESULTS: Mean age at operation was 51.2 (29-73 ± 12.1) years. Mean duration of follow-up was 16.9 years (range 15.0-20.1 ± 1.1 years). Osteolysis was not present in the latest follow-up radiographs. Median linear and volumetric wear rate was 0.038 mm/year (95% CI 0.032-0.047) and 7.115mm3/year (95% CI 6.92-17.25) respectively. Acetabular component position was not found to be related to both linear and volumetric wear. No significant difference was found in the linear and volumetric wear rates of thinner and thicker liners (8 mm or below and > 8 mm) (p = 0.849 and p = 0.64 respectively). CONCLUSION: Metal-on-crosslinked PE is associated with low linear and volumetric wear rates which has virtually obviated osteolysis and has translated to excellent survivorship even at long term follow up. In-vivo oxidation does not appear to be of clinical concern at this point.

3.
BMC Musculoskelet Disord ; 22(1): 685, 2021 Aug 12.
Article in English | MEDLINE | ID: mdl-34384397

ABSTRACT

BACKGROUND: High biomechanical loading is believed to be a risk factor to pain in people with knee osteoarthritis (OA), but controversial findings have been reported on the relationship between external knee adduction moment (KAM) and pain. A more comprehensive analysis considering other factor such as external knee flexion moment (KFM) could help better reveal this relationship. This study explored the relationship between external knee adduction moment and pain intensity in participants with knee osteoarthritis (OA) using an integrated path analysis model. METHODS: This was a cross-sectional study based on laboratory setting. Forty-seven participants with clinical and radiographic medial knee OA were analyzed for their external knee adduction moment (KAM) and knee flexion moment (KFM) during walking using a motion analysis system. Pain intensity was measured by visual analogue scale (VAS) and the pain subscale of the Knee Injury and Osteoarthritis Outcome Score. Varus/valgus alignment was captured and quantified using a bi-planar X-ray system. Using a path analysis model, the relationships between pain intensity, KAM, KFM, OA radiographic severity, knee varus angle and walking speed were examined. RESULTS: The proposed path model met the goodness-of-fit criteria. Based on this model, KAM had a negative effect on VAS pain indirectly through the mediation of KFM. The model indicated KAM and KFM were negatively related to one another; and KFM was positively related to VAS. The KAM index, defined as (KAM/ (KAM + KFM)), was negatively related to VAS. CONCLUSIONS: Path analysis enabled the construction of a more integrated pathokinematic framework for people with knee OA. The KAM index which reflected the load sharing on the frontal and sagittal planes also revealed its relationship with pain. Re-distribution of mechanical loading from frontal to sagittal plane might be a strategy for pain avoidance associated with mechanical irritation.


Subject(s)
Osteoarthritis, Knee , Biomechanical Phenomena , Cross-Sectional Studies , Gait , Humans , Knee Joint/diagnostic imaging , Osteoarthritis, Knee/diagnostic imaging , Pain/diagnosis , Pain/etiology , Walking
4.
J Arthroplasty ; 36(1): 130-134.e2, 2021 01.
Article in English | MEDLINE | ID: mdl-32773268

ABSTRACT

BACKGROUND: Postoperative pain remains a major barrier to a patient's recovery after total knee arthroplasty (TKA). Periarticular corticosteroids in local infiltration analgesics (LIA) and high-dose intravenous corticosteroids have individually shown to improve pain control after TKA. However, potential interactions between them have not been investigated. This study aims to evaluate any combination effect of both routes of corticosteroids in TKA. METHODS: This is a double-blinded, paired, randomized controlled trial involving 1-stage bilateral TKAs. All received 16 mg of dexamethasone intravenously. One knee was randomized to receive LIA with 40 mg of triamcinolone, while the other knee receives LIA without corticosteroids. For each patient, one knee was affected by intravenous steroids only, while the other was under the combined effect of intravenous and periarticular steroids (IVPAS). Knee pain, Southampton wound scores, and functional knee scores (Knee Society Knee Score and Oxford Knee Scores) were compared between knees of the same patient. RESULTS: Forty-six patients (92 TKAs) were included. IVPAS knees showed significantly lower visual analog scale scores from day 1 to 6 weeks (P < .05) and a larger range of movement from day 2 to 4 (P < .05). IVPAS knees achieved active straight leg raise earlier than intravenous steroids (1.6 vs 2.3 days, P < .05). No differences in Southampton wound scores and functional knee scores for up to 1 year. CONCLUSION: Combining intravenous and periarticular corticosteroids improved pain control and recovery after TKA with no increase in wound complications up to 1 year.


Subject(s)
Arthroplasty, Replacement, Knee , Anesthetics, Local/therapeutic use , Arthroplasty, Replacement, Knee/adverse effects , Humans , Injections, Intra-Articular , Pain, Postoperative/drug therapy , Pain, Postoperative/prevention & control , Steroids , Treatment Outcome
5.
Eur J Anaesthesiol ; 37(12): 1157-1167, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33105245

ABSTRACT

BACKGROUND: Corticosteroids can reduce pain but the optimal dose and safety profiles are still uncertain. OBJECTIVE: This study aimed to evaluate two different doses of dexamethasone for pain management and their side effects after total knee arthroplasty. DESIGN: A prospective randomised, controlled trial. SETTING: A tertiary teaching hospital in Hong Kong. PATIENTS: One hundred and forty-six patients were randomly allocated to one of three study groups. INTERVENTIONS: Before operation, patients in group D8, D16 and P received dexamethasone 8 mg, dexamethasone 16 mg and placebo (0.9% saline), respectively. MAIN OUTCOME MEASURES: The primary outcome was postoperative pain score. Secondary outcomes were opioid consumption, physical parameters of the knees and side effects of dexamethasone. RESULTS: Compared with placebo, group D16 patients had significantly less pain during maximal active flexion on postoperative day 3 [-1.3 (95% CI, -2.2 to -0.31), P = 0.005]. There was also a significant dose-dependent trend between pain scores and dexamethasone dose (P = 0.002). Compared with placebo, patients in group D16 consumed significantly less opioid [-6.4 mg (95% CI, -11.6 to -1.2), P = 0.025] and had stronger quadriceps power on the first three postoperative days (all P < 0.05). They also had significantly longer walking distance on postoperative day 1 [7.8 m ([95% CI, 0.85 to 14.7), P = 0.023] with less assistance during walking on the first two postoperative days (all P < 0.029) and significantly better quality-of-recovery scores on postoperative day 1 (P = 0.018). There were significant dose-dependent trends between all the above parameters and dexamethasone dose (all P < 0.05). No significant differences were found in the incidence of chronic pain or knee function 3, 6 and 12 months postoperatively. CONCLUSION: Dexamethasone 16 mg given before total knee arthroplasty led to a reduction in postoperative pain, less opioid consumption, stronger quadriceps muscle power, better mobilisation and better overall quality-of-recovery after operation. No long-term improvement in reduction in pain and function of the knee was found. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT02767882.


Subject(s)
Arthroplasty, Replacement, Knee , Pain Management , Arthroplasty, Replacement, Knee/adverse effects , Dexamethasone , Double-Blind Method , Humans , Pain Measurement , Pain, Postoperative/diagnosis , Pain, Postoperative/drug therapy , Pain, Postoperative/epidemiology , Prospective Studies , Treatment Outcome
6.
J Arthroplasty ; 34(9): 2016-2021, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31176564

ABSTRACT

BACKGROUND: Increase in acetabular cup abduction in total hip arthroplasty (THA) using conventional polyethylene is associated with greater linear wear. Whether this relationship holds true for highly crosslinked liners, particularly with long-term follow-up, is still controversial. The effect of liner thickness on wear of highly cross-linked liners also remains to be clarified.This study sought to determine (1) the long-term clinical and radiological performance of highly cross-linked polyethylene in THA and (2) the effect of acetabular component positioning, polyethylene thickness, and patient demographics on wear. METHODS: Ninety-three THAs using a 28-mm hip ball, single brand of highly cross-linked polyethylene liner, and cementless cup were performed in 87 patients. Clinical outcomes were evaluated using the Harris Hip Score and need for revision surgery. Linear and volumetric wear, presence of osteolysis, and cup abduction angle were assessed. RESULTS: The mean age at operation was 51.4 years. The mean duration of follow-up was 12.7 years (10-16 years). Patients aged >50 years had higher rates of linear wear than those aged <50 years (P = .015). Positive correlation was found between cup abduction angle (P = .014) and cup version (P = .035) with a linear wear rate. Thinner liners (≤7 mm) had similar rates of linear and volumetric wear as thicker liners (≥8 mm) (P = .447). CONCLUSION: This is the only study to demonstrate a positive significant relationship between cup abduction angle and version with linear wear rate in THA with at least 10 years of follow-up. Liner thickness was not found to affect wear rates.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis , Polyethylene/chemistry , Adult , Aged , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osteolysis/etiology , Prosthesis Design , Prosthesis Failure , Reoperation
7.
J Arthroplasty ; 32(5): 1474-1477, 2017 05.
Article in English | MEDLINE | ID: mdl-28089469

ABSTRACT

BACKGROUND: Wound closure is key to prevent infection, facilitate immediate rehabilitation, and improve efficiency of total knee arthroplasty (TKA). Continuous knotless suturing with barbed suture can potentially save time and distribute tension more evenly. However, its role in TKA in terms of cost-effectiveness and wound complications is not clear. This study aims at comparing barbed and traditional sutures' wound closure time and cost in primary TKA. METHODS: One hundred nine knees were randomized into either barbed or traditional group. Synthetic absorbable sutures (Vicryl, Ethicon Inc) and bidirectional barbed sutures (Stratafix, Ethicon Inc) were used. Arthrotomy and subcutaneous wound closure time, wound complications, and rehabilitation parameters in terms of range of motion and Knee Society Score were compared. Patients were followed up to 3 months. RESULTS: Traditional sutures had significantly more positive leak tests (10 vs 2, P value <.05) and wound complications (11 vs 2, P value <.05). No differences in range of motion and Knee Society Score were noted. Arthrotomy and subcutaneous closure time were significantly shorter with barbed sutures (arthrotomy 325 seconds vs 491 seconds; subcutaneous 306 seconds vs 381 seconds, P value <.05). Concerning cost of suture material and operation time, barbed suture on average saved USD 48.7 per TKA in our local institute. CONCLUSION: Bidirectional barbed suture improves the cost-effectiveness of TKA through reducing wound closure time and wound complications.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Suture Techniques/economics , Sutures , Adult , Aged , Arthroplasty, Replacement, Knee/economics , Cost-Benefit Analysis , Female , Humans , Male , Middle Aged , Operative Time , Osteoarthritis, Knee/surgery , Range of Motion, Articular , Treatment Outcome , Wound Healing
8.
Knee Surg Sports Traumatol Arthrosc ; 23(12): 3637-45, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25217311

ABSTRACT

PURPOSE: The current study investigated the accuracy in achieving proper lower limb alignment and individual component positions after total knee arthroplasty (TKA) with 3 different instrumentation techniques. It was hypothesized that patient-specific instruments (PSI) would achieve more accurate lower limb alignment and component positions compared to conventional instruments (CON). METHODS: Ninety knees in 81 patients were randomized in 1:1:1 ratio into CON, computer navigation (NAV) and PSI groups to receive TKA. The surgical routines were standardized. The lower limb mechanical axis and individual component positions were assessed on standard radiographs. Tourniquet time, operation time and patients' functional scores were documented. RESULTS: Conventional instruments and PSI were more likely to result in an excessively flexed femoral component (p = 0.001) compared to NAV. Number of outliers in postoperative lower limb alignment, and other components positions in the coronal and sagittal plane showed no statistically significant difference. The mean tourniquet time and operation time was significantly shorter in CON and PSI groups than NAV group (p < 0.001). Four early complications occurred in the PSI group (p = 0.015). At 3-month follow-up, there was no difference in terms of the knee range of motion and patients' function among the 3 groups. CONCLUSION: No significant radiological and clinical benefit could be demonstrated in using PSI over CON or NAV in TKA. Routine use of PSI is not recommended because of the extra cost and waiting time. LEVEL OF EVIDENCE: I.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Joint/surgery , Surgery, Computer-Assisted/instrumentation , Aged , Arthroplasty, Replacement, Knee/methods , Female , Humans , Knee Joint/physiology , Male , Middle Aged , Operative Time , Postoperative Period , Range of Motion, Articular , Surgery, Computer-Assisted/methods
9.
IEEE J Biomed Health Inform ; 28(5): 2842-2853, 2024 May.
Article in English | MEDLINE | ID: mdl-38446653

ABSTRACT

Kneeosteoarthritis (KOA), as a leading joint disease, can be decided by examining the shapes of patella to spot potential abnormal variations. To assist doctors in the diagnosis of KOA, a robust automatic patella segmentation method is highly demanded in clinical practice. Deep learning methods, especially convolutional neural networks (CNNs) have been widely applied to medical image segmentation in recent years. Nevertheless, poor image quality and limited data still impose challenges to segmentation via CNNs. On the other hand, statistical shape models (SSMs) can generate shape priors which give anatomically reliable segmentation to varying instances. Thus, in this work, we propose an adaptive fusion framework, explicitly combining deep neural networks and anatomical knowledge from SSM for robust patella segmentation. Our adaptive fusion framework will accordingly adjust the weight of segmentation candidates in fusion based on their segmentation performance. We also propose a voxel-wise refinement strategy to make the segmentation of CNNs more anatomically correct. Extensive experiments and thorough assessment have been conducted on various mainstream CNN backbones for patella segmentation in low-data regimes, which demonstrate that our framework can be flexibly attached to a CNN model, significantly improving its performance when labeled training data are limited and input image data are of poor quality.


Subject(s)
Deep Learning , Patella , Tomography, X-Ray Computed , Humans , Patella/diagnostic imaging , Tomography, X-Ray Computed/methods , Algorithms , Image Processing, Computer-Assisted/methods , Neural Networks, Computer
10.
Bone Joint J ; 106-B(3 Supple A): 110-114, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38423107

ABSTRACT

Aims: The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in total hip arthroplasty (THA) at a minimum follow-up of 20 years. Methods: We reviewed the results of 165 THAs using the Omnifit HA system in 138 patients, performed between August 1993 and December 1999. The mean age of the patients at the time of surgery was 46 years (20 to 77). Avascular necrosis was the most common indication for THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (20 to 31). At 20 and 25 years, 113 THAs in 91 patients and 63 THAs in 55 patients were available for review, respectively, while others died or were lost to follow-up. Kaplan-Meier analysis was performed to evaluate the survival of the stem. Radiographs were reviewed regularly, and the stability of the stem was evaluated using the Engh classification. Results: A total of seven stems (4.2%) were revised during the study period: one for aseptic loosening, three for periprosthetic fracture, two for infection, and one for recurrent dislocation. At 20 years, survival with revision of the stem for any indication and for aseptic loosening as the endpoint was 96.0% (95% confidence interval (CI) 92.6 to 99.5) and 98.4% (95% CI 96.2 to 100), respectively. At 25 years, the corresponding rates of survival were 94.5% (95% CI 89.9 to 99.3) and 98.1% (95% CI 95.7 to 99.6), respectively. There was radiological evidence of stable bony fixation in 86 stems (76.1%) and evidence of loosening in four (3.5%) at 20 years. All patients with radiological evidence of loosening were asymptomatic. Conclusion: The Omnifit HA femoral stem offered promising long-term survival into the third decade.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Middle Aged , Arthroplasty, Replacement, Hip/methods , Durapatite , Follow-Up Studies , Prosthesis Design , Prosthesis Failure , Reoperation , Treatment Outcome , Young Adult , Adult , Aged
11.
Arthroplasty ; 6(1): 35, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38951944

ABSTRACT

BACKGROUND: The second-generation metaphyseal cone was useful in managing bone defects in revision knee arthroplasty. However, due to the anatomical constraints in Asian osteometry, the authors utilized a novel free-hand burring technique instead of cannulated reaming for bone preparation. We reported the short-term outcomes of our surgical techniques specific to Asian osteometry. METHODS: We conducted a case series by consecutively recruiting 13 female and 12 male patients (involving 25 knees), with a mean age of 71 years (range, 54-88 years). The patients underwent revision total knee arthroplasty during the period from April 2017 to June 2022. Twenty-three tibial cones and 4 femoral cones using free-hand burring technique were implanted. The mean follow-up duration was 51 months (range 18-80 months). Due to the relatively small bone size and meta-diaphyseal center mismatch in the Asian knees, the free-hand burring technique instead of the cannulated reaming technique was adopted in preparing for cone implantation. The clinical outcomes were knee ranges of motion, the Knee Society Knee scores (KSS), end-of-stem pain, infection, and the need for revision surgery. The radiological outcomes included osteointegration, fracture, and loosening. RESULTS: Mean knee range of motion improved from 83 degrees (range 0°-120°) preoperatively to 106 degrees (range 60°-125°) postoperatively (P < 0.001). Mean KSS improved significantly from 29 (range 0-70) to 69 (range 5-100) (P < 0.001). All cones were osteointegrated. One case had transient end-of-stem pain, two developed intraoperative minor femoral fractures and one suffered from recurrent infection that did not require cone revision. Cone revision-free survivorship was 100%. There was no aseptic loosening. CONCLUSIONS: The second-generation cone implanted with free-hand burring bone preparation yielded promising short-term outcomes in Asian knees.

12.
Osteoarthr Cartil Open ; 6(2): 100448, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38440779

ABSTRACT

Objective: Knee replacement (KR) is the last-resort treatment for knee osteoarthritis. Although radiographic evidence of tibiofemoral joint has been widely adopted for prognostication, patellofemoral joint has gained little attention and may hold additional value for further improvements. We aimed to quantitatively analyse patellofemoral joint through radiomics analysis of lateral view radiographs for improved KR risk prediction. Design: From the Multicenter Osteoarthritis Study dataset, we retrospectively retrieved the initial-visit lateral left knee radiographs of 2943 patients aged 50 to 79. They were split into training and test cohorts at a 2:1 ratio. A comprehensive set of radiomic features were extracted within the best-performing subregion of patellofemoral joint and combined into a radiomics score (RadScore). A KR risk score, derived from Kellgren-Lawrence grade (KLG) of tibiofemoral joint and RadScore of patellofemoral joint, was developed by multivariate Cox regression and assessed using time-dependent area under receiver operating characteristic curve (AUC). Results: While patellofemoral osteoarthritis (PFOA) was insignificant during multivariate analysis, RadScore was identified as an independent risk factor (multivariate Cox p-value < 0.001) for KR. The subgroup analysis revealed that RadScore was particularly effective in predicting rapid progressor (KR occurrence before 30 months) among early- (KLG < 2) and mid-stage (KLG â€‹= â€‹2) patients. Combining two joints radiographic information, the AUC reached 0.89/0.87 for predicting 60-month KR occurrence. Conclusions: The RadScore of the patellofemoral joint on lateral radiographs emerges as an independent prognostic factor for improving KR prognosis prediction. The KR risk score could be instrumental in managing progressive knee osteoarthritis interventions.

13.
Arthroplasty ; 6(1): 33, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38835099

ABSTRACT

BACKGROUND: Survivorship of medial unicompartmental knee arthroplasty (UKA) is technique-dependent. Correct femoral-tibial component positioning associates with improved survivorship. Image-free robotic-assisted unicompartmental knee arthroplasty enables preoperative and intraoperative planning of alignment and assessment of positioning prior to execution. This study aimed to compare the radiological outcomes between robotic-assisted UKA (R-UKA) and conventional UKA (C-UKA). METHODS: This retrospective case control study involved 140 UKA (82 C-UKA and 58 R-UKA) performed at an academic institution between March 2016 to November 2020, with a mean follow-up of 3 years. Postoperative radiographs were evaluated for mechanical axis and femoral-tibial component position. Component position was measured by two methods: (1) femoral-tibial component contact point with reference to four medial-to-lateral quadrants of the tibial tray and (2) femoral-tibial component contact point deviation from the center of the tibial tray as a percentage of the tibial tray width. Baseline demographics and complications were recorded. RESULTS: There was a higher mean component deviation in C-UKA compared with R-UKA using method 2 (17.2% vs. 12.8%; P = 0.007), but no difference in proportion of zonal outliers using method 1 (4 outliers in C-UKA, 5.1% vs. 1 outlier in R-UKA, 1.8%; P = 0.403). R-UKA showed no difference in mean mechanical alignment (C-UKA 5° vs. R-UKA 5°; P = 0.250). 2-year survivorship was 99% for C-UKA and 97% for R-UKA. Mean operative time was 18 min longer for R-UKA (P < 0.001). CONCLUSION: Image-free robotic-assisted UKA had improved component medio-lateral alignment compared with conventional technique.

14.
J Orthop Translat ; 45: 100-106, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38524869

ABSTRACT

Osteoarthritis (OA) is one of the fast-growing disability-related diseases worldwide, which has significantly affected the quality of patients' lives and brings about substantial socioeconomic burdens in medical expenditure. There is currently no cure for OA once the bone damage is established. Unfortunately, the existing radiological examination is limited to grading the disease's severity and is insufficient to precisely diagnose OA, detect early OA or predict OA progression. Therefore, there is a pressing need to develop novel approaches in medical image analysis to detect subtle changes for identifying early OA development and rapid progressors. Recently, radiomics has emerged as a unique approach to extracting high-dimensional imaging features that quantitatively characterise visible or hidden information from routine medical images. Radiomics data mining via machine learning has empowered precise diagnoses and prognoses of disease, mainly in oncology. Mounting evidence has shown its great potential in aiding the diagnosis and contributing to the study of musculoskeletal diseases. This paper will summarise the current development of radiomics at the crossroads between engineering and medicine and discuss the application and perspectives of radiomics analysis for OA diagnosis and prognosis. The translational potential of this article: Radiomics is a novel approach used in oncology, and it may also play an essential role in the diagnosis and prognosis of OA. By transforming medical images from qualitative interpretation to quantitative data, radiomics could be the solution for precise early OA detection, progression tracking, and treatment efficacy prediction. Since the application of radiomics in OA is still in the early stages and primarily focuses on fundamental studies, this review may inspire more explorations and bring more promising diagnoses, prognoses, and management results of OA.

15.
J Knee Surg ; 2024 Sep 02.
Article in English | MEDLINE | ID: mdl-39019474

ABSTRACT

A substantial proportion of Hong Kong's aging population suffers from osteoarthritis in both knees. Bilateral total knee arthroplasty (BTKA) is a surgical option for addressing this condition and can be performed via two approaches: simultaneous BTKA (SimBTKA) and staged BTKA (StaBTKA). We compared the cost-effectiveness and safety of these two methods in our institution. We retrospectively reviewed 2,372 patients (SimBTKA, 772; StaBTKA, 1,600; females, 1,780; males, 592; mean age at SimBTKA, 70.4 ± 7.99 years; mean age at StaBTKA, 66.4 ± 7.50 years; p < 0.001) who underwent BTKA in our institution from 2001 to 2022. Patients were categorized according to the surgical approach. Patients undergoing BTKA in our institution were included. Particularly for SimBTKA, patients were assessed by anesthetists to be medically fit before undergoing the procedure according to their age, American Society of Anesthesiologists status, and osteoarthritis severity. The primary outcome was the length of stay (LOS) after surgery. The secondary outcomes were the 30-day unintended readmission, intensive care unit (ICU) admission, and death. SimBTKA had a shorter mean total LOS (acute hospital + rehabilitation center; SimBTKA, 13.09 days; StaBTKA, 18.12 days; p < 0.001) and mean LOS in acute hospital (SimBTKA, 7.70 days; StaBTKA, 10.42 days; p < 0.001). However, no significant difference was found in the mean LOS in rehabilitation centers (SimBTKA, 5.47 days; StaBTKA, 6.32 days; p > 0.05) between the two approaches. The 30-day unintended readmission rate was lower in SimBTKA (SimBTKA, 2.07%; StaBTKA, 3.30%; odds ratio [OR] = 1.60; p > 0.05) but statistically insignificant. SimBTKA was less costly than StaBTKA by US$ 8,422.22 per patient. No significant differences in ICU admission and death rates were found (p > 0.05) between the two groups. SimBTKA had a shorter LOS and lower cost than StaBTKA and comparable complication rates. Therefore, SimBTKA should be indicated in medically stable patients.

16.
Arthroplasty ; 6(1): 30, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38755708

ABSTRACT

BACKGROUND: The high co-prevalence of obesity and end-stage osteoarthritis requiring arthroplasty, with the former being a risk factor for complications during arthroplasty, has led to increasing interest in employing preoperative weight loss interventions such as bariatric surgery and diet modification. However, the current evidence is conflicting, and this study aimed to investigate the effect of weight loss intervention before arthroplasty in prospective randomized controlled trials. METHODS: Four electronic databases (MEDLINE, EMBASE, Web of Science, and Cochrane Central Register of Controlled Trials) were searched for prospective randomized controlled trials that compared weight loss interventions with usual care from inception to October 2023 by following the PRISMA guidelines. The Cochrane risk of bias tool and GRADE framework were used to assess the quality of the studies. Meta-analyses were performed when sufficient data were available from 2 or more studies. RESULTS: Three randomized controlled trials involving 198 patients were identified. Two studies employed diet modification, and one study utilized bariatric surgery. All three studies reported significant reductions in body weight and body mass index (BMI), and intervention groups had fewer postoperative complications. There was no difference in the length of stay between the intervention group and the control group. Variable patient-reported outcome measures were used by different research groups. CONCLUSION: Weight loss intervention can achieve significant reductions in body weight and body mass index before arthroplasty, with fewer postoperative complications reported. Further studies with different populations could confirm the effect of these interventions among populations with different obesity characteristics.

17.
Osteoarthr Cartil Open ; 6(2): 100461, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38558888

ABSTRACT

Background: Joint space width (JSW) is a traditional imaging marker for knee osteoarthritis (OA) severity, but it lacks sensitivity in advanced cases. We propose tibial subchondral bone area (TSBA), a new CT imaging marker to explore its relationship with OA radiographic severity, and to test its performance for classifying surgical decisions between unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) compared to JSW. Methods: We collected clinical, radiograph, and CT data from 182 patients who underwent primary knee arthroplasty (73 UKA, 109 TKA). The radiographic severity was scored using Kellgren-Lawrence (KL) grading system. TSBA and JSW were extracted from 3D CT-reconstruction model. We used independent t-test to investigate the relationship between TSBA and KL grade, and binary logistic regression to identify factors associated with TKA risk. The accuracy of TSBA, JSW and established classification model in differentiating between UKA and TKA was assessed using AUC. Results: All parameters exhibited inter- and intra-class coefficients greater than 0.966. Patients with KL grade 4 had significantly larger TSBA than those with KL grade 3. TSBA (0.708 of AUC) was superior to minimal/average JSW (0.547/0.554 of AUC) associated with the risk of receiving TKA. Medial TSBA, together with gender and Knee Society Knee Score, emerged as independent classification factors in multivariate analysis. The overall AUC of composite model for surgical decision-making was 0.822. Conclusion: Tibial subchondral bone area is an independent imaging marker for radiographic severity, and is superior to JSW for surgical decision-making between UKA and TKA in advanced OA patients.

18.
Bone Jt Open ; 4(11): 859-864, 2023 Nov 13.
Article in English | MEDLINE | ID: mdl-37952558

ABSTRACT

Aims: The surgical helmet system (SHS) was developed to reduce the risk of periprosthetic joint infection (PJI), but the evidence is contradictory, with some studies suggesting an increased risk of PJI due to potential leakage through the glove-gown interface (GGI) caused by its positive pressure. We assumed that SHS and glove exchange had an impact on the leakage via GGI. Methods: There were 404 arthroplasty simulations with fluorescent gel, in which SHS was used (H+) or not (H-), and GGI was sealed (S+) or not (S-), divided into four groups: H+S+, H+S-, H-S+, and H-S-, varying by exposure duration (15 to 60 minutes) and frequency of glove exchanges (0 to 6 times). The intensity of fluorescent leakage through GGI was quantified automatically with an image analysis software. The effect of the above factors on fluorescent leakage via GGI were compared and analyzed. Results: The leakage intensity increased with exposure duration and frequency of glove exchanges in all groups. When SHS was used and GGI was not sealed (H+S-), the leakage intensity via GGI had the fastest increase, consistently higher than other groups (H+S+, H-S+ and H-S-) after 30 minutes (p < 0.05) and when there were more than four instances of glove exchange (p < 0.05). Additionally, the leakage was strongly correlated with the duration of exposure (rs = 0.8379; p < 0.050) and the frequency of glove exchange (rs = 0.8198; p < 0.050) in H+S-. The correlations with duration and frequency turned weak when SHS was not used (H-) or GGI was sealed off (S+). Conclusion: Due to personal protection, SHS is recommended in arthroplasties. Meanwhile, it is strongly recommended to seal the GGI of the inner gloves and exchange the outer gloves hourly to reduce the risk of contamination from SHS.

19.
Arthroplast Today ; 23: 101218, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37841451

ABSTRACT

Hip prosthetic joint infection management is complex and expensive, especially in severe bone loss. Reducing the price of interval prosthesis when performing staged revision could minimize costs without compromising outcomes. We present 2 similar techniques developed independently that use an antibiotic-coated cephalomedullary nail with a total hip arthroplasty bearing (head and cemented acetabular component) attached to it as an interval proximal femoral replacement prosthesis. Using this technique, the femoral implant cost was reduced up to 10-fold. All patients have recovered well with resolution of infection and functional recovery similar to patients undergoing proximal femoral replacement. In one case, the lag screw (femoral neck) fractured at 5 months prompting the second-stage revision. This complication should be considered when deciding the timing of second-stage revisions in these cases.

20.
J Orthop Case Rep ; 13(10): 6-10, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37885636

ABSTRACT

Introduction: There is interest in partial exchange for infected total hip arthroplasty, as an alternative to complete removal of components in a traditional two-stage revision. Partial exchange avoids the difficulty of removing a well-fixed component and its associated bone loss. Case Report: We report a case of a 61-year-old male patient with an infected total hip arthroplasty, who underwent a two-stage partial exchange, with retention of the well-fixed femoral stem, and an interim cemented liner. He had excellent function and no infection recurrence at 4 years of follow-up. Conclusion: Two-stage partial exchange with interim cemented liner could be an effective option for infected total hip arthroplasty.

SELECTION OF CITATIONS
SEARCH DETAIL