Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Am J Gastroenterol ; 2024 Jan 12.
Article in English | MEDLINE | ID: mdl-38084850

ABSTRACT

INTRODUCTION: This study aimed to compare the accuracy of polyp size measurements using a virtual scale endoscope (VSE) with an integrated laser-based adaptive scale function and visual assessment (VA) during colonoscopies. METHODS: We conducted a single-blinded, prospective randomized controlled trial. Eligible patients (aged 45-80 years) undergoing screening, surveillance, or diagnostic colonoscopies were randomly assigned (1:1) into 2 groups. In the intervention group, all detected polyps were measured for size using VSE; in the control group, all polyps were measured using VA. Size measurements were compared with a reference standard of digital caliper measurement immediately post polypectomy. The primary outcome was the relative accuracy of real-time VSE measurement compared with VA. Secondary outcomes included the mean differences and the correlations between VSE or VA sizes and the reference standard of measurement. RESULTS: Overall, 230 patients were enrolled and randomized. The relative size measurement accuracy of VSE was 84% in 118 polyps, which was significantly higher than that of VA (105 polyps; 68.4%, P < 0.001). VSE resulted in a significantly higher percentage of size measurements within 25% of true size compared with VA (81.4% vs 41%, P < 0.001). VSE had a significantly lower percentage for >5-mm polyps incorrectly sized as 1-5 mm compared with VA (13.5% vs 57.1%; P < 0.001) and a significantly lower percentage for >3-mm polyps incorrectly sized as 1-3 mm compared with VA (11.3% vs 56.5%; P < 0.001). DISCUSSION: VSE significantly improves the size measurement accuracy of colorectal polyps during colonoscopies compared with VA and results in fewer misclassifications at relevant decision-making size thresholds.

2.
Gastrointest Endosc ; 99(4): 557-565, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37951281

ABSTRACT

BACKGROUND AND AIMS: Stent dysfunction is common after ERCP with self-expandable metal stent (SEMS) insertion for malignant distal biliary obstruction (MDBO). Chronic aspirin (acetylsalicylic acid; ASA) exposure has been previously shown to potentially decrease this risk. We aim to further ascertain the protective effect of ASA and to identify other predictors of stent dysfunction. METHODS: This multicenter retrospective cohort study was conducted at 9 sites in Canada and 1 in the United States. Patients with MDBO who underwent ERCP with SEMS placement between January 2014 and December 2019 were included and divided into 2 cohorts: ASA exposed (ASA-E) and ASA unexposed (ASA-U). Propensity-score matching (PSM) was performed to limit selection bias. Matched variables were age, sex, tumor stage, and type of metal stent. The primary outcome was the hazard rate of stent dysfunction. A multivariable Cox proportional hazards model was used to identify independent predictors of stent dysfunction. RESULTS: Of 1396 patients assessed, after PSM 496 patients were analyzed (248 ASA-E and 248 ASA-U). ERCP with SEMS placement was associated with a high clinical success of 82.2% in ASA-E and 81.2% in ASA-U cohorts (P = .80). One hundred eighty-four patients had stent dysfunction with a mean stent patency time of 229.9 ± 306.2 days and 245.4 ± 241.4 days in ASA-E and ASA-U groups, respectively (P = .52). On multivariable analysis, ASA exposure did not protect against stent dysfunction (hazard ratio [HR], 1.25; 95% confidence interval [CI], .96-1.63). An etiology of pancreatic cancer (HR, 1.36; 95% CI, 1.15-1.61) predicted stent dysfunction, whereas cancer therapy was protective (HR, .73; 95% CI, .55-.96). Chronic ASA use was not associated with an increased risk for adverse events including bleeding, post-ERCP pancreatitis, and perforation. CONCLUSIONS: In this large, multicenter study using PSM, chronic exposure to ASA did not protect against stent dysfunction in MDBO. Instead, the analysis revealed that the etiology of pancreatic cancer was an independent predictor of stent dysfunction and cancer therapy was protective.


Subject(s)
Cholestasis , Pancreatic Neoplasms , Self Expandable Metallic Stents , Humans , Aspirin/therapeutic use , Cholestasis/etiology , Cholestasis/surgery , Pancreatic Neoplasms/pathology , Propensity Score , Retrospective Studies , Self Expandable Metallic Stents/adverse effects , Stents/adverse effects , Treatment Outcome , Male , Female
SELECTION OF CITATIONS
SEARCH DETAIL