1.
Part Fibre Toxicol ; 20(1): 46, 2023 Nov 29.
Article in English | MEDLINE | ID: mdl-38031128

ABSTRACT

BACKGROUND: Nanoplastics (NPs) could be released into environment through the degradation of plastic products, and their content in the air cannot be ignored. To date, no studies have focused on the cardiac injury effects and underlying mechanisms induced by respiratory exposure to NPs. RESULTS: Here, we systematically investigated the cardiotoxicity of 40 nm polystyrene nanoplastics (PS-NPs) in mice exposed via inhalation. Four exposure concentrations (0 µg/day, 16 µg/day, 40 µg/day and 100 µg/day) and three exposure durations (1 week, 4 weeks, 12 weeks) were set for more comprehensive information and RNA-seq was performed to reveal the potential mechanisms of cardiotoxicity after acute, subacute and subchronic exposure. PS-NPs induced cardiac injury in a dose-dependent and time-dependent manner. Acute, subacute and subchronic exposure increased the levels of injury biomarkers and inflammation and disturbed the equilibrium between oxidase and antioxidase activity. Subacute and subchronic exposure dampened the cardiac systolic function and contributed to structural and ultrastructural damage in heart. Mechanistically, violent inflammatory and immune responses were evoked after acute exposure. Moreover, disturbed energy metabolism, especially the TCA cycle, in the myocardium caused by mitochondria damage may be the latent mechanism of PS-NPs-induced cardiac injury after subacute and subchronic exposure. CONCLUSION: The present study evaluated the cardiotoxicity induced by respiratory exposure to PS-NPs from multiple dimensions, including the accumulation of PS-NPs, cardiac functional assessment, histology observation, biomarkers detection and transcriptomic study. PS-NPs resulted in cardiac injury structurally and functionally in a dose-dependent and time-dependent manner, and mitochondria damage of myocardium induced by PS-NPs may be the potential mechanism for its cardiotoxicity.


Subject(s)
Cardiotoxicity , Nanoparticles , Animals , Mice , Polystyrenes/toxicity , Microplastics , Myocardium , Biomarkers
2.
Ecotoxicol Environ Saf ; 249: 114385, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36508803

ABSTRACT

Microplastics and Nanoplastics (MNPLs) pollution has been recognized as the important environmental pollution caused by human activities in addition to global warming, ozone layer depletion and ocean acidification. Most of the current studies have focused on the toxic effects caused by plastics and have not actively investigated the mechanisms causing cell death, especially at the subcellular level. The main content of this paper focuses on two aspects, one is a review of the current status of MNPLs contamination and recent advances in toxicological studies, which highlights the possible concentration levels of MNPLs in the environment and the internal exposure of humans. It is also proposed to pay attention to the compound toxicity of MNPLs as carriers of other environmental pollutants and pathogenic factors. Secondly, subcellular toxicity is discussed and the modes of entry and intracellular distribution of smaller-size MNPLs are analyzed, with particular emphasis on the importance of organelle damage to elucidate the mechanism of toxicity. Importantly, MNPLs are a new type of environmental pollutant and researchers need to focus not only on their toxicity, but also work with governments to develop measures to reduce plastic emissions, optimize degradation and control plastic aggression against organisms, especially humans, from multiple perspectives.


Subject(s)
Environmental Pollutants , Water Pollutants, Chemical , Animals , Humans , Plastics/toxicity , Hydrogen-Ion Concentration , Seawater , Environmental Pollution , Microplastics/toxicity , Water Pollutants, Chemical/toxicity , Water Pollutants, Chemical/analysis , Environmental Monitoring
3.
Appl Opt ; 61(9): 2198-2206, 2022 Mar 20.
Article in English | MEDLINE | ID: mdl-35333234

ABSTRACT

This paper proposes a design process for additively manufactured mirrors. A central support aspheric mirror and tripod support structure were manufactured via selective laser melting. To achieve substantial weight reduction, an additively manufactured body-centered cubic lattice structure was used in the mirror design. Simulation analysis showed that the mirror had good rigidity. Single-point diamond turning was applied to obtain an optical quality mirror. After assembly, the rms surface shape accuracy of the mirror was 0.069λ (λ=632.8nm). The surface roughness (Ra) of the additively manufactured metal mirror was 8.125 nm. These findings provide a strong theoretical basis and technical support for the preparation and application of lightweight metal mirrors.

4.
Environ Chem Lett ; 20(5): 2951-2970, 2022.
Article in English | MEDLINE | ID: mdl-35791338

ABSTRACT

During the Corona Virus Disease 2019 (COVID-19) pandemic, protective equipment, such as masks, gloves and shields, has become mandatory to prevent person-to-person transmission of coronavirus. However, the excessive use and abandoned protective equipment is aggravating the world's growing plastic problem. Moreover, above protective equipment can eventually break down into microplastics and enter the environment. Here we review the threat of protective equipment associated plastic and microplastic wastes to environments, animals and human health, and reveal the protective equipment associated microplastic cycle. The major points are the following:1) COVID-19 protective equipment is the emerging source of plastic and microplastic wastes in the environment. 2) protective equipment associated plastic and microplastic wastes are polluting aquatic, terrestrial, and atmospheric environments. 3) Discarded protective equipment can harm animals by entrapment, entanglement and ingestion, and derived microplastics can also cause adverse implications on animals and human health. 4) We also provide several recommendations and future research priority for the sustainable environment. Therefore, much importance should be attached to potential protective equipment associated plastic and microplastic pollution to protect the environment, animals and humans.

5.
Ecotoxicol Environ Saf ; 226: 112837, 2021 Dec 15.
Article in English | MEDLINE | ID: mdl-34619472

ABSTRACT

Nanoplastics, including polystyrene nanoplastics (PS-NPs), are widely existed in the atmosphere, which can be directly and continuously inhaled into the human body, posing a serious threat to the respiratory system. Therefore, it is urgent to estimate the potential pulmonary toxicity of airborne NPs and understand its underlying mechanism. In this research, we used two types of human lung epithelial cells (bronchial epithelium transformed with Ad12-SV40 2B, BEAS-2B) and (human pulmonary alveolar epithelial cells, HPAEpiC) to investigate the association between lung injury and PS-NPs. We found PS-NPs could significantly reduce cell viability in a dose-dependent manner and selected 7.5, 15 and 30 µg/cm2 PS-NPs as the exposure dosage levels. Microarray detection revealed that 770 genes in the 7.5 µg/cm2 group and 1951 genes in the 30 µg/cm2 group were distinctly altered compared to the control group. Function analysis suggested that redox imbalance might play central roles in PS-NPs induced lung injury. Further experiments verified that PS-NPs could break redox equilibrium, induce inflammatory effects, and triggered apoptotic pathways to cause cell death. Importantly, we found that PS-NPs could decrease transepithelial electrical resistance by depleting tight junctional proteins. Result also demonstrated that PS-NPs-treated cells increased matrix metallopeptidase 9 and Surfactant protein A levels, suggesting the exposure of PS-NPs might reduce the repair ability of the lung and cause tissue damage. In conclusion, nanoplastics could induce oxidative stress and inflammatory responses, followed by cell death and epithelial barrier destruction, which might result in tissue damage and lung disease after prolonged exposure.


Subject(s)
Microplastics , Nanoparticles , Coculture Techniques , Epithelial Cells , Humans , Lung , Microarray Analysis , Polystyrenes
6.
J Cell Physiol ; 235(1): 548-562, 2020 01.
Article in English | MEDLINE | ID: mdl-31232471

ABSTRACT

Accumulating evidence implies that N6-methyladenosine (m6A) methylation participated in the tumorigenesis of gastric cancer (GC). Here we synthetically analyzing the prognostic value and expression profile of seven m6A methylation-relevant genes through silico analysis of sequencing data downloaded from The Cancer Genome Atlas, Kaplan-Meier plotter, and Gene Expression Omnibus database. We explored the methyltransferase-like 3 (METTL3) expression in GC cell line and tumor tissues by reverse transcription quantitative polymerase chain reaction and western blot analysis. The m6A methylation status of total RNA was measured by m6A RNA methylation quantification kit. Small interfering RNA was used to establish METTL3 knockdown cell lines. We also measure the proliferation and migration capability GC cell. Furthermore, we detect the epithelial cell mesenchymal transition marker and m6A methylation level after METTL3 knock down. Our result revealed that METTL3 was significantly increased in GC tissues compared with control in big crowd data sets. Survival analysis showed that METTL3 serve as a poor prognostic factor for GC patients. The expression level of METTL3 gradually increased with the progress of tumor stage and grade. GFI1 is an important transcription factor associated with METTL3. We verified the up-trend of METTL3 in messenger RNA and protein expression and observed a significant increase in the m6A methylation status of total RNA in the GC cells and tissues. METTL3 knockdown inhibited total RNA m6A methylation level, as well as cell proliferation and migration capacity. Moreover, METTL3 knockdown decreased α-smooth muscle actin. Taken together, our finding revealed that m6A methylation writer METTL3 serve as an oncogene in tumorigenesis of GC.


Subject(s)
Adenosine/analogs & derivatives , Carcinogenesis/genetics , DNA Methylation/genetics , Methyltransferases/metabolism , Stomach Neoplasms/genetics , Actins/metabolism , Adenosine/metabolism , Cell Line, Tumor , Cell Movement/genetics , Cell Proliferation/genetics , DNA-Binding Proteins/metabolism , Databases, Genetic , Disease Progression , Female , Gene Expression Profiling , Humans , Male , Methyltransferases/genetics , Neoplasm Staging , Prognosis , RNA Interference , RNA, Messenger/biosynthesis , RNA, Small Interfering/genetics , Stomach Neoplasms/pathology , Transcription Factors/metabolism
7.
J Cell Biochem ; 121(4): 2889-2900, 2020 04.
Article in English | MEDLINE | ID: mdl-31692042

ABSTRACT

Lung cancer is one of the deadliest cancers worldwide. To increase the survival rate of lung cancer, it is necessary to explore specific prognosis markers. More and more evidence finds that noncoding RNA is closely associated with the survival of lung cancer, and cancer stem cells (CSCs) also play a significant role in the progress of lung cancer. The objective of this study is to find CSLCs genes that affect the prognosis of lung cancer. The differential expression of long noncoding RNAs (lncRNAs), microRNAs (miRNAs), messenger RNAs (mRNAs) in the Cancer Genome Atlas (TCGA) database and differential expression data from microarray of CD326+ and CD326- A549 cell are intersected to identify stable and consistent expression genes (2 lncRNAs, 15 miRNAs, and 134 mRNAs). The intersection of lncRNAs and miRNAs is analyzed by univariate and multivariate Cox regression to obtained prognostic genes. Two miRNAs (miR-30b-5p and miR-29c-3p) are significantly correlated with the overall survival rate. Then using these two miRNAs to construct a risk score model as a prognosis signature of lung cancer. Subsequently, we analyzed the association between two miRNAs and clinical information of lung cancer patients, of which T stage, Neoplasm cancer and risk score (P < .05) can be used as independent prognostic indicators of lung cancer. Finally, target genes of 2 miRNAs and 134 mRNAs were annotated with Gene Ontology and analyzed with Kyoto Encyclopedia of Genes and Genomes pathway, and verified with the GEO database. In summary, this study illustrates the role of miRNAs in the promotion of lung cancer by CSCs, which is important to find molecular biomarkers of lung cancer.


Subject(s)
Lung Neoplasms/genetics , MicroRNAs/metabolism , Neoplastic Stem Cells/cytology , A549 Cells , Animals , Biomarkers, Tumor , Cell Line, Tumor , Epithelial Cell Adhesion Molecule/metabolism , Female , Genome, Human , Humans , Lung Neoplasms/diagnosis , Lung Neoplasms/metabolism , Male , MicroRNAs/genetics , Middle Aged , Prognosis , Proportional Hazards Models
8.
Catheter Cardiovasc Interv ; 95(7): 1277-1284, 2020 06 01.
Article in English | MEDLINE | ID: mdl-32105408

ABSTRACT

AIMS: Peripheral arteries are constantly exposed to deformation (elongation, twisting, shortening, compression) making bioresorbable scaffolds (BRS) a potentially attractive therapeutic alternative to metallic stents. We conducted a long-term pilot preclinical study of a novel sirolimus-eluting BRS in peripheral arteries. METHODS AND RESULTS: Fourteen BRS were deployed in iliofemoral arteries of seven healthy Yucatan miniswine and examined with imaging, pharmacokinetic, histopathologic, and polymer degradation techniques at 0, 30, 90, 180 days, 1, 2, and 3.3 years. Angiographic late luminal loss remained unchanged at 30 and 180 days but significantly decreased from 1 to 3.3 years. optical coherence tomography (OCT) showed late increase in lumen area (1 year: 14.70 ± 3.58 mm2 , 2 years 22.04 ± 3.81 mm2 , and 3.3 years 23.45 ± 7.07 mm2 ; p < .05) primarily due to scaffold area enlargement between 1 and 3.3 years, while there was no difference in the percent area stenosis at all time points. Histologic evidence of scaffold degradation was observed starting at 2 years, with minimal inflammatory reaction. At 3.3 years, BRS struts were rarely discernible by OCT, confirmed by a nearly complete polymer degradation by molecular weight analysis. CONCLUSIONS: In this pilot study, novel sirolimus-eluting BRS showed promising acute and chronic performance in the iliofemoral arteries of Yucatan miniswine.


Subject(s)
Absorbable Implants , Angioplasty, Balloon/instrumentation , Cardiovascular Agents/administration & dosage , Femoral Artery/drug effects , Iliac Artery/drug effects , Sirolimus/administration & dosage , Angioplasty, Balloon/adverse effects , Animals , Cardiovascular Agents/pharmacokinetics , Equipment Design , Femoral Artery/diagnostic imaging , Femoral Artery/pathology , Iliac Artery/diagnostic imaging , Iliac Artery/pathology , Materials Testing , Models, Animal , Pilot Projects , Sirolimus/pharmacokinetics , Swine , Swine, Miniature , Time Factors
9.
Cancer Sci ; 110(12): 3639-3649, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31605436

ABSTRACT

The digestive system cancers are aggressive cancers with the highest mortality worldwide. In this study, we undertook a systematic investigation of the tumor immune microenvironment to identify diagnostic and prognostic biomarkers. The fraction of 22 immune cell types of patients were estimated using CIBERSORT. The least absolute shrinkage and selection operator (LASSO) analysis was carried out to identify important immune predictors. By comparing immune cell compositions in 801 tumor samples and 46 normal samples, we constructed the diagnostic immune score (DIS), showing high specificity and sensitivity in the training (area under the receiver operating characteristic curve [AUC] = 0.929), validation (AUC = 0.935), and different cancer type cohorts (AUC > 0.70 for all). We also established the prognostic immune score (PIS), which was an effective prognostic factor for relapse-free survival in training, validation, and entire cohorts (P < .05). In addition, PIS provided a higher net benefit than TNM stage. A composite nomogram was built based on PIS and patients' clinical information with well-fitted calibration curves (c-index = 0.84). We further used other cohorts from Gene Expression Omnibus databases and obtained similar results, confirming the reliability and validity of the DIS and PIS. In addition, the unsupervised clustering analysis using immune cell proportions revealed 6 immune subtypes, suggesting that the immune types defined as having relatively high levels of M0 or/and M1 macrophages were the high-risk subtypes of relapse. In conclusion, this study comprehensively analyzed the tumor immune microenvironment and identified DIS and PIS for digestive system cancers.


Subject(s)
Digestive System Neoplasms/immunology , Aged , Biomarkers, Tumor/analysis , Digestive System Neoplasms/diagnosis , Digestive System Neoplasms/mortality , Female , Humans , Macrophages/immunology , Male , Middle Aged , Nomograms , Prognosis , Proportional Hazards Models , Tumor Microenvironment
10.
Catheter Cardiovasc Interv ; 91(3): 378-386, 2018 02 15.
Article in English | MEDLINE | ID: mdl-28471065

ABSTRACT

OBJECTIVES: The aim of the study was to evaluate the biomechanical properties and healing pattern of novel sirolimus-eluting, ultrahigh molecular weight amorphous poly-L-lactic acid bioresorbable scaffolds (S-BRS) that have been postdilated by 0.55 and 0.8 mm beyond the nominal diameters within the pressure-diameter compliance chart range. BACKGROUND: Due to the inherent limitations of bioabsorbable polymeric materials, overexpansion/upsizing may be very limited for some BRS such as the benchmark Absorb BVS. The unique biomechanical properties of the novel S-BRS may allow it to be safely upsized. METHODS AND RESULTS: 12 coronary arteries of 4 healthy Yucatan mini-swine underwent implantation of a novel S-BRS. Upsizing by postdilation was performed up to 0.55mm (PLUS 0.55, n = 6) or 0.8 mm (PLUS 0.8, n = 6) in a manner maintaining consistent 1:1.1 stent-to-artery, thus ensuring not only the overexpansion of the scaffold but consistent level of arterial injury. Optical coherence tomography (OCT) follow-up was performed at 28 and 90-days follow-up. There was no statistical difference between the tested groups in terms of acute recoil. OCT analysis after 28 days showed numerically lower levels of neointimal formation in PLUS 0.8 compared to PLUS 0.55 group. These results were sustained at 90-days follow-up. There was no difference in late recoil between studied groups. No scaffold discontinuation, deformation or overlapping of the struts were observed. CONCLUSIONS: Overexpansion up to 0.8 mm of novel, high strength S-BRS is not associated with worse angiographic outcomes, neointimal formation or biomechanical issues such as scaffold discontinuation, deformation or overlapping of the struts, neither acutely nor chronically. © 2017 Wiley Periodicals, Inc.


Subject(s)
Absorbable Implants , Angioplasty, Balloon, Coronary/instrumentation , Coronary Vessels/surgery , Polyesters/chemistry , Tomography, Optical Coherence , Angioplasty, Balloon, Coronary/adverse effects , Animals , Coronary Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Materials Testing , Models, Animal , Molecular Weight , Predictive Value of Tests , Prosthesis Design , Swine , Swine, Miniature , Time Factors , Ultrasonography, Interventional
11.
Zhongguo Zhong Xi Yi Jie He Za Zhi ; 36(3): 322-6, 2016 Mar.
Article in Zh | MEDLINE | ID: mdl-27236890

ABSTRACT

OBJECTIVE: To explore the effect of electroacupuncture (EA) on the expression of Ghrelin and mRNA expression of its receptor in functional dyspepsia (FD) rats. METHODS: Totally 80 rats were divided into the normal group, the model group, the drug therapy group, and the EA group according to random digit table, 20 in each group. FD model was duplicated by clipping tail modeling. Drug containing cisapride [2 mL/100 g, 0.09 g/(kg x d)] was administered to rats in the drug therapy group from the 3rd day after successful modeling, once per day. EA at Zusanli (ST36) (0.3-0.5 cun) and Taichong (LR3) (0.1-0.2 cun) was performed in the EA group. The twirling of needle was performed to the subsidence of needle, and then the needle was connected to HANS-200A Acupoint Nerve Stimulating Device using disperse-dense wave at 2 Hz, 2 mA, 30 min each time, once per day. Six days consisted of one therapeutic course, two courses in total with an interval of one day. The intestinal propulsive rate of ink was observed. Ghrelin protein expression in gastric tissue was detected by Western blot. mRNA expression of growth hormone secretagogue receptor (GHS-R) in stomach, hypothalamus, and hippocampus was detected using Real-time PCR respectively. RESULTS: Compared with the normal group, the intestinal propulsive rate of ink, Ghrelin protein expression in gastric tissue, mRNA expression of GHS-R in stomach, hypothalamus, and hippocampus decreased in the model group (P < 0.05, P < 0.01). Compared with the model group, the intestinal propulsive rate of ink, Ghrelin protein expression in gastric tissue, mRNA expression of GHS-R in stomach, hypothalamus, and hippocampus increased in the EA group (P < 0.01); mRNA expression of GHS-R in stomach, hypothalamus, and hippocampus increased in the drug therapy group (P < 0.01). Compared with the drug therapy group, Ghrelin protein expression in gastric tissue, mRNA expression of GHS-R in hypothalamus increased in the EA group (P < 0.05, P < 0.01). CONCLUSION: EA could regulate Ghrelin content and GHS-R mRNA expression of FD rat hypothalamus, hippocampus, and gastric tissue, and promote the intestinal propulsive rate of ink.


Subject(s)
Dyspepsia/therapy , Electroacupuncture , Ghrelin/metabolism , Receptors, Ghrelin/metabolism , Acupuncture Points , Animals , Dyspepsia/metabolism , Gastric Mucosa/metabolism , Hippocampus/metabolism , Hypothalamus/metabolism , RNA, Messenger/metabolism , Random Allocation , Rats
12.
Catheter Cardiovasc Interv ; 86(1): 173-81, 2015 Jul.
Article in English | MEDLINE | ID: mdl-24130158

ABSTRACT

OBJECTIVES: Aimed to evaluate the feasibility of deployment and healing response of a novel transcatheter left atrial appendage (LAA) occlusion device in the canine model BACKGROUND: LAA occlusion is proposed to reduce the risk of stroke in atrial fibrillation patients METHODS: Transseptal puncture and device deployment was guided under fluoroscopy and transesophageal echocardiography (TEE) in five dogs. First, a distal cylindrical bulb occluder was released and secured to the appendage wall with hooks. Subsequently, a proximal sail was unfolded, covering the LAA ostium. Rotational angiography, TEE, and histology outcomes were assessed 30 days following implantation RESULTS: Pre-operative TEE revealed the mean diameter of the LAA ostium to be 17.2 ± 1.6 mm with a depth of 18.5 ± 1.7 mm. The landing zone for the distal bulb was measured to be 12.8 ± 1.3 mm. The mean bulb diameter at implant was 16.8 ± 1.8 mm. Post-operative TEE showed adequate positioning and successful LAA occlusion with all implanted devices. Pericardial effusion requiring pericardiocentesis was seen in one animal following device implantation. At 30 days, TEE revealed full occlusion of all LAA ostia with the exception of a minimal peri-device leak (<3 mm) observed in one animal. No pericardial effusion or device-related thrombus formation was found at termination. Histological analysis confirmed circumferential occlusion of all appendages and complete neointimal coverage on the luminal aspect of the occluder CONCLUSION: The percutaneous delivery of a novel self-positioning LAA occlusion device is feasible and safe in a canine model. At 30 days, all devices displayed complete healing and occlusion of the LAA without any device related adverse events.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Surgical Procedures/instrumentation , Stroke/prevention & control , Sutures , Animals , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Cardiac Catheterization , Disease Models, Animal , Dogs , Echocardiography, Transesophageal , Fluoroscopy , Ligation/instrumentation , Stroke/etiology
13.
Catheter Cardiovasc Interv ; 83(3): 397-404, 2014 Feb 15.
Article in English | MEDLINE | ID: mdl-25295313

ABSTRACT

Background: Self-expanding stents (SES) are reemerging as therapeutic alternatives to treat coronary artery disease. It has been proposed that SES can improve clinical outcomes by inducing less injury at implantation and achieving better vessel wall apposition.To date, little data exists comparing the vascular response to both methods of deployment in a controlled experimental setting. Objective: To quantify differences in vascular injury and healing between second-generation SES and balloon-expandable stents (BES) and the effects of balloon post-dilatation in a porcine coronary model. Methods: Seventy-five bare SES (AXXESS or vProtect) and 42 BES (Vision) were implanted in porcine coronaries. A subset of these received balloon post-dilatation(SES 1 D 5 22, BES 1 D 5 20). Follow-up was scheduled at 30 (BES 5 10, BES 1 D 56, SES 5 19, SES 1 D 5 8), 90 (BES 5 6, BES 1 D 5 8, SES 5 19, SES 1 D 5 8), and 180 days (BES 5 6, BES 1 D 5 6, SES 5 15, SES 1 D 5 6). Results: In vivo imaging and histological analysis showed that neointimal formation peaks early (30 days) in BES. Conversely, for SES, the peak occurred later (90 days). However, the neointimal formation achieved in either group equalized at 180 days. For SES, post-dilatation shortened the peak of neointimal formation to 30 days. Conversely, for BES, post-dilatation delayed the peak of neointimal formation to 90 days. At 30 days, histology showed that SES had significantly less injury. However, at 90 days, injury scores tended to be higher for SES. By 180 days, injury scores were comparable between both groups. Conclusions: The mechanism of stent expansion influences the degree of vascular injury and healing. The synergistic use of balloon post dilatation changes the dynamics of healing and may impact the potential beneficial effects inherent to SES technologies.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Artery Disease/surgery , Stents , Tunica Intima/physiopathology , Vascular System Injuries/prevention & control , Wound Healing , Angioplasty, Balloon, Coronary/methods , Animals , Coronary Artery Disease/pathology , Coronary Artery Disease/physiopathology , Disease Models, Animal , Equipment Design , Injury Severity Score , Stents/adverse effects , Stents/standards , Swine , Time Factors , Tunica Intima/injuries , Vascular Patency , Vascular System Injuries/etiology
14.
J Cardiol ; 83(3): 184-190, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37684005

ABSTRACT

BACKGROUND: As the catheter-based device closure of the patent foramen ovale (PFO) is expanding, novel devices aim to address the limitations of first-generation occluders (e.g. bulk, erosion, dislodgment). The second-generation device from Encore Medical (Eagan, MN, USA) features an articulating frame structure which allows the device to better conform to atrial anatomies, has lower disc thickness and metal mass/surface area, and is fully retrievable at any point in the procedure. The aim of the study was to evaluate the feasibility and safety of a novel low-profile, fully retrievable, Encore PFO closure device in the animal model. METHODS: Six swine underwent implantation of the novel PFO occluder under fluoroscopic and intra-cardiac echocardiography guidance and survived for 140 days. Interim transthoracic echocardiography (TTE) was conducted on Day 29. Following terminal angiography and TTE at 140 days, the hearts were subjected to gross and histopathologic analysis. RESULTS: All animals were successfully implanted and survived for 140 days. Interim TTE revealed proper device retention with no blood flow across the septum or thrombus in any of the animals. X-ray and pathology results showed preserved implant integrity with no fractures, and complete integration of the devices into the septum with complete re-endothelialization and nearly complete coverage by a mature, relatively thin neoendocardium. No surface fibrin deposition or thrombosis was reported. CONCLUSIONS: In the standard porcine model, device retention and biocompatibility remained favorable following structural and functional device modifications exemplified by the second-generation PFO occluder from Encore Medical, including marked reduction of metal mass.


Subject(s)
Foramen Ovale, Patent , Septal Occluder Device , Swine , Animals , Treatment Outcome , Cardiac Catheterization/methods , Echocardiography , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/surgery , Fluoroscopy
15.
Eur J Oral Sci ; 121(3 Pt 1): 211-7, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23659245

ABSTRACT

This study was designed to investigate the ability of orthodontic adhesives to adsorb and release chlorhexidine (CHX) after periodic treatment with 1% CHX solution. Composite and resin-modified glass-ionomer cement (RM-GIC) adhesive disks were incubated with whole saliva or distilled water for 2 h. Release of CHX was measured using high-performance liquid chromatography after 1, 2, and 5 d of incubation, 1 min after exposure to 1% CHX solution. The CHX measurements were performed in a 5-d cycle, which was repeated four consecutive times (n = 7). The amount of CHX adsorbed and the cumulative amounts of CHX released, with respect to type of adhesive and saliva-coating, were analyzed using repeated-measures anova. Chlorhexidine-adsorbed orthodontic adhesives demonstrated a short-term release of CHX, which rapidly returned to near-baseline levels within 3 d. Saliva-coating did not significantly influence CHX release from RM-GIC, but increased the amount of CHX released from the composite. The amount of CHX released from the composite was 20-fold higher than that released from the RM-GIC after saliva-coating. The composite adhesive showed a greater adsorption capacity for CHX than did the RM-GIC, which was more evident after saliva-coating. This study suggests that composite adhesives may be a significantly more effective CHX reservoir than RM-GICs in the oral cavity filled with saliva.


Subject(s)
Acrylic Resins/chemistry , Aluminum Silicates/chemistry , Anti-Infective Agents, Local/administration & dosage , Chlorhexidine/administration & dosage , Dental Caries/prevention & control , Dental Pellicle/chemistry , Glass Ionomer Cements/chemistry , Orthodontic Appliances , Resin Cements/chemistry , Analysis of Variance , Anti-Infective Agents, Local/analysis , Chlorhexidine/analysis , Chromatography, High Pressure Liquid , Humans , Premedication
16.
ACS Nano ; 17(24): 24988-25004, 2023 Dec 26.
Article in English | MEDLINE | ID: mdl-38086097

ABSTRACT

Nanoplastics are a common type of contaminant in the air. However, no investigations have focused on the toxic mechanism of lung injury induced by nanoplastic exposure. In the present study, polystyrene nanoplastics (PS-NPs) caused ferroptosis in lung epithelial cells, which could be alleviated by ferrostatin-1, deferoxamine, and N-acetylcysteine. Further investigation found that PS-NPs disturbed mitochondrial structure and function and triggered autophagy. Mechanistically, oxidative stress-derived mitochondrial damage contributed to ferroptosis, and autophagy-dependent ferritinophagy was a pivotal intermediate link, resulting in ferritin degradation and iron ion release. Furthermore, inhibition of ferroptosis using ferrostatin-1 alleviated pulmonary and systemic toxicity to reverse the mouse lung injury induced by PS-NPs inhalation. Most importantly, the lung-on-a-chip was further used to clarify the role of ferroptosis in the PS-NPs-induced lung injury by visualizing the ferroptosis, oxidative stress, and alveolar-capillary barrier dysfunction at the organ level. In summary, our study indicated that ferroptosis was an important mechanism for nanoplastics-induced lung injury through different lung cells, mouse inhalation models, and three-dimensional-based lung-on-a-chip, providing an insightful reference for pulmonary toxicity assessment of nanoplastics.


Subject(s)
Ferroptosis , Lung Injury , Nanoparticles , Animals , Mice , Lung Injury/chemically induced , Polystyrenes , Microplastics , Oxidative Stress , Disease Models, Animal
17.
J Hazard Mater ; 458: 131962, 2023 09 15.
Article in English | MEDLINE | ID: mdl-37406524

ABSTRACT

Nanoplastics are prevalent in the air and can be easily inhaled, posing a threat to respiratory health. However, there have been few studies investigating the impact of nanoplastics on lung injury, especially chronic obstructive pulmonary disease (COPD). Furthermore, cell and animal models cannot deeply understand the pollutant-induced COPD. Existing lung-on-a-chip models also lack interactions among immune cells, which are crucial in monitoring complex responses. In the study, we built the lung-on-a-chip to accurately recapitulate the structural features and key functions of the alveolar-blood barrier while integrating multiple immune cells. The stability and reliability of the lung-on-a-chip model were demonstrated by toxicological application of various environmental pollutants. We Further focused on exploring the association between COPD and polystyrene nanoplastics (PS-NPs). As a result, the cell viability significantly decreased as the concentration of PS-NPs increased, while TEER levels decreased and permeability increased. Additionally, PS-NPs could induce oxidative stress and inflammatory responses at the organ level, and crossed the alveolar-blood barrier to enter the bloodstream. The expression of α1-antitrypsin (AAT) was significantly reduced, which could be served as early COPD checkpoint on the lung-chips. Overall, the lung-on-a-chip provides a new platform for investigating the pulmonary toxicity of nanoplastics, demonstrating that PS-NPs can harm the alveolar-blood barrier, cause oxidative damage and inflammation, and increase the risk of COPD.


Subject(s)
Environmental Pollutants , Lung Injury , Nanoparticles , Pulmonary Disease, Chronic Obstructive , Animals , Microplastics , Ecotoxicology , Reproducibility of Results , Lung/metabolism , Polystyrenes/toxicity , Lab-On-A-Chip Devices , Nanoparticles/chemistry
18.
JACC Case Rep ; 14: 101841, 2023 May 17.
Article in English | MEDLINE | ID: mdl-37152699

ABSTRACT

Therapeutic options for patients with isolated severe to torrential tricuspid regurgitation have been limited. Because a surgical option is often not attractive, new catheter-based therapies are emerging. We report the first-in-human percutaneous transcatheter tricuspid valve replacement with the MonarQ system in a 75-year-old female patient with severely symptomatic torrential tricuspid regurgitation. (Level of Difficulty: Advanced.).

19.
Huan Jing Ke Xue ; 44(10): 5599-5609, 2023 Oct 08.
Article in Zh | MEDLINE | ID: mdl-37827776

ABSTRACT

The biochars of WP300, WP500, and WP700 were prepared by pyrolyzing walnut green husk under 300℃, 500℃, and 700℃ with the oxygen-free condition for removing Pb2+, Cu2+, and Cd2+ in an aqueous solution. The results revealed that WP500 prepared under the medium pyrolysis temperature achieved the best adsorption performance for heavy metals, and the highest removal efficiency was reached when the solution pH was 8, in which the removal efficiency of Pb2+, Cu2+, and Cd2+ were 97.87%, 99.78%, and 71.15%, respectively. The required biochar dosage for heavy metal removal varied under different adsorption conditions. In the single-metal system, the optimal dosage for WP500 in the Pb2+, Cu2+, and Cd2+ solutions was 1.3 g·L-1, 2.1 g·L-1, and 1.9 g·L-1, respectively, whereas in the pollution metals system, the optimal biochar dosage was 5.1 g·L-1. In addition, the adsorption capacity of WP500 for the three heavy metals followed the order of Pb2+>Cu2+>Cd2+ under the single and combined-metals system, indicating that there were no synergistic or antagonistic effects among these three adsorbates. The fitting results of the adsorption isotherm model suggested that various immobilization methods existed in adsorption process between WP500 and Pb2+, Cu2+, and Cd2+. The kinetic fitting results suggested that the main reaction between WP500 and Pb2+, Cu2+, and Cd2+ was chemical adsorption. The mechanisms of WP500 for heavy metals involved pore-filling, electrostatic attraction, ion-exchange, mineral precipitation, complexation, and π-π electron donor-accepter interaction. To conclude, this study offered a new insight for the resource utilization of the waste walnut green husk.


Subject(s)
Juglans , Metals, Heavy , Water Pollutants, Chemical , Cadmium/analysis , Adsorption , Lead , Charcoal , Kinetics , Water Pollutants, Chemical/analysis
20.
Sci Rep ; 13(1): 19355, 2023 11 07.
Article in English | MEDLINE | ID: mdl-37935844

ABSTRACT

Atherosclerosis is a complex progressive disease involving intertwined biological mechanisms. We aimed to identify miRNA expression dynamics at the early stages of atherosclerosis using a large swine model (Wisconsin Miniature Swine, WMS). A total of 18 female pigs; 9 familial hypercholesterolemic (WMS-FH) and 9 normal control swine (WMS-N) were studied. miRNA sequencing was performed on plasma cell-free RNA at 3, 6, and 9 months of age. RT-qPCR validated DE miRNAs in a new cohort of animals (n = 30) with both sexes. Gene ontology and mRNA targets for DE miRNAs were identified. In vivo multimodality imaging and histopathology were performed to document the presence of atherosclerosis at termination. 20, 19, and 9 miRNAs were significantly DE between the groups at months 3, 6, and 9, respectively. Most DE miRNAs and their target genes are involved in human atherosclerosis development. Coronary atherosclerosis was documented in 7/9 WMS-FH pigs. Control animals had no lesions. miR-138, miR-152, miR-190a, and miR-196a showed a significant diagnostic power at month 3, whereas miR-486, miR-126-3p, miR-335, and miR-423-5p were of significant diagnostic power at month 9. In conclusion, specific DE miRNAs with significant discriminatory power may be promising biomarkers for the early detection of coronary atherosclerosis.


Subject(s)
Atherosclerosis , Circulating MicroRNA , Coronary Artery Disease , Hyperlipoproteinemia Type II , MicroRNAs , Humans , Male , Female , Swine , Animals , Coronary Artery Disease/genetics , MicroRNAs/metabolism , Atherosclerosis/genetics , Atherosclerosis/pathology , Biomarkers , Hyperlipoproteinemia Type II/genetics , Circulating MicroRNA/genetics , Swine, Miniature/genetics , Swine, Miniature/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL