1.
J Vasc Interv Radiol ; 33(9): 1034-1044.e29, 2022 09.
Article in English | MEDLINE | ID: mdl-35526675

ABSTRACT

PURPOSE: To assess the safety and tolerability of a vandetanib-eluting radiopaque embolic (BTG-002814) for transarterial chemoembolization (TACE) in patients with resectable liver malignancies. MATERIALS AND METHODS: The VEROnA clinical trial was a first-in-human, phase 0, single-arm, window-of-opportunity study. Eligible patients were aged ≥18 years and had resectable hepatocellular carcinoma (HCC) (Child-Pugh A) or metastatic colorectal cancer (mCRC). Patients received 1 mL of BTG-002814 transarterially (containing 100 mg of vandetanib) 7-21 days prior to surgery. The primary objectives were to establish the safety and tolerability of BTG-002814 and determine the concentrations of vandetanib and the N-desmethyl vandetanib metabolite in the plasma and resected liver after treatment. Biomarker studies included circulating proangiogenic factors, perfusion computed tomography, and dynamic contrast-enhanced magnetic resonance imaging. RESULTS: Eight patients were enrolled: 2 with HCC and 6 with mCRC. There was 1 grade 3 adverse event (AE) before surgery and 18 after surgery; 6 AEs were deemed to be related to BTG-002814. Surgical resection was not delayed. Vandetanib was present in the plasma of all patients 12 days after treatment, with a mean maximum concentration of 24.3 ng/mL (standard deviation ± 13.94 ng/mL), and in resected liver tissue up to 32 days after treatment (441-404,000 ng/g). The median percentage of tumor necrosis was 92.5% (range, 5%-100%). There were no significant changes in perfusion imaging parameters after TACE. CONCLUSIONS: BTG-002814 has an acceptable safety profile in patients before surgery. The presence of vandetanib in the tumor specimens up to 32 days after treatment suggests sustained anticancer activity, while the low vandetanib levels in the plasma suggest minimal release into the systemic circulation. Further evaluation of this TACE combination is warranted in dose-finding and efficacy studies.


Subject(s)
Carcinoma, Hepatocellular , Chemoembolization, Therapeutic , Liver Neoplasms , Adolescent , Adult , Carcinoma, Hepatocellular/drug therapy , Carcinoma, Hepatocellular/therapy , Chemoembolization, Therapeutic/adverse effects , Chemoembolization, Therapeutic/methods , Humans , Liver Neoplasms/drug therapy , Liver Neoplasms/therapy , Piperidines , Protein Kinase Inhibitors/adverse effects , Quinazolines/adverse effects , Treatment Outcome
2.
Am J Physiol Renal Physiol ; 318(3): F843-F850, 2020 03 01.
Article in English | MEDLINE | ID: mdl-32068463

ABSTRACT

End-stage kidney disease is associated with reduced exercise capacity, muscle atrophy, and impaired muscle function. While these may be improved with exercise, single modalities of exercise do not traditionally elicit improvements across all required physiological domains. Blood flow-restricted exercise may improve all of these physiological domains with low intensities traditionally considered insufficient for these adaptions. Investigation of this technique appeals, but is yet to be evaluated, in patients undergoing dialysis. With the use of a progressive crossover design, 10 satellite patients undergoing hemodialysis underwent three exercise conditions over 2 wk: two bouts (10 min) of unrestricted cycling during two consecutive hemodialysis sessions (condition 1), two bouts of cycling with blood flow restriction while off hemodialysis on 2 separate days (condition 2), and two bouts of cycling with blood flow restriction during two hemodialysis sessions (condition 3). Outcomes included hemodynamic responses (heart rate and blood pressure) throughout all sessions, participant-perceived exertion and discomfort on a Borg scale, and evaluation of ultrafiltration rates and dialysis adequacy (Kt/V) obtained post hoc. Hemodynamic responses were consistent regardless of condition. Significant increases in heart rate, systolic blood pressure, and mean arterial blood pressure (P < 0.05) were observed postexercise followed by a reduction in blood pressures during the 60-min recovery (12, 5, and 11 mmHg for systolic, diastolic, and mean arterial pressures, respectively). Blood pressures returned to predialysis ranges following the recovery period. Blood flow restriction did not affect ultrafiltration achieved or Kt/V. Hemodynamic safety and tolerability of blood flow restriction during aerobic exercise on hemodialysis is comparable to standard aerobic exercise.


Subject(s)
Blood Pressure/physiology , Exercise/physiology , Heart Rate/physiology , Kidney Failure, Chronic/therapy , Perception/physiology , Aged , Cross-Over Studies , Female , Humans , Male , Middle Aged , Regional Blood Flow/physiology
3.
J Biomed Inform ; 110: 103553, 2020 10.
Article in English | MEDLINE | ID: mdl-32891762

ABSTRACT

The development, evaluation, and eventual deployment of novel medical devices is a complex process involving various areas of expertise. Although the need for a User Centred Design approach to the development of both hardware and software has long been established, both current regulatory guidelines and widespread evaluation approaches fail to reflect the challenges encountered during day-to-day clinical practice. As such, the results from these evaluations may not provide a realistic account of the problems encountered by users when introduced to clinical practice. In this paper, we present a case study on designing the evaluation of a novel device to support laparoscopic liver surgery. Through a reflective account of the design of our usability evaluation, we identify and describe seven primary dimensions of ecological validity encountered in clinical usability evaluations. These dimensions are: 'user roles', 'environment', 'training', 'scenario', 'patient involvement', 'software', and 'hardware'. We analyse three recently published clinical usability evaluation articles to assess (and illustrate) the applicability and completeness of these dimensions. Finally, we discuss the compromises encountered during clinical usability evaluations and how to best report on these considerations. The framework presented here aims to further the agenda of ecologically valid evaluation practice, reflecting the constraints of medical practice.


Subject(s)
Software , User-Computer Interface , Humans
4.
Scand J Med Sci Sports ; 30(8): 1318-1336, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32279391

ABSTRACT

BACKGROUND: Blood flow restriction exercise has increasingly broad applications among healthy and clinical populations. Ensuring the technique is applied in a safe, controlled, and beneficial way for target populations is essential. Individualized cuff pressures are a favored method for achieving this. However, there remains marked inconsistency in how individualized cuff pressures are applied. OBJECTIVES: To quantify the cuff pressures used in the broader blood flow restriction exercise literature, and determine whether there is clear justification for the choice of pressure prescribed. METHODS: Studies were included in this review from database searches if they employed an experimental design using original data, involved either acute or chronic exercise using blood flow restriction, and they assessed limb or arterial occlusion pressure to determine an individualized cuff pressure. Methodologies of the studies were evaluated using a bespoke quality assessment tool. RESULTS: Fifty-one studies met the inclusion criteria. Individualized cuff pressures ranged from 30% to 100% arterial occlusion pressure. Only 7 out of 52 studies attempted to justify the individualized cuff pressure applied during exercise. The mean quality rating for all studies was 11.1 ± 1.2 out of 13. CONCLUSIONS: The broader blood flow restriction exercise literature uses markedly heterogeneous prescription variables despite using individualized cuff pressures. This is problematic in the absence of any clear justification for the individualized cuff pressures selected. Systematically measuring and reporting all relevant acute responses and training adaptations to the full spectrum of BFR pressures alongside increased clarity around the methodology used during blood flow restriction exercise is paramount.


Subject(s)
Muscle, Skeletal/blood supply , Pressure , Regional Blood Flow/physiology , Resistance Training/methods , Adaptation, Physiological , Humans , Tourniquets
5.
Am J Physiol Renal Physiol ; 316(5): F856-F872, 2019 05 01.
Article in English | MEDLINE | ID: mdl-30759022

ABSTRACT

Patients with end-stage kidney disease on dialysis have increased mortality and reduced physical activity, contributing to impaired physical function. Although exercise programs have demonstrated a positive effect on physiological outcomes such as cardiovascular function and strength, there is a reduced focus on physical function. The aim of this review was to determine whether exercise programs improve objective measures of physical function indicative of activities of daily living for patients with end-stage kidney disease on dialysis. A systematic search of Medline, Embase, the Cochrane Central Register of Controlled Trials, and Cumulative Index to Nursing and Allied Health Literature identified 27 randomized control trials. Only randomized control trials using an exercise intervention or significant muscular activation in the intervention, a usual care, nonexercising control group, and at least one objective measure of physical function were included. Participants were ≥18 yr of age, with end-stage kidney disease, undergoing hemo- or peritoneal dialysis. Systematic review of the literature and quality assessment of the included studies used the Cochrane Collaboration's tool for assessing risk bias. A meta-analysis was completed for the 6-min walk test. Data from 27 studies with 1,156 participants showed that exercise, regardless of modality, generally increased 6-min walk test distance, sit-to-stand time or repetitions, and grip strength as well as step and stair climb times or repetitions, dynamic mobility, and short physical performance battery scores. From the evidence available, exercise, regardless of modality, improved objective measures of physical function for end-stage kidney disease patients undergoing dialysis. It is acknowledged that further well-designed randomized control trials are required.


Subject(s)
Exercise Therapy , Kidney Failure, Chronic/therapy , Renal Dialysis , Activities of Daily Living , Adult , Aged , Aged, 80 and over , Exercise Therapy/adverse effects , Exercise Tolerance , Female , Health Status , Humans , Kidney Failure, Chronic/diagnosis , Kidney Failure, Chronic/physiopathology , Male , Middle Aged , Muscle Strength , Peritoneal Dialysis , Quality of Life , Recovery of Function , Renal Dialysis/adverse effects , Treatment Outcome
6.
BMC Nephrol ; 18(1): 294, 2017 Sep 11.
Article in English | MEDLINE | ID: mdl-28893206

ABSTRACT

BACKGROUND: Exercise during haemodialysis improves strength and physical function. However, both patients and clinicians are time poor, and current exercise recommendations add an excessive time burden making exercise a rare addition to standard care. Hypothetically, blood flow restriction exercise performed during haemodialysis can provide greater value for time spent exercising, reducing this time burden while producing similar or greater outcomes. This study will explore the efficacy of blood flow restriction exercise for enhancing strength and physical function among haemodialysis patients. METHODS: This is a randomised controlled trial design. A total of 75 participants will be recruited from haemodialysis clinics. Participants will be allocated to a blood flow restriction cycling group, traditional cycling group or usual care control group. Both exercising groups will complete 3 months of cycling exercise, performed intradialytically, three times per week. The blood flow restriction cycling group will complete two 10-min cycling bouts separated by a 20-min rest at a subjective effort of 15 on a 6 to 20 rating scale. This will be done with pressurised cuffs fitted proximally on the active limbs during exercise at 50% of a pre-determined limb occlusion pressure. The traditional cycling group will perform a continuous 20-min bout of exercise at a subjective effort of 12 on the same subjective effort scale. These workloads and volumes are equivalent and allow for comparison of a common blood flow restriction aerobic exercise prescription and a traditional aerobic exercise prescription. The primary outcome measures are lower limb strength, assessed by a three repetition maximum leg extension test, as well as objective measures of physical function: six-minute walk test, 30-s sit to stand, and timed up and go. Secondary outcome measures include thigh muscle cross sectional area, body composition, routine pathology, quality of life, and physical activity engagement. DISCUSSION: This study will determine the efficacy of blood flow restriction exercise among dialysis patients for improving key physiological outcomes that impact independence and quality of life, with reduced burden on patients. This may have broader implications for other clinical populations with similarly declining muscle health and physical function, and those contraindicated to higher intensities of exercise. TRIAL REGISTRATION: Australian and New Zealand Clinical Trial Register: ACTRN12616000121460.


Subject(s)
Blood Flow Velocity/physiology , Exercise Therapy/methods , Exercise/physiology , Kidney Failure, Chronic/therapy , Regional Blood Flow/physiology , Renal Dialysis/methods , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Kidney Failure, Chronic/physiopathology , Male , Middle Aged , Physical Fitness/physiology , Renal Dialysis/adverse effects , Young Adult
7.
Lasers Surg Med ; 48(3): 299-310, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26718623

ABSTRACT

BACKGROUND: Laparoscopic liver ablation therapy can be used for the treatment of primary and secondary liver malignancy. The increased incidence of cancer recurrence associated with this approach, has been attributed to the inability of monitoring the extent of ablated liver tissue. METHODS: The feasibility of assessing liver ablation with probe-based confocal laser endomicroscopy (CLE) was studied in a porcine model of laparoscopic microwave liver ablation. Following the intravenous injection of the fluorophores fluorescein and indocyanine green, CLE images were recorded at 488 nm and 660 nm wavelength and compared to liver histology. Statistical analysis was performed to assess if fluorescence intensity change can predict the presence of ablated liver tissue. RESULTS: CLE imaging of fluorescein at 488 nm provided good visualization of the hepatic microvasculature; whereas, CLE imaging of indocyanine green at 660 nm enabled detailed visualization of hepatic sinusoid architecture and interlobular septations. Fluorescence intensity as measured in relative fluorescence units was found to be 75-100% lower in ablated compared to healthy liver regions. General linear mixed modeling and ROC analysis found the decrease in fluorescence to be statistically significant. CONCLUSION: Laparoscopic, dual wavelength CLE imaging using two different fluorophores enables clinically useful visualization of multiple liver tissue compartments, in greater detail than is possible at a single wavelength. CLE imaging may provide valuable intraoperative information on the extent of laparoscopic liver ablation.


Subject(s)
Ablation Techniques/methods , Hepatectomy/methods , Liver/surgery , Microwaves/therapeutic use , Animals , Endoscopy , Feasibility Studies , Female , Fluorescein , Fluorescent Dyes , Indocyanine Green , Linear Models , Liver/blood supply , Liver/diagnostic imaging , Liver/pathology , Microscopy, Confocal/methods , Swine
10.
Article in English | MEDLINE | ID: mdl-38758289

ABSTRACT

PURPOSE: The recent segment anything model (SAM) has demonstrated impressive performance with point, text or bounding box prompts, in various applications. However, in safety-critical surgical tasks, prompting is not possible due to (1) the lack of per-frame prompts for supervised learning, (2) it is unrealistic to prompt frame-by-frame in a real-time tracking application, and (3) it is expensive to annotate prompts for offline applications. METHODS: We develop Surgical-DeSAM to generate automatic bounding box prompts for decoupling SAM to obtain instrument segmentation in real-time robotic surgery. We utilise a commonly used detection architecture, DETR, and fine-tuned it to obtain bounding box prompt for the instruments. We then empolyed decoupling SAM (DeSAM) by replacing the image encoder with DETR encoder and fine-tune prompt encoder and mask decoder to obtain instance segmentation for the surgical instruments. To improve detection performance, we adopted the Swin-transformer to better feature representation. RESULTS: The proposed method has been validated on two publicly available datasets from the MICCAI surgical instruments segmentation challenge EndoVis 2017 and 2018. The performance of our method is also compared with SOTA instrument segmentation methods and demonstrated significant improvements with dice metrics of 89.62 and 90.70 for the EndoVis 2017 and 2018 CONCLUSION: Our extensive experiments and validations demonstrate that Surgical-DeSAM enables real-time instrument segmentation without any additional prompting and outperforms other SOTA segmentation methods.

11.
Int J Comput Assist Radiol Surg ; 19(6): 1003-1012, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38451359

ABSTRACT

PURPOSE: Magnetic resonance (MR) imaging targeted prostate cancer (PCa) biopsy enables precise sampling of MR-detected lesions, establishing its importance in recommended clinical practice. Planning for the ultrasound-guided procedure involves pre-selecting needle sampling positions. However, performing this procedure is subject to a number of factors, including MR-to-ultrasound registration, intra-procedure patient movement and soft tissue motions. When a fixed pre-procedure planning is carried out without intra-procedure adaptation, these factors will lead to sampling errors which could cause false positives and false negatives. Reinforcement learning (RL) has been proposed for procedure plannings on similar applications such as this one, because intelligent agents can be trained for both pre-procedure and intra-procedure planning. However, it is not clear if RL is beneficial when it comes to addressing these intra-procedure errors. METHODS: In this work, we develop and compare imitation learning (IL), supervised by demonstrations of predefined sampling strategy, and RL approaches, under varying degrees of intra-procedure motion and registration error, to represent sources of targeting errors likely to occur in an intra-operative procedure. RESULTS: Based on results using imaging data from 567 PCa patients, we demonstrate the efficacy and value in adopting RL algorithms to provide intelligent intra-procedure action suggestions, compared to IL-based planning supervised by commonly adopted policies. CONCLUSIONS: The improvement in biopsy sampling performance for intra-procedure planning has not been observed in experiments with only pre-procedure planning. These findings suggest a strong role for RL in future prospective studies which adopt intra-procedure planning. Our open source code implementation is available here .


Subject(s)
Image-Guided Biopsy , Prostatic Neoplasms , Humans , Male , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Prostatic Neoplasms/surgery , Image-Guided Biopsy/methods , Magnetic Resonance Imaging/methods , Prostate/diagnostic imaging , Prostate/pathology , Prostate/surgery , Ultrasonography, Interventional/methods , Machine Learning
12.
Int J Comput Assist Radiol Surg ; 19(6): 1053-1060, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38528306

ABSTRACT

PURPOSE: Endoscopic pituitary surgery entails navigating through the nasal cavity and sphenoid sinus to access the sella using an endoscope. This procedure is intricate due to the proximity of crucial anatomical structures (e.g. carotid arteries and optic nerves) to pituitary tumours, and any unintended damage can lead to severe complications including blindness and death. Intraoperative guidance during this surgery could support improved localization of the critical structures leading to reducing the risk of complications. METHODS: A deep learning network PitSurgRT is proposed for real-time localization of critical structures in endoscopic pituitary surgery. The network uses high-resolution net (HRNet) as a backbone with a multi-head for jointly localizing critical anatomical structures while segmenting larger structures simultaneously. Moreover, the trained model is optimized and accelerated by using TensorRT. Finally, the model predictions are shown to neurosurgeons, to test their guidance capabilities. RESULTS: Compared with the state-of-the-art method, our model significantly reduces the mean error in landmark detection of the critical structures from 138.76 to 54.40 pixels in a 1280 × 720-pixel image. Furthermore, the semantic segmentation of the most critical structure, sella, is improved by 4.39% IoU. The inference speed of the accelerated model achieves 298 frames per second with floating-point-16 precision. In the study of 15 neurosurgeons, 88.67% of predictions are considered accurate enough for real-time guidance. CONCLUSION: The results from the quantitative evaluation, real-time acceleration, and neurosurgeon study demonstrate the proposed method is highly promising in providing real-time intraoperative guidance of the critical anatomical structures in endoscopic pituitary surgery.


Subject(s)
Endoscopy , Pituitary Neoplasms , Humans , Endoscopy/methods , Pituitary Neoplasms/surgery , Surgery, Computer-Assisted/methods , Deep Learning , Pituitary Gland/surgery , Pituitary Gland/anatomy & histology , Pituitary Gland/diagnostic imaging , Sphenoid Sinus/surgery , Sphenoid Sinus/anatomy & histology , Sphenoid Sinus/diagnostic imaging
13.
Med Image Anal ; 95: 103181, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38640779

ABSTRACT

Supervised machine learning-based medical image computing applications necessitate expert label curation, while unlabelled image data might be relatively abundant. Active learning methods aim to prioritise a subset of available image data for expert annotation, for label-efficient model training. We develop a controller neural network that measures priority of images in a sequence of batches, as in batch-mode active learning, for multi-class segmentation tasks. The controller is optimised by rewarding positive task-specific performance gain, within a Markov decision process (MDP) environment that also optimises the task predictor. In this work, the task predictor is a segmentation network. A meta-reinforcement learning algorithm is proposed with multiple MDPs, such that the pre-trained controller can be adapted to a new MDP that contains data from different institutes and/or requires segmentation of different organs or structures within the abdomen. We present experimental results using multiple CT datasets from more than one thousand patients, with segmentation tasks of nine different abdominal organs, to demonstrate the efficacy of the learnt prioritisation controller function and its cross-institute and cross-organ adaptability. We show that the proposed adaptable prioritisation metric yields converging segmentation accuracy for a new kidney segmentation task, unseen in training, using between approximately 40% to 60% of labels otherwise required with other heuristic or random prioritisation metrics. For clinical datasets of limited size, the proposed adaptable prioritisation offers a performance improvement of 22.6% and 10.2% in Dice score, for tasks of kidney and liver vessel segmentation, respectively, compared to random prioritisation and alternative active sampling strategies.


Subject(s)
Algorithms , Humans , Tomography, X-Ray Computed , Neural Networks, Computer , Machine Learning , Markov Chains , Supervised Machine Learning , Radiography, Abdominal/methods
14.
Proc SPIE Int Soc Opt Eng ; 124662023 Feb 23.
Article in English | MEDLINE | ID: mdl-36923061

ABSTRACT

Depth perception is a major issue in surgical augmented reality (AR) with limited research conducted in this scientific area. This study establishes a relationship between luminance and depth perception. This can be used to improve visualisation design for AR overlay in laparoscopic surgery, providing surgeons a more accurate perception of the anatomy intraoperatively. Two experiments were conducted to determine this relationship. First, an online study with 59 participants from the general public, and second, an in-person study with 10 surgeons as participants. We developed 2 open-source software tools utilising SciKit-Surgery libraries to enable these studies and any future research. Our findings demonstrate that the higher the relative luminance, the closer a structure is perceived to the operating camera. Furthermore, the higher the luminance contrast between the two structures, the higher the depth distance perceived. The quantitative results from both experiments are in agreement, indicating that online recruitment of the general public can be helpful in similar studies. An observation made by the surgeons from the in-person study was that the light source used in laparoscopic surgery plays a role in depth perception. This is due to its varying positioning and brightness which could affect the perception of the overlaid AR. We found that luminance directly correlates with depth perception for both surgeons and the general public, regardless of other depth cues. Future research may focus on comparing different colours used in surgical AR and using a mock operating room (OR) with varying light sources and positions.

15.
Comput Graph Forum ; 42(6): e14793, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37915466

ABSTRACT

Designing realistic digital humans is extremely complex. Most data-driven generative models used to simplify the creation of their underlying geometric shape do not offer control over the generation of local shape attributes. In this paper, we overcome this limitation by introducing a novel loss function grounded in spectral geometry and applicable to different neural-network-based generative models of 3D head and body meshes. Encouraging the latent variables of mesh variational autoencoders (VAEs) or generative adversarial networks (GANs) to follow the local eigenprojections of identity attributes, we improve latent disentanglement and properly decouple the attribute creation. Experimental results show that our local eigenprojection disentangled (LED) models not only offer improved disentanglement with respect to the state-of-the-art, but also maintain good generation capabilities with training times comparable to the vanilla implementations of the models. Our code and pre-trained models are available at github.com/simofoti/LocalEigenprojDisentangled.

16.
Article in English | MEDLINE | ID: mdl-37525696

ABSTRACT

It is important to understand how to design AR content for surgical contexts to mitigate the risk of distracting the surgeons. In this work, we test information overlays for AR guidance during keyhole surgery. We performed a preliminary evaluation of a prototype, focusing on the effects of colour, opacity, and information representation. Our work contributes insights into the design of AR guidance in surgery settings and a foundation for future research on visualisation design for surgical AR.

17.
Front Surg ; 10: 1222859, 2023.
Article in English | MEDLINE | ID: mdl-37780914

ABSTRACT

Background: Endoscopic endonasal surgery is an established minimally invasive technique for resecting pituitary adenomas. However, understanding orientation and identifying critical neurovascular structures in this anatomically dense region can be challenging. In clinical practice, commercial navigation systems use a tracked pointer for guidance. Augmented Reality (AR) is an emerging technology used for surgical guidance. It can be tracker based or vision based, but neither is widely used in pituitary surgery. Methods: This pre-clinical study aims to assess the accuracy of tracker-based navigation systems, including those that allow for AR. Two setups were used to conduct simulations: (1) the standard pointer setup, tracked by an infrared camera; and (2) the endoscope setup that allows for AR, using reflective markers on the end of the endoscope, tracked by infrared cameras. The error sources were estimated by calculating the Euclidean distance between a point's true location and the point's location after passing it through the noisy system. A phantom study was then conducted to verify the in-silico simulation results and show a working example of image-based navigation errors in current methodologies. Results: The errors of the tracked pointer and tracked endoscope simulations were 1.7 and 2.5 mm respectively. The phantom study showed errors of 2.14 and 3.21 mm for the tracked pointer and tracked endoscope setups respectively. Discussion: In pituitary surgery, precise neighboring structure identification is crucial for success. However, our simulations reveal that the errors of tracked approaches were too large to meet the fine error margins required for pituitary surgery. In order to achieve the required accuracy, we would need much more accurate tracking, better calibration and improved registration techniques.

18.
IEEE Trans Biomed Eng ; PP2023 Oct 19.
Article in English | MEDLINE | ID: mdl-37856260

ABSTRACT

OBJECTIVE: Reconstructing freehand ultrasound in 3D without any external tracker has been a long-standing challenge in ultrasound-assisted procedures. We aim to define new ways of parameterising long-term dependencies, and evaluate the performance. METHODS: First, long-term dependency is encoded by transformation positions within a frame sequence. This is achieved by combining a sequence model with a multi-transformation prediction. Second, two dependency factors are proposed, anatomical image content and scanning protocol, for contributing towards accurate reconstruction. Each factor is quantified experimentally by reducing respective training variances. RESULTS: 1) The added long-term dependency up to 400 frames at 20 frames per second (fps) indeed improved reconstruction, with an up to 82.4% lowered accumulated error, compared with the baseline performance. The improvement was found to be dependent on sequence length, transformation interval and scanning protocol and, unexpectedly, not on the use of recurrent networks with long-short term modules; 2) Decreasing either anatomical or protocol variance in training led to poorer reconstruction accuracy. Interestingly, greater performance was gained from representative protocol patterns, than from representative anatomical features. CONCLUSION: The proposed algorithm uses hyperparameter tuning to effectively utilise long-term dependency. The proposed dependency factors are of practical significance in collecting diverse training data, regulating scanning protocols and developing efficient networks. SIGNIFICANCE: The proposed new methodology with publicly available volunteer data and code for parametersing the long-term dependency, experimentally shown to be valid sources of performance improvement, which could potentially lead to better model development and practical optimisation of the reconstruction application.

19.
Med Image Anal ; 90: 102943, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37703675

ABSTRACT

Augmented Reality (AR) is considered to be a promising technology for the guidance of laparoscopic liver surgery. By overlaying pre-operative 3D information of the liver and internal blood vessels on the laparoscopic view, surgeons can better understand the location of critical structures. In an effort to enable AR, several authors have focused on the development of methods to obtain an accurate alignment between the laparoscopic video image and the pre-operative 3D data of the liver, without assessing the benefit that the resulting overlay can provide during surgery. In this paper, we present a study that aims to assess quantitatively and qualitatively the value of an AR overlay in laparoscopic surgery during a simulated surgical task on a phantom setup. We design a study where participants are asked to physically localise pre-operative tumours in a liver phantom using three image guidance conditions - a baseline condition without any image guidance, a condition where the 3D surfaces of the liver are aligned to the video and displayed on a black background, and a condition where video see-through AR is displayed on the laparoscopic video. Using data collected from a cohort of 24 participants which include 12 surgeons, we observe that compared to the baseline, AR decreases the median localisation error of surgeons on non-peripheral targets from 25.8 mm to 9.2 mm. Using subjective feedback, we also identify that AR introduces usability improvements in the surgical task and increases the perceived confidence of the users. Between the two tested displays, the majority of participants preferred to use the AR overlay instead of navigated view of the 3D surfaces on a separate screen. We conclude that AR has the potential to improve performance and decision making in laparoscopic surgery, and that improvements in overlay alignment accuracy and depth perception should be pursued in the future.


Subject(s)
Augmented Reality , Laparoscopy , Surgery, Computer-Assisted , Humans , Imaging, Three-Dimensional/methods , Laparoscopy/methods , Liver/diagnostic imaging , Liver/surgery , Surgery, Computer-Assisted/methods
20.
Med Phys ; 50(5): 2695-2704, 2023 May.
Article in English | MEDLINE | ID: mdl-36779419

ABSTRACT

BACKGROUND: Accurate camera and hand-eye calibration are essential to ensure high-quality results in image-guided surgery applications. The process must also be able to be undertaken by a nonexpert user in a surgical setting. PURPOSE: This work seeks to identify a suitable method for tracked stereo laparoscope calibration within theater. METHODS: A custom calibration rig, to enable rapid calibration in a surgical setting, was designed. The rig was compared against freehand calibration. Stereo reprojection, stereo reconstruction, tracked stereo reprojection, and tracked stereo reconstruction error metrics were used to evaluate calibration quality. RESULTS: Use of the calibration rig reduced mean errors: reprojection (1.47 mm [SD 0.13] vs. 3.14 mm [SD 2.11], p-value 1e-8), reconstruction (1.37 px [SD 0.10] vs. 10.10 px [SD 4.54], p-value 6e-7), and tracked reconstruction (1.38 mm [SD 0.10] vs. 12.64 mm [SD 4.34], p-value 1e-6) compared with freehand calibration. The use of a ChArUco pattern yielded slightly lower reprojection errors, while a dot grid produced lower reconstruction errors and was more robust under strong global illumination. CONCLUSION: The use of the calibration rig results in a statistically significant decrease in calibration error metrics, versus freehand calibration, and represents the preferred approach for use in the operating theater.


Subject(s)
Calibration , Image Processing, Computer-Assisted , Laparoscopes , Laparoscopes/standards , Laparoscopy/instrumentation , Data Accuracy , Optical Devices/standards
SELECTION OF CITATIONS