ABSTRACT
PURPOSE: This study evaluates the benefit of a virtual bolus method for volumetric modulated arc therapy (VMAT) plan optimization to compensate breast modifications that may occur during breast treatment. METHODS: Ten files were replanned with VMAT giving 50 Gy to the breast and 47 Gy to the nodes within 25 fractions. The planning process used a virtual bolus for the first optimization, then the monitors units were reoptimized without bolus, after fixing the segments shapes. Structures and treatment planning were exported on a second scanner (CT) performed during treatment as a consequence to modifications in patient's anatomy. The comparative end-point was clinical target volume's coverage. The first analysis compared the VMAT plans made using the virtual bolus method (VB-VMAT) to the plans without using it (NoVB-VMAT) on the first simulation CT. Then, the same analysis was performed on the second CT. Finally, the level of degradation of target volume coverage between the two CT using VB-VMAT was compared to results using a standard technique of forward-planned multisegment technique (Tan-IMRT). RESULTS: Using a virtual bolus for VMAT does not degrade dosimetric results on the first CT. No significant result in favor of the NoVB-VMAT plans was noted. The VB-VMAT method led to significant better dose distribution on a second CT with modified anatomies compared to NoVB-VMAT. The clinical target volume's coverage by 95% (V95%) of the prescribed dose was 98.9% [96.1-99.6] on the second CT for VB-VMAT compared to 92.6% [85.2-97.7] for NoVB-VMAT (P = 0.0002). The degradation of the target volume coverage for VB-VMAT is not worse than for Tan-IMRT: the median differential of V95% between the two CT was 0.9% for VMAT and 0.7% for Tan-IMRT (P = 1). CONCLUSION: This study confirms the safety and benefit of using a virtual bolus during the VMAT planning process to compensate potential breast shape modifications.
Subject(s)
Breast Neoplasms/radiotherapy , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Unilateral Breast NeoplasmsABSTRACT
Objective. Optical fiber-based scintillating dosimetry is a recent promising technique owing to the miniature size dosimeter and quality measurement in modern radiation therapy treatment. Despite several advantages, the major issue of using scintillating dosimeters is the Cerenkov effect and predominantly requires extra measurement corrections. Therefore, this work highlighted a novel micro-dosimetry technique to ensure Cerenkov-free measurement in radiation therapy treatment protocol by investigating several dosimetric characteristics.Approach.A micro-dosimetry technique was proposed with the performance evaluation of a novel infrared inorganic scintillator detector (IR-ISD). The detector essentially consists of a micro-scintillating head based on IR-emitting micro-clusters with a sensitive volume of 1.5 × 10-6mm3. The proposed system was evaluated under the 6 MV LINAC beam used in patient treatment. Overall measurements were performed using IBATMwater tank phantoms by following TRS-398 protocol for radiotherapy. Cerenkov measurements were performed for different small fields from 0.5 × 0.5 cm2to 10 × 10 cm2under LINAC. In addition, several dosimetric parameters such as percentage depth dose (PDD), high lateral resolution beam profiling, dose linearity, dose rate linearity, repeatability, reproducibility, and field output factor were investigated to realize the performance of the novel detector.Main results. This study highlighted a complete removal of the Cerenkov effect using a point-like miniature detector, especially for small field radiation therapy treatment. Measurements demonstrated that IR-ISD has acceptable behavior with dose rate variability (maximum standard deviation â¼0.18%) for the dose rate of 20-1000 cGy s-1. An entire linear response (R2= 1) was obtained for the dose delivered within the range of 4-1000 cGy, using a selected field size of 1 × 1 cm2. Perfect repeatability (max 0.06% variation from average) with day-to-day reproducibility (0.10% average variation) was observed. PDD profiles obtained in the water tank present almost identical behavior to the reference dosimeter with a build-up maximum depth dose at 1.5 cm. The small field of 0.5 × 0.5 cm2profiles have been characterized with a high lateral resolution of 100µm.Significance. Unlike recent plastic scintillation detector systems, the proposed micro-dosimetry system in this study requires no Cerenkov corrections and showed efficient performance for several dosimetric parameters. Therefore, it is expected that considering the detector correction factors, the IR-ISD system can be a suitable dose measurement tool, such as in small-field dose measurements, high and low gradient dose verification, and, by extension, in microbeam radiation and FLASH radiation therapy.
Subject(s)
Radiometry , Radiometry/instrumentation , Radiometry/methods , Phantoms, Imaging , Radiotherapy Dosage , Microtechnology/instrumentation , Humans , Scintillation Counting/instrumentationABSTRACT
BACKGROUND: An incidental axillary dose of adjuvant radiotherapy using tangential beams is usually given after breast-conserving surgery for breast cancer. The goal of this sub-study was to evaluate this incidental dose in the setting of post-mastectomy radiotherapy (PMRT) according to two different radiotherapy techniques. METHODS: Patients participating in a randomized SERC trial who received PMRT in a single center were included. We collected the incidental axillary dose delivered to the Berg level 1 using different dosimetric parameters and compared two techniques using Student's t-test: three-dimensional conformal radiotherapy (3D-CRT) and volumetric arc therapy (VMAT). RESULTS: We analyzed radiotherapy plans from 52 patients who received PMRT from 2012 to 2021. The mean dose delivered to the Berg level 1 was 37.2 Gy. It was significantly higher with VMAT than with 3D-CRT-43.6 Gy (SD = 3.1 Gy) versus 34.8 Gy (SD = 8.6 Gy) p < 0.001. Eighty-four percent of the Berg level 1 was covered by 40 Gy isodose in the VMAT group versus 55.5% in the 3D-CRT group p < 0.001. CONCLUSIONS: On the Berg level 1, PMRT gives a dose at least equivalent to the one given by post-breast-conserving surgery radiotherapy, making it possible to limit completion axillary lymph node dissections in select pN1a patients treated with a mastectomy. Modern radiotherapy techniques like VMAT tend to increase this incidental dose.
ABSTRACT
Objective: To determine the MRI-Linac added value over conventional image-guided radiation therapy (IGRT) in liver tumors Stereotactic ablative radiation therapy (SABR). Materials and methods: We retrospectively compared the Planning Target Volumes (PTVs), the spared healthy liver parenchyma volumes, the Treatment Planning System (TPS) and machine performances, and the patients' outcomes when using either a conventional accelerator (Versa HD®, Elekta, Utrecht, NL) with Cone Beam CT as the IGRT tool or an MR-Linac system (MRIdian®, ViewRay, CA). Results: From November 2014 to February 2020, 59 patients received a SABR treatment (45 and 19 patients in the Linac and MR-Linac group, respectively) for 64 primary or secondary liver tumors. The mean tumor size was superior in the MR-Linac group (37,91cc vs. 20.86cc). PTV margins led to a median 74%- and 60% increase in target volume in Linac-based and MRI-Linac-based treatments, respectively. Liver tumor boundaries were visible in 0% and 72% of the cases when using CBCT and MRI as IGRT tools, respectively. The mean prescribed dose was similar in the two patient groups. Local tumor control was 76.6%, whereas 23.4% of patients experienced local progression (24.4% and 21.1% of patients treated on the conventional Linac and the MRIdian system, respectively). SABR was well tolerated in both groups, and margins reduction and the use of gating prevented ulcerous disease occurrence. Conclusion: The use of MRI as IGRT allows for the reduction of the amount of healthy liver parenchyma irradiated without any decrease of the tumor control rate, which would be helpful for dose escalation or subsequent liver tumor irradiation if needed.
ABSTRACT
This study exposed the implementation of a novel technique (VMATLSL) for the planning of moving targets in lung stereotactic body radiation therapy (SBRT). This new technique has been compared to static conformal radiotherapy (3D-CRT), volumetric-modulated arc therapy (VMAT) and dynamic conformal arc (DCA). The rationale of this study was to lower geometric complexity (54.9% lower than full VMAT) and hence ensure the reproducibility of the treatment delivery by reducing the risk for interplay errors induced by respiratory motion. Dosimetry metrics were studied with a cohort of 30 patients. Our results showed that leaf speed limitation provided conformal number (CN) close to the VMAT (median CN of VMATLSL is 0.78 vs 0.82 for full VMAT) and were a significant improvement on 3D-CRT and DCA with segment-weight optimized (respectively 0.55 and 0.57). This novel technique is an alternative to VMAT or DCA for lung SBRT treatments, combining independence from the patient's breathing pattern, from the size and amplitude of the lesion, free from interplay effect and with dosimetry metrics close to the best that could be achieve with full VMAT.
ABSTRACT
Stereotactic body radiotherapy (SBRT) and percutaneous thermal ablation (TA) are alternatives to surgery for the management of pulmonary oligometastases. In this collaborative work, we retrospectively analyzed patients who had undergone iterative focal ablative treatments of pulmonary oligometastases. We hypothesized that repeated ablative therapies could benefit patients with consecutive oligometastatic relapses. Patients treated with SBRT and/or TA for pulmonary oligometastases in two French academic centers between October 2011 and November 2016 were included. A total of 102 patients with 198 lesions were included; 45 patients (44.1%) received repeated focal treatments at the pulmonary site for an oligorecurrent disease (the "multiple courses" group). Median follow-up was 22.5 months. The 3-year overall survival rates of patients who had a single treatment sequence (the "single course" group) versus the "multiple courses" were 73.9% and 78.8%, respectively, which was not a statistically significant difference (p = 0.860). The 3-year systemic therapy-free survival tended to be longer in the "multiple courses" group (50.4%) than in the "single course" group (44.7%) (p = 0.081). Tolerance of repeated treatments was excellent with only one grade 4 toxicity. Thereby, multimodality repeated ablative therapy is effective in patients with pulmonary oligorecurrent metastases. This strategy may delay the use of more toxic systemic therapy.
Subject(s)
Lung Neoplasms , Radiosurgery , Combined Modality Therapy , Humans , Lung Neoplasms/pathology , Neoplasm Recurrence, Local , Radiosurgery/adverse effects , Retrospective StudiesABSTRACT
PURPOSE: In modern radiotherapy techniques, to ensure an accurate beam modeling process, dosimeters with high accuracy and spatial resolution are required. Therefore, this work aims to propose a simple, robust, and a small-scale fiber-integrated X-ray inorganic detector and investigate the dosimetric characteristics used in radiotherapy. METHODS: The detector is based on red-emitting silver-activated zinc-cadmium sulfide (Zn,Cd)S:Ag nanoclusters and the proposed system has been tested under 6 MV photons with standard dose rate used in the patient treatment protocol. The article presents the performances of the detector in terms of dose linearity, repeatability, reproducibility, percentage depth dose distribution, and field output factor. A comparative study is shown using a microdiamond dosimeter and considering data from recent literature. RESULTS: We accurately measured a small field beam profile of 0.5 × 0.5 cm2 at a spatial resolution of 100 µm using a LINAC system. The dose linearity at 400 MU/min has shown less than 0.53% and 1.10% deviations from perfect linearity for the regular and smallest field. Percentage depth dose measurement agrees with microdiamond measurements within 1.30% and 2.94%, respectively for regular to small field beams. Besides, the stem effect analysis shows a negligible contribution in the measurements for fields smaller than 3x3 cm2. This study highlights the drastic decrease of the convolution effect using a point-like detector, especially in small dimension beam characterization. Field output factor has shown a good agreement while comparing it with the microdiamond dosimeter. CONCLUSION: All the results presented here anticipated that the developed detector can accurately measure delivered dose to the region of interest, claim accurate depth dose distribution hence it can be a suitable candidate for beam characterization and quality assurance of LINAC system.
Subject(s)
Cadmium , Silver , Humans , Photons , Radiometry , Reproducibility of Results , ZincABSTRACT
PURPOSE: Brachytherapy (BT) deals with high gradient internal dose irradiation made up of a complex system where the source is placed nearby the tumor to destroy cancerous cells. A primary concern of clinical safety in BT is quality assurance to ensure the best matches between the delivered and prescribed doses targeting small volume tumors and sparing surrounding healthy tissues. Hence, the purpose of this study is to evaluate the performance of a point size inorganic scintillator detector (ISD) in terms of high dose rate brachytherapy (HDR-BT) treatment. METHODS: A prototype of the dose verification system has been developed based on scintillating dosimetry to measure a high dose rate while using an 192 Ir BT source. The associated dose rate is measured in photons/s employing a highly sensitive photon counter (design data: 20 photons/s). Dose measurement was performed as a function of source-to-detector distance according to TG43U1 recommendations. Overall measurements were carried out inside water phantoms keeping the ISD along the BT needle; a minimum of 0.1 cm distance was maintained between each measurement point. The planned dwell times were measured accurately from the difference of two adjacent times of transit. The ISD system performances were also evaluated in terms of dose linearity, energy dependency, scintillation stability, signal-to-noise ratio (SNR), and signal-to-background ratio (SBR). Finally, a comparison was presented between the ISD measurements and results obtained from TG43 reference dataset. RESULTS: The detection efficiency of the ISD was verified by measuring the planned dwell times at different dwell positions. Measurements demonstrated that the ISD has a perfectly linear behavior with dose rate (R2 = 1) and shows high SNR (>35) and SBR (>36) values even at the lowest dose rate investigated at around 10 cm from the source. Standard deviation (1σ) remains within 0.03% of signal magnitude, and less than 0.01% STEM signal was monitored at 0.1 cm source-to-detector distance. Stability of 0.54% is achieved, and afterglow stays less than 1% of the total signal in all the irradiations. Excellent symmetrical behavior of the dose rate regarding source position was observed at different radiation planes. Finally, a comparison with TG-43 reference dataset shows that corrected measurements agreed with simulation data within 1.2% and 1.3%, and valid for the source-to-detector distance greater than 0.25 cm. CONCLUSION: The proposed ISD in this study anticipated that the system could be promoted to validate with further clinical investigations. It allows an appropriate dose verification with dwell time estimation during source tracking and suitable dose measurement with a high spatial resolution both nearby (high dose gradient) and far (low dose gradient) from the source position.
Subject(s)
Brachytherapy , Iridium Radioisotopes , Needles , Phantoms, Imaging , Radiometry , Radiotherapy Dosage , Signal-To-Noise RatioABSTRACT
PURPOSE: Small field dosimetry for radiotherapy is one of the major challenges due to the size of most dosimeters, for example, sufficient spatial resolution, accurate dose distribution and energy dependency of the detector. In this context, the purpose of this research is to develop a small size scintillating detector targeting small field dosimetry and compare its performance with other commercial detectors. METHOD: An inorganic scintillator detector (ISD) of about 200 µm outer diameter was developed and tested through different small field dosimetric characterizations under high-energy photons (6 and 15 MV) delivered by an Elekta Linear Accelerator (LINAC). Percentage depth dose (PDD) and beam profile measurements were compared using dosimeters from PTW namely, microdiamond and PinPoint three-dimensional (PP3D) detector. A background fiber method has been considered to quantitate and eliminate the minimal Cerenkov effect from the total optical signal magnitude. Measurements were performed inside a water phantom under IAEA Technical Reports Series recommendations (IAEA TRS 381 and TRS 483). RESULTS: Small fields ranging from 3 × 3 cm2 , down to 0.5 × 0.5 cm2 were sequentially measured using the ISD and commercial dosimeters, and a good agreement was obtained among all measurements. The result also shows that, scintillating detector has good repeatability and reproducibility of the output signal with maximum deviation of 0.26% and 0.5% respectively. The Full Width Half Maximum (FWHM) was measured 0.55 cm for the smallest available square size field of 0.5 × 0.5 cm2 , where the discrepancy of 0.05 cm is due to the scattering effects inside the water and convolution effect between field and detector geometries. Percentage depth dose factor dependence variation with water depth exhibits nearly the same behavior for all tested detectors. The ISD allows to perform dose measurements at a very high accuracy from low (50 cGy/min) to high dose rates (800 cGy/min) and was found to be independent of dose rate variation. The detection system also showed an excellent linearity with dose; hence, calibration was easily achieved. CONCLUSIONS: The developed detector can be used to accurately measure the delivered dose at small fields during the treatment of small volume tumors. The author's measurement shows that despite using a nonwater-equivalent detector, the detector can be a powerful candidate for beam characterization and quality assurance in, for example, radiosurgery, Intensity-Modulated Radiotherapy (IMRT), and brachytherapy. Our detector can provide real-time dose measurement and good spatial resolution with immediate readout, simplicity, flexibility, and robustness.
Subject(s)
Inorganic Chemicals , Scintillation Counting/methods , Linear Models , Signal-To-Noise Ratio , X-RaysABSTRACT
BACKGROUND/AIM: Radiological evaluation after stereotactic-body-radiotherapy (SBRT) for non-small-cell lung carcinoma (NSCLC) is often difficult due to lung radiation-induced image modifications on computed tomographic (CT) scan. The aim of this study was to evaluate positron-emission tomography-computed tomography (PET-CT) using fluorodeoxyglucose after SBRT in primary lung cancer. PATIENTS AND METHODS: Eighteen patients with histologically proven NSCLC were treated with SBRT. All had PET-CT evaluations before treatment, at 2 to 3 months and at 1 year post SBRT during the follow-up. RESULTS: Early PET-CT in 12/18 patients who did not experience local failure did not show any progression. No conclusion could be drawn in four cases because early PET-CT was disturbed by inflammatory reaction. Early PET-CT was not predictive of late outcome for two patients, as it showed a significant response followed by disease progression on late evaluation. CONCLUSION: Early PET response appears to correlate with local control at 1 year post SBRT.
Subject(s)
Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/radiotherapy , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/drug therapy , Positron Emission Tomography Computed Tomography/methods , Radiosurgery/methods , Aged , Aged, 80 and over , Carcinoma, Non-Small-Cell Lung/pathology , Female , Humans , Lung Neoplasms/pathology , Male , Middle Aged , Neoplasm Staging , Outcome Assessment, Health Care/methods , Prognosis , Reproducibility of Results , Time FactorsABSTRACT
BACKGROUND/AIM: To assess the clinical impact of high dose rate stereotactic body radiation therapy (SBRT) in patients with lung neoplastic lesions. PATIENTS AND METHODS: From January 2014 to June 2016, a single-center retrospective analysis was performed including all patients treated by either flattening filter free (FFF) beams or flattening filter beams (FF) three-dimensional (3D) SBRT for lung neoplastic lesions. RESULTS: A total of 99 SBRT were performed on 75 patients. Among these, 29 SBRT were performed using a FFF technique while 70 other SBRT were done using a FF technique. Median follow-up time was 12.9 months. Overall, no difference between the two groups was found except for the mean beam on time which was reduced by 3.3 to 0.9 minutes in the FFF group (p<0.001). CONCLUSION: We report a low toxicity rate and a shortened beam on time in patients treated with 3D FFF SBRT for lung neoplastic lesions.
Subject(s)
Carcinoma, Non-Small-Cell Lung/radiotherapy , Lung Neoplasms/radiotherapy , Radiosurgery/methods , Adenocarcinoma/pathology , Adenocarcinoma/radiotherapy , Adult , Aged , Aged, 80 and over , Carcinoma, Non-Small-Cell Lung/pathology , Colonic Neoplasms/pathology , Colonic Neoplasms/radiotherapy , Endometrial Neoplasms/pathology , Endometrial Neoplasms/radiotherapy , Female , Humans , Lung Neoplasms/pathology , Male , Middle Aged , Neoplasm Staging , Sarcoma/pathology , Sarcoma/radiotherapyABSTRACT
Automated atlas-based segmentation (ABS) algorithms present the potential to reduce the variability in volume delineation. Several vendors offer software that are mainly used for cranial, head and neck, and prostate cases. The present study will compare the contours produced by a radiation oncologist to the contours computed by different automated ABS algorithms for prostate bed cases, including femoral heads, bladder, and rectum. Contour comparison was evaluated by different metrics such as volume ratio, Dice coefficient, and Hausdorff distance. Results depended on the volume of interest showed some discrepancies between the different software. Automatic contours could be a good starting point for the delineation of organs since efficient editing tools are provided by different vendors. It should become an important help in the next few years for organ at risk delineation.