1.
J Cardiovasc Electrophysiol ; 34(2): 315-324, 2023 02.
Article in English | MEDLINE | ID: mdl-36511472

ABSTRACT

INTRODUCTION: Visually-guided laser balloon ablation (VGLA) currently requires careful manual rotation of the laser to create overlapping lesions. A novel semi-automated VGLA may reduce ablation times and lesion gaps. We aimed to compare semi-automated (SA) VGLA to that of manual (MN) VGLA. METHODS: Acute: Nine swine underwent right superior pulmonary vein isolation (PVI) using either SA (n = 3, 13-18 W), MN (n = 3, 8.5-12 W), or radiofrequency (RF, n = 3, 25-40 W) and were killed acutely. Chronic: 16 swine, underwent PVI using either SA (n = 8, 15 W) or MN (n = 8, 10 W), and were survived for 1 month before being killed. All hearts were then submitted for pathological evaluation. RESULTS: Acute: PVI was successful in all 9/9 swine with lesion counts significantly lower in the SA arm (5.3 ± 5.9, 33.7 ± 10.0, and 28.0 ± 4.4 in SA, MN, and RF arms; p = .007 for SA and MN). At necropsy, circumferentiality and transmurality were 98% and 94% in SA, 98% and 80% in MN, and 100% and 100% in RF arms. A single steam pop was noted on sectioning in the SA arm swine and occurred in the high dose (18 W) strategy. Chronic: PVI was acutely successful in 16/16 swine with no difference in PVI durability rates (62.5% vs. 75.0%), lesion transmurality (95.8 ± 17.4% vs.91.9 ± 25.9%), and circumferentiality (95.8 ± 6.6% vs. 94.8 ± 6.3%) between SA and MN arms. Catheter use time and lesion counts were lower in the SA arm compared to the MN arm (11.5 ± 12.7 vs. 21.8 ± 3.8 min, p = .046 and 4.8 ± 3.83 vs. 35.4 ± 4.4, p < .001). CONCLUSION: Motor-assisted semi-automated laser balloon ablation can improve upon procedural efficiency by reducing ablation time.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Laser Therapy , Pulmonary Veins , Swine , Animals , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Pulmonary Veins/surgery , Treatment Outcome , Catheter Ablation/adverse effects , Laser Therapy/adverse effects
2.
J Cardiovasc Electrophysiol ; 34(5): 1277-1285, 2023 05.
Article in English | MEDLINE | ID: mdl-36950852

ABSTRACT

INTRODUCTION: Multiple randomized controlled trials have demonstrated sodium-glucose cotransporter-2 inhibitors (SGLT2i) decrease the composite endpoint of cardiovascular death or heart failure hospitalizations in all heart failure patients. It is uncertain whether SGLT2i impacts the risk of sudden cardiac death in patients with heart failure. METHODS: A comprehensive search was performed to identify relevant data published before August 28, 2022. Trials were included if: (1) all patients had clinical heart failure (2) SGLT2i and placebo were compared (3) all patients received conventional medical therapy and (4) reported outcomes of interest (sudden cardiac death [SCD], ventricular arrhythmias, atrial arrhythmias). RESULTS: SCD was reported in seven of the eleven trials meeting selection criteria: 10 796 patients received SGLT2i and 10 796 received placebo. SGLT2i therapy was associated with a significant reduction in the risk of SCD (risk ratios [RR]: 0.68; 95% confidence intervals [CI]: 0.48-0.95; p = .03; I2 = 0%). Absent dedicated rhythm monitoring, there were no significant differences in the incidence of sustained ventricular arrhythmias not associated with SCD (RR: 1.03; 95% CI: 0.83-1.29; p = .77; I2 = 0%) or atrial arrhythmias (RR: 0.91; 95% CI: 0.77-1.09; p = .31; I2 = 29%) between patients receiving an SGLT2i versus placebo. CONCLUSION: SGLT2i therapy is associated with a reduced risk of SCD in patients with heart failure receiving contemporary medical therapy. Prospective trials are needed to determine the long-term impact of SGLT2i therapy on atrial and ventricular arrhythmias.


Subject(s)
Atrial Fibrillation , Heart Failure , Sodium-Glucose Transporter 2 Inhibitors , Humans , Atrial Fibrillation/complications , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/epidemiology , Heart Failure/diagnosis , Heart Failure/drug therapy , Heart Failure/complications , Prospective Studies , Randomized Controlled Trials as Topic , Sodium-Glucose Transporter 2 Inhibitors/adverse effects
3.
Europace ; 25(4): 1369-1378, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36794699

ABSTRACT

AIMS: Single-shot pulmonary vein isolation can improve procedural efficiency. To assess the capability of a novel, expandable lattice-shaped catheter to rapidly isolate thoracic veins using pulsed field ablation (PFA) in healthy swine. METHODS AND RESULTS: The study catheter (SpherePVI; Affera Inc) was used to isolate thoracic veins in two cohorts of swine survived for 1 and 5 weeks. In Experiment 1, an initial dose (PULSE2) was used to isolate the superior vena cava (SVC) and the right superior pulmonary vein (RSPV) in six swine and the SVC only in two swine. In Experiment 2, a final dose (PULSE3) was used for SVC, RSPV, and left superior pulmonary vein (LSPV) in five swine. Baseline and follow-up maps, ostial diameters, and phrenic nerve were assessed. Pulsed field ablation was delivered atop the oesophagus in three swine. All tissues were submitted for pathology. In Experiment 1, all 14/14 veins were isolated acutely with durable isolation demonstrated in 6/6 RSPVs and 6/8 SVC. Both reconnections occurred when only one application/vein was used. Fifty-two and 32 sections from the RSPVs and SVC revealed transmural lesions in 100% with a mean depth of 4.0 ± 2.0 mm. In Experiment 2, 15/15 veins were isolated acutely with 14/15 veins (5/5 SVC, 5/5 RSPV, and 4/5 LSPV) durably isolated. Right superior pulmonary vein (31) and SVC (34) sections had 100% transmural, circumferential ablation with minimal inflammation. Viable vessels and nerves were noted without evidence of venous stenosis, phrenic palsy, or oesophageal injury. CONCLUSION: This novel expandable lattice PFA catheter can achieve durable isolation with transmurality and safety.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Swine , Animals , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/pathology , Pulmonary Veins/surgery , Pulmonary Veins/pathology , Vena Cava, Superior/surgery , Feasibility Studies , Catheter Ablation/adverse effects , Catheter Ablation/methods , Catheters , Treatment Outcome
4.
Circulation ; 143(18): 1754-1762, 2021 05 04.
Article in English | MEDLINE | ID: mdl-33820423

ABSTRACT

BACKGROUND: Left atrial appendage (LAA) occlusion provides an alternative to oral anticoagulation for thromboembolic risk reduction in patients with nonvalvular atrial fibrillation. Since regulatory approval in 2015, the WATCHMAN device has been the only LAA closure device available for clinical use in the United States. The PINNACLE FLX study (Protection Against Embolism for Nonvalvular AF Patients: Investigational Device Evaluation of the Watchman FLX LAA Closure Technology) evaluated the safety and effectiveness of the next-generation WATCHMAN FLX LAA closure device in patients with nonvalvular atrial fibrillation in whom oral anticoagulation is indicated, but who have an appropriate rationale to seek a nonpharmaceutical alternative. METHODS: This was a prospective, nonrandomized, multicenter US Food and Drug Administration study. The primary safety end point was the occurrence of one of the following events within 7 days after the procedure or by hospital discharge, whichever was later: death, ischemic stroke, systemic embolism, or device- or procedure-related events requiring cardiac surgery. The primary effectiveness end point was the incidence of effective LAA closure (peri-device flow ≤5 mm), as assessed by the echocardiography core laboratory at 12-month follow-up. RESULTS: A total of 400 patients were enrolled. The mean age was 73.8±8.6 years and the mean CHA2DS2-VASc score was 4.2±1.5. The incidence of the primary safety end point was 0.5% with a 1-sided 95% upper CI of 1.6%, meeting the performance goal of 4.2% (P<0.0001). The incidence of the primary effectiveness end point was 100%, with a 1-sided 95% lower CI of 99.1%, again meeting the performance goal of 97.0% (P<0.0001). Device-related thrombus was reported in 7 patients, no patients experienced pericardial effusion requiring open cardiac surgery, and there were no device embolizations. CONCLUSIONS: LAA closure with this next-generation LAA closure device was associated with a low incidence of adverse events and a high incidence of anatomic closure. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02702271.


Subject(s)
Atrial Appendage/physiopathology , Aged , Humans , Prospective Studies , Treatment Outcome
5.
J Cardiovasc Electrophysiol ; 33(2): 308-314, 2022 02.
Article in English | MEDLINE | ID: mdl-34845805

ABSTRACT

BACKGROUND: Increasing interest in physiological pacing has been countered with challenges such as accurate lead deployment and increasing pacing thresholds with His-bundle pacing (HBP). More recently, left bundle branch area pacing (LBBAP) has emerged as an alternative approach to physiologic pacing. OBJECTIVE: To compare procedural outcomes and pacing parameters at follow-up during initial adoption of HBP and LBBAP at a single center. METHODS: Retrospective review, from September 2016 to January 2020, identified the first 50 patients each who underwent successful HBP or LBBAP. Pacing parameters were then assessed at first follow-up after implantation and after approximately 1 year, evaluating for acceptable pacing parameters defined as sensing R-wave amplitude >5 mV, threshold <2.5 V @ 0.5 ms, and impedance between 400 and 1200 Ω. RESULTS: The HBP group was younger with lower ejection fraction compared to LBBAP (73.2 ± 15.3 vs. 78.2 ± 9.2 years, p = .047; 51.0 ± 15.9% vs. 57.0 ± 13.1%, p = .044). Post-procedural QRS widths were similarly narrow (119.8 ± 21.2 vs. 116.7 ± 15.2 ms; p = .443) in both groups. Significantly fewer patients with HBP met the outcome for acceptable pacing parameters at initial follow-up (56.0% vs. 96.4%, p = .001) and most recent follow-up (60.7% vs. 94.9%, p ≤ .001; at 399 ± 259 vs. 228 ± 124 days, p ≤ .001). More HBP patients required lead revision due to early battery depletion or concern for pacing failure (0% vs. 13.3%, at a mean of 664 days). CONCLUSION: During initial adoption, HBP is associated with a significantly higher frequency of unacceptable pacing parameters, energy consumption, and lead revisions compared with LBBAP.


Subject(s)
Bundle of His , Cardiac Pacing, Artificial , Cardiac Pacing, Artificial/adverse effects , Electrocardiography , Humans , Stroke Volume , Treatment Outcome , Ventricular Function, Left
6.
J Cardiovasc Electrophysiol ; 32(3): 717-725, 2021 03.
Article in English | MEDLINE | ID: mdl-33533089

ABSTRACT

BACKGROUND: The next-generation Watchman FLX left atrial appendage closure (LAAC) device has: (1) an atraumatic closed distal end, (2) reduced height, (3) a recessed screw hub to decrease device-related thrombus (DRT), (4) two rows of J-shape anchors so redeployment is possible after full recapture, and (5) ability to treat a greater size range of LAA ostia. OBJECTIVE: To report, for the first time, the feasibility and safety of intracardiac echocardiography (ICE)-guided Watchman FLX implantation. METHODS: A single-center prospective registry of atrial fibrillation patients planned for LAAC with the FLX device underwent ICE-guided implantation with conscious sedation. Transesophageal echocardiography (TEE) imaging was done preprocedure (to assess LAA size and exclude thrombus) and at clinical follow-up at 6-12 weeks. Clinical outcomes were LAA closure success, complications, leak, or DRT on follow-up TEE and major safety events. RESULTS: The study included 30 patients: age 75 ± 8 years, 53% men, CHA2 DS2 -VASc 4.6 ± 1.6, and HAS-BLED 3.4 ± 1.1. The primary indication was prior bleeding in 60% (72% GI bleeding). The LAA orifice width and length were 22.7 ± 3.1 and 25.7 ± 5.7 mm, respectively. Technical success was 100% (the first-choice device was used in 28 of 30). Procedure time was less than 30 min in 27 of 30 cases, with 36 ± 15 ml contrast used. The final device size was 29.2 ± 4.7 mm with 21.6 ± 4.5% compression. There were no procedure-related complications. Follow-up TEE at a median 47 days follow-up showed 100% device success with no DRT or peridevice leak ≥5 mm. Major safety events occurred in 6.6% (2/30). CONCLUSION: The Watchman FLX device can be safely implanted with intraprocedural ICE imaging instead of TEE.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Aged , Aged, 80 and over , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Cardiac Catheterization/adverse effects , Echocardiography, Transesophageal , Female , Humans , Male , Treatment Outcome
7.
Europace ; 23(11): 1757-1766, 2021 11 08.
Article in English | MEDLINE | ID: mdl-34151947

ABSTRACT

AIMS: We studied the extent/area of electrical pulmonary vein isolation (PVI) after either pulsed field ablation (PFA) using a pentaspline catheter or thermal ablation technologies. METHODS AND RESULTS: In a clinical trial (NCT03714178), paroxysmal atrial fibrillation (PAF) patients underwent PVI with a multi-electrode pentaspline PFA catheter using a biphasic waveform, and after 75 days, detailed voltage maps were created during protocol-specified remapping studies. Comparative voltage mapping data were retrospectively collected from consecutive PAF patients who (i) underwent PVI using thermal energy, (ii) underwent reablation for recurrence, and (iii) had durably isolated PVs. The left and right PV antral isolation areas and non-ablated posterior wall were quantified. There were 20 patients with durable PVI in the PFA cohort, and 39 in the thermal ablation cohort [29 radiofrequency ablation (RFA), 6 cryoballoon, and 4 visually guided laser balloon]. Pulsed field ablation patients were younger with shorter follow-up. Left atrial diameter and ventricular systolic function were preserved in both cohorts. There was no significant difference between the PFA and thermal ablation cohorts in either the left- and right-sided PV isolation areas, or the non-ablated posterior wall area. The right superior PV isolation area was smaller with PFA than RFA, but this disappeared after propensity score matching. Notch-like normal voltage areas were seen at the posterior aspect of the carina in the balloon sub-cohort, but not the PFA or RFA cohorts. CONCLUSION: Catheter-based PVI with the pentaspline PFA catheter creates chronic PV antral isolation areas as encompassing as thermal energy ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/methods , Cryosurgery , Humans , Laser Therapy , Pulmonary Veins/surgery , Radiofrequency Ablation , Recurrence , Retrospective Studies , Treatment Outcome
8.
Pacing Clin Electrophysiol ; 44(3): 528-540, 2021 03.
Article in English | MEDLINE | ID: mdl-33438279

ABSTRACT

Catheter ablation using radiofrequency (RF) energy has been widely used to treat patients with atrial fibrillation (AF). The optimal levels of power and duration to increase the success rate while minimizing complications have not been fully established. Different centers continue to use various power protocols for catheter ablation of AF. Herein, we present a comprehensive review of the impact of power output on efficacy and safety of RF ablation for AF. High-power short-duration (HPSD) ablation can be performed safely with similar procedural efficacy as low-power long-duration ablation strategy. HPSD ablation has the potential to shorten procedural and RF times and create more durable and localized lesions.


Subject(s)
Atrial Fibrillation/surgery , Radiofrequency Ablation/methods , Electrocardiography , Humans , Pulmonary Veins/surgery , Temperature , Time Factors
9.
Pacing Clin Electrophysiol ; 44(4): 711-719, 2021 04.
Article in English | MEDLINE | ID: mdl-33686695

ABSTRACT

BACKGROUND: Same-day discharge (SDD) after atrial fibrillation (AF) ablation is increasingly being considered. This study examined the barriers and financial impact associated with SDD in a contemporary cohort of patients undergoing elective AF ablation. METHODS: A single center retrospective review was conducted of the 249 first case-of-the-day outpatient AF ablations performed in 2019 to evaluate the proportion of patients that could have undergone SDD. Barriers to SDD were defined as any intervention that prevented SDD by 8 p.m. The financial impact of SDD was based on savings from avoidance of the overnight hospital stay and revenue related to management of chest pain facilitated by a vacant hospital bed. RESULTS: SDD could have occurred in 157 patients (63%) without change in management and in up to 200 patients (80%) if avoidable barriers were addressed. Barriers to SDD included non-clinical logistical issues (43%), prolonged post-procedure recovery (42%) and minor procedural complications (15%). On multivariate analysis, factors associated with barriers to SDD included increasing age (P = .01), left ventricular ejection fraction ≤ 35% (P = .04), and severely dilated left atrium (P = .04). The financial gain from SDD would have ranged from $1,110,096 (assuming discharge of 63% of eligible patients) to $1,480,128 (assuming 80% discharge) over the course of a year. CONCLUSIONS: Up to 80% of patients undergoing outpatient AF ablation were amenable to SDD if avoidable delays in care had been anticipated. Based on reduced hospital operating expenses and increased revenue from management of individuals with chest pain, this would translate to a financial savings of ∼$1.5 million.


Subject(s)
Ambulatory Care/economics , Atrial Fibrillation/surgery , Catheter Ablation/methods , Length of Stay/economics , Patient Discharge/economics , Female , Humans , Male , Middle Aged , Patient Selection , Retrospective Studies
10.
J Cardiovasc Electrophysiol ; 31(6): 1323-1331, 2020 06.
Article in English | MEDLINE | ID: mdl-32250501

ABSTRACT

INTRODUCTION: Pulmonary vein isolation (PVI) using standard radiofrequency (RF) catheters is limited by incomplete contiguity and prolonged procedural times. A novel, 9-mm lattice-tip irrigated RF catheter can create wide lesions rapidly in swine atria. METHODS: In five swine, temperature limited (75°C) irrigated RF for 5 seconds/ablation was selected, to isolate seven pulmonary veins (PVs; five right superior and two inferior commons) and create five right atrial lines. After 4 weeks, repeat mapping and additional ablation to create atrial isthmus lesions were performed. The chronic lesions were submitted for histology. This was compared with right superior PVI data using standard 3.5-mm irrigated tip ablation in six swine. RESULTS: All targeted PVs (seven of seven, 100%) were acutely isolated. Durable isolation was observed in all six of six PVs treated with 5-second applications, but not in one PV inadvertently treated with 4-second applications. For the durably isolated PVs, the mean lesion count/PV and total RF time/PV was 16.3 ± 5.2 applications and 81.3 ± 25.9 seconds for the right superior and 14.5 ± 0.7 applications and 71.1 ± 5.5 seconds for the inferior common PV. Right atrial linear ablation was performed with a lesion count of 12 ± 2.3 applications and RF times of 59.5 ± 12.5 seconds. Cavotricuspid and mitral isthmus linear ablations were transmural along their entire length. All 53 of 53 (100%) sections were transmural on histology. CONCLUSION: Rapid and durable PVI and linear atrial ablation is feasible with this novel 9-mm lattice-tip catheter.


Subject(s)
Cardiac Catheters , Catheter Ablation/instrumentation , Pulmonary Veins/surgery , Therapeutic Irrigation/instrumentation , Action Potentials , Animals , Catheter Ablation/adverse effects , Equipment Design , Feasibility Studies , Heart Rate , Operative Time , Pulmonary Veins/pathology , Pulmonary Veins/physiopathology , Reoperation , Sus scrofa , Therapeutic Irrigation/adverse effects , Time Factors
11.
Europace ; 22(3): 434-439, 2020 03 01.
Article in English | MEDLINE | ID: mdl-31876913

ABSTRACT

AIMS: Pulsed field ablation (PFA) is a novel, non-thermal modality that selectively ablates myocardium with ultra-short electrical impulses while sparing collateral tissues. In a proof-of-concept study, the safety and feasibility of ventricular PFA were assessed using a prototype steerable, endocardial catheter. METHODS AND RESULTS: Under general anaesthesia, the left and right ventricles of four healthy swine were ablated using the 12-Fr deflectable PFA catheter and a deflectable sheath guided by electroanatomic mapping. Using the study catheter, electrograms were recorded for each site and pre-ablation and post-ablation pacing thresholds (at 2.0 ms pulse width) were recorded in two of four animals. After euthanasia at 35.5 days, the hearts were submitted for histology. The PFA applications (n = 39) resulted in significant electrogram reduction without ventricular arrhythmias. In ablation sites where it was measured, the pacing thresholds increased by >16.8 mA in the right ventricle (3 sites) and >16.1 mA in the left ventricle (7 sites), with non-capture at maximum amplitude (20 mA) observable in 8 of 10 sites. Gross measurements, available for 28 of 30 ablation sites, revealed average lesion dimensions to be 6.5 ± 1.7 mm deep by 22.6 ± 4.1 mm wide, with a maximum depth and width of 9.4 mm and 28.6 mm, respectively. In the PFA lesions, fibrous tissue homogeneously replaced myocytes with a narrow zone of surrounding myocytolysis and no overlying thrombus. When present, nerve fascicles and vasculature were preserved within surrounding fibrosis. CONCLUSION: We demonstrate that endocardial PFA can be focally delivered using this prototype catheter to create homogeneous, myocardium-specific lesions.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Animals , Arrhythmias, Cardiac , Endocardium , Heart Ventricles/surgery , Myocardium , Swine , Tachycardia, Ventricular/surgery
12.
Europace ; 22(2): 232-239, 2020 02 01.
Article in English | MEDLINE | ID: mdl-31755937

ABSTRACT

AIMS: During atrial fibrillation ablation, oesophageal heating typically prompts reduction or termination of radiofrequency energy delivery. We previously demonstrated oesophageal temperature rises are associated with posterior left atrial pulmonary vein reconnection (PVR) during redo procedures. In this study, we assessed whether mechanical oesophageal deviation (MED) during an index procedure minimizes posterior wall PVRs during redo procedures. METHODS AND RESULTS: Patients in whom we performed a first-ever procedure followed by a clinically driven redo procedure were divided based on both the use of MED for oesophageal protection and the ablation catheter employed (force or non-force sensing) in the first procedure. The PVR sites were compared between MED using a force-sensing catheter (MEDForce), or no MED with a non-force (ControlNoForce) or force (ControlForce) sensing catheter. Despite similar clinical characteristics, the MEDForce redo procedure rate (9.2%, 26/282 patients) was significantly less than the ControlNoForce (17.2%, 126/734 patients; P = 0.002) and ControlForce (17.5%, 20/114 patients; P = 0.024) groups. During the redo procedure, the posterior PVR rate with MEDForce (2%, 1/50 PV pairs) was significantly less than with either ControlNoForce (17.7%, 44/249 PV pairs; P = 0.004) or ControlForce (22.5%, 9/40 PV pairs; P = 0.003), or aggregate Controls (18.3%, 53/289 PV pairs; P = 0.006). However, the anterior PVR rate with MEDForce (8%, 4/50 PV pairs) was not significantly different than Controls (aggregate Controls-3.5%, 10/289 PV pairs, P = 0.136; ControlNoForce-2.4%, 6/249 PV pairs, P = 0.067; ControlForce-10%, 4/40 PV pairs, P = 1.0). CONCLUSION: Oesophageal deviation improves the durability of the posterior wall ablation lesion set during AF ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Humans , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
13.
Pacing Clin Electrophysiol ; 43(10): 1139-1148, 2020 10.
Article in English | MEDLINE | ID: mdl-32840325

ABSTRACT

INTRODUCTION: Recent studies have described several cardiovascular manifestations of COVID-19 including myocardial ischemia, myocarditis, thromboembolism, and malignant arrhythmias. However, to our knowledge, syncope in COVID-19 patients has not been systematically evaluated. We sought to characterize syncope and/or presyncope in COVID-19. METHODS: This is a retrospective analysis of consecutive patients hospitalized with laboratory-confirmed COVID-19 with either syncope or presyncope. This "study" group (n = 37) was compared with an age and gender-matched cohort of patients without syncope ("control") (n = 40). Syncope was attributed to various categories. We compared telemetry data, treatments received, and clinical outcomes between the two groups. RESULTS: Among 1000 COVID-19 patients admitted to the Mount Sinai Hospital, the incidence of syncope/presyncope was 3.7%. The median age of the entire cohort was 69 years (range 26-89+ years) and 55% were men. Major comorbidities included hypertension, diabetes, and coronary artery disease. Syncopal episodes were categorized as (a) unspecified in 59.4% patients, (b) neurocardiogenic in 15.6% patients, (c) hypotensive in 12.5% patients, and (d) cardiopulmonary in 3.1% patients with fall versus syncope and seizure versus syncope in 2 of 32 (6.3%) and 1 of 33 (3.1%) patients, respectively. Compared with the "control" group, there were no significant differences in both admission and peak blood levels of d-dimer, troponin-I, and CRP in the "study" group. Additionally, there were no differences in arrhythmias or death between both groups. CONCLUSIONS: Syncope/presyncope in patients hospitalized with COVID-19 is uncommon and is infrequently associated with a cardiac etiology or associated with adverse outcomes compared to those who do not present with these symptoms.


Subject(s)
Coronavirus Infections/complications , Pneumonia, Viral/complications , Syncope/virology , Adult , Aged , Aged, 80 and over , Betacoronavirus , COVID-19 , Comorbidity , Female , Hospitalization , Humans , Incidence , Male , Middle Aged , New York City/epidemiology , Pandemics , Retrospective Studies , SARS-CoV-2 , Syncope/epidemiology , Telemetry
14.
Ann Intern Med ; 170(1): 41-50, 2019 01 01.
Article in English | MEDLINE | ID: mdl-30583296

ABSTRACT

This article has been corrected. The original version (PDF) is appended to this article as a Supplement. Background: Atrial fibrillation (AF) and heart failure (HF) frequently coexist and are associated with increased morbidity and mortality risk. Purpose: To compare benefits and harms between catheter ablation and drug therapy in adult patients with AF and HF. Data Sources: ClinicalTrials.gov, PubMed, Web of Science (Clarivate Analytics), EBSCO Information Services, Cochrane Central Register of Controlled Trials, Google Scholar, and various scientific conference sessions from 1 January 2005 to 1 October 2018. Study Selection: Randomized controlled trials (RCTs) published in English that had at least 6 months of follow-up and compared clinical outcomes of catheter ablation versus drug therapy in adults with AF and HF. Data Extraction: 2 investigators independently extracted data and assessed study quality. Data Synthesis: 6 RCTs involving 775 patients met inclusion criteria. Compared with drug therapy, AF ablation reduced all-cause mortality (9.0% vs. 17.6%; risk ratio [RR], 0.52 [95% CI, 0.33 to 0.81]) and HF hospitalizations (16.4% vs. 27.6%; RR, 0.60 [CI, 0.39 to 0.93]). Ablation improved left ventricular ejection fraction (LVEF) (mean difference, 6.95% [CI, 3.0% to 10.9%]), 6-minute walk test distance (mean difference, 20.93 m [CI, 5.91 to 35.95 m]), peak oxygen consumption (Vo2max) (mean difference, 3.17 mL/kg per minute [CI, 1.26 to 5.07 mL/kg per minute]), and quality of life (mean difference in Minnesota Living with Heart Failure Questionnaire score, -9.02 points [CI, -19.75 to 1.71 points]). Serious adverse events were more common in the ablation groups, although differences between the ablation and drug therapy groups were not statistically significant (7.2% vs. 3.8%; RR, 1.68 [CI, 0.58 to 4.85]). Limitation: Results driven primarily by 1 clinical trial, possible patient selection bias in the ablation group, lack of patient-level data, open-label trial designs, and heterogeneous follow-up length among trials. Conclusion: Catheter ablation was superior to conventional drug therapy in improving all-cause mortality, HF hospitalizations, LVEF, 6-minute walk test distance, Vo2max, and quality of life, with no statistically significant increase in serious adverse events. Primary Funding Source: None.


Subject(s)
Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Catheter Ablation , Heart Failure/complications , Anti-Arrhythmia Agents/adverse effects , Atrial Fibrillation/complications , Atrial Fibrillation/mortality , Catheter Ablation/adverse effects , Cause of Death , Exercise Tolerance , Heart Failure/mortality , Hospitalization/statistics & numerical data , Humans , Oxygen Consumption , Postoperative Complications , Quality of Life , Randomized Controlled Trials as Topic , Risk Assessment , Stroke Volume , Walk Test
15.
Circulation ; 138(9): 874-885, 2018 08 28.
Article in English | MEDLINE | ID: mdl-29752398

ABSTRACT

BACKGROUND: In patients with atrial fibrillation, left atrial appendage closure with the Watchman device prevents thromboembolism from the left atrial appendage; however, thrombus may form on the left atrial face of the device, and then potentially embolize. Herein, we studied the incidence, predictors, and clinical outcome of device-related thrombus (DRT) using a large series of clinical trial cohorts of patients undergoing Watchman implantation. METHODS: We studied the device arms of 4 prospective Food and Drug Administration trials: PROTECT-AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) (n=463); PREVAIL (Evaluation of the Watchman LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy) (n=269); CAP (Continued Access to PROTECT AF registry) (n=566); and CAP2 (Continued Access to PREVAIL registry) (n=578). Surveillance transesophageal echocardiographs were performed at 45 days and 12 months in all patients, and also at 6 months in the randomized control trials. We assessed both the incidence of DRT during these transesophageal echocardiographs (and other unscheduled transesophageal echocardiographs), and clinical outcomes of postprocedure stroke or systemic embolism (SSE) and adjusted for CHA2DS2-VASC and HAS-BLED scores. RESULTS: Of 1739 patients who received an implant (7159 patient-years follow-up; CHA2DS2-VASc=4.0), DRT was seen in 65 patients (3.74%). The rates of SSE with and without DRT were 7.46 and 1.78 per 100 patient-years (adjusted rate ratio, 3.55; 95% confidence interval [CI], 2.18-5.79; P<0.001), and ischemic SSE rates were 6.28 and 1.65 per 100 patient-years (adjusted rate ratio, 3.22; 95% CI, 1.90-5.45, P<0.001). On multivariable modeling analysis, the predictors of DRT were as follows: history of transient ischemic attack or stroke (odds ratio [OR], 2.31; 95% CI, 1.26-4.25; P=0.007), permanent atrial fibrillation (OR, 2.24; 95% CI, 1.19-4.20; P=0.012); vascular disease (OR, 2.06; 95% CI, 1.08-3.91; P=0.028); left atrial appendage diameter (OR, 1.06 per mm increase; 95% CI, 1.01-1.12; P=0.019); left ventricular ejection fraction (OR, 0.96 per 1% increase; 95% CI, 0.94-0.99; P=0.009). DRT and SSE both occurred in 17 of 65 patients (26.2%). Of the 19 SSE events in these patients with DRT, 9 of 19 (47.4%) and 12 of 19 (63.2%) occurred within 1 and 6 months of DRT detection. Conversely, after left atrial appendage closure, most SSEs (123/142, 86.62%) occurred in patients without DRT. CONCLUSIONS: After left atrial appendage closure with Watchman, DRT (≈3.7%) is not frequent but, when present, is associated with a higher rate of stroke and systemic embolism.


Subject(s)
Atrial Appendage/physiopathology , Atrial Fibrillation/therapy , Atrial Function, Left , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Intracranial Embolism/epidemiology , Stroke/epidemiology , Thrombosis/epidemiology , Aged , Aged, 80 and over , Atrial Appendage/diagnostic imaging , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Echocardiography, Transesophageal , Female , Humans , Incidence , Intracranial Embolism/diagnostic imaging , Male , Prosthesis Design , Randomized Controlled Trials as Topic , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Stroke/diagnostic imaging , Thrombosis/diagnostic imaging , Time Factors , Treatment Outcome
16.
J Cardiovasc Electrophysiol ; 30(1): 141-148, 2019 01.
Article in English | MEDLINE | ID: mdl-30230098

ABSTRACT

INTRODUCTION: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is most commonly implanted under general anesthesia (GA), due to the intraoperative discomfort associated with tunneling and dissection. Postoperative pain can be substantial and is often managed with opioids. There is a growing interest in transitioning away from the routine use of GA during S-ICD implantation, while also controlling perioperative discomfort without the use of narcotics. As such, we assessed the feasibility of a multimodal analgesia regimen that included regional anesthesia techniques in patients undergoing S-ICD implantation. METHODS AND RESULTS: Twenty patients received truncal plane block (TBL) immediately before S-ICD implantation. The first 10 patients were implanted under general anesthesia (GA + TBL), and the next 10 patients were implanted under deep sedation (DS + TBL). Additionally, the DS + TBL patients were also prescribed a structured regimen of nonopioid analgesics in the perioperative period. Opioid consumption was calculated as milligram morphine equivalents (MME). In-hospital opioid consumption was significantly lower in the patients implanted with DS + TBL (MME = 0) as compared with patients receiving GA + TBL (MME = 60; P = 0.004). CONCLUSIONS: Subcutaneous ICD implantation with anesthesia-delivered DS and a multimodal anesthetic regimen that includes TBL is feasible and associated with significantly less perioperative opioid consumption.


Subject(s)
Analgesics, Non-Narcotic/administration & dosage , Analgesics, Opioid/administration & dosage , Anesthesia, General , Autonomic Nerve Block , Deep Sedation , Defibrillators, Implantable , Electric Countershock/instrumentation , Pain, Postoperative/prevention & control , Prosthesis Implantation/instrumentation , Adult , Aged , Analgesics, Non-Narcotic/adverse effects , Analgesics, Opioid/adverse effects , Anesthesia, General/adverse effects , Autonomic Nerve Block/adverse effects , Deep Sedation/adverse effects , Feasibility Studies , Female , Humans , Male , Middle Aged , Pain, Postoperative/diagnosis , Pain, Postoperative/etiology , Prosthesis Implantation/adverse effects , Retrospective Studies , Treatment Outcome
17.
N Engl J Med ; 373(12): 1125-35, 2015 Sep 17.
Article in English | MEDLINE | ID: mdl-26321198

ABSTRACT

BACKGROUND: Cardiac pacemakers are limited by device-related complications, notably infection and problems related to pacemaker leads. We studied a miniaturized, fully self-contained leadless pacemaker that is nonsurgically implanted in the right ventricle with the use of a catheter. METHODS: In this multicenter study, we implanted an active-fixation leadless cardiac pacemaker in patients who required permanent single-chamber ventricular pacing. The primary efficacy end point was both an acceptable pacing threshold (≤2.0 V at 0.4 msec) and an acceptable sensing amplitude (R wave ≥5.0 mV, or a value equal to or greater than the value at implantation) through 6 months. The primary safety end point was freedom from device-related serious adverse events through 6 months. In this ongoing study, the prespecified analysis of the primary end points was performed on data from the first 300 patients who completed 6 months of follow-up (primary cohort). The rates of the efficacy end point and safety end point were compared with performance goals (based on historical data) of 85% and 86%, respectively. Additional outcomes were assessed in all 526 patients who were enrolled as of June 2015 (the total cohort). RESULTS: The leadless pacemaker was successfully implanted in 504 of the 526 patients in the total cohort (95.8%). The intention-to-treat primary efficacy end point was met in 270 of the 300 patients in the primary cohort (90.0%; 95% confidence interval [CI], 86.0 to 93.2, P=0.007), and the primary safety end point was met in 280 of the 300 patients (93.3%; 95% CI, 89.9 to 95.9; P<0.001). At 6 months, device-related serious adverse events were observed in 6.7% of the patients; events included device dislodgement with percutaneous retrieval (in 1.7%), cardiac perforation (in 1.3%), and pacing-threshold elevation requiring percutaneous retrieval and device replacement (in 1.3%). CONCLUSIONS: The leadless cardiac pacemaker met prespecified pacing and sensing requirements in the large majority of patients. Device-related serious adverse events occurred in approximately 1 in 15 patients. (Funded by St. Jude Medical; LEADLESS II ClinicalTrials.gov number, NCT02030418.).


Subject(s)
Arrhythmias, Cardiac/therapy , Pacemaker, Artificial , Adult , Aged , Aged, 80 and over , Arrhythmias, Cardiac/mortality , Electrocardiography, Ambulatory , Electrodes, Implanted , Equipment Design , Equipment Failure , Female , Follow-Up Studies , Humans , Intention to Treat Analysis , Male , Middle Aged , Pacemaker, Artificial/adverse effects , Prospective Studies
18.
J Cardiovasc Electrophysiol ; 28(11): 1295-1302, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28800178

ABSTRACT

INTRODUCTION: There is a paucity of data in favor of mechanical support during catheter ablation of ventricular tachycardia (VT). This study investigated the outcomes of VT ablation associated with mechanical support using percutaneous ventricular assist device (PVAD) versus intra-aortic balloon pump (IABP). METHODS AND RESULTS: We retrospectively examined the outcomes of patients who underwent VT ablation associated with PVAD versus IABP from 2010 to 2013, captured by the Medicare Inpatient Standard Analytic File database. Data from 345 patients (PVAD = 230, IABP = 115) were examined. On admission, the incidence of heart failure was higher in PVAD (84.3% vs. 73.0%; P = 0.01) with similar rates of renal failure in PVAD versus IABP (33.0% vs. 37.4%; P = 0.42). However, PVAD was associated with reduced in-hospital cardiogenic shock (9.1% vs. 23.5%; P  <  0.001), renal failure (11.7% vs. 21.7%; P = 0.01), and length of stay (8.4 ± 7.9 vs. 10.6 ± 7.5; P < 0.001), but with greater hospital discharges to home/self-care (66.0% vs. 51.6%; P = 0.02). Index mortality (6.5% vs. 19.1%; P = 0.001) and mortality in patients with cardiogenic shock (18.2% vs. 41.2%; P = 0.03) were significantly lower with PVAD versus IABP. Furthermore, PVAD was associated with lower all-cause (27.0% vs. 38.7%; P = 0.04) and heart failure-related (21.4% vs. 33.3%; P = 0.03) 30-day hospital readmissions, but with similar redo-VT ablation rates at 1 year (10.2% vs. 14.0%; P = 0.34). CONCLUSION: Among the cases captured by the Medicare database, catheter ablation of VT associated with mechanical support using PVAD was associated with reduced in-hospital cardiogenic shock, renal failure, length of stay, hospital readmissions and mortality, but no difference in redo-VT ablation at 1 year.


Subject(s)
Catheter Ablation/trends , Databases, Factual/trends , Heart-Assist Devices/trends , Medicare/trends , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/surgery , Aged , Aged, 80 and over , Female , Hemodynamics/physiology , Humans , Longitudinal Studies , Male , Patient Discharge/trends , Retrospective Studies , Tachycardia, Ventricular/physiopathology , United States/epidemiology
19.
Europace ; 19(10): 1657-1663, 2017 Oct 01.
Article in English | MEDLINE | ID: mdl-27702847

ABSTRACT

AIMS: Controversy on the optimal ablation strategy for persistent atrial fibrillation (AF) exists with limited work evaluating a strategy of pulmonary vein isolation (PVI) alone when AF terminates during PVI. Thirty-five patients had AF termination during PVI in the Modified Ablation Guided by Ibutilide Use in Chronic Atrial Fibrillation (MAGIC-AF; ClinicalTrials.gov number: NCT01014741) study. The objective of the current study is to report the 1-year outcome after PVI alone in this unique patient group. METHODS AND RESULTS: The 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs was reported for the 35 patients in the MAGIC-AF study with persistent AF termination during or upon completion of PVI. Freedom from recurrent atrial arrhythmia was achieved in 60% of patients where AF terminated during PVI. Cavotricuspid isthmus flutter was common when AF terminated to a macro re-entrant flutter during PVI, and responsible for 92% of all flutter circuits with AF termination. CONCLUSIONS: Persistent AF termination during PVI may identify a subgroup of patients who experience a similar long-term clinical outcome with PVI ablation alone when compared with other more extensive persistent AF ablation strategies. Pulmonary vein isolation alone may be an appropriate tactic in this subgroup of persistent AF patients.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Pulmonary Veins/surgery , Action Potentials , Aged , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Flutter/etiology , Canada , Catheter Ablation/adverse effects , Disease-Free Survival , Double-Blind Method , Electrocardiography, Ambulatory , Electrophysiologic Techniques, Cardiac , Female , Heart Rate , Humans , Male , Middle Aged , Pulmonary Veins/physiopathology , Recurrence , Registries , Republic of Korea , Time Factors , Treatment Outcome , United States
20.
Eur Heart J ; 37(20): 1614-21, 2016 May 21.
Article in English | MEDLINE | ID: mdl-26850076

ABSTRACT

AIMS: Complex fractionated atrial electrograms (CFAE) are targeted during persistent atrial fibrillation (AF) ablation. However, many CFAE sites are non-specific resulting in extensive ablation. Ibutilide has been shown to reduce left atrial surface area exhibiting CFAE. We hypothesized that ibutilide administration prior to CFAE ablation would identify sites critical for persistent AF maintenance allowing for improved procedural efficacy and long-term freedom from atrial arrhythmias. METHODS AND RESULTS: Two hundred patients undergoing a first-ever persistent AF catheter ablation procedure were randomly assigned to receive either 0.25 mg of intravenous ibutilide or saline placebo upon completion of pulmonary vein isolation. Complex fractionated atrial electrogram sites were then targeted with ablation. The primary efficacy endpoint was the 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs. Similar procedural characteristics (procedure, fluoroscopy, and ablation times) were observed with both strategies despite a greater reduction in left atrial surface area with CFAE sites (8 vs. 1%, P < 0.0001) and AF termination during CFAE ablation with ibutilide compared with placebo (75 vs. 57%, P = 0.007). The primary efficacy endpoint was achieved in 56% of patients receiving ibutilide and 49% receiving placebo (P = 0.35). No significant differences in peri-procedural complications were observed in both groups. CONCLUSION: Despite a reduction in CFAE area and greater AF termination during CFAE ablation, procedural characteristics and clinical outcomes were unchanged when CFAE ablation was guided by ibutilide administration. CLINICAL TRIAL REGISTRATION INFORMATION: ClinicalTrials.gov number: NCT01014741.


Subject(s)
Atrial Fibrillation/drug therapy , Sulfonamides/therapeutic use , Catheter Ablation , Chronic Disease , Electrophysiologic Techniques, Cardiac , Humans , Pulmonary Veins , Treatment Outcome