Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Country/Region as subject
Language
Affiliation country
Publication year range
1.
J Cardiothorac Vasc Anesth ; 35(5): 1281-1285, 2021 05.
Article in English | MEDLINE | ID: mdl-33214043

ABSTRACT

As hospitals became overwhelmed during the Covid-19 pandemic in March-May in New York, Cardiology and Electrophysiology (EP) departments rapidly developed protocols for case selection as well modifying the practice of managing the cases. Recommendations by the AHA/HRS as well as American Society of Anesthesiology (ASA) were considered in the multidisciplinary collaborative approach to patient care and personnel safety and the anesthesiology team had an integral role in developing protocols for workflow, care, recovery and transport during these challenging times.


Subject(s)
COVID-19 , Electrophysiology , Pandemics , Tertiary Care Centers , Female , Humans , Male , New York/epidemiology , SARS-CoV-2 , United States
2.
Pacing Clin Electrophysiol ; 27(5): 594-9, 2004 May.
Article in English | MEDLINE | ID: mdl-15125714

ABSTRACT

RF catheter ablation of ventricular tachycardia is sometimes limited by inadequate lesion depth. This study investigated the use of a retractable needle-tipped catheter to create deep RF lesions in vivo in porcine myocardium. An 8 Fr electrode catheter with an extendable 27-gauge needle at the tip was modified for RF ablation by embedding a thermocouple and attaching a pin connector. In three swine (32-58 kg) the left ventricle was entered via the femoral artery and endocardial contact was made. The needle was advanced 10 mm and 13 RF applications were made under a controlled temperature (90 degrees C x 120 s). Nine control lesions were made using a standard 4-mm tip catheter (60 degrees C x 120 s). The lesions were fixed, serially sectioned from the endocardium, digitally imaged, and quantified. Needle ablation lesions were deeper (10.15 +/- 0.77 vs 5.67 +/- 0.37 mm, P < 0.001) and more likely to be transmural (77 vs 11%, P = 0.008) than control lesions. The volume of control lesions, however, was larger (358.4 +/- 56.2 vs 174.7 +/- 18.6 mm(3), P = 0.002) due to a significantly larger cross-sectional area at the endocardium (0.548 +/- 0.04 vs 0.151 +/- 0.01 cm(2), P < 0.001). At depths > 6 mm, the needle electrode lesions had a greater cross-sectional area (0.136 +/- 0.01 vs 0.005 +/- 0.004 cm(2), P < 0.001). Catheter-based needle ablation is feasible and allows creation of deeper lesions that can be transmural. Although deep, the lesions had a small cross-sectional area such that precise targeting would be required for success.


Subject(s)
Catheter Ablation/instrumentation , Myocardium/pathology , Animals , Equipment Design , Feasibility Studies , Male , Swine
SELECTION OF CITATIONS
SEARCH DETAIL