Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Rev Sci Instrum ; 91(7): 074712, 2020 Jul 01.
Article in English | MEDLINE | ID: mdl-32752818

ABSTRACT

A module of a wireless high voltage generator was tested immersed in both gaseous and liquid environments providing electrical insulation. The overall performance of the module as well as a detailed performance of the key components are reported, and a comparison between the results in gas and liquid is given. The tests performed on the liquid dielectric show that it is a valid alternative to high pressure gas electrical insulation.

2.
Rev Sci Instrum ; 79(2 Pt 2): 02A301, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18315091

ABSTRACT

Beams from electron cyclotron resonance ion source (ECRIS) with radio frequency ovens for refractory material (using a Mo coil) were recently demonstrated; results for Ti and V are here discussed, with temperature T(s) > or = 2300 K stably maintained and extracted current of about 1000 nA for V(8+) and V(9+). The status of sputter probes is also reported, and the reason why trapping efficiency may be lower than in the oven case are investigated. The simple tubular probe concept show typical currents of Sn(18+) about 250 nA, for the most abundant isotopes, but an operating pressure of about 300 microPa may be required. Some preliminary experiments were performed with Penning probes, showing that transmission of Sn or Pr from Penning cathode to ECRIS plasma is limited. Placement of tin onto anticathode and use of collimator between Penning and ECRIS are also discussed.

3.
Rev Sci Instrum ; 85(2): 02A929, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24593508

ABSTRACT

The ECR ion sources are able to produce a wide variety of highly charged metallic ion beams thanks to the development of different techniques (ovens, sputtering, direct insertion, metal ions from volatile compounds (MIVOC)). In the case of the ovens, the sticking of the hot vapors on the surface of the plasma chamber leads to high material consumption rates. For elements like Ca, a tantalum liner inserted inside the chamber can be used to limit this phenomenon. The modeling of temperature distribution inside the chamber with and without the liner was carried out with COMSOL-multiphysics code. Results of simulation and the comparison with experiments performed at INFN-Legnaro National Laboratories with Ca beams are discussed.

4.
Rev Sci Instrum ; 81(2): 02A315, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20192336

ABSTRACT

From April 2008 the PIAVE injector for the ALPI booster was involved in the upgrade of the high voltage platform housing an electron cyclotron resonance (ECR) source. A 14.5 GHz SUPERNANOGAN type ECR replaced the existing source ALICE; at the same time, the whole platform beam line was redesigned and beam shaping and diagnostic system were installed. The source and the platform were ready to be put into operation in January 2009. PIAVE's commissioning was started from late March and completed in May 2009 using an argon beam. A description of the upgrade will be given in the following; beam quality leading to an improved transmission through the injector will be shown. Results on first gaseous and metallic beams produced will also be given.

SELECTION OF CITATIONS
SEARCH DETAIL