Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters

Database
Country/Region as subject
Language
Journal subject
Affiliation country
Publication year range
1.
J Org Chem ; 87(5): 3276-3285, 2022 Mar 04.
Article in English | MEDLINE | ID: mdl-35176857

ABSTRACT

We designed and synthesized a novel di(benz[f]indenone)-fused tetraazaanthracene derivative and isolated its two isomers, 1a and 1s, having anti and syn configurations, respectively. Their structure and that of the condensation reaction intermediates, anti-2a and syn-2s, were fully characterized using one- and two-dimensional nuclear magnetic resonance spectroscopy and single-crystal X-ray diffraction. The optical and electronic properties of 1a and 1s were investigated using ultraviolet-visible absorption and fluorescence spectroscopies, cyclic voltammetry, and time-dependent density functional theory calculations. The presence of the carbonyl and ethynyltris(isopropyl)silane groups endows the di(benzoindenone)-fused azaacene derivatives with a strong electron accepting character. With an electron affinity of approximately -3.7 eV, the two isomers represent attractive electron-deficient molecular systems for the generation of n-channel semiconducting materials. Organic field effect transistors of 1a and 1s showed electron transport, and organic solar cells gave a proof of concept of the potential of the two compounds as electron acceptor materials when they are paired with an electron donor polymer.

2.
Small Methods ; 8(2): e2300373, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37391271

ABSTRACT

The fabrication of high quality nanophotonic surfaces for integration in optoelectronic devices remains a challenge because of the complexity and cost of top-down nanofabrication strategies. Combining colloidal synthesis with templated self-assembly emerged as an appealing low-cost solution. However, it still faces several obstacles before integration in devices can become a reality. This is mostly due to the difficulty in assembling small nanoparticles (<50 nm) in complex nanopatterns with a high yield. In this study, a reliable methodology is proposed to fabricate printable nanopatterns with an aspect ratio varying from 1 to 10 and a lateral resolution of 30 nm via nanocube assembly and epitaxy. Investigating templated assembly via capillary forces, a new regime was identified that was used to assemble 30-40 nm nanocubes in a patterned polydimethylsiloxane template with a high yield for both Au and Ag with multiple particles per trap. This new method relies on the generation and control of an accumulation zone at the contact line that is thin as opposed to dense, displaying higher versatility. This is in contrast with conventional wisdom, identifying a dense accumulation zone as a requirement for high-yield assembly. In addition, different formulations are proposed that can be used for the colloidal dispersion, showing that the standard water-surfactant solutions can be replaced by surfactant-free ethanol solutions, with good assembly yield. This allows to minimize the presence of surfactants that can affect electronic properties. Finally, it is shown that the obtained nanocube arrays can be transformed into continuous monocrystalline nanopatterns via nanocube epitaxy at near ambient temperature, and transferred to different substrates via contact printing. This approach opens new doors to the templated assembly of small colloids and could find potential applications in various optoelectronic devices ranging from solar cells to light-emitting diodes and displays.

3.
J Arrhythm ; 38(3): 432-438, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35785388

ABSTRACT

Background: Arrhythmia is a significant clinical modifier in COVID-19 patient outcomes. Currently, data on arrhythmia and ECG characteristics in COVID-19 from lower middle-income countries are limited. Methods: COVID-19 was confirmed by polymerase chain reaction testing of a nasopharyngeal sample. All clinical records were systematically evaluated to obtain demographic characteristics and medical comorbidities. The ECG was recorded on admission, in-hospital, and at discharge. Results: Total documented arrhythmia events account for 22% of patients, comprising 6% of new-onset arrhythmia and 16% of existing arrhythmia. Atrial fibrillation is the most common arrhythmia. The ECG changes were a decrease in heart rate (91 ± 22 vs. 83 ± 20, p < .001) and an increase in the QT interval (354.7 ± 53.70 vs. 371.4 ± 59.48 msec, p < .001) from hospital admission to hospital discharge, respectively. The in-hospital HR of 85 bpm or higher increases the risk of death (OR = 2.69, p = .019). Conclusion: The incidence of arrhythmias in COVID-19 patients at COVID-19 referral hospitals in Indonesia is 22%. Atrial fibrillation is the most common arrhythmia in COVID-19 patients. Prolongation of QRS duration from admission to discharge was related to the occurrence of new-onset arrhythmia. The in-hospital HR of 85 bpm or higher increased the risk of death.

4.
PLoS Negl Trop Dis ; 13(8): e0007606, 2019 08.
Article in English | MEDLINE | ID: mdl-31381570

ABSTRACT

Dengue virus transmission is endemic in Makassar, Indonesia, with the majority of cases reported soon after the start of the annual rainy season. Before 2006, larval source reduction, larvaciding, and reactive routine, outdoor, insecticide fogging campaigns did not result in a reduction in seasonal dengue incidence. Beginning in 2006, village volunteers conducted comprehensive surveys for immature Aedes during the dry season, when vector populations were at their lowest. Based on this pre-season vector data, a single additional pre-emptive outdoor fogging with Malathion was conducted once annually before the rains began in villages with a pre-defined proportion of sampled houses positive for Aedes immatures. This additional procedure was associated with reduced temporal larval indices as well as an 83% reduction in reported cases during the transmission season over the 8-year period of implementation. Two cities adjacent to Makassar experienced substantial but smaller reductions in dengue incidence; while other cities further from the intervention area did not. This represents the first time an integrated intervention strategy has been coupled with substantially reduced dengue transmission in Indonesia.


Subject(s)
Dengue/transmission , Disease Vectors , Seasons , Weather , Aedes/virology , Animals , Cities , Dengue/epidemiology , Dengue Virus , Incidence , Indonesia/epidemiology , Insecticides , Larva , Mosquito Vectors/virology , Rain
SELECTION OF CITATIONS
SEARCH DETAIL