Catheter Cardiovasc Interv ; 96(1): 158-166, 2020 07.
Article in English | MEDLINE | ID: mdl-31566902

ABSTRACT

OBJECTIVES: We wished to undertake a reconstructed individual patient data meta-analysis of randomized clinical trials comparing transcatheter aortic valve replacement (TAVR) and surgery for patients with severe symptomatic aortic stenosis. BACKGROUND: TAVR and surgery are both well-established methods for treating patients with symptomatic severe aortic stenosis who are at low, intermediate, and high risk for surgery. METHODS: Data were identified by searches of Medline, Embase, CENTRAL and ClinicalTrials.gov for all randomized clinical trials, which compared TAVR and surgery that had published at least 1 year of follow-up. Individual patient data were reconstructed from Kaplan-Meier curves. RESULTS: A total of 7,770 patients from seven randomized clinical trials were included in this meta-analysis. At 1 year, TAVR was associated with a lower risk of death from any cause (hazard ratio [HR], 0.85, 95% confidence interval [CI], 0.73-0.98; p = .03), disabling stroke (HR, 0.71; 95% CI, 0.54-0.93; p = .01) and the composite end point of death or disabling stroke (HR, 0.79; 95% CI, 0.67-0.92; p = .002). Significant interactions were found for access suitability, with TAVR associated with a lower risk of these end points in patients suitable for transfemoral access. TAVR was associated with a lower risk of periprocedural events, whereas the risk of late events was similar between TAVR and surgery. CONCLUSIONS: At 1 year, TAVR was associated with a lower risk of death, disabling stroke and the composite end point, when compared with surgery. These associations were strongest within the subgroup of patients in whom transfemoral access was feasible.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Randomized Controlled Trials as Topic , Risk Assessment , Risk Factors , Severity of Illness Index , Stroke/etiology , Stroke/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
2.
Catheter Cardiovasc Interv ; 95(7): 1340-1346, 2020 06 01.
Article in English | MEDLINE | ID: mdl-31713325

ABSTRACT

OBJECTIVES: The United Kingdom and Ireland Implanters' registry is a multicenter registry which reports on real-world experience with new transcatheter heart valves. BACKGROUND: The Evolut PRO (Medtronic, Minneapolis, MN) transcatheter aortic valve is a self-expanding transcatheter aortic valve with an outer pericardial wrap, designed to minimize paravalvular regurgitation. METHODS: Between July 2017 and December 2018, clinical, procedural, and 30-day outcome data were prospectively collected from all patients receiving the Evolut PRO valve across nine participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2 (VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 317 patients underwent implantation. Mean age was 81.8 ± 6.4 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.5 ± 1.8%. Iliofemoral access was used in 99.1% of patients. Device success was 91.2%. Mean gradient was 7.6 ± 4.7 mmHg and effective orifice area 1.9 ± 0.7 cm2 . The incidence of moderate paravalvular regurgitation was 1.7% and there was no severe paravalvular regurgitation. A new permanent pacemaker was implanted in 17.8% of patients without a pacemaker at baseline. Early safety was demonstrated in 92.7%. At 30 days, all-cause mortality was 0.6%, stroke 3.8%, and major vascular complication 2.8%. CONCLUSIONS: Real-world experience of the Evolut PRO transcatheter aortic valve demonstrated favorable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis , Pericardium/transplantation , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Humans , Ireland , Male , Prosthesis Design , Registries , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United Kingdom
3.
Clin Transplant ; 34(11): e14061, 2020 11.
Article in English | MEDLINE | ID: mdl-32780546

ABSTRACT

BACKGROUND: Waitlisted kidney transplant patients suffer from excess cardiovascular events. The benefits of regular cardiac investigations, potentially harmful and expensive, are unknown. We investigate the effectiveness of a cardio-renal MDT in managing high cardiovascular risk waitlisted transplant patients to prevent events and enable transplantation. METHODS: Clinical outcomes in waitlisted transplant candidates managed by our cardio-renal MDT protocol were compared against our standard protocol. Data compared include the transplantation, event, and death rates, cost of cardiac investigations and procedures, and graft, patient survival, and re-hospitalization rates in transplanted patients. RESULTS: 207 patients were studied (81 standard, 126 cardio-renal MDT). Over 2.7 years, the cardio-renal MDT protocol transplanted more patients than the standard group (35% vs 21%; P = .02). The managing cost per patient per year was higher in the standard group (£692 vs £610). This was driven by more echocardiograms and more tests per patient in the standard group (P < .01). There was no difference in adverse events or death. There was no difference in re-hospitalization, graft or patient survival rate in transplanted patients. CONCLUSIONS: Our cardio-renal MDT was effective in managing high-risk kidney transplant candidates with greater rates of transplantation and low rates of events at a lower cost.


Subject(s)
Cardiovascular Diseases , Kidney Failure, Chronic , Kidney Transplantation , Cardiovascular Diseases/etiology , Cardiovascular Diseases/prevention & control , Graft Survival , Heart Disease Risk Factors , Humans , Kidney Failure, Chronic/surgery , Risk Factors , Survival Rate
4.
Catheter Cardiovasc Interv ; 93(4): 751-757, 2019 03 01.
Article in English | MEDLINE | ID: mdl-30394657

ABSTRACT

OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Hemodynamics , Humans , Ireland , Male , Postoperative Complications/mortality , Postoperative Complications/therapy , Prosthesis Design , Registries , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United Kingdom
6.
Am J Cardiol ; 204: 383-391, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37579521

ABSTRACT

Cardiac troponins (cTn) are routinely measured for the diagnosis and prognosis of myocardial infarction (MI). The relation between troponin levels, estimated glomerular filtration rate (eGFR), postinfarction heart failure (HF), and mortality is unclear in patients with kidney impairment. This is a retrospective, cross-sectional study of patients presenting to the Emergency Department at a single tertiary center. Participants presenting with confirmed type I MI from January 1, 2019, to December 31, 2021, were analyzed from the Myocardial Ischemia National Audit Project database. Main outcomes were acute HF, measured using Killip class, and inpatient mortality. Peak cardiac troponin T (cTnT) level was a secondary outcome. Data on 2,815 patients (67±14 years, 28% female) were analyzed. Ordinal logistic regression analysis was used to test for predictors of increasing Killip class. Binary logistic regression was used to test for predictors of inpatient mortality. Analysis of a sub-sample matched for age and diabetes mellitus status showed increased mortality in patients with eGFR <60 ml/min/1.73 m2 (12.2% vs 4.4%, p <0.001). Multivariate predictors of acute HF included log-transformed peak cTnT, eGFR, body mass index (BMI), and diabetes mellitus status. Multivariate predictors of inpatient mortality included log-transformed peak cTnT, eGFR, age, BMI, and Killip class 3/4. On multivariate analysis, eGFR, ST-elevation MI diagnosis, BMI, male gender, diabetes mellitus status, and hypertension were all predictive of peak cTnT after MI. In conclusion, peak cTnT level and eGFR at presentation after MI are independent predictors of acute HF severity and death in patients with and without kidney impairment.


Subject(s)
Diabetes Mellitus , Heart Failure , Myocardial Infarction , Renal Insufficiency , Humans , Male , Female , Retrospective Studies , Cross-Sectional Studies , Heart Failure/diagnosis , Prognosis , Renal Insufficiency/epidemiology , Troponin T , Troponin , Kidney , Biomarkers
7.
Cardiovasc Revasc Med ; 51: 31-37, 2023 06.
Article in English | MEDLINE | ID: mdl-36740551

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat younger, lower-risk patients with bicuspid aortic valve (BAV). Patient-specific computer simulation may identify patients at risk for developing paravalvular regurgitation (PVR) and major conduction disturbance. Only limited prospective experience of this technology exist. We wished to describe our ongoing experience with patient-specific computer simulation. METHODS: Patients who were referred for consideration of TAVR with a self-expanding transcatheter heart valve (THV) and had BAV identified on pre-procedural cardiac computed tomography imaging underwent patient-specific computer simulation. The computer simulations were reviewed by the Heart Team and used to guide surgical or transcatheter treatment approaches and to aid in THV sizing and positioning. Clinical outcomes were recorded. RESULTS: Between May 2019 and May 2021, 16 patients with BAV were referred for consideration of TAVR with a self-expanding THV. Sievers Type 1 morphology was present in 15 patients and Type 0 in the remaining patient. Two patients were predicted to develop moderate-to-severe PVR with a TAVR procedure and these patients underwent successful surgical aortic valve replacement. In the remaining 14 patients, computer simulation was used to optimize THV sizing and positioning to minimise PVR and conduction disturbance. One patient with a low valve implantation depth developed moderate PVR and this complication was correctly predicted by the computer simulations. No patient required insertion of a new permanent pacemaker. CONCLUSION: Patient-specific computer simulation may be used to guide the most appropriate treatment modality for patients with BAV. The usage of computer simulation to guide THV sizing and positioning was associated with favourable clinical outcomes.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Bicuspid Aortic Valve Disease/etiology , Bicuspid Aortic Valve Disease/surgery , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Computer Simulation , Prospective Studies , Multidetector Computed Tomography , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome , Prosthesis Design
8.
J Cardiovasc Comput Tomogr ; 16(3): 254-261, 2022.
Article in English | MEDLINE | ID: mdl-34887238

ABSTRACT

BACKGROUND: Patient-specific computer simulation may predict the development of paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR). We hypothesised that patient-specific computer simulation might identify patients at risk for long-term adverse outcomes after TAVR. METHODS: A multi-centre retrospective study was performed on patients with symptomatic severe aortic stenosis who had undergone TAVR with a self-expanding transcatheter heart valve (THV). Pre-procedural cardiac computed tomography imaging was used to create finite element models of the aortic root. Finite element analysis (FEA) was performed in order to simulate the interaction between the THV and the native anatomy. The blood domain was extracted from the FEA output and computational fluid dynamics (CFD) simulation undertaken. Predicted PVR was recorded in the left ventricular outflow tract. Patients were classified into those where computer simulation predicted no significant PVR (predicted PVR from CFD <16.0 â€‹mL/s) and those where computer simulation predicted significant PVR (predicted PVR from CFD ≥16.0 â€‹mL/s). RESULTS: A total of 203 patients were included in the study. THVs implanted were CoreValve (n â€‹= â€‹20), Evolut R (n â€‹= â€‹90) and Evolut PRO (n â€‹= â€‹93). At 2 years, the Kaplan-Meier estimate of the rate of death from any cause was higher in the group where CFD simulation predicted significant PVR (35.8% vs. 16.3%; hazard ratio, 2.62; 95% confidence interval, 1.29 to 5.30; P â€‹= â€‹0.006 by log-rank test). CONCLUSIONS: Computer simulation may identify patients who are at a higher risk for death after TAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Computer Simulation , Humans , Predictive Value of Tests , Prosthesis Design , Retrospective Studies , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
9.
Struct Heart ; 6(3): 100010, 2022 Jul.
Article in English | MEDLINE | ID: mdl-37274548

ABSTRACT

Background: Patient-specific computer simulation may predict the development of conduction disturbance following transcatheter aortic valve replacement (TAVR). Validation of the computer simulations with current-generation devices has not been undertaken. Methods: A retrospective study was performed on patients who had undergone TAVR with a current-generation self-expanding transcatheter heart valve (THV). Preprocedural computed tomography imaging was used to create finite element models of the aortic root. Procedural contrast angiography was reviewed, and finite element analysis performed using a matching THV device size and implantation depth. A region of interest corresponding to the atrioventricular bundle and proximal left bundle branch was identified. The percentage of this area (contact pressure index [CPI]) and maximum contact pressure (CPMax) exerted by THV were recorded. Postprocedural electrocardiograms were reviewed, and major conduction disturbance was defined as the development of persistent left bundle branch block or high-degree atrioventricular block. Results: A total of 80 patients were included in the study. THVs were 23- to 29-mm Evolut PRO (n = 53) and 34-mm Evolut R (n = 27). Major conduction disturbance occurred in 27 patients (33.8%). CPI (28.3 ± 15.8 vs. 15.6 ± 11.2%; p < 0.001) and CPMax (0.51 ± 0.20 vs. 0.36 ± 0.24 MPa; p = 0.008) were higher in patients who developed major conduction disturbance. CPI (area under the receiver operating characteristic curve [AUC], 0.74; 95% CI, 0.63-0.86; p < 0.001) and CPMax (AUC, 0.69; 95% CI, 0.57-0.81; p = 0.006) demonstrated a discriminatory power to predict the development of major conduction disturbance. Conclusions: Patient-specific computer simulation may identify patients at risk for conduction disturbance after TAVR with current-generation self-expanding THVs.

11.
Interv Cardiol ; 16: e26, 2021 Apr.
Article in English | MEDLINE | ID: mdl-34721665

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is increasingly being used to treat younger, lower-risk patients, many of whom have bicuspid aortic valve (BAV). As TAVI begins to enter these younger patient cohorts, it is critical that clinical outcomes from TAVI in BAV are matched to those achieved by surgery. Therefore, the identification of patients who, on an anatomical basis, may not be suitable for TAVI, would be desirable. Furthermore, clinical outcomes of TAVI in BAV might be improved through improved transcatheter heart valve sizing and positioning. One potential solution to these challenges is patient-specific computer simulation. This review presents the methodology and clinical evidence surrounding patient-specific computer simulation of TAVI in BAV.

12.
Eur Heart J ; 30(14): 1728-35, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19429915

ABSTRACT

AIMS: Athletic activity is associated with electrocardiographic T-wave inversions in some adults, resembling those observed in cardiomyopathy. The prevalence and significance of T-wave inversions in adolescent athletes, the group most vulnerable to exercise-related sudden death from cardiomyopathy, is unknown. METHODS AND RESULTS: This study evaluated 1710 adolescent athletes and 400 healthy controls. Subjects with T-wave inversions underwent intensive cardiac investigations to identify a potential cause. There was no significant difference in the overall prevalence of T-wave inversions between athletes and controls (4 vs. 3%; P = 0.46). T-wave inversions in leads V1-V3 were largely confined to athletes and controls aged <16 years. Only 0.1% of athletes aged >or=16 years exhibited T-wave inversions beyond V2. T-wave inversions in the inferior and/or lateral leads and deep T-wave inversions occurred infrequently in athletes (1.5 and 0.8%, respectively) and were associated with a high prevalence of left ventricular hypertrophy or congenital cardiac anomalies. Despite intensive investigations, no athlete was diagnosed with a cardiomyopathy. CONCLUSIONS: T-wave inversions in V1-V3 are relatively common in athletes <16 years and probably represent the juvenile electrocardiogram pattern. In adolescent athletes, T-wave inversions beyond V2 if >or=16 years, T-wave inversions in the inferior/lateral leads and deep T-wave inversions in any lead are unusual, warranting further investigations for underlying cardiomyopathy.


Subject(s)
Cardiomyopathies/diagnosis , Death, Sudden, Cardiac , Sports/physiology , Adolescent , Cardiomyopathies/physiopathology , Cardiomyopathies/prevention & control , Case-Control Studies , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Echocardiography , Electrocardiography/instrumentation , Female , Humans , Male , United Kingdom , White People
13.
JACC Cardiovasc Interv ; 13(2): 184-192, 2020 01 27.
Article in English | MEDLINE | ID: mdl-31629752

ABSTRACT

OBJECTIVES: The aim of this study was to prospectively evaluate the clinical use of patient-specific computer simulation of transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) morphology. BACKGROUND: Patient-specific computer simulation of TAVR in BAV may predict important clinical outcomes, such as paravalvular regurgitation and conduction disturbance. METHODS: Between May 2018 and April 2019, all patients who were referred for TAVR who had BAV identified on work-up cardiac multidetector computed tomographic imaging prospectively underwent patient-specific computer simulation with a self-expanding transcatheter heart valve (THV) using TAVIguide technology. RESULTS: Nine patients were included in the study. Sievers classification was type 0 in 2 patients and type 1 in 7 patients. The simulations altered the treatment strategy in 8 patients (89%). The simulations suggested moderate to severe paravalvular regurgitation in 3 patients, who were referred for consideration of surgery. The remaining 6 patients underwent TAVR with a self-expanding THV. In 5 of these patients (83%), THV size and/or implantation depth was altered to minimize paravalvular regurgitation and/or conduction disturbance. In 1 patient, simulations suggested significant conduction disturbance after TAVR, and a permanent pacemaker was implanted before the procedure. Following treatment, all 9 patients had no to mild paravalvular regurgitation. The patient who had a pre-procedure permanent pacemaker implanted became pacing dependent, with underlying third-degree atrioventricular block. CONCLUSIONS: Patient-specific computer simulation of TAVR in BAV can be used to identify those patients where TAVR may be associated with unfavorable clinical outcomes. Patient-specific computer simulation may be useful to guide THV sizing and positioning for potential favorable clinical outcomes.


Subject(s)
Aortic Valve/abnormalities , Heart Valve Diseases/surgery , Models, Cardiovascular , Multidetector Computed Tomography , Patient-Specific Modeling , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/prevention & control , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/prevention & control , Bicuspid Aortic Valve Disease , Clinical Decision-Making , Female , Finite Element Analysis , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/mortality , Heart Valve Diseases/physiopathology , Heart Valve Prosthesis , Humans , Male , Predictive Value of Tests , Prospective Studies , Prosthesis Design , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
14.
Eur Heart J Case Rep ; 4(3): 1-5, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32617489

ABSTRACT

BACKGROUND: Troponin is a crucial biomarker for the diagnosis of an acute coronary syndrome (ACS). It rises in response to myocardial injury from significant acute myocardial ischaemia caused by obstructive coronary artery disease ['classical' myocardial infarction (MI)]. However, raised levels have also been noted in conditions not recognized as classical ACS. This may include MI with non-obstructed coronary arteries such as takotsubo cardiomyopathy and other acute or chronic conditions such as pulmonary embolus or chronic kidney disease. This is commonly labelled as a 'falsely elevated' troponin although there is some myocardial strain to explain the rise, such as an increase in cardiac oxygen demand. True 'falsely elevated' troponin, characterized by a persistent elevation in the absence of cardiac injury does occur and thought to be secondary to an immunoglobulin-troponin complex (macrotroponin). CASE SUMMARY: A 53-year-old gentleman with a background of diabetes, hypertension, hypercholesterolaemia, and hepatitis B was admitted with chest pain and persistently elevated cardiac troponin T (cTnT) levels. Investigations revealed unobstructed coronary arteries and a structurally normal, well-functioning heart. Subsequent biochemical analysis found the persistently elevated cTnT secondary to macrotroponin T. DISCUSSION: Macrotroponin, an immunoglobulin-troponin bound complex should be considered as a differential diagnosis when the biochemistry is not reflective of the clinical picture. Early recognition requires effective collaboration with the biochemistry laboratory for accurate diagnosis.

17.
JACC Cardiovasc Interv ; 10(3): 276-282, 2017 02 13.
Article in English | MEDLINE | ID: mdl-28183467

ABSTRACT

OBJECTIVES: The authors present the UK and Irish real-world learning curve experience of the Evolut R transcatheter heart valve. BACKGROUND: The Evolut R is a self-expanding, repositionable, and fully recapturable second-generation transcatheter heart valve with several novel design features to improve outcomes and reduce complications. METHODS: Clinical, procedural, and 30-day outcome data were prospectively collected for the first 264 patients to receive the Evolut R valve in the United Kingdom and Ireland. RESULTS: A total of 264 consecutive Evolut R implantations were performed across 9 centers. The mean age was 81.1 ± 7.8 years, and the mean logistic European System for Cardiac Operative Risk Evaluation score was 19.9 ± 13.7%. Procedural indications included aortic stenosis (72.0%), mixed aortic valve disease (17.4%), and failing aortic valve bioprostheses (10.6%). Conscious sedation was used in 39.8% of patients and transfemoral access in 93.6%. The procedural success rate was 91.3%, and paravalvular leak immediately after implantation was mild or less in 92.3%. Major complications were rare: cardiac tamponade in 0.4%, conversion to sternotomy in 0.8%, annular rupture in 0.0%, coronary occlusion in 0.8%, major vascular in 5.3%, acute kidney injury in 6.1%, new permanent pacemaker implantation in 14.7%, and procedure-related death in 0.0%. At 30-day follow-up, survival was 97.7%, paravalvular leak was mild or less in 92.3%, and the stroke rate was 3.8%. CONCLUSIONS: This registry represents the largest published real-world experience of the Evolut R valve. The procedural success rate was high and safety was excellent, comparable with previous studies of the Evolut R valve and other second-generation devices. The low rate of complications represents an improvement on first-generation devices.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Clinical Competence , Female , Humans , Ireland , Learning Curve , Male , Postoperative Complications/etiology , Prospective Studies , Prosthesis Design , Registries , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United Kingdom
18.
JACC Cardiovasc Interv ; 10(12): 1247-1253, 2017 06 26.
Article in English | MEDLINE | ID: mdl-28641846

ABSTRACT

OBJECTIVES: The authors report the incidence of pacemaker implantation up to hospital discharge and the factors influencing pacing rate following implantation of the LOTUS bioprosthesis (Boston Scientific, Natick, Massachusetts) in the United Kingdom. BACKGROUND: Transcatheter aortic valve replacement (TAVR) is associated with a significant need for permanent pacemaker implantation. Pacing rates vary according to the device used. The REPRISE II (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System) trial reported a pacing rate of 29% at 30 days after implantation of the LOTUS device. METHODS: Data were collected retrospectively on 228 patients who had the LOTUS device implanted between March 2013 and February 2015 across 10 centers in the United Kingdom. Twenty-seven patients (12%) had pacemakers implanted pre-procedure and were excluded from the analysis. RESULTS: Patients were aged 81.2 ± 7.7 years; 50.7% were male. The mean pre-procedural QRS duration was 101.7 ± 20.4 ms. More than one-half of the cohort (n = 111, 55%) developed new left bundle branch block (LBBB) following the procedure. Permanent pacemakers were implanted in 64 patients (32%) with a median time to insertion of 3.0 ± 3.4 days. Chief indications for pacing were atrioventricular (AV) block (n = 46, 72%), or LBBB with 1st degree AV block (n = 11, 17%). Amongst those who received a pacemaker following TAVR the pre-procedural electrocardiogram findings included: No conduction disturbance (n = 41, 64%); 1st degree AV block (n = 10, 16%); right bundle branch block (n = 6, 9%) and LBBB (n = 5, 8%). LBBB (but not permanent pacemaker) occurred more frequently in patients who had balloon aortic valvuloplasty before TAVR (odds ratio [OR]: 1.25; p = 0.03). Pre-procedural conduction abnormality (composite of 1st degree AV block, hemiblock, right bundle branch block, LBBB) was independently associated with the need for permanent pacemaker (OR: 2.54; p = 0.048). The absence of aortic valve calcification was also associated with a higher pacing rate (OR: 0.55; p = 0.031). Multivariate regression analysis did not show an independent association between depth of implant, valve oversizing, balloon post-dilatation, and the need for pacing post-procedure. CONCLUSIONS: Following implantation of the repositionable LOTUS valve, 55% of patients developed LBBB and 32% of patients required a pacemaker during their index hospital admission. Patients with pre-procedural conduction disturbance and non-calcified aortic valves were more likely to need pacing. No other anatomic features were identified with increased pacing requirement with the LOTUS device.


Subject(s)
Atrioventricular Block/therapy , Bundle-Branch Block/therapy , Cardiac Pacing, Artificial , Heart Conduction System/physiopathology , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement/adverse effects , Action Potentials , Aged , Aged, 80 and over , Atrioventricular Block/diagnosis , Atrioventricular Block/etiology , Atrioventricular Block/physiopathology , Balloon Valvuloplasty , Bundle-Branch Block/diagnosis , Bundle-Branch Block/etiology , Bundle-Branch Block/physiopathology , Electrocardiography , Female , Heart Rate , Humans , Logistic Models , Male , Multivariate Analysis , Odds Ratio , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , United Kingdom
19.
JACC Cardiovasc Interv ; 9(4): 367-372, 2016 Feb 22.
Article in English | MEDLINE | ID: mdl-26892082

ABSTRACT

OBJECTIVES: This study sought to present the U.K. experience to date with the second-generation LOTUS bioprosthesis (Boston Scientific, Natick, Massachusetts). BACKGROUND: First-generation transcatheter aortic valves have limitations. Second-generation repositionable valves may improve on some of those limitations. METHODS: Prospectively collected data relating to procedural and in-hospital outcome was analyzed from 10 implantation centers in the United Kingdom. RESULTS: Implants in 228 patients age 81.4 ± 7.6 years were studied; 53.5% were male. Mean logistic EuroScore was 17.5 ± 12.4. One hundred eighty-seven (82.0%) were undertaken for aortic stenosis, 7 (3.1%) for aortic regurgitation, and 34 (14.9%) for mixed aortic valve disease. A total of 67.1% of cases were done under local anesthetic and/or sedation with transfemoral access in 94.7% and transaortic in 5.3%. Three device sizes were used: 23 mm (n = 66, 28.9%), 25 mm (n = 39, 17.1%), and 27 mm (n = 123, 53.9%). The valve was successfully deployed in 99.1% of procedures. After implantation, the mean aortic gradient was 11.4 ± 5.4 mm Hg and aortic valve area 1.6 ± 0.5 cm(2). In-hospital mortality was 1.8% (n = 4). Complications included cardiac tamponade (1.8%), conversion to sternotomy (1.3%), stroke (3.9%), vascular access-related (7.0%), and acute kidney injury (7.9%). The incidence of moderate/severe aortic regurgitation was 0.8% (n = 2). A total of 31.8% of patients required new permanent pacemaker implantation. CONCLUSIONS: This analysis represents the largest published series on use of the LOTUS valve. Outcomes using this valve are excellent. In-hospital mortality is very low. Complication rates are low, and the LOTUS valve improves on first-generation valves, particularly with regard to residual aortic regurgitation.


Subject(s)
Aortic Valve Stenosis/therapy , Aortic Valve , Cardiac Catheterization/instrumentation , Catheterization, Peripheral/methods , Femoral Artery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Cardiac Pacing, Artificial , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Hemodynamics , Hospital Mortality , Humans , Male , Prosthesis Design , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , United Kingdom
20.
J Am Coll Cardiol ; 40(8): 1431-6, 2002 Oct 16.
Article in English | MEDLINE | ID: mdl-12392833

ABSTRACT

OBJECTIVES: The present study was undertaken to define physiologic limits of left ventricular hypertrophy in elite adolescent athletes. BACKGROUND: Systematic sports training may cause increased left ventricular wall thickness (LVWT), creating uncertainty regarding the differential diagnosis of athlete's heart from hypertrophic cardiomyopathy (HCM). This distinction is crucial because HCM is responsible for about one-third of all sudden deaths in young athletes. Echocardiographic data defining athlete's heart are limited largely to adults, with little information specifically in adolescent athletes (14 to 18 years old), for whom the risk of sudden death from HCM is highest. METHODS: Seven hundred and twenty elite adolescent athletes (75% male) aged 15.7 +/- 1.4 years participating in ball, racket, and endurance sports and 250 healthy sedentary controls of similar age, gender, and body surface area underwent echocardiography. RESULTS: Compared with controls, athletes had greater absolute LVWT (9.5 +/- 1.7 mm vs. 8.4 +/- 1.4 mm; p < 0.0001). Maximal LVWT exceeded predicted upper limits in 38 athletes (5%); however, no female athlete had a LVWT >11 mm and only three trained male athletes had absolute LVWT >12 mm (0.4%). Each of the 38 athletes with a LVWT exceeding predicted limits also showed enlarged left ventricular cavity dimension (54.4 +/- 2.1 mm; range 52 to 60 mm). CONCLUSIONS: Trained adolescent athletes demonstrated greater absolute LVWT compared with nonathletes. Only a small proportion of athletes exhibited a LVWT exceeding upper limits, very rarely >12 mm, and then always with chamber enlargement. Hypertrophic cardiomyopathy should be considered strongly in any trained adolescent male athlete with LVWT >12 mm (females >11 mm) and nondilated left ventricle.


Subject(s)
Cardiomyopathy, Hypertrophic/pathology , Heart Ventricles/pathology , Sports , Adolescent , Cardiomyopathy, Hypertrophic/physiopathology , Female , Humans , Hypertrophy, Left Ventricular/physiopathology , Male , Sex Factors
SELECTION OF CITATIONS