Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
Ear Hear ; 44(4): 740-750, 2023.
Article in English | MEDLINE | ID: mdl-36631948

ABSTRACT

OBJECTIVES: This study compared the measurement of the acoustic stapedius reflex threshold (ART) obtained using a traditional method with that obtained using an automated adaptive wideband (AAW) method. Participants included three groups of adults with normal hearing (NH), mild sensorineural hearing loss (SNHL), or moderate SNHL. The purpose of the study was to compare ARTs for the three groups and to determine which method had the best performance in detecting SNHL. DESIGN: Ipsilateral and contralateral ARTs were obtained using 0.5, 1, and 2 kHz tonal activators, and broadband noise (BBN) activators on a traditional admittance system (Clinical) at tympanometric peak pressures (TPP) and on an experimental wideband system using an AAW method at both ambient pressure and TPP. ART data previously reported for 39 NH adults with a mean age of 47.7 years were compared with data for 25 participants with mild SNHL with a mean age of 63.8 years, and 20 participants with moderate SNHL with a mean age of 65.7 years. Differences in ARTs between the normal-hearing and SNHL groups for the three methods were examined using a General Linear Model Repeated-Measures test. A receiver operating characteristic curve (ROC) analysis was also used to determine the ability of an ART test to detect SNHL. RESULTS: For the 0.5 kHz activator condition, there were no significant group mean differences in ART between NH and SNHL groups for either ipsilateral or contralateral activator presentation modes for the Clinical or AAW methods. There were significant group mean differences for the 1 and 2 kHz tonal activators and BBN activator for both ipsilateral and contralateral modes with greater differences in ART between groups for the AAW method than the Clinical method. In these conditions, the mean ART was lower for the AAW tests relative to the Clinical test. The greatest difference between groups was for the ipsilateral AAW tests for the comparison of NH with moderate SNHL for the BBN activator. This difference was approximately 20 dB for the AAW tests and 8 dB for the Clinical test. The ROC analysis showed that the area under the ROC curve (AUC) increased with the frequency of the activator stimulus and with the degree of hearing loss and was maximal for the BBN activator for both the AAW and Clinical methods for both ipsilateral and contralateral presentations. CONCLUSIONS: For ipsilateral and contralateral ART tests for activator frequencies above 0.5 kHz and BBN, listeners with SNHL generally had elevated ARTs compared with those with NH. The AAW method resulted in greater differences between SNHL groups and NH than the Clinical method. The AUC for detecting SNHL also increased with activator frequency and degree of hearing loss and was greatest for the BBN activator for the AAW method in both the ambient and TPP conditions. The results are encouraging for the use of an AAW ART method for the assessment of individuals with SNHL.


Subject(s)
Deafness , Hearing Loss, Sensorineural , Hearing Loss , Humans , Adult , Middle Aged , Aged , Stapedius , Auditory Threshold , Hearing Loss, Sensorineural/diagnosis , Acoustic Impedance Tests , Acoustics , Hearing , Reflex , Reflex, Acoustic
2.
Ear Hear ; 42(3): 547-557, 2021.
Article in English | MEDLINE | ID: mdl-33156125

ABSTRACT

OBJECTIVE: Wideband absorbance and absorbed power were evaluated in a group of subjects with surgically confirmed otosclerosis (Oto group), mean age 51.6 years. This is the first use of absorbed power in the assessment of middle ear disorders. Results were compared with control data from two groups of adults, one with normal hearing (NH group) mean age of 31 years, and one that was age- and sex-matched with the Oto group and had sensorineural hearing loss (SNHL group). The goal was to assess group differences using absorbance and absorbed power, to determine test performance in detecting otosclerosis, and to evaluate preoperative and postoperative test results. DESIGN: Audiometric and wideband tests were performed over frequencies up to 8 kHz. The three groups were compared on wideband tests using analysis of variance to assess group mean differences. Receiver operating characteristic (ROC) curve analysis was also used to assess test accuracy at classifying ears as belonging to the Oto or control groups using the area under the ROC curve (AUC). A longitudinal design was used to compare preoperative and postoperative results at 3 and 6 months. RESULTS: There were significant mean differences in the wideband parameters between the Oto and control groups with generally lower absorbance and absorbed power for the Oto group at ambient and tympanometric peak pressure (TPP) depending on frequency. The SNHL group had more significant differences with the Oto group than did the NH group in the high frequencies for absorbed power at ambient pressure and tympanometric absorbed power at TPP, as well as for the tympanometric tails. The greatest accuracy for classifying ears as being in the Oto group or a control group was for absorbed power at ambient pressure at 0.71 kHz with an AUC of 0.81 comparing the Oto and NH groups. The greatest accuracy for an absorbance measure was for the comparison between the Oto and NH groups for the peak-to-negative tail condition with an AUC of 0.78. In contrast, the accuracy for classifying ears into the control or Oto groups for static acoustic admittance at 226 Hz was near chance performance, which is consistent with previous findings. There were significant mean differences between preoperative and postoperative tests for absorbance and absorbed power. CONCLUSIONS: Consistent with previous studies, wideband absorbance showed better sensitivity for detecting the effects of otosclerosis on middle ear function than static acoustic admittance at 226 Hz. This study showed that wideband absorbed power is similarly sensitive and may perform even better in some instances than absorbance at classifying ears as having otosclerosis. The use of a group that was age- and sex-matched to the Oto group generally resulted in greater differences between groups in the high frequencies for absorbed power, suggesting that age-related norms in adults may be useful for the wideband clinical applications. Absorbance and absorbed power appear useful for monitoring changes in middle ear function following surgery for otosclerosis.


Subject(s)
Hearing Loss, Sensorineural , Otosclerosis , Acoustic Impedance Tests , Adult , Audiometry , Ear, Middle , Humans , Middle Aged
3.
Ear Hear ; 39(6): 1075-1090, 2018.
Article in English | MEDLINE | ID: mdl-29517520

ABSTRACT

OBJECTIVES: The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the presence of conductive HL (CHL), sensorineural HL (SNHL), and mixed HL (MHL). Wideband ambient absorbance was also measured and compared among the HL types. DESIGN: This is a prospective, longitudinal study of 279 infants with verified NH and HL, including conductive, sensorineural, and mixed types that were enrolled from a well-baby nursery and two neonatal intensive care units in Cincinnati, Ohio. At approximately 1 month of age, DPOAEs (1-8 kHz), wideband absorbance (0.25-8 kHz), and air and bone conduction diagnostic tone burst auditory brainstem response (0.5-4 kHz) thresholds were measured. Hearing status was verified at approximately 9 months of age with visual reinforcement audiometry (0.5-4 kHz). Auditory brainstem response air conduction thresholds were used to assign infants to an NH or HL group, and the efficacy of DPOAE data to classify ears as NH or HL was analyzed using receiver operating characteristic (ROC) curves. Two summary statistics of the ROC curve were calculated: the area under the ROC curve and the point of symmetry on the curve at which the sensitivity and specificity were equal. DPOAE level and signal to noise ratio cutoff values were defined at each frequency as the symmetry point on their respective ROC curve, and DPOAE results were combined across frequency in a multifrequency analysis to predict the presence of HL. RESULTS: Single-frequency test performance of DPOAEs was best at mid to high frequencies (3-8 kHz) with intermediate performance at 1.5 and 2 kHz and chance performance at 1 kHz. Infants with a conductive component to their HL (CHL and MHL combined) displayed significantly lower ambient absorbance values than the NH group. No differences in ambient absorbance were found between the NH and SNHL groups. Multifrequency analysis resulted in the best prediction of HL for the SNHL/MHL group with poorer sensitivity values when infants with CHL were included. CONCLUSIONS: Clinical interpretation of DPOAEs in infants can be improved by using age-appropriate normative ranges and optimized cutoff values. DPOAE interpretation is most predictive at higher F2 test frequencies in young infants (2-8 kHz) due to poor test performance at 1 to 1.5 kHz. Multifrequency rules can be used to improve sensitivity while balancing specificity. Last, a sensitive middle ear measure such as wideband absorbance should be included in the test battery to assess possibility of a conductive component to the HL.


Subject(s)
Hearing Loss/diagnosis , Otoacoustic Emissions, Spontaneous/physiology , Analysis of Variance , Area Under Curve , Evoked Potentials, Auditory, Brain Stem/physiology , Female , Hearing/physiology , Hearing Loss/physiopathology , Humans , Infant , Infant, Newborn , Longitudinal Studies , Male , Reference Values
4.
Ear Hear ; 39(5): 863-873, 2018.
Article in English | MEDLINE | ID: mdl-29369290

ABSTRACT

OBJECTIVES: The purpose of this study was to describe normal characteristics of distortion product otoacoustic emission (DPOAE) signal and noise level in a group of newborns and infants with normal hearing followed longitudinally from birth to 15 months of age. DESIGN: This is a prospective, longitudinal study of 231 infants who passed newborn hearing screening and were verified to have normal hearing. Infants were enrolled from a well-baby nursery and two neonatal intensive care units (NICUs) in Cincinnati, OH. Normal hearing was confirmed with threshold auditory brainstem response and visual reinforcement audiometry. DPOAEs were measured in up to four study visits over the first year after birth. Stimulus frequencies f1 and f2 were used with f2/f1 = 1.22, and the DPOAE was recorded at frequency 2f1-f2. A longitudinal repeated-measure linear mixed model design was used to study changes in DPOAE level and noise level as related to age, middle ear transfer, race, and NICU history. RESULTS: Significant changes in the DPOAE and noise levels occurred from birth to 12 months of age. DPOAE levels were the highest at 1 month of age. The largest decrease in DPOAE level occurred between 1 and 5 months of age in the mid to high frequencies (2 to 8 kHz) with minimal changes occurring between 6, 9, and 12 months of age. The decrease in DPOAE level was significantly related to a decrease in wideband absorbance at the same f2 frequencies. DPOAE noise level increased only slightly with age over the first year with the highest noise levels in the 12-month-old age range. Minor, nonsystematic effects for NICU history, race, and gestational age at birth were found, thus these results were generalizable to commonly seen clinical populations. CONCLUSIONS: DPOAE levels were related to wideband middle ear absorbance changes in this large sample of infants confirmed to have normal hearing at auditory brainstem response and visual reinforcement audiometry testing. This normative database can be used to evaluate clinical results from birth to 1 year of age. The distributions of DPOAE level and signal to noise ratio data reported herein across frequency and age in normal-hearing infants who were healthy or had NICU histories may be helpful to detect the presence of hearing loss in infants.


Subject(s)
Ear, Middle/physiology , Hearing/physiology , Otoacoustic Emissions, Spontaneous , Audiometry/methods , Cochlea/physiology , Female , Hearing Tests , Humans , Infant , Infant, Newborn , Longitudinal Studies , Male , Noise , Reference Values
5.
Ear Hear ; 39(1): 69-84, 2018.
Article in English | MEDLINE | ID: mdl-28708814

ABSTRACT

OBJECTIVES: The goal of this study was to investigate the use of transient-evoked otoacoustic emissions (TEOAEs) and middle ear absorbance measurements to monitor auditory function in patients with cystic fibrosis (CF) receiving ototoxic medications. TEOAEs were elicited with a chirp stimulus using an extended bandwidth (0.71 to 8 kHz) to measure cochlear function at higher frequencies than traditional TEOAEs. Absorbance over a wide bandwidth (0.25 to 8 kHz) provides information on middle ear function. The combination of these time-efficient measurements has the potential to identify early signs of ototoxic hearing loss. DESIGN: A longitudinal study design was used to monitor the hearing of 91 patients with CF (median age = 25 years; age range = 15 to 63 years) who received known ototoxic medications (e.g., tobramycin) to prevent or treat bacterial lung infections. Results were compared to 37 normally hearing young adults (median age = 32.5 years; age range = 18 to 65 years) without a history of CF or similar treatments. Clinical testing included 226-Hz tympanometry, pure-tone air-conduction threshold testing from 0.25 to 16 kHz and bone conduction from 0.25 to 4 kHz. Experimental testing included wideband absorbance at ambient and tympanometric peak pressure and TEOAEs in three stimulus conditions: at ambient pressure and at tympanometric peak pressure using a chirp stimulus with constant incident pressure level across frequency and at ambient pressure using a chirp stimulus with constant absorbed sound power across frequency. RESULTS: At the initial visit, behavioral audiometric results indicated that 76 of the 157 ears (48%) from patients with CF had normal hearing, whereas 81 of these ears (52%) had sensorineural hearing loss for at least one frequency. Seven ears from four patients had a confirmed behavioral change in hearing threshold for ≥3 visits during study participation. Receiver operating characteristic curve analyses demonstrated that all three TEOAE conditions were useful for distinguishing CF ears with normal hearing from ears with sensorineural hearing loss, with an area under the receiver operating characteristic curve values ranging from 0.78 to 0.92 across methods for frequency bands from 2.8 to 8 kHz. Case studies are presented to illustrate the relationship between changes in audiometric thresholds, TEOAEs, and absorbance across study visits. Absorbance measures permitted identification of potential middle ear dysfunction at 5.7 kHz in an ear that exhibited a temporary hearing loss. CONCLUSIONS: The joint use of TEOAEs and absorbance has the potential to explain fluctuations in audiometric thresholds due to changes in cochlear function, middle ear function, or both. These findings are encouraging for the joint use of TEOAE and wideband absorbance objective tests for monitoring ototoxicity, particularly, in patients who may be too ill for behavioral hearing tests. Additional longitudinal studies are needed in a larger number of CF patients receiving ototoxic drugs to further evaluate the clinical utility of these measures in an ototoxic monitoring program.


Subject(s)
Aminoglycosides/adverse effects , Anti-Bacterial Agents/adverse effects , Cystic Fibrosis/complications , Cytotoxins/adverse effects , Hearing Loss, Sensorineural/diagnosis , Otoacoustic Emissions, Spontaneous , Adolescent , Adult , Aminoglycosides/therapeutic use , Anti-Bacterial Agents/therapeutic use , Audiometry , Auditory Threshold , Cystic Fibrosis/drug therapy , Ear, Middle/physiopathology , Female , Hearing Loss, Sensorineural/chemically induced , Humans , Longitudinal Studies , Male , Middle Aged , Young Adult
6.
J Acoust Soc Am ; 143(1): 399, 2018 01.
Article in English | MEDLINE | ID: mdl-29390789

ABSTRACT

Transient-evoked otoacoustic emission (TEOAE) responses were measured in normal-hearing adult ears over frequencies from 0.7 to 8 kHz, and analyzed with reflectance/admittance data to measure absorbed sound power and the tympanometric peak pressure (TPP). The mean TPP was close to ambient. TEOAEs were measured in the ear canal at ambient pressure, TPP, and fixed air pressures from 150 to -200 daPa. Both click and chirp stimuli were used to elicit TEOAEs, in which the incident sound pressure level was constant across frequency. TEOAE levels were similar at ambient and TPP, and for frequencies from 0.7 to 2.8 kHz decreased with increasing positive and negative pressures. At 4-8 kHz, TEOAE levels were larger at positive pressures. This asymmetry is possibly related to changes in mechanical transmission through the ossicular chain. The mean TEOAE group delay did not change with pressure, although small changes were observed in the mean instantaneous frequency and group spread. Chirp TEOAEs measured in an adult ear with Eustachian tube dysfunction and TPP of -165 daPa were more robust at TPP than at ambient. Overall, results demonstrate the feasibility and clinical potential of measuring TEOAEs at fixed pressures in the ear canal, which provide additional information relative to TEOAEs measured at ambient pressure.


Subject(s)
Acoustic Stimulation/methods , Auditory Pathways/physiology , Cochlea/physiology , Ear Canal/physiology , Hearing Tests/methods , Otoacoustic Emissions, Spontaneous , Adult , Ear Diseases/diagnosis , Ear Diseases/physiopathology , Eustachian Tube/physiopathology , Female , Humans , Male , Predictive Value of Tests , Pressure , Sound , Young Adult
7.
Ear Hear ; 38(4): 507-520, 2017.
Article in English | MEDLINE | ID: mdl-28437273

ABSTRACT

OBJECTIVES: An important clinical application of transient-evoked otoacoustic emissions (TEOAEs) is to evaluate cochlear outer hair cell function for the purpose of detecting sensorineural hearing loss (SNHL). Double-evoked TEOAEs were measured using a chirp stimulus, in which the stimuli had an extended frequency range compared to clinical tests. The present study compared TEOAEs recorded using an unweighted stimulus presented at either ambient pressure or tympanometric peak pressure (TPP) in the ear canal and TEOAEs recorded using a power-weighted stimulus at ambient pressure. The unweighted stimulus had approximately constant incident pressure magnitude across frequency, and the power-weighted stimulus had approximately constant absorbed sound power across frequency. The objective of this study was to compare TEOAEs from 0.79 to 8 kHz using these three stimulus conditions in adults to assess test performance in classifying ears as having either normal hearing or SNHL. DESIGN: Measurements were completed on 87 adult participants. Eligible participants had either normal hearing (N = 40; M F = 16 24; mean age = 30 years) or SNHL (N = 47; M F = 20 27; mean age = 58 years), and normal middle ear function as defined by standard clinical criteria for 226-Hz tympanometry. Clinical audiometry, immittance, and an experimental wideband test battery, which included reflectance and TEOAE tests presented for 1-min durations, were completed for each ear on all participants. All tests were then repeated 1 to 2 months later. TEOAEs were measured by presenting the stimulus in the three stimulus conditions. TEOAE data were analyzed in each hearing group in terms of the half-octave-averaged signal to noise ratio (SNR) and the coherence synchrony measure (CSM) at frequencies between 1 and 8 kHz. The test-retest reliability of these measures was calculated. The area under the receiver operating characteristic curve (AUC) was measured at audiometric frequencies between 1 and 8 kHz to determine TEOAE test performance in distinguishing SNHL from normal hearing. RESULTS: Mean TEOAE SNR was ≥8.7 dB for normal-hearing ears and ≤6 dB for SNHL ears for all three stimulus conditions across all frequencies. Mean test-retest reliability of TEOAE SNR was ≤4.3 dB for both hearing groups across all frequencies, although it was generally less (≤3.5 dB) for lower frequencies (1 to 4 kHz). AUCs were between 0.85 and 0.94 for all three TEOAE conditions at all frequencies, except for the ambient TEOAE condition at 2 kHz (0.82) and for all TEOAE conditions at 5.7 kHz with AUCs between 0.78 and 0.81. Power-weighted TEOAE AUCs were significantly higher (p < 0.05) than ambient TEOAE AUCs at 2 and 2.8 kHz, as was the TPP TEOAE AUC at 2.8 kHz when using CSM as the classifier variable. CONCLUSIONS: TEOAEs evaluated in an ambient condition, at TPP and in a power-weighted stimulus condition, had good test performance in identifying ears with SNHL based on SNR and CSM in the frequency range from 1 to 8 kHz and showed good test-retest reliability. Power-weighted TEOAEs showed the best test performance at 2 and 2.8 kHz. These findings are encouraging as a potential objective clinical tool to identify patients with cochlear hearing loss.


Subject(s)
Hair Cells, Auditory, Outer , Hearing Loss, Sensorineural/physiopathology , Otoacoustic Emissions, Spontaneous , Acoustic Stimulation/methods , Adult , Area Under Curve , Case-Control Studies , Female , Hearing Loss, Sensorineural/diagnosis , Humans , Male , Middle Aged , ROC Curve , Reproducibility of Results , Signal-To-Noise Ratio
8.
Ear Hear ; 38(3): e142-e160, 2017.
Article in English | MEDLINE | ID: mdl-28045835

ABSTRACT

OBJECTIVES: Wideband acoustic immittance (WAI) measures such as pressure reflectance, parameterized by absorbance and group delay, equivalent admittance at the tympanic membrane (TM), and acoustic stapedius reflex threshold (ASRT) describe middle ear function across a wide frequency range, compared with traditional tests employing a single frequency. The objective of this study was to obtain normative data using these tests for a group of normal-hearing adults and investigate test-retest reliability using a longitudinal design. DESIGN: A longitudinal prospective design was used to obtain normative test and retest data on clinical and WAI measures. Subjects were 13 males and 20 females (mean age = 26 years). Inclusion criteria included normal audiometry and clinical immittance. Subjects were tested on two separate visits approximately 1 month apart. Reflectance and equivalent admittance at the TM were measured from 0.25 to 8.0 kHz under three conditions: at ambient pressure in the ear canal and with pressure sweeps from positive to negative pressure (downswept) and negative to positive pressure (upswept). Equivalent admittance at the TM was calculated using admittance measurements at the probe tip that were adjusted using a model of sound transmission in the ear canal and acoustic estimates of ear-canal area and length. Wideband ASRTs were measured at tympanometric peak pressure (TPP) derived from the average TPP of downswept and upswept tympanograms. Descriptive statistics were obtained for all WAI responses, and wideband and clinical ASRTs were compared. RESULTS: Mean absorbance at ambient pressure and TPP demonstrated a broad band-pass pattern typical of previous studies. Test-retest differences were lower for absorbance at TPP for the downswept method compared with ambient pressure at frequencies between 1.0 and 1.26 kHz. Mean tympanometric peak-to-tail differences for absorbance were greatest around 1.0 to 2.0 kHz and similar for positive and negative tails. Mean group delay at ambient pressure and at TPP were greatest between 0.32 and 0.6 kHz at 200 to 300 µsec, reduced at frequencies between 0.8 and 1.5 kHz, and increased above 1.5 kHz to around 150 µsec. Mean equivalent admittance at the TM had a lower level for the ambient method than at TPP for both sweep directions below 1.2 kHz, but the difference between methods was only statistically significant for the comparison between the ambient method and TPP for the upswept tympanogram. Mean equivalent admittance phase was positive at all frequencies. Test-retest reliability of the equivalent admittance level ranged from 1 to 3 dB at frequencies below 1.0 kHz, but increased to 8 to 9 dB at higher frequencies. The mean wideband ASRT for an ipsilateral broadband noise activator was 12 dB lower than the clinical ASRT, but had poorer reliability. CONCLUSIONS: Normative data for the WAI test battery revealed minor differences for results at ambient pressure compared with tympanometric methods at TPP for reflectance, group delay, and equivalent admittance level at the TM for subjects with middle ear pressure within ±100 daPa. Test-retest reliability was better for absorbance at TPP for the downswept tympanogram compared with ambient pressure at frequencies around 1.0 kHz. Large peak-to-tail differences in absorbance combined with good reliability at frequencies between about 0.7 and 3.0 kHz suggest that this may be a sensitive frequency range for interpreting absorbance at TPP. The mean wideband ipsilateral ASRT was lower than the clinical ASRT, consistent with previous studies. Results are promising for the use of a wideband test battery to evaluate middle ear function.


Subject(s)
Cochlea/physiology , Ear, Middle/physiology , Stapedius/physiology , Tympanic Membrane/physiology , Acoustic Impedance Tests , Acoustics , Adult , Audiometry , Female , Humans , Male , Middle Aged , Prospective Studies , Reference Values , Reflex/physiology , Reproducibility of Results , Young Adult
9.
J Acoust Soc Am ; 141(1): 499, 2017 01.
Article in English | MEDLINE | ID: mdl-28147608

ABSTRACT

Human ear-canal properties of transient acoustic stimuli are contrasted that utilize measured ear-canal pressures in conjunction with measured acoustic pressure reflectance and admittance. These data are referenced to the tip of a probe snugly inserted into the ear canal. Promising procedures to calibrate across frequency include stimuli with controlled levels of incident pressure magnitude, absorbed sound power, and forward pressure magnitude. An equivalent pressure at the eardrum is calculated from these measured data using a transmission-line model of ear-canal acoustics parameterized by acoustically estimated ear-canal area at the probe tip and length between the probe tip and eardrum. Chirp stimuli with constant incident pressure magnitude and constant absorbed sound power across frequency were generated to elicit transient-evoked otoacoustic emissions (TEOAEs), which were measured in normal-hearing adult ears from 0.7 to 8 kHz. TEOAE stimuli had similar peak-to-peak equivalent sound pressure levels across calibration conditions. Frequency-domain TEOAEs were compared using signal level, signal-to-noise ratio (SNR), coherence synchrony modulus (CSM), group delay, and group spread. Time-domain TEOAEs were compared using SNR, CSM, instantaneous frequency and instantaneous bandwidth. Stimuli with constant incident pressure magnitude or constant absorbed sound power across frequency produce generally similar TEOAEs up to 8 kHz.


Subject(s)
Acoustic Stimulation/methods , Acoustics/instrumentation , Cochlea/physiology , Ear Canal/physiology , Otoacoustic Emissions, Spontaneous , Sound , Adult , Female , Humans , Male , Middle Aged , Pressure , Signal Processing, Computer-Assisted , Time Factors , Transducers, Pressure , Young Adult
10.
J Acoust Soc Am ; 140(3): 1949, 2016 09.
Article in English | MEDLINE | ID: mdl-27914441

ABSTRACT

Transient-evoked otoacoustic emission (TEOAE) responses (0.7-8 kHz) were measured in normal-hearing adult ears using click stimuli and chirps whose local frequency increased or decreased linearly with time over the stimulus duration. Chirp stimuli were created by allpass filtering a click with relatively constant incident pressure level over frequency. Chirp TEOAEs were analyzed as a nonlinear residual signal by inverse allpass filtering each chirp response into an equivalent click response. Multi-window spectral and temporal averaging reduced noise levels compared to a single-window average. Mean TEOAE levels using click and chirp stimuli were similar with respect to their standard errors in adult ears. TEOAE group delay, group spread, instantaneous frequency, and instantaneous bandwidth were similar overall for chirp and click conditions, except for small differences showing nonlinear interactions differing across stimulus conditions. These results support the theory of a similar generation mechanism on the basilar membrane for both click and chirp conditions based on coherent reflection within the tonotopic region. TEOAE temporal fine structure was invariant across changes in stimulus level, which is analogous to the intensity invariance of click-evoked basilar-membrane displacement data.


Subject(s)
Acoustic Stimulation , Basilar Membrane , Female , Humans , Male , Otoacoustic Emissions, Spontaneous
11.
J Acoust Soc Am ; 138(6): 3625-53, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26723319

ABSTRACT

Procedures are described to measure acoustic reflectance and admittance in human adult and infant ears at frequencies from 0.2 to 8 kHz. Transfer functions were measured at ambient pressure in the ear canal, and as down- or up-swept tympanograms. Acoustically estimated ear-canal area was used to calculate ear reflectance, which was parameterized by absorbance and group delay over all frequencies (and pressures), with substantial data reduction for tympanograms. Admittance measured at the probe tip in adults was transformed into an equivalent admittance at the eardrum using a transmission-line model for an ear canal with specified area and ear-canal length. Ear-canal length was estimated from group delay around the frequency above 2 kHz of minimum absorbance. Illustrative measurements in ears with normal function are described for an adult, and two infants at 1 month of age with normal hearing and a conductive hearing loss. The sensitivity of this equivalent eardrum admittance was calculated for varying estimates of area and length. Infant-ear patterns of absorbance peaks aligned in frequency with dips in group delay were explained by a model of resonant canal-wall mobility. Procedures will be applied in a large study of wideband clinical diagnosis and monitoring of middle-ear and cochlear function.


Subject(s)
Acoustic Impedance Tests , Acoustics , Ear Canal/physiology , Hearing Loss, Conductive/diagnosis , Hearing , Sound , Acoustic Stimulation , Adult , Age Factors , Air Pressure , Ear Canal/anatomy & histology , Hearing Loss, Conductive/physiopathology , Humans , Infant , Male , Models, Biological , Motion , Predictive Value of Tests , Pressure , Time Factors
12.
Int J Audiol ; 51(12): 880-91, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23072655

ABSTRACT

OBJECTIVE: This study tested the hypothesis that wideband aural absorbance predicts conductive hearing loss (CHL) in children medically classified as having otitis media with effusion. DESIGN: Absorbance was measured in the ear canal over frequencies from 0.25 to 8 kHz at ambient pressure or as a swept tympanogram. CHL was defined using criterion air-bone gaps of 20, 25, and 30 dB at octaves from 0.25 to 4 kHz. A likelihood-ratio predictor of CHL was constructed across frequency for ambient absorbance, and across frequency and pressure for absorbance tympanometry. Performance was evaluated at individual frequencies and for any frequency at which a CHL was present. STUDY SAMPLE: Absorbance and conventional 0.226-kHz tympanograms were measured in children of age three to eight years with CHL and with normal hearing. RESULTS: Absorbance was smaller at frequencies above 0.7 kHz in the CHL group than the control group. Based on the area under the receiver operating characteristic curve, wideband absorbance in ambient and tympanometric tests were significantly better predictors of CHL than tympanometric width, the best 0.226-kHz predictor. Accuracies of ambient and tympanometric wideband absorbance did not differ. CONCLUSIONS: Absorbance accurately predicted CHL in children and was more accurate than conventional 0.226-kHz tympanometry.


Subject(s)
Ear Canal/physiopathology , Hearing Loss, Conductive/diagnosis , Hearing Tests/methods , Hearing , Otitis Media with Effusion/complications , Acoustic Impedance Tests , Acoustic Stimulation , Audiometry , Auditory Threshold , Bone Conduction , Case-Control Studies , Child , Child, Preschool , Hearing Loss, Conductive/etiology , Hearing Loss, Conductive/physiopathology , Humans , Multivariate Analysis , Otitis Media with Effusion/diagnosis , Otitis Media with Effusion/physiopathology , Predictive Value of Tests , Pressure , ROC Curve , Risk Factors
13.
J Acoust Soc Am ; 129(1): 245-61, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21303007

ABSTRACT

In contrast to clinical click-evoked otoacoustic emission (CEOAE) tests that are inaccurate above 4-5 kHz, a research procedure measured CEOAEs up to 16 kHz in 446 ears and predicted the presence/absence of a sensorineural hearing loss. The behavioral threshold test that served as a reference to evaluate CEOAE test accuracy used a yes-no task in a maximum-likelihood adaptive procedure. This test was highly efficient between 0.5 and 12.7 kHz: Thresholds measured in 2 min per frequency had a median standard deviation (SD) of 1.2-1.5 dB across subjects. CEOAE test performance was assessed by the area under the receiver operating characteristic curve (AUC). The mean AUC from 1 to 10 kHz was 0.90 (SD=0.016). AUC decreased to 0.86 at 12.7 kHz and to 0.7 at 0.5 and 16 kHz, possibly due in part to insufficient stimulus levels. Between 1 and 12.7 kHz, the medians of the magnitude difference in CEOAEs and in behavioral thresholds were <4 dB. The improved CEOAE test performance above 4-5 kHz was due to retaining the portion of the CEOAE response with latencies as short as 0.3 ms. Results have potential clinical significance in predicting hearing status from at least 1 to 10 kHz using a single CEOAE response.


Subject(s)
Audiometry/methods , Cochlea/physiopathology , Hearing Loss, Sensorineural/diagnosis , Otoacoustic Emissions, Spontaneous , Acoustic Stimulation , Adolescent , Adult , Aged , Audiometry, Pure-Tone , Auditory Threshold , Case-Control Studies , Female , Hearing Loss, Sensorineural/physiopathology , Hearing Loss, Sensorineural/psychology , Humans , Male , Middle Aged , Predictive Value of Tests , Psychoacoustics , Reaction Time , Reproducibility of Results , Sound Spectrography , Time Factors , Young Adult
14.
J Acoust Soc Am ; 125(2): 1014-32, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19206876

ABSTRACT

Relationships between click-evoked otoacoustic emissions (CEOAEs) and behavioral thresholds have not been explored above 5 kHz due to limitations in CEOAE measurement procedures. New techniques were used to measure behavioral thresholds and CEOAEs up to 16 kHz. A long cylindrical tube of 8 mm diameter, serving as a reflectionless termination, was used to calibrate audiometric stimuli and design a wideband CEOAE stimulus. A second click was presented 15 dB above a probe click level that varied over a 44 dB range, and a nonlinear residual procedure extracted a CEOAE from these click responses. In some subjects (age 14-29 years) with normal hearing up to 8 kHz, CEOAE spectral energy and latency were measured up to 16 kHz. Audiometric thresholds were measured using an adaptive yes-no procedure. Comparison of CEOAE and behavioral thresholds suggested a clinical potential of using CEOAEs to screen for high-frequency hearing loss. CEOAE latencies determined from the peak of averaged, filtered temporal envelopes decreased to 1 ms with increasing frequency up to 16 kHz. Individual CEOAE envelopes included both compressively growing longer-delay components consistent with a coherent-reflection source and linearly or expansively growing shorter-delay components consistent with a distortion source. Envelope delays of both components were approximately invariant with level.


Subject(s)
Auditory Threshold , Otoacoustic Emissions, Spontaneous , Acoustic Stimulation , Adolescent , Adult , Audiometry/standards , Calibration , Female , Humans , Male , Models, Biological , Nonlinear Dynamics , Reaction Time , Sound Spectrography , Time Factors , Young Adult
15.
J Acoust Soc Am ; 125(3): 1595-604, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19275317

ABSTRACT

Behavioral threshold for a tone burst presented in a long-duration noise masker decreases as the onset of the tone burst is delayed relative to masker onset. The threshold difference between detection of early- and late-onset tone bursts is called overshoot. Although the underlying mechanisms are unclear, one hypothesis is that overshoot occurs due to efferent suppression of cochlear nonlinearity [von Klitzing, R., and Kohlrausch, A. (1994). J. Acoust. Soc. Am. 95, 2192-2201]. This hypothesis was tested by using overshoot conditions to elicit stimulus-frequency otoacoustic emissions (SFOAEs), which provide a physiological measure of cochlear nonlinearity. SFOAE and behavioral thresholds were estimated using a modified maximum-likelihood yes-no procedure. The masker was a 400-ms "frozen" notched noise. The signal was a 20-ms, 4-kHz tone burst presented at 1 or 200 ms after the noise onset. Behavioral overshoot results replicated previous studies, but no overshoot was observed in SFOAE thresholds. This suggests that either efferent suppression of cochlear nonlinearity is not involved in overshoot, or a SFOAE threshold estimation procedure based on stimuli similar to those used to study behavioral overshoot is not sensitive enough to measure the effect.


Subject(s)
Cochlea/physiology , Otoacoustic Emissions, Spontaneous/physiology , Auditory Threshold/physiology , Female , Hair Cells, Auditory, Outer/physiology , Humans , Male , Time Factors , Young Adult
16.
Hear Res ; 371: 117-139, 2019 01.
Article in English | MEDLINE | ID: mdl-30409510

ABSTRACT

Transient-evoked otoacoustic emissions (TEOAEs) at high frequencies are a non-invasive physiological test of basilar membrane mechanics at the basal end, and have clinical potential to detect risk of hearing loss related to outer-hair-cell dysfunction. Using stimuli with constant incident pressure across frequency, TEOAEs were measured in experiment 1 at low frequencies (0.7-8 kHz) and high frequencies (7.1-14.7 kHz) in adults with normal hearing up to 8 kHz and varying hearing levels from 9 to 16 kHz. In combination with click stimuli, chirp stimuli were used with slow, medium and fast sweep rates for which the local frequency increased or decreased with time. Chirp TEOAEs were transformed into equivalent click TEOAEs by inverse filtering out chirp stimulus phase, and analyzed similarly to click TEOAEs. To improve detection above 8 kHz, TEOAEs were measured in experiment 2 with higher-level stimuli and longer averaging times. These changes increased the TEOAE signal-to-noise ratio (SNR) by 10 dB. Slower sweep rates were investigated but the elicited TEOAEs were detected in fewer ears compared to faster rates. Data were acquired in adults and children (age 11-17 y), including children with cystic fibrosis (CF) treated with ototoxic antibiotics. Test-retest measurements revealed satisfactory repeatability of high-frequency TEOAE SNR (median of 1.3 dB) and coherence synchrony measure, despite small test-retest differences related to changes in forward and reverse transmission in the ear canal. The results suggest the potential use of such tests to screen for sensorineural hearing loss, including ototoxic loss. Experiment 2 was a feasibility study to explore TEOAE test parameters that might be used in a full-scale study to screen CF patients for risk of ototoxic hearing loss.


Subject(s)
Acoustic Stimulation/methods , Audiometry/methods , Otoacoustic Emissions, Spontaneous/physiology , Adolescent , Adult , Auditory Threshold/physiology , Child , Cystic Fibrosis/complications , Cystic Fibrosis/drug therapy , Feasibility Studies , Female , Hair Cells, Auditory, Outer/physiology , Hearing Loss, Sensorineural/diagnosis , Hearing Loss, Sensorineural/etiology , Hearing Loss, Sensorineural/physiopathology , Humans , Male , Middle Aged , Ototoxicity/diagnosis , Ototoxicity/etiology , Ototoxicity/physiopathology , Young Adult
17.
J Acoust Soc Am ; 123(3): 1479-94, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18345837

ABSTRACT

Stimulus frequency otoacoustic emissions (SFOAEs) measured using a suppressor tone in human ears are analogous to two-tone suppression responses measured mechanically and neurally in mammalian cochleae. SFOAE suppression was measured in 24 normal-hearing adults at octave frequencies (f(p)=0.5-8.0 kHz) over a 40 dB range of probe levels (L(p)). Suppressor frequencies (f(s)) ranged from -2.0 to 0.7 octaves re: f(p), and suppressor levels ranged from just detectable suppression to full suppression. The lowest suppression thresholds occurred for "best" f(s) slightly higher than f(p). SFOAE growth of suppression (GOS) had slopes close to one at frequencies much lower than best f(s), and shallow slopes near best f(s), which indicated compressive growth close to 0.3 dBdB. Suppression tuning curves constructed from GOS functions were well defined at 1, 2, and 4 kHz, but less so at 0.5 and 8.0 kHz. Tuning was sharper at lower L(p) with an equivalent rectangular bandwidth similar to that reported behaviorally for simultaneous masking. The tip-to-tail difference assessed cochlear gain, increasing with decreasing L(p) and increasing f(p) at the lowest L(p) from 32 to 45 dB for f(p) from 1 to 4 kHz. SFOAE suppression provides a noninvasive measure of the saturating nonlinearities associated with cochlear amplification on the basilar membrane.


Subject(s)
Cochlea/physiology , Otoacoustic Emissions, Spontaneous/physiology , Perceptual Masking/physiology , Adult , Auditory Threshold/physiology , Humans
18.
J Acoust Soc Am ; 124(6): 3708-19, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19206798

ABSTRACT

A system with potential for middle-ear screening and diagnostic testing was developed for the measurement of wideband energy absorbance (EA) in the ear canal as a function of air pressure, and tested on adults with normal hearing. Using a click stimulus, the EA was measured at 60 frequencies between 0.226 and 8 kHz. Ambient-pressure results were similar to past studies. To perform tympanometry, air pressure in the ear canal was controlled automatically to sweep between -300 and 200 daPa (ascending/descending directions) using sweep speeds of approximately 75, 100, 200, and 400 daPas. Thus, the measurement time for wideband tympanometry ranged from 1.5 to 7 s and was suitable for clinical applications. A bandpass tympanogram, calculated for each ear by frequency averaging EA from 0.38 to 2 kHz, had a single-peak shape; however, its tympanometric peak pressure (TPP) shifted as a function of sweep speed and direction. EA estimated at the TPP was similar across different sweep speeds, but was higher below 2 kHz than EA measured at ambient pressure. Future studies of EA on normal ears of a different age group or on impaired ears may be compared with the adult normal baseline obtained in this study.


Subject(s)
Acoustic Impedance Tests/methods , Acoustic Stimulation , Ear Canal/physiology , Ear, Middle/physiology , Hearing , Acoustic Impedance Tests/standards , Adult , Air Pressure , Artifacts , Calibration , Feasibility Studies , Humans , Reference Values , Reproducibility of Results , Signal Processing, Computer-Assisted , Time Factors , Young Adult
19.
J Assoc Res Otolaryngol ; 18(1): 65-88, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27957612

ABSTRACT

Power-based procedures are described to measure acoustic stapedius-muscle reflex threshold and supra-threshold responses in human adult and infant ears at frequencies from 0.2 to 8 kHz. The stimulus set included five clicks in which four pulsed activators were placed between each pair of clicks, with each stimulus set separated from the next by 0.79 s to allow for reflex decay. Each click response was used to detect the presence of reflex effects across frequency that were elicited by a pulsed broadband-noise or tonal activator in the ipsilateral or contralateral test ear. Acoustic reflex shifts were quantified in terms of the difference in absorbed sound power between the initial baseline click and the later four clicks in each set. Acoustic reflex shifts were measured over a 40-dB range of pulsed activators, and the acoustic reflex threshold was objectively calculated using a maximum 10 likelihood procedure. To illustrate the principles underlying these new reflex tests, reflex shifts in absorbed sound power and absorbance are presented for data acquired in an adult ear with normal hearing and in two infant ears in the initial and follow-up newborn hearing screening exams, one with normal hearing and the other with a conductive hearing loss. The use of absorbed sound power was helpful in classifying an acoustic reflex shift as present or absent. The resulting reflex tests are in use in a large study of wideband clinical diagnosis and monitoring of middle-ear and cochlear function in infant and adult ears.


Subject(s)
Auditory Threshold , Reflex, Acoustic/physiology , Acoustic Stimulation , Adult , Hearing , Hearing Loss, Conductive/physiopathology , Humans , Infant , Infant, Newborn
20.
J Assoc Res Otolaryngol ; 18(1): 49-63, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27928634

ABSTRACT

This study analyzed effects of pressurization on wideband acoustic stapedial-muscle reflex (ASR) tests in infants cared for in normal newborn (NN) and neonatal intensive care units (NICU). Effects of hearing-screening outcomes on ASR threshold measurements were also evaluated, and a subsequent longitudinal study established normative threshold ranges over the first year after birth. An initial experiment compared thresholds in newborns measured at ambient pressure in the ear canal and at the tympanometric peak pressure. ASR thresholds for broadband noise were higher for ears that did not pass newborn hearing screening and ASR threshold was 14 dB higher for real-ear compared to coupler conditions. Effects of pressurization were significant for ears that passed screening; thus, ASR testing in infants should be conducted at tympanometric peak pressure. ASR threshold was significantly higher for ears that referred on transient evoked otoacoustic emissions and Auditory Brainstem Response (ABR) screening tests and also for ears with conductive and sensorineural hearing loss diagnosed by ABR. Developmental ASR changes were significant over the first year for both normal and NICU infants. Wideband pressurized ASR thresholds are a clinically relevant measure of newborn hearing screening and diagnostic outcomes.


Subject(s)
Auditory Threshold , Hearing , Reflex, Acoustic/physiology , Acoustic Impedance Tests , Evoked Potentials, Auditory, Brain Stem , Female , Humans , Infant , Infant, Newborn , Male , Neonatal Screening
SELECTION OF CITATIONS
SEARCH DETAIL