Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Am Heart J ; 271: 68-75, 2024 05.
Article in English | MEDLINE | ID: mdl-38401649

ABSTRACT

BACKGROUND: Both transcatheter edge-to-edge repair (TEER) of mitral regurgitation or left atrial appendage closure (LAAC) require periprocedural anticoagulation with unfractionated heparin (UFH) that is administered either before or immediately after transseptal puncture (TSP). The optimal timing of UFH administration (before or after TSP) is unknown. The Strategy To Optimize PeriproCeduraL AnticOagulation in Structural Transseptal Interventions trial (STOP CLOT Trial) was designed to determine if early anticoagulation is effective in reducing ischemic complications without increasing the risk of periprocedural bleeding. METHODS: The STOP CLOT trial is a multicenter, prospective, double-blind, placebo-controlled, randomized trial. A total of 410 patients scheduled for TEER or LAAC will be randomized 1:1 either early UFH administration (iv. bolus of 100 units/kg UFH or placebo, given after obtaining femoral vein access and at least 5 minutes prior to the start of the TSP) or late UFH administration (iv. bolus of 100 units/kg UFH or placebo given immediately after TSP). Prespecified preliminary statistical analysis will be performed after complete follow-up of the first 196 randomized subjects. To ensure blinding, a study nurse responsible for randomization and UFH/placebo preparation is not involved in the care of the patients enrolled into the study. The primary study endpoint is a composite of (1) major adverse cardiac and cerebrovascular events (death, stroke, TIA, myocardial infarction, or peripheral embolization) within 30 days post-procedure, (2) intraprocedural fresh thrombus formation in the right or left atrium as assessed with periprocedural transesophageal echocardiography, or (3) occurrence of new ischemic lesions (diameter ≥4 mm) on brain magnetic resonance imaging performed 2 to 5 days after the procedure. The safety endpoint is the occurrence of moderate or severe bleeding complications during the index hospitalization. CONCLUSIONS: Protocols of periprocedural anticoagulation administration during structural interventions have never been tested in a randomized clinical trial. The Stop Clot trial may help reach consensus on the optimal timing of initiation of periprocedural anticoagulation. CLINICAL TRIALS REGISTRATION NUMBER: The study protocol is registered at ClinicalTrials.gov, identifier NCT05305612.


Subject(s)
Anticoagulants , Atrial Appendage , Cardiac Catheterization , Heparin , Mitral Valve Insufficiency , Female , Humans , Male , Anticoagulants/administration & dosage , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Cardiac Catheterization/methods , Double-Blind Method , Heart Septum/surgery , Heparin/administration & dosage , Mitral Valve Insufficiency/surgery , Prospective Studies , Multicenter Studies as Topic , Randomized Controlled Trials as Topic
2.
JACC Cardiovasc Interv ; 17(5): 648-661, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38385922

ABSTRACT

BACKGROUND: Early studies of the Tendyne transcatheter mitral valve replacement (TMVR) showed promising results in a small selective cohort. OBJECTIVES: The authors present 1-year data from the currently largest commercial, real-world cohort originating from the investigator-initiated TENDER (Tendyne European Experience) registry. METHODS: All patients from the TENDER registry eligible for 1-year follow-up were included. The primary safety endpoint was 1-year cardiovascular mortality. Primary performance endpoint was reduction of mitral regurgitation (MR) up to 1 year. RESULTS: Among 195 eligible patients undergoing TMVR (median age 77 years [Q1-Q3: 71-81 years], 60% men, median Society of Thoracic Surgeons Predicted Risk of Mortality 5.6% [Q1-Q3: 3.6%-8.9%], 81% in NYHA functional class III or IV, 94% with MR 3+/4+), 31% had "real-world" indications for TMVR (severe mitral annular calcification, prior mitral valve treatment, or others) outside of the instructions for use. The technical success rate was 95%. The cardiovascular mortality rate was 7% at 30 day and 17% at 1 year (all-cause mortality rates were 9% and 29%, respectively). Reintervention or surgery following discharge was 4%, while rates of heart failure hospitalization reduced from 68% in the preceding year to 25% during 1-year follow-up. Durable MR reduction to ≤1+ was achieved in 98% of patients, and at 1 year, 83% were in NYHA functional class I or II. There was no difference in survival and major adverse events between on-label use and "real-world" indications up to 1 year. CONCLUSIONS: This large, real-world, observational registry reports high technical success, durable and complete MR elimination, significant clinical benefits, and a 1-year cardiovascular mortality rate of 17% after Tendyne TMVR. Outcomes were comparable between on-label use and "real-world" indications, offering a safe and efficacious treatment option for patients without alternative treatments. (Tendyne European Experience Registry [TENDER]; NCT04898335).


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Male , Humans , Aged , Female , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis/adverse effects , Treatment Outcome , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Cardiac Catheterization/methods , Registries
3.
Am J Cardiol ; 219: 60-70, 2024 05 15.
Article in English | MEDLINE | ID: mdl-38401656

ABSTRACT

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Male , Female , Aortic Valve Stenosis/surgery , Sex Factors , Aged, 80 and over , Aged , Treatment Outcome , Postoperative Complications/epidemiology , Aortic Valve/surgery
SELECTION OF CITATIONS
SEARCH DETAIL