Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 136
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Heart Fail Rev ; 29(2): 379-394, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37728751

ABSTRACT

Heart failure (HF) and chronic kidney disease (CKD) are two pathological conditions with a high prevalence in the general population. When they coexist in the same patient, a strict interplay between them is observed, such that patients affected require a clinical multidisciplinary and personalized management. The diagnosis of HF and CKD relies on signs and symptoms of the patient but several additional tools, such as blood-based biomarkers and imaging techniques, are needed to clarify and discriminate the main characteristics of these diseases. Improved survival due to new recommended drugs in HF has increasingly challenged physicians to manage patients with multiple diseases, especially in case of CKD. However, the safe administration of these drugs in patients with HF and CKD is often challenging. Knowing up to which values ​​of creatinine or renal clearance each drug can be administered is fundamental. With this review we sought to give an insight on this sizable and complex topic, in order to get clearer ideas and a more precise reference about the diagnostic assessment and therapeutic management of HF and CKD.


Subject(s)
Heart Failure , Renal Insufficiency, Chronic , Humans , Heart Failure/therapy , Heart Failure/drug therapy , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/epidemiology , Biomarkers
2.
Eur Radiol ; 34(4): 2665-2676, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37750979

ABSTRACT

OBJECTIVES: No clear recommendations are endorsed by the different scientific societies on the clinical use of repeat coronary computed tomography angiography (CCTA) in patients with non-obstructive coronary artery disease (CAD). This study aimed to develop and validate a practical CCTA risk score to predict medium-term disease progression in patients at a low-to-intermediate probability of CAD. METHODS: Patients were part of the Progression of AtheRosclerotic PlAque Determined by Computed Tomographic Angiography Imaging (PARADIGM) registry. Specifically, 370 (derivation cohort) and 219 (validation cohort) patients with two repeat, clinically indicated CCTA scans, non-obstructive CAD, and absence of high-risk plaque (≥ 2 high-risk features) at baseline CCTA were included. Disease progression was defined as the new occurrence of ≥ 50% stenosis and/or high-risk plaque at follow-up CCTA. RESULTS: In the derivation cohort, 104 (28%) patients experienced disease progression. The median time interval between the two CCTAs was 3.3 years (2.7-4.8). Odds ratios for disease progression derived from multivariable logistic regression were as follows: 4.59 (95% confidence interval: 1.69-12.48) for the number of plaques with spotty calcification, 3.73 (1.46-9.52) for the number of plaques with low attenuation component, 2.71 (1.62-4.50) for 25-49% stenosis severity, 1.47 (1.17-1.84) for the number of bifurcation plaques, and 1.21 (1.02-1.42) for the time between the two CCTAs. The C-statistics of the model were 0.732 (0.676-0.788) and 0.668 (0.583-0.752) in the derivation and validation cohorts, respectively. CONCLUSIONS: The new CCTA-based risk score is a simple and practical tool that can predict mid-term CAD progression in patients with known non-obstructive CAD. CLINICAL RELEVANCE STATEMENT: The clinical implementation of this new CCTA-based risk score can help promote the management of patients with non-obstructive coronary disease in terms of timing of imaging follow-up and therapeutic strategies. KEY POINTS: • No recommendations are available on the use of repeat CCTA in patients with non-obstructive CAD. • This new CCTA score predicts mid-term CAD progression in patients with non-obstructive stenosis at baseline. • This new CCTA score can help guide the clinical management of patients with non-obstructive CAD.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Plaque, Atherosclerotic , Humans , Plaque, Atherosclerotic/diagnostic imaging , Computed Tomography Angiography/methods , Coronary Angiography/methods , Constriction, Pathologic , Risk Assessment/methods , Predictive Value of Tests , Coronary Artery Disease/diagnostic imaging , Risk Factors , Disease Progression , Registries
3.
Echocardiography ; 41(1): e15724, 2024 01.
Article in English | MEDLINE | ID: mdl-38064288

ABSTRACT

BACKGROUND AND AIM: Our aim was to evaluate the fluoroscopy time (FT), procedure time (PT) safety and efficacy when using intracardiac echocardiography (ICE) in comparison to transesophageal echocardiography (TEE) guidance for transcatheter closure of Ostium Secundum Atrial Septal Defect (OS-ASD). METHOD: Ninety patients (n = 90) diagnosed with OS-ASD underwent transcatheter closure between March 2006 and October 2021. Fifty-seven patients were treated under ICE guidance, while 33 patients were treated under TEE guidance. RESULTS: Mean age was 43 ± 15 years and 42 ± 10 years in the ICE and TEE groups, respectively. The majority of patients had a centrally placed defect. Median FT was 8.40 min versus 11.70 min (p < .001) in the ICE group compared to the TEE group, respectively. Median PT was 43 min versus 94 min (p < .001) in the ICE group compared to the TEE group, respectively. Both ICE and TEE provided high quality images. All interventions were completed successfully, except for one patient in the ICE group who experienced a device migration, the development of atrial tachycardia in one patient and atrial fibrillation in two patients in the ICE group which spontaneously cardioverted. There were no other complications. CONCLUSION: This study on a consistent cohort of patients with OS-ASD undergoing percutaneous closure suggests that use of ICE is safe and efficacious. Compared to TEE, ICE demonstrated significantly shorter FT and PT, decreasing the entire duration of the procedure and x-ray exposure. No relevant differences were observed in terms of success rate and complications.


Subject(s)
Atrial Fibrillation , Heart Septal Defects, Atrial , Humans , Adult , Middle Aged , Echocardiography, Transesophageal/methods , Cardiac Catheterization/methods , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Fluoroscopy , Treatment Outcome
4.
Radiology ; 307(3): e222239, 2023 05.
Article in English | MEDLINE | ID: mdl-36943075

ABSTRACT

Background Scar burden with late gadolinium enhancement (LGE) cardiac MRI (CMR) predicts arrhythmic events in patients with postinfarction in single-center studies. However, LGE analysis requires experienced human observers, is time consuming, and introduces variability. Purpose To test whether postinfarct scar with LGE CMR can be quantified fully automatically by machines and to compare the ability of LGE CMR scar analyzed by humans and machines to predict arrhythmic events. Materials and Methods This study is a retrospective analysis of the multicenter, multivendor CarDiac MagnEtic Resonance for Primary Prevention Implantable CardioVerter DebrillAtor ThErapy (DERIVATE) registry. Patients with chronic heart failure, echocardiographic left ventricular ejection fraction (LVEF) of less than 50%, and LGE CMR were recruited (from January 2015 through December 2020). In the current study, only patients with ischemic cardiomyopathy were included. Quantification of total, dense, and nondense scars was carried out by two experienced readers or a Ternaus network, trained and tested with LGE images of 515 and 246 patients, respectively. Univariable and multivariable Cox analyses were used to assess patient and cardiac characteristics associated with a major adverse cardiac event (MACE). Area under the receiver operating characteristic curve (AUC) was used to compare model performances. Results In 761 patients (mean age, 65 years ± 11, 671 men), 83 MACEs occurred. With use of the testing group, univariable Cox-analysis found New York Heart Association class, left ventricle volume and/or function parameters (by echocardiography or CMR), guideline criterion (LVEF of ≤35% and New York Heart Association class II or III), and LGE scar analyzed by humans or the machine-learning algorithm as predictors of MACE. Machine-based dense or total scar conferred incremental value over the guideline criterion for the association with MACE (AUC: 0.68 vs 0.63, P = .02 and AUC: 0.67 vs 0.63, P = .01, respectively). Modeling with competing risks yielded for dense and total scar (AUC: 0.67 vs 0.61, P = .01 and AUC: 0.66 vs 0.61, P = .005, respectively). Conclusion In this analysis of the multicenter CarDiac MagnEtic Resonance for Primary Prevention Implantable CardioVerter DebrillAtor ThErapy (DERIVATE) registry, fully automatic machine learning-based late gadolinium enhancement analysis reliably quantifies myocardial scar mass and improves the current prediction model that uses guideline-based risk criteria for implantable cardioverter defibrillator implantation. ClinicalTrials.gov registration no.: NCT03352648 Published under a CC BY 4.0 license. Supplemental material is available for this article.


Subject(s)
Cicatrix , Contrast Media , Male , Humans , Aged , Stroke Volume , Retrospective Studies , Magnetic Resonance Imaging, Cine/methods , Gadolinium , Ventricular Function, Left , Magnetic Resonance Imaging/methods , Registries , Artificial Intelligence , Predictive Value of Tests
5.
Eur Heart J Suppl ; 25(Suppl C): C49-C57, 2023 May.
Article in English | MEDLINE | ID: mdl-37125321

ABSTRACT

Ischaemic heart disease (IHD) is one of the world's leading causes of morbidity and mortality. Likewise, the diagnosis and risk stratification of patients with coronary artery disease (CAD) have always been based on the detection of the presence and extent of ischaemia by physical or pharmacological stress tests with or without the aid of imaging methods (e.g. exercise stress, test, stress echocardiography, single-photon emission computed tomography, or stress cardiac magnetic resonance). These methods show high performance to assess obstructive CAD, whilst they do not show accurate power to detect non-obstructive CAD. The introduction into clinical practice of coronary computed tomography angiography, the only non-invasive method capable of analyzing the coronary anatomy, allowed to add a crucial piece in the puzzle of the assessment of patients with suspected or chronic IHD. The current review evaluates the technical aspects and clinical experience of coronary computed tomography in the evaluation of atherosclerotic burden with a special focus about the new emerging application such as functional relevance of CAD with fractional flow reserve computed tomography (CT)-derived (FFRct), stress CT perfusion, and imaging inflammatory makers discussing the strength and weakness of each approach.

6.
Eur J Nucl Med Mol Imaging ; 49(6): 1894-1905, 2022 05.
Article in English | MEDLINE | ID: mdl-34984502

ABSTRACT

PURPOSE: Quantification of myocardial blood flow (MBF) and functional assessment of coronary artery disease (CAD) can be achieved through stress myocardial computed tomography perfusion (stress-CTP). This requires an additional scan after the resting coronary computed tomography angiography (cCTA) and administration of an intravenous stressor. This complex protocol has limited reproducibility and non-negligible side effects for the patient. We aim to mitigate these drawbacks by proposing a computational model able to reproduce MBF maps. METHODS: A computational perfusion model was used to reproduce MBF maps. The model parameters were estimated by using information from cCTA and MBF measured from stress-CTP (MBFCTP) maps. The relative error between the computational MBF under stress conditions (MBFCOMP) and MBFCTP was evaluated to assess the accuracy of the proposed computational model. RESULTS: Applying our method to 9 patients (4 control subjects without ischemia vs 5 patients with myocardial ischemia), we found an excellent agreement between the values of MBFCOMP and MBFCTP. In all patients, the relative error was below 8% over all the myocardium, with an average-in-space value below 4%. CONCLUSION: The results of this pilot work demonstrate the accuracy and reliability of the proposed computational model in reproducing MBF under stress conditions. This consistency test is a preliminary step in the framework of a more ambitious project which is currently under investigation, i.e., the construction of a computational tool able to predict MBF avoiding the stress protocol and potential side effects while reducing radiation exposure.


Subject(s)
Coronary Artery Disease , Myocardial Perfusion Imaging , Humans , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Circulation , Myocardial Perfusion Imaging/methods , Predictive Value of Tests , Reproducibility of Results
7.
Eur J Nucl Med Mol Imaging ; 49(9): 3119-3128, 2022 07.
Article in English | MEDLINE | ID: mdl-35194673

ABSTRACT

PURPOSE: To evaluate the diagnostic accuracy of a deep learning (DL) algorithm predicting hemodynamically significant coronary artery disease (CAD) by using a rest dataset of myocardial computed tomography perfusion (CTP) as compared to invasive evaluation. METHODS: One hundred and twelve consecutive symptomatic patients scheduled for clinically indicated invasive coronary angiography (ICA) underwent CCTA plus static stress CTP and ICA with invasive fractional flow reserve (FFR) for stenoses ranging between 30 and 80%. Subsequently, a DL algorithm for the prediction of significant CAD by using the rest dataset (CTP-DLrest) and stress dataset (CTP-DLstress) was developed. The diagnostic accuracy for identification of significant CAD using CCTA, CCTA + CTP stress, CCTA + CTP-DLrest, and CCTA + CTP-DLstress was measured and compared. The time of analysis for CTP stress, CTP-DLrest, and CTP-DLStress was recorded. RESULTS: Patient-specific sensitivity, specificity, NPV, PPV, accuracy, and area under the curve (AUC) of CCTA alone and CCTA + CTPStress were 100%, 33%, 100%, 54%, 63%, 67% and 86%, 89%, 89%, 86%, 88%, 87%, respectively. Patient-specific sensitivity, specificity, NPV, PPV, accuracy, and AUC of CCTA + DLrest and CCTA + DLstress were 100%, 72%, 100%, 74%, 84%, 96% and 93%, 83%, 94%, 81%, 88%, 98%, respectively. All CCTA + CTP stress, CCTA + CTP-DLRest, and CCTA + CTP-DLStress significantly improved detection of hemodynamically significant CAD compared to CCTA alone (p < 0.01). Time of CTP-DL was significantly lower as compared to human analysis (39.2 ± 3.2 vs. 379.6 ± 68.0 s, p < 0.001). CONCLUSION: Evaluation of myocardial ischemia using a DL approach on rest CTP datasets is feasible and accurate. This approach may be a useful gatekeeper prior to CTP stress..


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Deep Learning , Fractional Flow Reserve, Myocardial , Myocardial Perfusion Imaging , Humans , Computed Tomography Angiography , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Myocardial Perfusion Imaging/methods , Perfusion , Predictive Value of Tests
8.
Eur Radiol ; 32(9): 6017-6027, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35364711

ABSTRACT

OBJECTIVES: Computed tomography (CT) provides excellent anatomy assessment of the aortic annulus (AoA) and is utilized for pre-procedural planning of transcatheter aortic valve implantation (TAVI). We sought to investigate if geometrical characteristics of the AoA determined by CT may represent predictors of structural valve degeneration (SVD) in patients undergoing TAVI with balloon-expandable valves. METHODS: This is a retrospective study on 124 consecutive patients (mean age: 79 ± 7 years; female: 61%) undergoing balloon-expandable TAVI prospectively enrolled in a registry. AoA maximum diameter (Dmax), minimum diameter (Dmin), and area were assessed using pre-procedural CT. SVD was identified during follow-up with transthoracic echocardiography documenting structural prosthetic valve abnormalities with or without hemodynamic changes. RESULTS: The mean follow-up was 5.9 ± 1.7 years. SVD was found in 48 out of 124 patients (38%). AoA Dmax, Dmin, and area were significantly smaller in patients with SVD compared to patients without SVD (25.6 ± 2.2 mm vs. 27.1 ± 2.8 mm, p = 0.012; 20.5 ± 2.1 mm vs. 21.8 ± 2.1 mm, p = 0.001 and 419 ± 77 mm2 vs. 467 ± 88 mm2, p = 0.002, respectively). At univariable analysis, female sex, BSA, 23-mm prosthetic valve size, Dmax < 27.1 mm, and a Dmin < 19.9 mm were associated with SVD, whereas at multivariable analysis, only Dmin < 19.9 mm (OR = 2.873, 95% CI: 1.191-6.929, p = 0.019) and female sex (OR = 2.659, 95% CI: 1.095-6.458, p = 0.031) were independent predictors of SVD. CONCLUSIONS: Female sex and AoA Dmin < 19.9 mm are associated with SVD in patients undergoing TAVI with balloon-expandable valves. When implanting large prostheses in order to avoid paraprosthetic regurgitation, caution should be observed due to the risk of excessive stretching of the AoA Dmin, which may play a role in SVD. KEY POINTS: • Long-term durability is a concern for transcatheter aortic valve bioprosthesis. • CT provides an excellent assessment of the aortic annulus's geometrical characteristics for prosthesis sizing before transcatheter aortic valve implantation (TAVI). • Female sex and a small minimum aortic annulus diameter measured with CT are independent predictors of structural valve degeneration in patients undergoing TAVI with balloon-expandable valves.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Heart Valve Prosthesis Implantation/methods , Humans , Prosthesis Design , Retrospective Studies , Tomography, X-Ray Computed , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
9.
Eur Radiol ; 31(2): 1100-1109, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32803414

ABSTRACT

OBJECTIVES: T1 mapping (T1-map) and cardiac magnetic resonance feature tracking (CMR-FT) techniques have been introduced for the early detection of interstitial myocardial fibrosis and deformation abnormalities. We sought to demonstrate that T1-map and CMR-FT may identify the presence of subclinical myocardial structural changes in patients with mitral valve prolapse (MVP). METHODS: Consecutive MVP patients with moderate-to-severe mitral regurgitation and comparative matched healthy subjects were prospectively enrolled and underwent CMR-FT analysis to calculate 2D global and segmental circumferential (CS) and radial strain (RS) and T1-map to determine global and segmental native T1 (nT1) values. RESULTS: Seventy-three MVP patients (mean age, 57 ± 13 years old; male, 76%; regurgitant volume, 57 ± 21 mL) and 42 matched control subjects (mean age, 56 ± 18 years; male, 74%) were included. MVP patients showed a lower global CS (- 16.3 ± 3.4% vs. - 17.8 ± 1.9%, p = 0.020) and longer global nT1 (1124.9 ± 97.7 ms vs. 1007.4 ± 26.1 ms, p < 0.001) as compared to controls. Moreover, MVP patients showed lower RS and CS in basal (21.6 ± 12.3% vs. 27.6 ± 8.9%, p = 0.008, and - 13.0 ± 6.7% vs. - 14.9 ± 4.1%, p = 0.013) and mid-inferolateral (20.6 ± 10.7% vs. 28.4 ± 8.7%, p < 0.001, and - 12.8 ± 6.3% vs. - 16.5 ± 4.0%, p < 0.001) walls as compared to other myocardial segments. Similarly, MVP patients showed longer nT1 values in basal (1080 ± 68 ms vs. 1043 ± 43 ms, p < 0.001) and mid-inferolateral (1080 ± 77 ms vs. 1034 ± 37 ms, p < 0.001) walls as compared to other myocardial segments. Of note, nT1 values were significantly correlated with CS (r, 0.36; p < 0.001) and RS (r, 0.37; p < 0.001) but not with regurgitant volume. CONCLUSIONS: T1-map and CMR-FT identify subclinical left ventricle tissue changes in patients with MVP. Further studies are required to correlate these subclinical tissue changes with the outcome. KEY POINTS: • T1 mapping (T1-map) and cardiac magnetic resonance feature tracking (CMR-FT) techniques have been introduced for the early detection of interstitial myocardial fibrosis and deformation abnormalities. • In MVP patients, we demonstrated a longer global nT1 with associated reduced global circumferential (CS) and radial strain (RS) as compared to control subjects. • Among MVP patients, the mid-basal left ventricle inferolateral wall showed longer nT1 with reduced CS and RS as compared to other myocardial segments. Further studies are required to correlate these subclinical tissue changes with the outcome.


Subject(s)
Mitral Valve Prolapse , Adult , Aged , Heart , Humans , Magnetic Resonance Imaging, Cine , Magnetic Resonance Spectroscopy , Male , Middle Aged , Mitral Valve Prolapse/diagnostic imaging , Myocardium , Predictive Value of Tests
10.
Europace ; 23(7): 1072-1083, 2021 07 18.
Article in English | MEDLINE | ID: mdl-33792661

ABSTRACT

AIMS: The aim of this registry was to evaluate the additional prognostic value of a composite cardiac magnetic resonance (CMR)-based risk score over standard-of-care (SOC) evaluation in a large cohort of consecutive unselected non-ischaemic cardiomyopathy (NICM) patients. METHODS AND RESULTS: In the DERIVATE registry (www.clinicaltrials.gov/registration: RCT#NCT03352648), 1000 (derivation cohort) and 508 (validation cohort) NICM patients with chronic heart failure (HF) and left ventricular ejection fraction <50% were included. All-cause mortality and major adverse arrhythmic cardiac events (MAACE) were the primary and secondary endpoints, respectively. During a median follow-up of 959 days, all-cause mortality and MAACE occurred in 72 (7%) and 93 (9%) patients, respectively. Age and >3 segments with midwall fibrosis on late gadolinium enhancement (LGE) were the only independent predictors of all-cause mortality (HR: 1.036, 95% CI: 1.0117-1.056, P < 0.001 and HR: 2.077, 95% CI: 1.211-3.562, P = 0.008, respectively). For MAACE, the independent predictors were male gender, left ventricular end-diastolic volume index by CMR (CMR-LVEDVi), and >3 segments with midwall fibrosis on LGE (HR: 2.131, 95% CI: 1.231-3.690, P = 0.007; HR: 3.161, 95% CI: 1.750-5.709, P < 0.001; and HR: 1.693, 95% CI: 1.084-2.644, P = 0.021, respectively). A composite clinical and CMR-based risk score provided a net reclassification improvement of 63.7% (P < 0.001) for MAACE occurrence when added to the model based on SOC evaluation. These findings were confirmed in the validation cohort. CONCLUSION: In a large multicentre, multivendor cohort registry reflecting daily clinical practice in NICM work-up, a composite clinical and CMR-based risk score provides incremental prognostic value beyond SOC evaluation, which may have impact on the indication of implantable cardioverter-defibrillator implantation.


Subject(s)
Cardiomyopathy, Dilated , Defibrillators, Implantable , Cardiomyopathy, Dilated/diagnostic imaging , Cardiomyopathy, Dilated/therapy , Contrast Media , Female , Gadolinium , Humans , Magnetic Resonance Imaging, Cine , Magnetic Resonance Spectroscopy , Male , Predictive Value of Tests , Prognosis , Registries , Stroke Volume , Ventricular Function, Left
11.
Int J Mol Sci ; 22(4)2021 Feb 20.
Article in English | MEDLINE | ID: mdl-33672625

ABSTRACT

Mitral valve prolapse (MVP) associated with severe mitral regurgitation is a debilitating disease with no pharmacological therapies available. MicroRNAs (miRNA) represent an emerging class of circulating biomarkers that have never been evaluated in MVP human plasma. Our aim was to identify a possible miRNA signature that is able to discriminate MVP patients from healthy subjects (CTRL) and to shed light on the putative altered molecular pathways in MVP. We evaluated a plasma miRNA profile using Human MicroRNA Card A followed by real-time PCR validations. In addition, to assess the discriminative power of selected miRNAs, we implemented a machine learning analysis. MiRNA profiling and validations revealed that miR-140-3p, 150-5p, 210-3p, 451a, and 487a-3p were significantly upregulated in MVP, while miR-223-3p, 323a-3p, 340-5p, and 361-5p were significantly downregulated in MVP compared to CTRL (p ≤ 0.01). Functional analysis identified several biological processes possible linked to MVP. In addition, machine learning analysis correctly classified MVP patients from CTRL with high accuracy (0.93) and an area under the receiving operator characteristic curve (AUC) of 0.97. To the best of our knowledge, this is the first study performed on human plasma, showing a strong association between miRNAs and MVP. Thus, a circulating molecular signature could be used as a first-line, fast, and cheap screening tool for MVP identification.


Subject(s)
Circulating MicroRNA/blood , Mitral Valve Insufficiency/blood , Mitral Valve Insufficiency/complications , Mitral Valve Prolapse/blood , Mitral Valve Prolapse/complications , Case-Control Studies , Down-Regulation/genetics , Female , Humans , Male , Middle Aged , Mitral Valve Insufficiency/genetics , Mitral Valve Prolapse/genetics , RNA, Messenger/genetics , RNA, Messenger/metabolism , Reproducibility of Results , Up-Regulation/genetics
12.
Radiology ; 292(3): 597-605, 2019 09.
Article in English | MEDLINE | ID: mdl-31335283

ABSTRACT

Background Coronary artery fractional flow reserve (FFR) derived from CT angiography (FFTCT) enables functional assessment of coronary stenosis. Prior clinical trials showed 13%-33% of coronary CT angiography studies had insufficient quality for quantitative analysis with FFRCT. Purpose To determine the rejection rate of FFRCT analysis and to determine factors associated with technically unsuccessful calculation of FFRCT. Materials and Methods Prospectively acquired coronary CT angiography scans submitted as part of the Assessing Diagnostic Value of Noninvasive FFRCT in Coronary Care (ADVANCE) registry (https://ClinicalTrials.gov: NCT02499679) and coronary CT angiography series submitted for clinical analysis were included. The primary outcome was the FFRCT rejection rate (defined as an inability to perform quantitative analysis with FFRCT). Factors that were associated with FFRCT rejection rate were assessed with multiple linear regression. Results In the ADVANCE registry, FFRCT rejection rate due to inadequate image quality was 2.9% (80 of 2778 patients; 95% confidence interval [CI]: 2.1%, 3.2%). In the 10 621 consecutive patients who underwent clinical analysis, the FFRCT rejection rate was 8.4% (n = 892; 95% CI: 6.2%, 7.2%; P < .001 vs the ADVANCE cohort). The main reason for the inability to perform FFRCT analysis was the presence of motion artifacts (63 of 80 [78%] and 729 of 892 [64%] in the ADVANCE and clinical cohorts, respectively). At multivariable analysis, section thickness in the ADVANCE (odds ratio [OR], 1.04; 95% CI: 1.001, 1.09; P = .045) and clinical (OR, 1.03; 95% CI: 1.02, 1.04; P < .001) cohorts and heart rate in the ADVANCE (OR, 1.05; 95% CI: 1.02, 1.08; P < .001) and clinical (OR, 1.06; 95% CI: 1.05, 1.07; P < .001) cohorts were independent predictors of rejection. Conclusion The rates for technically unsuccessful CT-derived fractional flow reserve in the ADVANCE registry and in a large clinical cohort were 2.9% and 8.4%, respectively. Thinner CT section thickness and lower patient heart rate may increase rates of completion of CT fractional flow reserve analysis. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Sakuma in this issue.


Subject(s)
Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/physiopathology , Fractional Flow Reserve, Myocardial/physiology , Aged , Cohort Studies , Female , Humans , Male , Prospective Studies , Registries , Reproducibility of Results , Severity of Illness Index
13.
Echocardiography ; 36(2): 312-319, 2019 02.
Article in English | MEDLINE | ID: mdl-30592791

ABSTRACT

BACKGROUND: Although 3D echocardiography (3DE) circumvents many limitations of 2D echocardiography by allowing direct measurements of left ventricular (LV) mass, it is seldom used in clinical practice due to time-consuming analysis. A recently developed 3DE machine learning (ML) approach allows automated determination of LV mass. We aimed to evaluate the accuracy of this new approach by comparing it to cardiac magnetic resonance (CMR) reference and to conventional 3DE volumetric analysis. METHODS: We prospectively studied 23 patients who underwent 3DE (Philips EPIQ) and CMR imaging on the same day. Single-beat wide-angle 3D datasets of the left ventricle were acquired. LV mass was quantified using the new automated software (Philips HeartModel) with manual corrections when necessary and using conventional volumetric analysis (TomTec). CMR analysis was performed by manual slice-by-slice tracing of LV endo- and epicardial boundaries. Reproducibility of the ML approach was assessed using repeated measurements and quantified by intra-class correlation (ICC) and coefficients of variation (CoV). RESULTS: Automated LV mass measurements were feasible in 20 patients (87%). The results were similar to CMR-derived values (Bland-Altman bias 5 g, limits of agreement ±37 g) and also to the conventional 3DE analysis (bias 7 g, ±27 g). Processing time was considerably shorter: 1.02 ± 0.24 minutes (CMR: 2.20 ± 0.13 minutes; TomTec: 2.36 ± 0.09 minutes), although manual corrections were performed in most patients. Repeated measurements showed high reproducibility: ICC = 0.99; CoV = 4 ± 5%. CONCLUSIONS: 3D Echocardiography analysis of LV mass using novel ML-based algorithm is feasible, fast, and accurate and may thus facilitate the incorporation of 3DE measurements of LV mass into clinical practice.


Subject(s)
Echocardiography, Three-Dimensional/methods , Heart Ventricles/diagnostic imaging , Heart Ventricles/pathology , Image Interpretation, Computer-Assisted/methods , Machine Learning , Algorithms , Automation , Female , Humans , Male , Middle Aged , Organ Size , Prospective Studies , Reproducibility of Results
14.
J Biomech Eng ; 141(10)2019 Oct 01.
Article in English | MEDLINE | ID: mdl-31053843

ABSTRACT

Prosthetic valve thrombosis (PVT) is a serious complication affecting prosthetic heart valves. The transvalvular mean pressure gradient (MPG) derived by Doppler echocardiography is a crucial index to diagnose PVT but may result in false negatives mainly in case of bileaflet mechanical valves (BMVs) in mitral position. This may happen because MPG estimation relies on simplifying assumptions on the transvalvular fluid dynamics or because Doppler examination is manual and operator dependent. A deeper understanding of these issues may allow for improving PVT diagnosis and management. To this aim, we used in vitro and fluid-structure interaction (FSI) modeling to simulate the function of a real mitral BMV in different configurations: normally functioning and stenotic with symmetric and completely asymmetric leaflet opening, respectively. In each condition, the MPG was measured in vitro, computed directly from FSI simulations and derived from the corresponding velocity field through a Doppler-like postprocessing approach. Following verification versus in vitro data, MPG computational data were analyzed to test their dependency on the severity of fluid-dynamic derangements and on the measurement site. Computed MPG clearly discriminated between normally functioning and stenotic configurations. They did not depend markedly on the site of measurement, yet differences below 3 mmHg were found between MPG values at the central and lateral orifices of the BMV. This evidence suggests a mild uncertainty of the Doppler-based evaluation of the MPG due to probe positioning, which yet may lead to false negatives when analyzing subjects with almost normal MPG.

15.
Am Heart J ; 168(3): 332-9, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25173545

ABSTRACT

BACKGROUND: Multidetector computed tomography (MDCT) provides detailed assessment of valve annulus and iliofemoral vessels in transcatheter aortic valve replacement (TAVR) patients. However, data on diagnostic performance of MDCT coronary angiography (MDCT-CA) are scarce. The aim of the study is to assess diagnostic performance of MDCT for coronary artery evaluation before TAVR. METHODS: A total of 325 consecutive patients (234 without previous myocardial revascularization, 49 with previous coronary stenting, and 42 with previous coronary artery bypass graft [CABG]) underwent invasive coronary angiography and MDCT before TAVR. MDCT-CA was performed using the same data set dedicated to standard MDCT aortic annulus evaluation. Multidetector computed tomography-CA evaluability and diagnostic accuracy in comparison with invasive coronary angiography as criterion standard were assessed. RESULTS: The MDCT-CA evaluability of native coronaries was 95.6%. The leading cause of unevaluability was beam-hardening artifact due to coronary calcifications. In a segment-based analysis, MDCT-CA showed sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for detecting ≥50% stenosis of 91%, 99.2%, 83.4%, 99.6% and 98.8%, respectively. The MDCT-CA evaluability of coronary stents was 82.1%. In a segment-based analysis, MDCT-CA showed sensitivity, specificity, PPV, NPV, and accuracy for detecting ≥50% in-stent restenosis of 94.1%, 86.7%, 66.7%, 98.1%, and 88.3%, respectively. All CABGs were correctly assessed by MDCT-CA. In a patient-based analysis, MDCT-CA showed sensitivity, specificity, PPV, NPV, and accuracy of 89.7%, 90.8%, 80.6%, 95.4%, and 90.5%, respectively. CONCLUSIONS: Multidetector computed tomography-CA allows to correctly rule out the presence of significant native coronary artery stenosis, significant in-stent restenosis, and CABG disease in patients referred for TAVR.


Subject(s)
Aortic Valve , Coronary Angiography/methods , Coronary Vessels/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Comorbidity , Coronary Artery Bypass , Coronary Artery Disease/diagnosis , Coronary Artery Disease/epidemiology , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/epidemiology , Female , Heart Valve Diseases/epidemiology , Humans , Image Processing, Computer-Assisted , Male , Multidetector Computed Tomography , Predictive Value of Tests , Radiation Dosage , Sensitivity and Specificity , Stents
16.
Ann Biomed Eng ; 52(5): 1297-1312, 2024 May.
Article in English | MEDLINE | ID: mdl-38334838

ABSTRACT

Predictive modeling of hyperemic coronary and myocardial blood flow (MBF) greatly supports diagnosis and prognostic stratification of patients suffering from coronary artery disease (CAD). In this work, we propose a novel strategy, using only readily available clinical data, to build personalized inlet conditions for coronary and MBF models and to achieve an effective calibration for their predictive application to real clinical cases. Experimental data are used to build personalized pressure waveforms at the aortic root, representative of the hyperemic state and adapted to surrogate the systolic contraction, to be used in computational fluid-dynamics analyses. Model calibration to simulate hyperemic flow is performed in a "blinded" way, not requiring any additional exam. Coronary and myocardial flow simulations are performed in eight patients with different clinical conditions to predict FFR and MBF. Realistic pressure waveforms are recovered for all the patients. Consistent pressure distribution, blood velocities in the large arteries, and distribution of MBF in the healthy myocardium are obtained. FFR results show great accuracy with a per-vessel sensitivity and specificity of 100% according to clinical threshold values. Mean MBF shows good agreement with values from stress-CTP, with lower values in patients with diagnosed perfusion defects. The proposed methodology allows us to quantitatively predict FFR and MBF, by the exclusive use of standard measures easily obtainable in a clinical context. This represents a fundamental step to avoid catheter-based exams and stress tests in CAD diagnosis.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Humans , Coronary Angiography/methods , Calibration , Predictive Value of Tests , Computer Simulation
17.
J Clin Med ; 13(5)2024 Mar 06.
Article in English | MEDLINE | ID: mdl-38592382

ABSTRACT

Background: Currently, transcatheter aortic valve implantation (TAVI) is the standard procedure recommended for patients over 75 years of age with symptomatic aortic valve stenosis. Percutaneous transfemoral (TF) access is the main route used to perform the procedure. Among periprocedural complications, access-related ones are the most frequent, potentially leading to prolonged in-hospital stays and transfusions. Methods: We performed a retrospective analysis of prospectively collected data on consecutive patients undergoing TF-TAVI with the latest generation balloon-expandable transcatheter valve between 2013 and 2022. Results: A total of 600 patients were analyzed, differentiating the population between ultrasound-guided and blind common femoral artery puncture. Valve Academic Research Consortium 3 (VARC-3)criteria were used to report at 30 days and follow-up. In our propensity-matched comparison of the two groups, we found a strong reduction in access-related complications in the echo-guided group, particularly in terms of reduction of major and minor bleedings. We also found a significant trend in reduction of local complications, such as pseudoaneurysms, hematomas, arterio-venous fistulas, dissection of the femoral or iliac arteries, and stenosis. Conclusions: Although there is a lack of consensus on the role of ultrasound-guided puncture, we found better outcomes for patients having an echo-guided puncture of the main access, particularly with regard to access-related complications, early mobilization, and early discharge home.

18.
J Clin Med ; 13(8)2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38673582

ABSTRACT

The interventricular septum (IVS) is a core myocardial structure involved in biventricular coupling and performance. Physiologically, during systole, it moves symmetrically toward the center of the left ventricle (LV) and opposite during diastole. Several pathological conditions produce a reversal or paradoxical septal motion, such as after uncomplicated cardiac surgery (CS). The postoperative paradoxical septum (POPS) was observed in a high rate of cases, representing a unicum in the panorama of paradoxical septa as it does not induce significant ventricular morpho-functional alterations nor negative clinical impact. Although it was previously considered a postoperative event, evidence suggests that it might also appear during surgery and gradually resolve over time. The mechanism behind this phenomenon is still debated. In this article, we will provide a comprehensive review of the various theories generated over the past fifty years to explain its pathological basis. Finally, we will attempt to give a heuristic interpretation of the biventricular postoperative motion pattern based on the switch of the ventricular anchor points.

19.
Geroscience ; 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38689157

ABSTRACT

Aging per se is a major risk factor for cardiovascular diseases and is associated with progressive changes in cardiac structure and function. Rodent models are commonly used to study cardiac aging, but do not closely mirror differences as they occur in humans. Therefore, we performed a 2D echocardiographic study in non-human primates (NHP) to establish age- and sex-associated differences in cardiac function and morphometry in this animal model. M mode and 2D echocardiography and Doppler analyses were performed cross-sectionally in 38 healthy rhesus monkeys (20 females and 18 males), both young (age 7-12 years; n = 20) and old (age 19-30 years; n = 18). The diameters of the cardiac chambers did not differ significantly by age group, but males had larger left ventricular diameters (2.43 vs 2.06 cm in diastole and 1.91 vs 1.49 cm in systole, p = 0.0004 and p = 0.0001, respectively) and left atrial diameter (1.981 vs 1.732 cm; p = 0.0101). Left ventricular mass/body surface area did not vary significantly with age and sex. Ejection fraction did not differ by age and females presented a higher ejection fraction than males (54.0 vs 50.8%, p = 0.0237). Diastolic function, defined by early to late mitral peak flow velocity ratio (E/A), was significantly lower in old rhesus monkeys (2.31 vs 1.43, p = 0.0020) and was lower in females compared to males (1.595 vs 2.230, p = 0.0406). Right ventricular function, evaluated by measuring the Tricuspid Annular Plane Systolic Excursion, did not differ by age or sex, and Right Ventricular Free Wall Longitudinal Strain, did not differ with age but was lower in males than in females (-22.21 vs -17.95%, p = 0.0059). This is the first echocardiographic study to evaluate age- and sex-associated changes of cardiac morphometry and function in young and old NHP. The findings of this work will provide a reference to examine the effect of age and sex on cardiac diseases in NHP.

20.
J Clin Med ; 13(12)2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38929984

ABSTRACT

Chronic coronary syndrome (CCS) is one of the leading cardiovascular causes of morbidity, mortality, and use of medical resources. After the introduction by international guidelines of the same level of recommendation to non-invasive imaging techniques in CCS evaluation, a large debate arose about the dilemma of choosing anatomical (with coronary computed tomography angiography (CCTA)) or functional imaging (with stress echocardiography (SE), cardiovascular magnetic resonance (CMR), or nuclear imaging techniques) as a first diagnostic evaluation. The determinant role of the atherosclerotic burden in defining cardiovascular risk and prognosis more than myocardial inducible ischemia has progressively increased the use of a first anatomical evaluation with CCTA in a wide range of pre-test probability in CCS patients. Functional testing holds importance, both because the role of revascularization in symptomatic patients with proven ischemia is well defined and because functional imaging, particularly with stress cardiac magnetic resonance (s-CMR), gives further prognostic information regarding LV function, detection of myocardial viability, and tissue characterization. Emerging techniques such as stress computed tomography perfusion (s-CTP) and fractional flow reserve derived from CT (FFRCT), combining anatomical and functional evaluation, appear capable of addressing the need for a single non-invasive examination, especially in patients with high risk or previous revascularization. Furthermore, CCTA in peri-procedural planning is promising to acquire greater importance in the non-invasive planning and guiding of complex coronary revascularization procedures, both by defining the correct strategy of interventional procedure and by improving patient selection. This review explores the different roles of non-invasive imaging techniques in managing CCS patients, also providing insights into preoperative planning for percutaneous or surgical myocardial revascularization.

SELECTION OF CITATIONS
SEARCH DETAIL